Analysis of Discrepancies between Pulse Oximetry and Arterial Oxygen Saturation Measurements by Race and Ethnicity and Association with Organ Dysfunction and Mortality
Open accessAbstract
Importance: Discrepancies in oxygen saturation measured by pulse oximetry (Spo2), when compared with arterial oxygen saturation (Sao2) measured by arterial blood gas (ABG), may differentially affect patients according to race and ethnicity. However, the association of these disparities with health outcomes is unknown. Objective: To examine racial and ethnic discrepancies between Sao2 and Spo2 measures and their associations with clinical outcomes. Design, Setting, and Participants: This multicenter, retrospective, cross-sectional study included 3 publicly available electronic health record (EHR) databases (ie, the Electronic Intensive Care Unit-Clinical Research Database and Medical Information Mart for Intensive Care III and IV) as well as Emory Healthcare (2014-2021) and Grady Memorial (2014-2020) databases, spanning 215 hospitals and 382 ICUs. From 141 600 hospital encounters with recorded ABG measurements, 87 971 participants with first ABG measurements and an Spo2 of at least 88% within 5 minutes before the ABG test were included. Exposures: Patients with hidden hypoxemia (ie, Spo2 ≥88% but Sao2 <88%). Main Outcomes and Measures: Outcomes, stratified by race and ethnicity, were Sao2 for each Spo2, hidden hypoxemia prevalence, initial demographic characteristics (age, sex), clinical outcomes (in-hospital mortality, length of stay), organ dysfunction by scores (Sequential Organ Failure Assessment [SOFA]), and laboratory values (lactate and creatinine levels) before and 24 hours after the ABG measurement. Results: The first Spo2-Sao2 pairs from 87 971 patient encounters (27 713 [42.9%] women; mean [SE] age, 62.2 [17.0] years; 1919 [2.3%] Asian patients; 26 032 [29.6%] Black patients; 2397 [2.7%] Hispanic patients, and 57 632 [65.5%] White patients) were analyzed, with 4859 (5.5%) having hidden hypoxemia. Hidden hypoxemia was observed in all subgroups with varying incidence (Black: 1785 [6.8%]; Hispanic: 160 [6.0%]; Asian: 92 [4.8%]; White: 2822 [4.9%]) and was associated with greater organ dysfunction 24 hours after the ABG measurement, as evidenced by higher mean (SE) SOFA scores (7.2 [0.1] vs 6.29 [0.02]) and higher in-hospital mortality (eg, among Black patients: 369 [21.1%] vs 3557 [15.0%]; P < .001). Furthermore, patients with hidden hypoxemia had higher mean (SE) lactate levels before (3.15 [0.09] mg/dL vs 2.66 [0.02] mg/dL) and 24 hours after (2.83 [0.14] mg/dL vs 2.27 [0.02] mg/dL) the ABG test, with less lactate clearance (-0.54 [0.12] mg/dL vs -0.79 [0.03] mg/dL). Conclusions and Relevance: In this study, there was greater variability in oxygen saturation levels for a given Spo2 level in patients who self-identified as Black, followed by Hispanic, Asian, and White. Patients with and without hidden hypoxemia were demographically and clinically similar at baseline ABG measurement by SOFA scores, but those with hidden hypoxemia subsequently experienced higher organ dysfunction scores and higher in-hospital mortality.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Overestimated SpO2 readings in patients with darker skin pigmentation lead to lower hospital admission, higher occult hypoxemia, delayed or no access to dexamethasone, therapeutic oxygen, and COVID-19 therapies, resulting in increased hospital readmission, organ dysfunction, and mortality.
“leading to lower hospital admission; higher occult hypoxemia; and delayed or no access to dexamethasone, therapeutic oxygen, and COVID-19 therapies, resulting in increased hospital readmission, organ dysfunction, and mortality [11-18].”
From Impact of skin pigmentation on pulse oximetry blood oxygenation and wearable pulse rate accuracy: systematic review and meta-analysis (2024) · cites this paper as [15]
Split into 2 atoms — 0 confirmed, 2 partially supported, 0 disputed, 0 misattributed, 0 unverifiable. Expand the claim to see per-atom verdicts.
Experimental — accuracy not yet measuredPatients with darker skin pigmentation are more likely than patients with lighter skin color to have overestimated SpO2 readings.
“Patients with darker skin pigmentation are more likely than patients with lighter skin color to have overestimated SpO2 readings”
From Impact of skin pigmentation on pulse oximetry blood oxygenation and wearable pulse rate accuracy: systematic review and meta-analysis (2024) · cites this paper as [15]
More recent studies have revealed that dark skin pigmentation influences the accuracy and performance of pulse oximeter devices, resulting in overestimations, with increased incidence in the risk for occult hypoxemia (SO2<88% despite normal SpO2>92%).
“More recent studies have also revealed that dark skin pigmentation influences the accuracy and performance of pulse oximeters devices, resulting in overestimations [17,49,50,51,52,53] with increased incidence in the risk for occult hypoxemia (SO2<88% despite normal SpO2>92%) [54,55].”
From Skin pigmentation influence on pulse oximetry accuracy: a systematic review and bibliometric analysis (2022) · cites this paper as [54]
Recent studies have shown a positive bias in oxygen saturation measurements in patients with darkly pigmented skin, particularly under low saturation conditions.
“Recent studies have shown a positive bias in oxygen saturation measurements in patients with darkly pigmented skin, particularly under low saturation conditions.”
From Skin pigmentation influence on pulse oximetry accuracy: a systematic review and bibliometric analysis (2022) · cites this paper as [54]
Several health organizations and healthcare professionals have raised growing concerns about the clinical accuracy of pulse oximetry in dark-skinned patients, particularly in detecting occult hypoxemia.
“Due to this increasing evidence, several health organizations and healthcare professionals have raised growing concerns about the clinical accuracy of pulse oximetry in dark-skinned patients [20,57,58,59,60,61], particularly in detecting occult hypoxemia [54,55].”
From Skin pigmentation influence on pulse oximetry accuracy: a systematic review and bibliometric analysis (2022) · cites this paper as [54]
A prevalence of occult hypoxemia in dark-skinned subjects has been recently confirmed in three studies, showing that dark-skinned patients may have over three times the risk of experiencing occult hypoxemia during hospitalization compared to light-skinned patients.
“A prevalence of occult hypoxemia in dark-skinned subjects has been recently confirmed in three studies, showing that dark-skinned patients may have over three times the risk of experiencing occult hypoxemia during hospitalization compared to light-skinned patients [53,54,55].”
From Skin pigmentation influence on pulse oximetry accuracy: a systematic review and bibliometric analysis (2022) · cites this paper as [54]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809 · see citing works
Vincent, J. L., Moreno, R., Takala, J., Willatts, S., De Mendonça, A., Bruining, H., Reinhart, C. K., Suter, P. M., & Thijs, L. G. (1996) · Intensive Care Medicine · doi:10.1007/bf01709751 · Cited by 11,674 · see citing works
MIMIC-III, a freely accessible critical care database
Johnson, A. E. W., Pollard, T. J., Shen, L., Lehman, L.-W. H., Feng, M., Ghassemi, M., Moody, B., Szolovits, P., Anthony Celi, L., & Mark, R. G. (2016) · Scientific Data · doi:10.1038/sdata.2016.35 · Cited by 8,141 · see citing works
Vandenbroucke, J. P., Elm, E. V., Altman, D. G., Gøtzsche, P. C., Mulrow, C. D., Pocock, S. J., Poole, C., Schlesselman, J. J., Egger, M., & initiative, F. T. S. (2007) · Annals of Internal Medicine · doi:10.7326/0003-4819-147-8-200710160-00010-w1 · Cited by 3,543 · see citing works
The Triad of Sleep Apnea, Hypertension, and Chronic Kidney Disease: A Spectrum of Common Pathology
Aziz, F., & Chaudhary, K. R. (2016) · Cardiorenal Medicine · doi:10.1159/000450796 · Cited by 3,285 · see citing works
Pollard, T. J., Johnson, A. E. W., Raffa, J. D., Celi, L. A., Mark, R. G., & Badawi, O. (2018) · Scientific Data · doi:10.1038/sdata.2018.178 · Cited by 1,993 · see citing works
Racial bias in pulse oximetry measurement
Sjoding, M. W., Dickson, R. P., Iwashyna, T. J., Gay, S. E., & Valley, T. S. (2020) · New England Journal of Medicine · doi:10.1056/nejmc2029240 · Cited by 1,114 · see citing works
Jansen, T. C., van Bommel, J., Schoonderbeek, F. J., Sleeswijk Visser, S. J., van der Klooster, J. M., Lima, A. P., Willemsen, S. P., & Bakker, J. (2010) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200912-1918oc · Cited by 894 · see citing works
Intermittent Hypoxemia and OSA
Dewan, N. A., Nieto, F. J., & Somers, V. K. (2015) · Chest · doi:10.1378/chest.14-0500 · Cited by 641 · see citing works
Effects of skin pigmentation on pulse oximeter accuracy at low saturation
Bickler, P. E., Feiner, J. R., & Severinghaus, J. W. (2005) · Anesthesiology · doi:10.1097/00000542-200504000-00004 · Cited by 427 · see citing works
Feiner, J. R., Severinghaus, J. W., & Bickler, P. E. (2007) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000285988.35174.d9 · Cited by 400 · see citing works
Kidney physiology and susceptibility to acute kidney injury: implications for renoprotection
Scholz, H., Boivin, F. J., Schmidt-Ott, K. M., Bachmann, S., Eckardt, K., Scholl, U. I., & Persson, P. B. (2021) · Nature Reviews Nephrology · doi:10.1038/s41581-021-00394-7 · Cited by 328 · see citing works
The SOFA (Sepsis-related Organ Failure Assessment) score to describe organ dysfunction/failure
Vincent, J., Moreno, R. P., Takala, J. A., et al. (1996) · Intensive Care Medicine · doi:10.1007/s001340050156 · Cited by 314 · see citing works
Accuracy of pulse oximetry in the intensive care unit
de Louw, A. V., Cracco, C., Cerf, C., HARF, A., Duvaldestin, P., Lemaire, F., & Brochard, L. J. (2001) · Intensive Care Medicine · doi:10.1007/s001340101064 · Cited by 307 · see citing works
Kruse, O., Grunnet, N., & Barfod, C. (2011) · Scandinavian Journal of Trauma Resuscitation and Emergency Medicine · doi:10.1186/1757-7241-19-74 · Cited by 303 · see citing works
Wilson, B., Cowan, H. J., Lord, J. A., Zuege, D. J., & Zygun, D. A. (2010) · BMC Emergency Medicine · doi:10.1186/1471-227x-10-9 · Cited by 146 · see citing works
Perkins, G. D., McAuley, D. F., Giles, S., Routledge, H., & Gao, F. (2003) · Critical Care · doi:10.1186/cc2339 · Cited by 136 · see citing works
Hypoxia and Mucosal Inflammation
Colgan, S. P., Campbell, E. L., & Kominsky, D. J. (2016) · Annual Review of Pathology Mechanisms of Disease · doi:10.1146/annurev-pathol-012615-044231 · Cited by 133 · see citing works
Tissue Hypoxia: Implications for the Respiratory Clinician
MacIntyre, N. R. (2014) · Respiratory Care · doi:10.4187/respcare.03357 · Cited by 121 · see citing works
Bickler, P. E., Feiner, J., Lipnick, M. S., Batchelder, P. B., MacLeod, D. B., & Severinghaus, J. W. (2016) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000001421 · Cited by 88 · see citing works
Evidence for the need of bedside accuracy of pulse oximetry in an intensive care unit
Séguin, P., Rouzo, A. L., Tanguy, M., Guillou, Y. M., Feuillu, A., & Mallédant, Y. (2000) · Critical Care Medicine · doi:10.1097/00003246-200003000-00017 · Cited by 72 · see citing works
Coustet, B., Lhuissier, F., Vincent, R., & Richalet, J. (2015) · Circulation · doi:10.1161/circulationaha.114.013144 · Cited by 48 · see citing works
Singh, A. (2017) · JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH · doi:10.7860/jcdr/2017/24640.9961 · Cited by 45 · see citing works
Blum, F. E., Lund, E. T., Hall, H. A., Tachauer, A. D., Chedrawy, E. G., & Zilberstein, J. (2014) · Journal of Critical Care · doi:10.1016/j.jcrc.2014.10.025 · Cited by 37 · see citing works
Vandenbroucke, J. P., von Elm, E. B., Altman, D. G., Gøtzsche, P. C., Mulrow, C. D., Pocock, S., Poole, C., Schlesselman, J. J., & Egger, M. (2021) · Digital Diagnostics · doi:10.17816/dd70821 · Cited by 18 · see citing works
Singh, A., & Singh, M. (2017) · doi:10.1183/1393003.congress-2017.pa2127 · Cited by 3 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
A New Global Definition of Acute Respiratory Distress Syndrome
Matthay, M. A., Arabi, Y. M., Arroliga, A. C., Bernard, G. R., Bersten, A. D., Brochard, L. J., Calfee, C. S., Combes, A., Daniel, B. M., Ferguson, N. D., et al. (2023) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.202303-0558ws · Cited by 883 · see citing works
Porsbjerg, C. M., Melén, E., Lehtimäki, L. A., & Shaw, D. E. (2023) · The Lancet · doi:10.1016/s0140-6736(22)02125-0 · Cited by 586 · see citing works
Fawzy, A., Wu, T. D., Wang, K., Robinson, M. L., Farha, J., Bradke, A., Golden, S. H., Xu, Y., & Garibaldi, B. T. (2022) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2022.1906 · Cited by 326 · see citing works
Wearable Photoplethysmography for Cardiovascular Monitoring
Charlton, P. H., Kyriacou, P. A., Mant, J., Marozas, V., Chowienczyk, P., & Alastruey, J. (2022) · Proceedings of the IEEE · doi:10.1109/jproc.2022.3149785 · Cited by 250 · see citing works
The Sequential Organ Failure Assessment (SOFA) Score: has the time come for an update?
Moreno, R. P., Rhodes, A., Piquilloud, L., Glenn Hernández, P., Takala, J. A., Gershengorn, H. B., Tavares, M., Coopersmith, C. M., Myatra, S. N., Singer, M., et al. (2023) · Critical Care · doi:10.1186/s13054-022-04290-9 · Cited by 258 · see citing works
Greif, R. T., Bray, J., Djärv, T., Drennan, I. R., Liley, H. G., Ng, K.-C., Cheng, A., Douma, M. J., Scholefield, B. R., Smyth, M. A., et al. (2024) · Circulation · doi:10.1161/cir.0000000000001288 · Cited by 177 · see citing works
Leveraging electronic health records for data science: common pitfalls and how to avoid them
Sauer, C. M., Chen, L.-C., Hyland, S. L., Girbes, A. R. J., Elbers, P., & Celi, L. A. (2022) · The Lancet Digital Health · doi:10.1016/s2589-7500(22)00154-6 · Cited by 173 · see citing works
Berg, K. M., Bray, J., Ng, K.-C., Liley, H. G., Greif, R., Carlson, J. N., Morley, P. T., Drennan, I. R., Smyth, M. A., Scholefield, B. R., et al. (2023) · Circulation · doi:10.1161/cir.0000000000001179 · Cited by 177 · see citing works
Shi, C., Goodall, M., Dumville, J., Hill, J., Norman, G., Hamer, O., Clegg, A., Watkins, C. L., Georgiou, G., Hodkinson, A., et al. (2022) · doi:10.1101/2022.02.16.22271062 · Cited by 158 · see citing works
Gottlieb, E. R., Ziegler, J., Morley, K., Rush, B., & Celi, L. A. (2022) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2022.2587 · Cited by 134 · see citing works
Valbuena, V. S. M., Seelye, S., Sjoding, M. W., Valley, T. S., Dickson, R. P., Gay, S. E., Claar, D., Prescott, H. C., & Iwashyna, T. J. (2022) · BMJ · doi:10.1136/bmj-2021-069775 · Cited by 127 · see citing works
Cabanas, A. M., Fuentes-Guajardo, M., Latorre, K., León, D., & Martín-Escudero, P. (2022) · Sensors · doi:10.3390/s22093402 · Cited by 124 · see citing works
A review of the effect of skin pigmentation on pulse oximeter accuracy
Al-Halawani, R., Charlton, P. H., Qassem, M., & Kyriacou, P. A. (2023) · Physiological Measurement · doi:10.1088/1361-6579/acd51a · Cited by 119 · see citing works
Wearable Photoplethysmography for Cardiovascular Monitoring.
Charlton, P. H., Kyriacou, P. A., Mant, J., Marozas, V., Chowienczyk, P., & Alastruey, J. (2022) · KTUePubl (Repository of Kaunas University of Technology) · doi:10.17863/cam.81148 · Cited by 113 · see citing works
Berg, K. M., Bray, J., Ng, K.-C., Liley, H. G., Greif, R., Carlson, J. N., Morley, P. T., Drennan, I. R., Smyth, M. A., Scholefield, B. R., et al. (2023) · Resuscitation · doi:10.1016/j.resuscitation.2023.109992 · Cited by 117 · see citing works
Hirsch, K. G., Amorim, E., Coppler, P. J., Drennan, I. R., Elliott, A., Gordon, A. J., Jentzer, J. C., Johnson, N. J., Moskowitz, A., Mumma, B. E., et al. (2025) · Circulation · doi:10.1161/cir.0000000000001375 · Cited by 110 · see citing works
Assessment of ownership of smart devices and the acceptability of digital health data sharing
Shandhi, M. M. H., Singh, K., Janson, N., Ashar, P., Singh, G., Lu, B., Hillygus, D. S., Maddocks, J., & Dunn, J. (2024) · npj Digital Medicine · doi:10.1038/s41746-024-01030-x · Cited by 92 · see citing works
Greif, R. T., Bray, J., Djärv, T., Drennan, I. R., Liley, H. G., Ng, K.-C., Cheng, A., Douma, M. J., Scholefield, B. R., Smyth, M., et al. (2024) · Resuscitation · doi:10.1016/j.resuscitation.2024.110414 · Cited by 89 · see citing works
Racial Disparity in Oxygen Saturation Measurements by Pulse Oximetry: Evidence and Implications
Jamali, H., Castillo, L. T., Morgan, C. C., Coult, J., Muhammad, J. L., Osobamiro, O. O., Parsons, E. C., & Adamson, R. (2022) · Annals of the American Thoracic Society · doi:10.1513/annalsats.202203-270cme · Cited by 83 · see citing works
Martín, D., Johns, C., Sorrell, L., Healy, E., Phull, M., Olusanya, O., Peters, M. J., & Fabes, J. (2024) · British Journal of Anaesthesia · doi:10.1016/j.bja.2024.01.023 · Cited by 80 · see citing works
Gudelunas, M. K., Lipnick, M. S., Hendrickson, C. M., Vanderburg, S. B., Okunlola, B., Auchus, I., Feiner, J., & Bickler, P. E. (2023) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000006755 · Cited by 68 · see citing works
Sudat, S. E. K., Wesson, P., Rhoads, K. F., Brown, S., Aboelata, N., Pressman, A. R., Mani, A., & Azar, K. M. J. (2022) · American Journal of Epidemiology · doi:10.1093/aje/kwac164 · Cited by 58 · see citing works
Fawzy, A., Wu, T. D., Wang, K., Sands, K. E., Fisher, A. M., Arnold Egloff, S. A., DellaVolpe, J. D., Iwashyna, T. J., Xu, Y., & Garibaldi, B. T. (2023) · JAMA Network Open · doi:10.1001/jamanetworkopen.2023.30856 · Cited by 50 · see citing works
Inherent Bias in Electronic Health Records: A Scoping Review of Sources of Bias
Perets, O., Stagno, E., Yehuda, E. B., McNichol, M. C., Celi, L. A., Rappoport, N., & Dorotić, M. (2025) · ACM Transactions on Intelligent Systems and Technology · doi:10.1145/3757924 · Cited by 59 · see citing works
Helms, J., Catoire, P., Vuillaume, L. A., Bannelier, H., Douillet, D., Dupuis, C., Federici, L., Jezequel, M., Jozwiak, M., Kuteifan, K., et al. (2024) · Annals of Intensive Care · doi:10.1186/s13613-024-01367-2 · Cited by 53 · see citing works
Melanometry for objective evaluation of skin pigmentation in pulse oximetry studies
Vasudevan, S., Vogt, W. C., Weininger, S., & Pfefer, T. J. (2024) · Communications Medicine · doi:10.1038/s43856-024-00550-7 · Cited by 46 · see citing works
Disparity dashboards: an evaluation of the literature and framework for health equity improvement
Gallifant, J., Kistler, E. A., Nakayama, L. F., Zera, C., Kripalani, S. B., Ntatin, A., Fernández, L., Bates, D. W., Dankwa‐Mullan, I., & Celi, L. A. (2023) · The Lancet Digital Health · doi:10.1016/s2589-7500(23)00150-4 · Cited by 45 · see citing works
Skin Assessment in Patients with Dark Skin Tone
Pusey‐Reid, E., Quinn, L., Samost, M. E., & Reidy, P. A. (2023) · AJN American Journal of Nursing · doi:10.1097/01.naj.0000921800.61980.7e · Cited by 42 · see citing works
Accuracy of Multiple Pulse Oximeters in Stable Critically Ill Patients
Blanchet, M.-A., Mercier, G., Delobel, A., Nayet, E., Bouchard, P.-A., Simard, S., L’Her, E., Branson, R. D., & Lellouche, F. (2023) · Respiratory Care · doi:10.4187/respcare.10582 · Cited by 42 · see citing works
de Hond, A., van Buchem, M. M., & Hernandez‐Boussard, T. (2022) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocac156 · Cited by 40 · see citing works
Admission vital signs as predictors of COVID-19 mortality: a retrospective cross-sectional study
Ikram, A. S., & Pillay, S. (2022) · BMC Emergency Medicine · doi:10.1186/s12873-022-00631-7 · Cited by 39 · see citing works
Critical Bias in Critical Care Devices
Charpignon, M.-L., Byers, J., Cabral, S., Celi, L. A., Fernandes, C., Gallifant, J., Lough, M. E., Mlombwa, D., Moukheiber, L., Ong, B. A., et al. (2023) · Critical Care Clinics · doi:10.1016/j.ccc.2023.02.005 · Cited by 35 · see citing works
Skin colour affects the accuracy of medical oxygen sensors
Keller, M. D., Harrison-Smith, B., Patil, C., & Arefin, M. S. (2022) · Nature · doi:10.1038/d41586-022-03161-1 · Cited by 38 · see citing works
Racial and Ethnic Bias in Pulse Oximetry and Clinical Outcomes
Valbuena, V. S. M., Merchant, R. M., & Hough, C. L. (2022) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2022.1903 · Cited by 37 · see citing works
Marinari, S., Volpe, P., Simoni, M., Aventaggiato, M., Benedetto, F. D., Nardini, S. G., Sanguinetti, C. M., & Palange, P. (2022) · Sensors · doi:10.3390/s22135031 · Cited by 38 · see citing works
Singh, S., Bennett, M. R., Chen, C., Shin, S., Ghanbari, H., & Nelson, B. W. (2024) · Journal of Medical Internet Research · doi:10.2196/62769 · Cited by 36 · see citing works
Investigating the accuracy of blood oxygen saturation measurements in common consumer smartwatches
Jiang, Y., Spies, C., Magin, J., Bhosai, S. J., Snyder, L., & Dunn, J. (2023) · PLOS Digital Health · doi:10.1371/journal.pdig.0000296 · Cited by 36 · see citing works
Chesley, C. F., Lane-Fall, M. B., Panchanadam, V., Harhay, M. O., Wani, A. A., Mikkelsen, M. E., & Fuchs, B. D. (2022) · Respiratory Care · doi:10.4187/respcare.09769 · Cited by 36 · see citing works
Racial effects on Masimo pulse oximetry: a laboratory study
Barker, S. J., & Wilson, W. C. (2023) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-022-00927-w · Cited by 36 · see citing works
Sjoding, M. W., Iwashyna, T. J., & Valley, T. S. (2022) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.202209-1773ed · Cited by 29 · see citing works
Skin Pigmentation and Pulse Oximeter Accuracy in the Intensive Care Unit: A Pilot Prospective Study
Fawzy, A., Ali, H., Dziedzic, P. H., Potu, N., Calvillo, E., Golden, S. H., Iwashyna, T. J., Suárez, J. I., Hager, D. N., & Garibaldi, B. T. (2024) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.202401-0036le · Cited by 28 · see citing works
Cabanas, A. M., Martín-Escudero, P., & Shelley, K. H. (2023) · British Journal of Anaesthesia · doi:10.1016/j.bja.2023.07.005 · Cited by 28 · see citing works
Representation of dark skin tones in foundational nursing textbooks: An image analysis
Pusey‐Reid, E., Quinn, L. W., Wong, J. W., & Wucherpfennig, A. (2023) · Nurse Education Today · doi:10.1016/j.nedt.2023.105927 · Cited by 28 · see citing works
Racial and skin color mediated disparities in pulse oximetry in infants and young children
Sharma, M., Brown, A. W., Powell, N. M., Rajaram, N., Tong, L., Mourani, P. M., & Schootman, M. (2024) · Paediatric Respiratory Reviews · doi:10.1016/j.prrv.2023.12.006 · Cited by 28 · see citing works
Kyriacou, P. A., Charlton, P. H., Al-Halawani, R., & Shelley, K. H. (2022) · British Journal of Anaesthesia · doi:10.1016/j.bja.2022.03.011 · Cited by 27 · see citing works
Pulse Oximetry and Race in Critically Ill Adults
Seitz, K. P., Wang, L., Casey, J. D., Markus, S. A., Jackson, K. E., Qian, E. T., Self, W. H., Rice, T. W., & Semler, M. W. (2022) · Critical Care Explorations · doi:10.1097/cce.0000000000000758 · Cited by 28 · see citing works
Melanin bias in pulse oximetry explained by light source spectral bandwidth
Bierman, A., Benner, K. J., & Rea, M. S. (2024) · British Journal of Anaesthesia · doi:10.1016/j.bja.2024.01.037 · Cited by 24 · see citing works
Parr, N. J., Beech, E. H., Young, S., & Valley, T. S. (2024) · Journal of General Internal Medicine · doi:10.1007/s11606-024-08852-1 · Cited by 21 · see citing works
Hess, M. W. (2023) · Respiratory Care · doi:10.4187/respcare.10876 · Cited by 21 · see citing works
Retinal Scans and Data Sharing: The Privacy and Scientific Development Equilibrium
Nakayama, L. F., de Matos, J. C. R. G., Stewart, I. U., Mitchell, W. G., Martinez‐Martin, N., Regatieri, C. V., & Celi, L. A. (2023) · Mayo Clinic Proceedings Digital Health · doi:10.1016/j.mcpdig.2023.02.003 · Cited by 21 · see citing works
Participant flow diagrams for health equity in AI
Ellen, J., de Matos, J. C. R. G., Viola, M., Gallifant, J., Quion, J. M., Celi, L. A., & Hussein, N. S. A. (2024) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2024.104631 · Cited by 22 · see citing works
Utility of Skin Tone on Pulse Oximetry in Critically Ill Patients: A Prospective Cohort Study
Hao, S., Dempsey, K., de Matos, J. C. R. G., Cox, C. E., Rotemberg, V. M., Gichoya, J. W., Kibbe, W. A., Hong, C., & Wong, A.-K. I. (2024) · Critical Care Explorations · doi:10.1097/cce.0000000000001133 · Cited by 18 · see citing works
High risk and low prevalence diseases: Acute chest syndrome in sickle cell disease
Koehl, J. L., Koyfman, A., Hayes, B. D., & Long, B. (2022) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2022.06.018 · Cited by 19 · see citing works
Remote Hub Lab – RHL: Broadly Accessible Technologies for Education and Telehealth
Hussein, R., Chap, B., Inoñan, M., Guo, M., Monroy, F. L., Maloney, R. C., Ferreria, S. A., & Kalisi, S. J. (2023) · Lecture notes in networks and systems · doi:10.1007/978-3-031-42467-0_7 · Cited by 18 · see citing works
Alrawashdeh, M., Klompas, M., & Rhee, C. (2024) · Critical Care Medicine · doi:10.1097/ccm.0000000000006338 · Cited by 17 · see citing works
Origins of Racial and Ethnic Bias in Pulmonary Technologies
Sjoding, M. W., Ansari, S., & Valley, T. S. (2022) · Annual Review of Medicine · doi:10.1146/annurev-med-043021-024004 · Cited by 18 · see citing works
Herbst, A., Goel, S., Beane, A., Brotherton, B. J., Dula, D., Ely, E. W., Gordon, S. B., Haniffa, R., Hedt‐Gauthier, B., Limbani, F., et al. (2023) · Frontiers in Medicine · doi:10.3389/fmed.2023.1148334 · Cited by 17 · see citing works
Pulse oximetry values from 33,080 participants in the Apple Heart & Movement Study
Shapiro, I., Stein, J., MacRae, C. A., & OReilly, M. (2023) · npj Digital Medicine · doi:10.1038/s41746-023-00851-6 · Cited by 18 · see citing works
Kalra, A., Shou, B. L., Zhao, D. X., Wilcox, C. J., Keller, S. P., Kim, B. S., Whitman, G. J. R., Cho, S., Leng, A., Geeza, A., et al. (2023) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2023.09.019 · Cited by 14 · see citing works
Determining factors of pulse oximetry accuracy: a literature review
Valladares, D. L., Mateu, L. A. B., Cortés-Carmona, N., Fuentes-Lizana, G., Cabanas, A. M., Latorre-Progulakis, K., Fuentes‐Guajardo, M., & Martín-Escudero, P. (2024) · Revista Clínica Española (English Edition) · doi:10.1016/j.rceng.2024.04.005 · Cited by 18 · see citing works
Pulse oximetry in pediatric care: Balancing advantages and limitations
Al‐Beltagi, M., Saeed, N. K., Bediwy, A. S., & Elbeltagi, R. M. (2024) · World Journal of Clinical Pediatrics · doi:10.5409/wjcp.v13.i3.96950 · Cited by 19 · see citing works
Verma, A. A., Trbovich, P., Mamdani, M., & Shojania, K. G. (2023) · BMJ Quality & Safety · doi:10.1136/bmjqs-2022-015713 · Cited by 16 · see citing works
Ewerlöf, M., Strömberg, T., Larsson, M., & Salerud, E. G. (2022) · Journal of Biomedical Optics · doi:10.1117/1.jbo.27.3.036004 · Cited by 15 · see citing works
Kalra, A., Shou, B. L., Zhao, D. X., Wilcox, C. J., Keller, S. P., Whitman, G. J. R., Kim, B. S., Cho, S., Calligy, K., Brown, P., et al. (2023) · JTCVS Open · doi:10.1016/j.xjon.2023.02.011 · Cited by 12 · see citing works
Charpignon, M., Carrel, A., Jiang, Y., Kwaga, T., Cantada, B., Hyslop, T., Cox, C. E., Haines, K., Koomson, V. J., Dumas, G., et al. (2023) · PLOS Digital Health · doi:10.1371/journal.pdig.0000244 · Cited by 16 · see citing works
A new tool for evaluating health equity in academic journals; the Diversity Factor
Gallifant, J., Zhang, J., Whebell, S. F., Quion, J., Escobar, B., Gichoya, J. W., Herrera, K. V., Jina, R., Chidambaram, S., Mehndiratta, A., et al. (2023) · PLOS Global Public Health · doi:10.1371/journal.pgph.0002252 · Cited by 14 · see citing works
The Global Definition of Acute Respiratory Distress Syndrome: Ready for Prime Time?
Smit, M. R., Brower, R. G., Parsons, P. E., Phua, J., & Bos, L. D. J. (2023) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.202308-1369ed · Cited by 14 · see citing works
Racial effects on masimo pulse oximetry: impact of low perfusion index
Sharma, V., Barker, S. J., Sorci, R., Park, L., & Wilson, W. C. (2024) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-023-01113-2 · Cited by 14 · see citing works
Garnet, B., Lankenau, R. D., Jean, E., & Campos, M. (2023) · Annals of the American Thoracic Society · doi:10.1513/annalsats.202209-837oc · Cited by 15 · see citing works
Haxha, S., Nwibor, C., Ali, M., Sakel, M., Saunders, K., Dyo, V., & Nabakooza, S. (2024) · Sensors · doi:10.3390/s24113301 · Cited by 12 · see citing works
The Big Consequences of Small Discrepancies: Why Racial Differences in Pulse Oximetry Errors Matter
Holder, A. L., & Wong, A.-K. I. (2022) · Critical Care Medicine · doi:10.1097/ccm.0000000000005447 · Cited by 13 · see citing works
Sharing is caring: A systematic review of publicly available intensive care data sets
Jagesar, A. R., Dam, T. A., Struja, T., Sauer, C. M., Otten, M., Biesheuvel, L. A., Girbes, A. R. J., Adhikari, L., Zhang, Z., Faltys, M., et al. (2025) · Journal of Critical Care · doi:10.1016/j.jcrc.2025.155205 · Cited by 13 · see citing works
Workforce solutions to address health disparities
Mhyre, J. M., Jackson, J., Lucero, J. M., & Goree, J. H. (2022) · Current Opinion in Anaesthesiology · doi:10.1097/aco.0000000000001147 · Cited by 12 · see citing works
Aoki, K. C., Barrant, M., Gai, M. J., Handal, M., Xu, V., & MAYROVITZ, H. N. (2023) · Cureus · doi:10.7759/cureus.46078 · Cited by 12 · see citing works
Early Warning Systems for Critical Illness Outside the Intensive Care Unit
Henry, K. E., & Giannini, H. M. (2024) · Critical Care Clinics · doi:10.1016/j.ccc.2024.03.007 · Cited by 13 · see citing works
Pulse Oximetry: 2023 Year in Review
HESS, D. R. (2024) · Respiratory Care · doi:10.4187/respcare.12023 · Cited by 13 · see citing works
Kalra, A., Wilcox, C. J., Holmes, S. D., Tonna, J. E., Jeong, I. S., Rycus, P. T., Anders, M. M., Zaaqoq, A. M., Lorusso, R., Brodie, D., et al. (2024) · Lung · doi:10.1007/s00408-024-00711-4 · Cited by 13 · see citing works
Weng, P., & Chang, W. (2022) · International Wound Journal · doi:10.1111/iwj.14053 · Cited by 11 · see citing works
Ren, S., Zupetic, J., Tabary, M., DeSensi, R., Nouraie, M. S., Lu, X., Boyce, R. D., & Lee, J. S. (2022) · Scientific Reports · doi:10.1038/s41598-022-12419-7 · Cited by 11 · see citing works
Oxygenation target in acute respiratory distress syndrome
Capellier, G., Barrot, L., & Winizewski, H. (2023) · Journal of Intensive Medicine · doi:10.1016/j.jointm.2023.03.002 · Cited by 11 · see citing works
Elron, E., Bromiker, R., Gleisner, O., Hay, O. Y., Goldberg, O., Nitzan, I., & Nitzan, M. (2023) · Sensors · doi:10.3390/s23031434 · Cited by 11 · see citing works
Al-Halawani, R., Qassem, M., & Kyriacou, P. A. (2025) · Sensors · doi:10.3390/s25020372 · Cited by 11 · see citing works
Patterson, S., Sandercock, N., & Verhovsek, M. M. (2022) · American Journal of Hematology · doi:10.1002/ajh.26721 · Cited by 9 · see citing works
Abe, T., Takagi, T., & Fujii, T. (2023) · Critical Care · doi:10.1186/s13054-023-04370-4 · Cited by 11 · see citing works
Disparities among patients with respiratory failure
Blank, J. A., Armstrong-Hough, M., & Valley, T. S. (2023) · Current Opinion in Critical Care · doi:10.1097/mcc.0000000000001079 · Cited by 12 · see citing works
Factores determinantes de la precisión de la oximetría de pulso: revisión bibliográfica
Valladares, D. L., Mateu, L. A. B., Cortés-Carmona, N., Fuentes-Lizana, G., Cabanas, A. M., Latorre-Progulakis, K., Fuentes‐Guajardo, M., & Martín-Escudero, P. (2024) · Revista Clínica Española · doi:10.1016/j.rce.2024.03.001 · Cited by 11 · see citing works
Jones, G. A. L., Wiegand, M., Ray, S., Gould, D. W., Agbeko, R., Giallongo, E., Charles, W. N., Orzol, M., O’Neill, L., Lampro, L., et al. (2024) · Pediatric Critical Care Medicine · doi:10.1097/pcc.0000000000003583 · Cited by 12 · see citing works
He, Y., Liu, W., Lin, S., Li, Z., Qiu, H., Yim, S. H. L., Chuang, H., & Ho, K. (2023) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2023.163969 · Cited by 9 · see citing works
Girolamo, T. M., Butler, L. K., Canale, R. R., Aslin, R. Ν., & Eigsti, I. (2023) · Neuropsychology Review · doi:10.1007/s11065-023-09618-y · Cited by 9 · see citing works
A Clinician’s Guide to Understanding Bias in Critical Clinical Prediction Models
de Matos, J. C. R. G., Gallifant, J., Chowdhury, A., Economou-Zavlanos, N., Charpignon, M., Gichoya, J. W., Celi, L. A., Nazer, L. H., King, H., & Wong, A.-K. I. (2024) · Critical Care Clinics · doi:10.1016/j.ccc.2024.05.011 · Cited by 9 · see citing works
Xiong, N. (2024) · American Journal of Translational Research · doi:10.62347/lckg5157 · Cited by 9 · see citing works
Shining Light on Dark Skin: Pulse Oximetry Correction Models
de Matos, J. C. R. G., Struja, T., Gallifant, J., Charpignon, M., Cardoso, J. S., & Celi, L. A. (2023) · IEEE Portuguese Meeting on Bioengineering · doi:10.1109/enbeng58165.2023.10175316 · Cited by 7 · see citing works
Modulation of the allosteric and vasoregulatory arms of erythrocytic oxygen transport
Wise, T. J., Ott, M. E., Joseph, M. S., Welsby, I. J., Darrow, C. C., & McMahon, T. J. (2024) · Frontiers in Physiology · doi:10.3389/fphys.2024.1394650 · Cited by 8 · see citing works
Diversity and inclusion: A hidden additional benefit of Open Data
Charpignon, M., Celi, L. A., Cobanaj, M., Eber, R., Fiske, A., Gallifant, J., Li, C., Lingamallu, G., Petushkov, A., & Pierce, R. L. (2024) · PLOS Digital Health · doi:10.1371/journal.pdig.0000486 · Cited by 8 · see citing works
Overt and Occult Hypoxemia in Patients Hospitalized With COVID-19
Gadrey, S. M., Mohanty, P., Haughey, S. P., Jacobsen, B. A., Dubester, K. J., Webb, K. M., Kowalski, R. L., Dreicer, J. J., Andris, R. T., Clark, M., et al. (2023) · Critical Care Explorations · doi:10.1097/cce.0000000000000825 · Cited by 8 · see citing works
Discrimination by Design: Is It Time to Recalibrate Interpretation of Pulse Oximetry?*
Barreto, J. A., & Moynihan, K. M. (2023) · Pediatric Critical Care Medicine · doi:10.1097/pcc.0000000000003229 · Cited by 8 · see citing works
He, Y., Liu, W., Lin, S., Li, Z., Qiu, H., Yim, S. H. L., Chuang, H., & Ho, K. (2023) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2023.166531 · Cited by 7 · see citing works
Can we predict the future of respiratory failure prediction?
Pearce, A. K., Nemati, S., Goligher, E. C., Hough, C. L., Holder, A. L., Wardi, G., Yang, P., Boussina, A. E., Lyons, P. G., Sahetya, S. K., et al. (2025) · Critical Care · doi:10.1186/s13054-025-05484-7 · Cited by 7 · see citing works
Pulse Oximetry Discrepancies and Occult Hypoxemia in ICU Patients: Predictors and Clinical Outcomes
Saidy, S. O., Iqbal, A., & Baig, S. H. (2025) · Journal of Intensive Care Medicine · doi:10.1177/08850666251351594 · Cited by 10 · see citing works
- Authors
- Wong, A.-K. I., Charpignon, M., Kim, H., Josef, C., de Hond, A. A. H., Fojas, J. J., Tabaie, A., Liu, X., Mireles-Cabodevila, E., Carvalho, L., Kamaleswaran, R., Madushani, R. W. M. A., Adhikari, L., Holder, A. L., Steyerberg, E. W., Buchman, T. G., Lough, M. E., & Celi, L. A.
- Affiliations
- Emory University (US)
- Massachusetts Institute of Technology (US)
- Johns Hopkins University (US)
- Leiden University Medical Centre, Department of Biomedical Data Sciences, Leiden, the Netherlands
- Beth Israel Deaconess Medical Center (US)
- Beihang University (CN)
- School of Biological Science and Medical Engineering, Beihang University, Beijing, China
- Cleveland Clinic (US)
- Boston Medical Center (US)
- Philips (United States) (US)
- Leiden University Medical Center (NL)
- Stanford Health Care (US)
- Corresponding author
- Wong, An-Kwok Ian
- ORCID
- Venue
- JAMA Network Open
- Publisher
- American Medical Association (AMA)
- Published
- 2021-11-03
- Volume
- 4
- Issue
- 11
- Pages
- e2131674
- ISSN
- 2574-3805 (ISSN-L)
- PMC
- PMC9178439
- OpenAlex
- W3210241905
- Cited by
- 268
- References
- 25
- Citations by year
- 2026: 26 · 2025: 53 · 2024: 62 · 2023: 67 · 2022: 60
- FWCI
- 14.36
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- Locations
- JAMA Network Open (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Leiden Repository (Leiden University) (submittedVersion, cc-by)
- Data Archiving and Networked Services (DANS) (submittedVersion, cc-by)
- DSpace@MIT (Massachusetts Institute of Technology) (submittedVersion, cc-by-nc)
- Funders
- U.S. Department of Defense
- National Institutes of Health (5r01eb017205-07, R01-EB017205, EB017205, NIBIB R01 EB017205, UL1TR002378)
- Uniformed Services University of the Health Sciences (HT9404-13-1-0032, HU0001, USUHS HT9404-13-1-0032, HU0001-15-2-0001)
- Biomedical Advanced Research and Development Authority
- National Institute of General Medical Sciences (K23GM137182, T32GM095442, R01GM139967)
- National Institute of Biomedical Imaging and Bioengineering (NIBIB R01 EB017205, R01-EB017205, EB017205)
- National Center for Advancing Translational Sciences
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
- Health Sciences › Medicine › Epidemiology › Sepsis Diagnosis and Treatment
- Keywords
- pulse oximetry, arterial oxygen saturation, racial and ethnic disparities, arterial blood gases, intensive care unit patients, organ dysfunction, SOFA score, in-hospital mortality, length of hospital stay, lactate, creatinine, Black patients, Hispanic patients, health disparities, hypoxemia detection
- MeSH terms
- Oxygen Saturation, Aged, Hypoxia, Creatinine, Cross-Sectional Studies, Ethnicity, Female, Georgia, Humans, Male, Middle Aged, Multiple Organ Failure, Oximetry, Retrospective Studies, Racial Groups
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review