Analysis of Discrepancies Between Pulse Oximetry and Arterial Oxygen Saturation Measurements by Race and Ethnicity and Association With Organ Dysfunction and Mortality
Open accessAbstract
Importance: Discrepancies in oxygen saturation measured by pulse oximetry (Spo2), when compared with arterial oxygen saturation (Sao2) measured by arterial blood gas (ABG), may differentially affect patients according to race and ethnicity. However, the association of these disparities with health outcomes is unknown. Objective: To examine racial and ethnic discrepancies between Sao2 and Spo2 measures and their associations with clinical outcomes. Design, Setting, and Participants: This multicenter, retrospective, cross-sectional study included 3 publicly available electronic health record (EHR) databases (ie, the Electronic Intensive Care Unit-Clinical Research Database and Medical Information Mart for Intensive Care III and IV) as well as Emory Healthcare (2014-2021) and Grady Memorial (2014-2020) databases, spanning 215 hospitals and 382 ICUs. From 141 600 hospital encounters with recorded ABG measurements, 87 971 participants with first ABG measurements and an Spo2 of at least 88% within 5 minutes before the ABG test were included. Exposures: Patients with hidden hypoxemia (ie, Spo2 ≥88% but Sao2 <88%). Main Outcomes and Measures: Outcomes, stratified by race and ethnicity, were Sao2 for each Spo2, hidden hypoxemia prevalence, initial demographic characteristics (age, sex), clinical outcomes (in-hospital mortality, length of stay), organ dysfunction by scores (Sequential Organ Failure Assessment [SOFA]), and laboratory values (lactate and creatinine levels) before and 24 hours after the ABG measurement. Results: The first Spo2-Sao2 pairs from 87 971 patient encounters (27 713 [42.9%] women; mean [SE] age, 62.2 [17.0] years; 1919 [2.3%] Asian patients; 26 032 [29.6%] Black patients; 2397 [2.7%] Hispanic patients, and 57 632 [65.5%] White patients) were analyzed, with 4859 (5.5%) having hidden hypoxemia. Hidden hypoxemia was observed in all subgroups with varying incidence (Black: 1785 [6.8%]; Hispanic: 160 [6.0%]; Asian: 92 [4.8%]; White: 2822 [4.9%]) and was associated with greater organ dysfunction 24 hours after the ABG measurement, as evidenced by higher mean (SE) SOFA scores (7.2 [0.1] vs 6.29 [0.02]) and higher in-hospital mortality (eg, among Black patients: 369 [21.1%] vs 3557 [15.0%]; P < .001). Furthermore, patients with hidden hypoxemia had higher mean (SE) lactate levels before (3.15 [0.09] mg/dL vs 2.66 [0.02] mg/dL) and 24 hours after (2.83 [0.14] mg/dL vs 2.27 [0.02] mg/dL) the ABG test, with less lactate clearance (-0.54 [0.12] mg/dL vs -0.79 [0.03] mg/dL). Conclusions and Relevance: In this study, there was greater variability in oxygen saturation levels for a given Spo2 level in patients who self-identified as Black, followed by Hispanic, Asian, and White. Patients with and without hidden hypoxemia were demographically and clinically similar at baseline ABG measurement by SOFA scores, but those with hidden hypoxemia subsequently experienced higher organ dysfunction scores and higher in-hospital mortality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Figures

![Figure 2. Modified Bland-Altman Plots by Race and Ethnicity On each plot, the bold horizontal lines represent the mean bias (defined as the difference between the oxygen saturation measured by pulse oximetry [Spo2] and arterial blood gas value [Sao2]) for each of the 2 Spo2 groups. The blue lines, with dashed blue lines indicating 95% CIs, are for the group with Spo2 of 88% to 92%, and the orange lines, with dashed orange lines indicating 95% CIs, for the group with Spo2 of 93% to 96%. The solid black line indicates the absence of bias (ie, Spo2 − Sao2 = 0). When the mean bias is above the black line, there is positive bias in the pulse oximetry measurement (ie, the observed Spo2 is greater than the true Sao2). In contrast, when the mean bias is below the black line, there is negative bias in the pulse oximetry measurement (ie, the observed Spo2 is below the true Sao2).](/paper-figures/66f4dbf06a1b43b598a12906dc016ab7/analysis-of-discrepancies-between-pulse-oximetry-and-arterial-oxygen-saturation-figure-2.jpg)
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“leading to lower hospital admission; higher occult hypoxemia; and delayed or no access to dexamethasone, therapeutic oxygen, and COVID-19 therapies, resulting in increased hospital readmission, organ dysfunction, and mortality [11-18].”
From Impact of skin pigmentation on pulse oximetry blood oxygenation and wearable pulse rate accuracy: systematic review and meta-analysis (2024) · cites this paper as [15]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Recent studies have shown a positive bias in oxygen saturation measurements in patients with darkly pigmented skin, particularly under low saturation conditions.”
From Skin pigmentation influence on pulse oximetry accuracy: a systematic review and bibliometric analysis (2022) · cites this paper as [54]
The cited source says what the claim attributes to it.
In the citing paper
“Patients with darker skin pigmentation are more likely than patients with lighter skin color to have overestimated SpO2 readings”
From Impact of skin pigmentation on pulse oximetry blood oxygenation and wearable pulse rate accuracy: systematic review and meta-analysis (2024) · cites this paper as [15]
In the citing paper
“More recent studies have also revealed that dark skin pigmentation influences the accuracy and performance of pulse oximeters devices, resulting in overestimations [17,49,50,51,52,53] with increased incidence in the risk for occult hypoxemia (SO2<88% despite normal SpO2>92%) [54,55].”
From Skin pigmentation influence on pulse oximetry accuracy: a systematic review and bibliometric analysis (2022) · cites this paper as [54]
In the citing paper
“Due to this increasing evidence, several health organizations and healthcare professionals have raised growing concerns about the clinical accuracy of pulse oximetry in dark-skinned patients [20,57,58,59,60,61], particularly in detecting occult hypoxemia [54,55].”
From Skin pigmentation influence on pulse oximetry accuracy: a systematic review and bibliometric analysis (2022) · cites this paper as [54]
In the citing paper
“A prevalence of occult hypoxemia in dark-skinned subjects has been recently confirmed in three studies, showing that dark-skinned patients may have over three times the risk of experiencing occult hypoxemia during hospitalization compared to light-skinned patients [53,54,55].”
From Skin pigmentation influence on pulse oximetry accuracy: a systematic review and bibliometric analysis (2022) · cites this paper as [54]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
Vincent, J. L., Moreno, R., Takala, J., Willatts, S., De Mendonça, A., Bruining, H., Reinhart, C. K., Suter, P. M., & Thijs, L. G. (1996) · Intensive Care Medicine · doi:10.1007/bf01709751 · Cited by 11,674
MIMIC-III, a freely accessible critical care database
Johnson, A. E. W., Pollard, T. J., Shen, L., Lehman, L.-W. H., Feng, M., Ghassemi, M., Moody, B., Szolovits, P., Anthony Celi, L., & Mark, R. G. (2016) · Scientific Data · doi:10.1038/sdata.2016.35 · Cited by 8,141
Vandenbroucke, J. P., Elm, E. V., Altman, D. G., Gøtzsche, P. C., Mulrow, C. D., Pocock, S. J., Poole, C., Schlesselman, J. J., Egger, M., & initiative, F. T. S. (2007) · Annals of Internal Medicine · doi:10.7326/0003-4819-147-8-200710160-00010-w1 · Cited by 3,543
The Triad of Sleep Apnea, Hypertension, and Chronic Kidney Disease: A Spectrum of Common Pathology
Aziz, F., & Chaudhary, K. R. (2016) · Cardiorenal Medicine · doi:10.1159/000450796 · Cited by 3,285
Pollard, T. J., Johnson, A. E. W., Raffa, J. D., Celi, L. A., Mark, R. G., & Badawi, O. (2018) · Scientific Data · doi:10.1038/sdata.2018.178 · Cited by 1,993
Racial bias in pulse oximetry measurement
Sjoding, M. W., Dickson, R. P., Iwashyna, T. J., Gay, S. E., & Valley, T. S. (2020) · New England Journal of Medicine · doi:10.1056/nejmc2029240 · Cited by 1,114
Jansen, T. C., van Bommel, J., Schoonderbeek, F. J., Sleeswijk Visser, S. J., van der Klooster, J. M., Lima, A. P., Willemsen, S. P., & Bakker, J. (2010) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200912-1918oc · Cited by 894
Intermittent Hypoxemia and OSA
Dewan, N. A., Nieto, F. J., & Somers, V. K. (2015) · Chest · doi:10.1378/chest.14-0500 · Cited by 641
Effects of skin pigmentation on pulse oximeter accuracy at low saturation
Bickler, P. E., Feiner, J. R., & Severinghaus, J. W. (2005) · Anesthesiology · doi:10.1097/00000542-200504000-00004 · Cited by 427
Cited by
Sorted by citations
A New Global Definition of Acute Respiratory Distress Syndrome
Matthay, M. A., Arabi, Y. M., Arroliga, A. C., Bernard, G. R., Bersten, A. D., Brochard, L. J., Calfee, C. S., Combes, A., Daniel, B. M., Ferguson, N. D., et al. (2023) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.202303-0558ws · Cited by 916
Porsbjerg, C. M., Melén, E., Lehtimäki, L. A., & Shaw, D. E. (2023) · The Lancet · doi:10.1016/s0140-6736(22)02125-0 · Cited by 632
Fawzy, A., Wu, T. D., Wang, K., Robinson, M. L., Farha, J., Bradke, A., Golden, S. H., Xu, Y., & Garibaldi, B. T. (2022) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2022.1906 · Cited by 326
Wearable Photoplethysmography for Cardiovascular Monitoring
Charlton, P. H., Kyriacou, P. A., Mant, J., Marozas, V., Chowienczyk, P., & Alastruey, J. (2022) · Proceedings of the IEEE · doi:10.1109/jproc.2022.3149785 · Cited by 250
The Sequential Organ Failure Assessment (SOFA) Score: has the time come for an update?
Moreno, R. P., Rhodes, A., Piquilloud, L., Glenn Hernández, P., Takala, J. A., Gershengorn, H. B., Tavares, M., Coopersmith, C. M., Myatra, S. N., Singer, M., et al. (2023) · Critical Care · doi:10.1186/s13054-022-04290-9 · Cited by 258
Greif, R., Bray, J., Djärv, T., Drennan, I. R., Liley, H. G., Ng, K.-C., Cheng, A., Douma, M. J., Scholefield, B. R., Smyth, M. A., et al. (2024) · Circulation · doi:10.1161/cir.0000000000001288 · Cited by 185
Leveraging electronic health records for data science: common pitfalls and how to avoid them
Sauer, C. M., Chen, L.-C., Hyland, S. L., Girbes, A. R. J., Elbers, P., & Celi, L. A. (2022) · The Lancet Digital Health · doi:10.1016/s2589-7500(22)00154-6 · Cited by 183
Berg, K. M., Bray, J., Ng, K.-C., Liley, H. G., Greif, R., Carlson, J. N., Morley, P. T., Drennan, I. R., Smyth, M. A., Scholefield, B. R., et al. (2023) · Circulation · doi:10.1161/cir.0000000000001179 · Cited by 177
Shi, C., Goodall, M., Dumville, J., Hill, J., Norman, G., Hamer, O., Clegg, A., Watkins, C. L., Georgiou, G., Hodkinson, A., et al. (2022) · doi:10.1101/2022.02.16.22271062 · Cited by 158
Gottlieb, E. R., Ziegler, J., Morley, K., Rush, B., & Celi, L. A. (2022) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2022.2587 · Cited by 134
Valbuena, V. S. M., Seelye, S., Sjoding, M. W., Valley, T. S., Dickson, R. P., Gay, S. E., Claar, D., Prescott, H. C., & Iwashyna, T. J. (2022) · BMJ · doi:10.1136/bmj-2021-069775 · Cited by 127
Cabanas, A. M., Fuentes-Guajardo, M., Latorre, K., León, D., & Martín-Escudero, P. (2022) · Sensors · doi:10.3390/s22093402 · Cited by 124
A review of the effect of skin pigmentation on pulse oximeter accuracy
Al-Halawani, R., Charlton, P. H., Qassem, M., & Kyriacou, P. A. (2023) · Physiological Measurement · doi:10.1088/1361-6579/acd51a · Cited by 119
Wearable Photoplethysmography for Cardiovascular Monitoring.
Charlton, P. H., Kyriacou, P. A., Mant, J., Marozas, V., Chowienczyk, P., & Alastruey, J. (2022) · KTUePubl (Repository of Kaunas University of Technology) · doi:10.17863/cam.81148 · Cited by 113
Berg, K. M., Bray, J., Ng, K.-C., Liley, H. G., Greif, R., Carlson, J. N., Morley, P. T., Drennan, I. R., Smyth, M. A., Scholefield, B. R., et al. (2023) · Resuscitation · doi:10.1016/j.resuscitation.2023.109992 · Cited by 117
Hirsch, K. G., Amorim, E., Coppler, P. J., Drennan, I. R., Elliott, A., Gordon, A. J., Jentzer, J. C., Johnson, N. J., Moskowitz, A., Mumma, B. E., et al. (2025) · Circulation · doi:10.1161/cir.0000000000001375 · Cited by 125
Assessment of ownership of smart devices and the acceptability of digital health data sharing
Shandhi, M. M. H., Singh, K., Janson, N., Ashar, P., Singh, G., Lu, B., Hillygus, D. S., Maddocks, J., & Dunn, J. (2024) · npj Digital Medicine · doi:10.1038/s41746-024-01030-x · Cited by 98
Greif, R., Bray, J., Djärv, T., Drennan, I. R., Liley, H. G., Ng, K.-C., Cheng, A., Douma, M. J., Scholefield, B. R., Smyth, M., et al. (2024) · Resuscitation · doi:10.1016/j.resuscitation.2024.110414 · Cited by 94
Racial Disparity in Oxygen Saturation Measurements by Pulse Oximetry: Evidence and Implications
Jamali, H., Castillo, L. T., Morgan, C. C., Coult, J., Muhammad, J. L., Osobamiro, O. O., Parsons, E. C., & Adamson, R. (2022) · Annals of the American Thoracic Society · doi:10.1513/annalsats.202203-270cme · Cited by 83
Martín, D., Johns, C., Sorrell, L., Healy, E., Phull, M., Olusanya, O., Peters, M. J., & Fabes, J. (2024) · British Journal of Anaesthesia · doi:10.1016/j.bja.2024.01.023 · Cited by 84
Gudelunas, M. K., Lipnick, M. S., Hendrickson, C. M., Vanderburg, S. B., Okunlola, B., Auchus, I., Feiner, J., & Bickler, P. E. (2023) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000006755 · Cited by 68
Sudat, S. E. K., Wesson, P., Rhoads, K. F., Brown, S., Aboelata, N., Pressman, A. R., Mani, A., & Azar, K. M. J. (2022) · American Journal of Epidemiology · doi:10.1093/aje/kwac164 · Cited by 58
Fawzy, A., Wu, T. D., Wang, K., Sands, K. E., Fisher, A. M., Arnold Egloff, S. A., DellaVolpe, J. D., Iwashyna, T. J., Xu, Y., & Garibaldi, B. T. (2023) · JAMA Network Open · doi:10.1001/jamanetworkopen.2023.30856 · Cited by 50
Inherent Bias in Electronic Health Records: A Scoping Review of Sources of Bias
Perets, O., Stagno, E., Yehuda, E. B., McNichol, M. C., Celi, L. A., Rappoport, N., & Dorotić, M. (2025) · ACM Transactions on Intelligent Systems and Technology · doi:10.1145/3757924 · Cited by 62
Helms, J., Catoire, P., Vuillaume, L. A., Bannelier, H., Douillet, D., Dupuis, C., Federici, L., Jezequel, M., Jozwiak, M., Kuteifan, K., et al. (2024) · Annals of Intensive Care · doi:10.1186/s13613-024-01367-2 · Cited by 56
Melanometry for objective evaluation of skin pigmentation in pulse oximetry studies
Vasudevan, S., Vogt, W. C., Weininger, S., & Pfefer, T. J. (2024) · Communications Medicine · doi:10.1038/s43856-024-00550-7 · Cited by 46
Disparity dashboards: an evaluation of the literature and framework for health equity improvement
Gallifant, J., Kistler, E. A., Nakayama, L. F., Zera, C., Kripalani, S. B., Ntatin, A., Fernández, L., Bates, D. W., Dankwa‐Mullan, I., & Celi, L. A. (2023) · The Lancet Digital Health · doi:10.1016/s2589-7500(23)00150-4 · Cited by 45
Skin Assessment in Patients with Dark Skin Tone
Pusey‐Reid, E., Quinn, L., Samost, M. E., & Reidy, P. A. (2023) · AJN American Journal of Nursing · doi:10.1097/01.naj.0000921800.61980.7e · Cited by 43
Accuracy of Multiple Pulse Oximeters in Stable Critically Ill Patients
Blanchet, M.-A., Mercier, G., Delobel, A., Nayet, E., Bouchard, P.-A., Simard, S., L’Her, E., Branson, R. D., & Lellouche, F. (2023) · Respiratory Care · doi:10.4187/respcare.10582 · Cited by 42
de Hond, A., van Buchem, M. M., & Hernandez‐Boussard, T. (2022) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocac156 · Cited by 40
Admission vital signs as predictors of COVID-19 mortality: a retrospective cross-sectional study
Ikram, A. S., & Pillay, S. (2022) · BMC Emergency Medicine · doi:10.1186/s12873-022-00631-7 · Cited by 39
Critical Bias in Critical Care Devices
Charpignon, M.-L., Byers, J., Cabral, S., Celi, L. A., Fernandes, C., Gallifant, J., Lough, M. E., Mlombwa, D., Moukheiber, L., Ong, B. A., et al. (2023) · Critical Care Clinics · doi:10.1016/j.ccc.2023.02.005 · Cited by 35
Skin colour affects the accuracy of medical oxygen sensors
Keller, M. D., Harrison-Smith, B., Patil, C., & Arefin, M. S. (2022) · Nature · doi:10.1038/d41586-022-03161-1 · Cited by 38
Racial and Ethnic Bias in Pulse Oximetry and Clinical Outcomes
Valbuena, V. S. M., Merchant, R. M., & Hough, C. L. (2022) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2022.1903 · Cited by 37
Marinari, S., Volpe, P., Simoni, M., Aventaggiato, M., Benedetto, F. D., Nardini, S. G., Sanguinetti, C. M., & Palange, P. (2022) · Sensors · doi:10.3390/s22135031 · Cited by 39
Singh, S., Bennett, M. R., Chen, C., Shin, S., Ghanbari, H., & Nelson, B. W. (2024) · Journal of Medical Internet Research · doi:10.2196/62769 · Cited by 36
Investigating the accuracy of blood oxygen saturation measurements in common consumer smartwatches
Jiang, Y., Spies, C., Magin, J., Bhosai, S. J., Snyder, L., & Dunn, J. (2023) · PLOS Digital Health · doi:10.1371/journal.pdig.0000296 · Cited by 36
Chesley, C. F., Lane-Fall, M. B., Panchanadam, V., Harhay, M. O., Wani, A. A., Mikkelsen, M. E., & Fuchs, B. D. (2022) · Respiratory Care · doi:10.4187/respcare.09769 · Cited by 38
Racial effects on Masimo pulse oximetry: a laboratory study
Barker, S. J., & Wilson, W. C. (2023) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-022-00927-w · Cited by 36
Sjoding, M. W., Iwashyna, T. J., & Valley, T. S. (2022) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.202209-1773ed · Cited by 29
Skin Pigmentation and Pulse Oximeter Accuracy in the Intensive Care Unit: A Pilot Prospective Study
Fawzy, A., Ali, H., Dziedzic, P. H., Potu, N., Calvillo, E., Golden, S. H., Iwashyna, T. J., Suárez, J. I., Hager, D. N., & Garibaldi, B. T. (2024) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.202401-0036le · Cited by 28
Cabanas, A. M., Martín-Escudero, P., & Shelley, K. H. (2023) · British Journal of Anaesthesia · doi:10.1016/j.bja.2023.07.005 · Cited by 28
Representation of dark skin tones in foundational nursing textbooks: An image analysis
Pusey‐Reid, E., Quinn, L. W., Wong, J. W., & Wucherpfennig, A. (2023) · Nurse Education Today · doi:10.1016/j.nedt.2023.105927 · Cited by 28
Racial and skin color mediated disparities in pulse oximetry in infants and young children
Sharma, M., Brown, A. W., Powell, N. M., Rajaram, N., Tong, L., Mourani, P. M., & Schootman, M. (2024) · Paediatric Respiratory Reviews · doi:10.1016/j.prrv.2023.12.006 · Cited by 29
Kyriacou, P. A., Charlton, P. H., Al-Halawani, R., & Shelley, K. H. (2022) · British Journal of Anaesthesia · doi:10.1016/j.bja.2022.03.011 · Cited by 27
Pulse Oximetry and Race in Critically Ill Adults
Seitz, K. P., Wang, L., Casey, J. D., Markus, S. A., Jackson, K. E., Qian, E. T., Self, W. H., Rice, T. W., & Semler, M. W. (2022) · Critical Care Explorations · doi:10.1097/cce.0000000000000758 · Cited by 28
Melanin bias in pulse oximetry explained by light source spectral bandwidth
Bierman, A., Benner, K. J., & Rea, M. S. (2024) · British Journal of Anaesthesia · doi:10.1016/j.bja.2024.01.037 · Cited by 24
Parr, N. J., Beech, E. H., Young, S., & Valley, T. S. (2024) · Journal of General Internal Medicine · doi:10.1007/s11606-024-08852-1 · Cited by 22
Hess, M. W. (2023) · Respiratory Care · doi:10.4187/respcare.10876 · Cited by 21
Retinal Scans and Data Sharing: The Privacy and Scientific Development Equilibrium
Nakayama, L. F., de Matos, J. C. R. G., Stewart, I. U., Mitchell, W. G., Martinez‐Martin, N., Regatieri, C. V., & Celi, L. A. (2023) · Mayo Clinic Proceedings Digital Health · doi:10.1016/j.mcpdig.2023.02.003 · Cited by 23
Participant flow diagrams for health equity in AI
Ellen, J., de Matos, J. C. R. G., Viola, M., Gallifant, J., Quion, J. M., Celi, L. A., & Hussein, N. S. A. (2024) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2024.104631 · Cited by 22
Utility of Skin Tone on Pulse Oximetry in Critically Ill Patients: A Prospective Cohort Study
Hao, S., Dempsey, K., de Matos, J. C. R. G., Cox, C. E., Rotemberg, V. M., Gichoya, J. W., Kibbe, W. A., Hong, C., & Wong, A.-K. I. (2024) · Critical Care Explorations · doi:10.1097/cce.0000000000001133 · Cited by 18
High risk and low prevalence diseases: Acute chest syndrome in sickle cell disease
Koehl, J. L., Koyfman, A., Hayes, B. D., & Long, B. (2022) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2022.06.018 · Cited by 19
Remote Hub Lab – RHL: Broadly Accessible Technologies for Education and Telehealth
Hussein, R., Chap, B., Inoñan, M., Guo, M., Monroy, F. L., Maloney, R. C., Ferreria, S. A., & Kalisi, S. J. (2023) · Lecture notes in networks and systems · doi:10.1007/978-3-031-42467-0_7 · Cited by 18
Alrawashdeh, M., Klompas, M., & Rhee, C. (2024) · Critical Care Medicine · doi:10.1097/ccm.0000000000006338 · Cited by 17
Origins of Racial and Ethnic Bias in Pulmonary Technologies
Sjoding, M. W., Ansari, S., & Valley, T. S. (2022) · Annual Review of Medicine · doi:10.1146/annurev-med-043021-024004 · Cited by 18
Herbst, A., Goel, S., Beane, A., Brotherton, B. J., Dula, D., Ely, E. W., Gordon, S. B., Haniffa, R., Hedt‐Gauthier, B., Limbani, F., et al. (2023) · Frontiers in Medicine · doi:10.3389/fmed.2023.1148334 · Cited by 17
Pulse oximetry values from 33,080 participants in the Apple Heart & Movement Study
Shapiro, I., Stein, J., MacRae, C. A., & OReilly, M. (2023) · npj Digital Medicine · doi:10.1038/s41746-023-00851-6 · Cited by 18
Kalra, A., Shou, B. L., Zhao, D. X., Wilcox, C. J., Keller, S. P., Kim, B. S., Whitman, G. J. R., Cho, S., Leng, A., Geeza, A., et al. (2023) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2023.09.019 · Cited by 14
Determining factors of pulse oximetry accuracy: a literature review
Valladares, D. L., Mateu, L. A. B., Cortés-Carmona, N., Fuentes-Lizana, G., Cabanas, A. M., Latorre-Progulakis, K., Fuentes‐Guajardo, M., & Martín-Escudero, P. (2024) · Revista Clínica Española (English Edition) · doi:10.1016/j.rceng.2024.04.005 · Cited by 20
Pulse oximetry in pediatric care: Balancing advantages and limitations
Al‐Beltagi, M., Saeed, N. K., Bediwy, A. S., & Elbeltagi, R. M. (2024) · World Journal of Clinical Pediatrics · doi:10.5409/wjcp.v13.i3.96950 · Cited by 20
Verma, A. A., Trbovich, P., Mamdani, M., & Shojania, K. G. (2023) · BMJ Quality & Safety · doi:10.1136/bmjqs-2022-015713 · Cited by 17
Ewerlöf, M., Strömberg, T., Larsson, M., & Salerud, E. G. (2022) · Journal of Biomedical Optics · doi:10.1117/1.jbo.27.3.036004 · Cited by 15
Kalra, A., Shou, B. L., Zhao, D. X., Wilcox, C. J., Keller, S. P., Whitman, G. J. R., Kim, B. S., Cho, S., Calligy, K., Brown, P., et al. (2023) · JTCVS Open · doi:10.1016/j.xjon.2023.02.011 · Cited by 12
Charpignon, M., Carrel, A., Jiang, Y., Kwaga, T., Cantada, B., Hyslop, T., Cox, C. E., Haines, K., Koomson, V. J., Dumas, G., et al. (2023) · PLOS Digital Health · doi:10.1371/journal.pdig.0000244 · Cited by 17
A new tool for evaluating health equity in academic journals; the Diversity Factor
Gallifant, J., Zhang, J., Whebell, S. F., Quion, J., Escobar, B., Gichoya, J. W., Herrera, K. V., Jina, R., Chidambaram, S., Mehndiratta, A., et al. (2023) · PLOS Global Public Health · doi:10.1371/journal.pgph.0002252 · Cited by 14
The Global Definition of Acute Respiratory Distress Syndrome: Ready for Prime Time?
Smit, M. R., Brower, R. G., Parsons, P. E., Phua, J., & Bos, L. D. J. (2023) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.202308-1369ed · Cited by 14
Racial effects on masimo pulse oximetry: impact of low perfusion index
Sharma, V., Barker, S. J., Sorci, R., Park, L., & Wilson, W. C. (2024) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-023-01113-2 · Cited by 14
Garnet, B., Lankenau, R. D., Jean, E., & Campos, M. (2023) · Annals of the American Thoracic Society · doi:10.1513/annalsats.202209-837oc · Cited by 15
Haxha, S., Nwibor, C., Ali, M., Sakel, M., Saunders, K., Dyo, V., & Nabakooza, S. (2024) · Sensors · doi:10.3390/s24113301 · Cited by 12
The Big Consequences of Small Discrepancies: Why Racial Differences in Pulse Oximetry Errors Matter
Holder, A. L., & Wong, A.-K. I. (2022) · Critical Care Medicine · doi:10.1097/ccm.0000000000005447 · Cited by 13
Silano, J. A. (2024) · Healthcare Management Forum · doi:10.1177/08404704241257144 · Cited by 12
Sharing is caring: A systematic review of publicly available intensive care data sets
Jagesar, A. R., Dam, T. A., Struja, T., Sauer, C. M., Otten, M., Biesheuvel, L. A., Girbes, A. R. J., Adhikari, L., Zhang, Z., Faltys, M., et al. (2025) · Journal of Critical Care · doi:10.1016/j.jcrc.2025.155205 · Cited by 13
Workforce solutions to address health disparities
Mhyre, J. M., Jackson, J., Lucero, J. M., & Goree, J. H. (2022) · Current Opinion in Anaesthesiology · doi:10.1097/aco.0000000000001147 · Cited by 13
Aoki, K. C., Barrant, M., Gai, M. J., Handal, M., Xu, V., & MAYROVITZ, H. N. (2023) · Cureus · doi:10.7759/cureus.46078 · Cited by 12
Early Warning Systems for Critical Illness Outside the Intensive Care Unit
Henry, K. E., & Giannini, H. M. (2024) · Critical Care Clinics · doi:10.1016/j.ccc.2024.03.007 · Cited by 13
Pulse Oximetry: 2023 Year in Review
HESS, D. R. (2024) · Respiratory Care · doi:10.4187/respcare.12023 · Cited by 13
Kalra, A., Wilcox, C. J., Holmes, S. D., Tonna, J. E., Jeong, I. S., Rycus, P. T., Anders, M. M., Zaaqoq, A. M., Lorusso, R., Brodie, D., et al. (2024) · Lung · doi:10.1007/s00408-024-00711-4 · Cited by 13
Weng, P., & Chang, W. (2022) · International Wound Journal · doi:10.1111/iwj.14053 · Cited by 11
Ren, S., Zupetic, J., Tabary, M., DeSensi, R., Nouraie, M. S., Lu, X., Boyce, R. D., & Lee, J. S. (2022) · Scientific Reports · doi:10.1038/s41598-022-12419-7 · Cited by 11
Oxygenation target in acute respiratory distress syndrome
Capellier, G., Barrot, L., & Winizewski, H. (2023) · Journal of Intensive Medicine · doi:10.1016/j.jointm.2023.03.002 · Cited by 11
Elron, E., Bromiker, R., Gleisner, O., Hay, O. Y., Goldberg, O., Nitzan, I., & Nitzan, M. (2023) · Sensors · doi:10.3390/s23031434 · Cited by 12
Al-Halawani, R., Qassem, M., & Kyriacou, P. A. (2025) · Sensors · doi:10.3390/s25020372 · Cited by 11
Patterson, S., Sandercock, N., & Verhovsek, M. M. (2022) · American Journal of Hematology · doi:10.1002/ajh.26721 · Cited by 9
Abe, T., Takagi, T., & Fujii, T. (2023) · Critical Care · doi:10.1186/s13054-023-04370-4 · Cited by 12
Disparities among patients with respiratory failure
Blank, J. A., Armstrong-Hough, M., & Valley, T. S. (2023) · Current Opinion in Critical Care · doi:10.1097/mcc.0000000000001079 · Cited by 13
Factores determinantes de la precisión de la oximetría de pulso: revisión bibliográfica
Valladares, D. L., Mateu, L. A. B., Cortés-Carmona, N., Fuentes-Lizana, G., Cabanas, A. M., Latorre-Progulakis, K., Fuentes‐Guajardo, M., & Martín-Escudero, P. (2024) · Revista Clínica Española · doi:10.1016/j.rce.2024.03.001 · Cited by 12
Jones, G. A. L., Wiegand, M., Ray, S., Gould, D. W., Agbeko, R., Giallongo, E., Charles, W. N., Orzol, M., O’Neill, L., Lampro, L., et al. (2024) · Pediatric Critical Care Medicine · doi:10.1097/pcc.0000000000003583 · Cited by 12
He, Y., Liu, W., Lin, S., Li, Z., Qiu, H., Yim, S. H. L., Chuang, H., & Ho, K. (2023) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2023.163969 · Cited by 9
Girolamo, T. M., Butler, L. K., Canale, R. R., Aslin, R. Ν., & Eigsti, I. (2023) · Neuropsychology Review · doi:10.1007/s11065-023-09618-y · Cited by 10
A Clinician’s Guide to Understanding Bias in Critical Clinical Prediction Models
de Matos, J. C. R. G., Gallifant, J., Chowdhury, A., Economou-Zavlanos, N., Charpignon, M., Gichoya, J. W., Celi, L. A., Nazer, L. H., King, H., & Wong, A.-K. I. (2024) · Critical Care Clinics · doi:10.1016/j.ccc.2024.05.011 · Cited by 11
Xiong, N. (2024) · American Journal of Translational Research · doi:10.62347/lckg5157 · Cited by 9
Shining Light on Dark Skin: Pulse Oximetry Correction Models
de Matos, J. C. R. G., Struja, T., Gallifant, J., Charpignon, M., Cardoso, J. S., & Celi, L. A. (2023) · IEEE Portuguese Meeting on Bioengineering · doi:10.1109/enbeng58165.2023.10175316 · Cited by 7
Modulation of the allosteric and vasoregulatory arms of erythrocytic oxygen transport
Wise, T. J., Ott, M. E., Joseph, M. S., Welsby, I. J., Darrow, C. C., & McMahon, T. J. (2024) · Frontiers in Physiology · doi:10.3389/fphys.2024.1394650 · Cited by 10
Diversity and inclusion: A hidden additional benefit of Open Data
Charpignon, M., Celi, L. A., Cobanaj, M., Eber, R., Fiske, A., Gallifant, J., Li, C., Lingamallu, G., Petushkov, A., & Pierce, R. L. (2024) · PLOS Digital Health · doi:10.1371/journal.pdig.0000486 · Cited by 8
Overt and Occult Hypoxemia in Patients Hospitalized With COVID-19
Gadrey, S. M., Mohanty, P., Haughey, S. P., Jacobsen, B. A., Dubester, K. J., Webb, K. M., Kowalski, R. L., Dreicer, J. J., Andris, R. T., Clark, M., et al. (2023) · Critical Care Explorations · doi:10.1097/cce.0000000000000825 · Cited by 8
Discrimination by Design: Is It Time to Recalibrate Interpretation of Pulse Oximetry?*
Barreto, J. A., & Moynihan, K. M. (2023) · Pediatric Critical Care Medicine · doi:10.1097/pcc.0000000000003229 · Cited by 8
He, Y., Liu, W., Lin, S., Li, Z., Qiu, H., Yim, S. H. L., Chuang, H., & Ho, K. (2023) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2023.166531 · Cited by 7
Can we predict the future of respiratory failure prediction?
Pearce, A. K., Nemati, S., Goligher, E. C., Hough, C. L., Holder, A. L., Wardi, G., Yang, P., Boussina, A. E., Lyons, P. G., Sahetya, S. K., et al. (2025) · Critical Care · doi:10.1186/s13054-025-05484-7 · Cited by 8
Pulse Oximetry Discrepancies and Occult Hypoxemia in ICU Patients: Predictors and Clinical Outcomes
Saidy, S. O., Iqbal, A., & Baig, S. H. (2025) · Journal of Intensive Care Medicine · doi:10.1177/08850666251351594 · Cited by 10
Metadata
- Authors
- Wong, A.-K. I., Charpignon, M., Kim, H., Josef, C., de Hond, A. A. H., Fojas, J. J., Tabaie, A., Liu, X., Mireles-Cabodevila, E., Carvalho, L., Kamaleswaran, R., Madushani, R. W. M. A., Adhikari, L., Holder, A. L., Steyerberg, E. W., Buchman, T. G., Lough, M. E., & Celi, L. A.
- Affiliations
- Emory University (US)
- Massachusetts Institute of Technology (US)
- Johns Hopkins University (US)
- Leiden University Medical Centre, Department of Biomedical Data Sciences, Leiden, the Netherlands
- Beth Israel Deaconess Medical Center (US)
- Beihang University (CN)
- School of Biological Science and Medical Engineering, Beihang University, Beijing, China
- Cleveland Clinic (US)
- Boston Medical Center (US)
- Philips (United States) (US)
- Leiden University Medical Center (NL)
- Stanford Health Care (US)
- Corresponding author
- Wong, An-Kwok Ian
- ORCID
- Venue
- JAMA Network Open
- Publisher
- American Medical Association (AMA)
- Published
- 2021-11-03
- Volume
- 4
- Issue
- 11
- Pages
- e2131674
- ISSN
- 2574-3805 (ISSN-L)
- PMC
- PMC9178439
- OpenAlex
- W3210241905
- Cited by
- 268
- References
- 25
- Citations by year
- 2026: 26 · 2025: 53 · 2024: 62 · 2023: 67 · 2022: 60
- FWCI
- 14.36
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- Locations
- JAMA Network Open (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Leiden Repository (Leiden University) (submittedVersion, cc-by)
- Data Archiving and Networked Services (DANS) (submittedVersion, cc-by)
- DSpace@MIT (Massachusetts Institute of Technology) (submittedVersion, cc-by-nc)
- Funders
- U.S. Department of Defense
- National Institutes of Health (5r01eb017205-07, R01-EB017205, EB017205, NIBIB R01 EB017205, UL1TR002378)
- Uniformed Services University of the Health Sciences (HT9404-13-1-0032, HU0001, USUHS HT9404-13-1-0032, HU0001-15-2-0001)
- Biomedical Advanced Research and Development Authority
- National Institute of General Medical Sciences (K23GM137182, T32GM095442, R01GM139967)
- National Institute of Biomedical Imaging and Bioengineering (NIBIB R01 EB017205, R01-EB017205, EB017205)
- National Center for Advancing Translational Sciences
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
- Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Sepsis Diagnosis and Treatment
- Keywords
- pulse oximetry, arterial oxygen saturation, racial and ethnic disparities, arterial blood gases, intensive care unit patients, organ dysfunction, SOFA score, in-hospital mortality, length of hospital stay, lactate, creatinine, Black patients, Hispanic patients, health disparities, hypoxemia detection
- MeSH terms
- Oxygen Saturation, Aged, Hypoxia, Creatinine, Cross-Sectional Studies, Ethnicity, Female, Georgia, Humans, Male, Middle Aged, Multiple Organ Failure, Oximetry, Retrospective Studies, Racial Groups
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review