Automated Analysis of Retinal Images for Detection of Referable Diabetic Retinopathy
The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
IMPORTANCE: The diagnostic accuracy of computer detection programs has been reported to be comparable to that of specialists and expert readers, but no computer detection programs have been validated in an independent cohort using an internationally recognized diabetic retinopathy (DR) standard. OBJECTIVE: To determine the sensitivity and specificity of the Iowa Detection Program (IDP) to detect referable diabetic retinopathy (RDR). DESIGN AND SETTING: In primary care DR clinics in France, from January 1, 2005, through December 31, 2010, patients were photographed consecutively, and retinal color images were graded for retinopathy severity according to the International Clinical Diabetic Retinopathy scale and macular edema by 3 masked independent retinal specialists and regraded with adjudication until consensus. The IDP analyzed the same images at a predetermined and fixed set point. We defined RDR as more than mild nonproliferative retinopathy and/or macular edema. PARTICIPANTS: A total of 874 people with diabetes at risk for DR. MAIN OUTCOME MEASURES: Sensitivity and specificity of the IDP to detect RDR, area under the receiver operating characteristic curve, sensitivity and specificity of the retinal specialists' readings, and mean interobserver difference (κ). RESULTS: The RDR prevalence was 21.7% (95% CI, 19.0%-24.5%). The IDP sensitivity was 96.8% (95% CI, 94.4%-99.3%) and specificity was 59.4% (95% CI, 55.7%-63.0%), corresponding to 6 of 874 false-negative results (none met treatment criteria). The area under the receiver operating characteristic curve was 0.937 (95% CI, 0.916-0.959). Before adjudication and consensus, the sensitivity/specificity of the retinal specialists were 0.80/0.98, 0.71/1.00, and 0.91/0.95, and the mean intergrader κ was 0.822. CONCLUSIONS: The IDP has high sensitivity and specificity to detect RDR. Computer analysis of retinal photographs for DR and automated detection of RDR can be implemented safely into the DR screening pipeline, potentially improving access to screening and health care productivity and reducing visual loss through early treatment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1990) · Choice Reviews Online · doi:10.5860/choice.27-3338 · Cited by 35,305
(2007) · Developments in Ophthalmology · doi:10.1159/isbn.978-3-318-01439-6 · Cited by 5,583
Wilkinson, C. P., Ferris, F. L., Klein, R. E., Lee, P. P., Agardh, C. D., Davis, M., Dills, D., Kampik, A., Pararajasegaram, R., & Verdaguer, J. T. (2003) · Ophthalmology · doi:10.1016/s0161-6420(03)00475-5 · Cited by 3,743
Ranibizumab for Diabetic Macular Edema
Nguyen, Q. D., Brown, D. M., Marcus, D. M., Boyer, D. S., Patel, S., Feiner, L., Gibson, A., Sy, J., Rundle, A. C., Hopkins, J. J., et al. (2012) · Ophthalmology · doi:10.1016/j.ophtha.2011.12.039 · Cited by 1,621
Elman, M. J., Aiello, L. P., Beck, R. W., Bressler, N. M., Bressler, S. B., Edwards, A. R., Ferris, F. L., Friedman, S. M., Glassman, A. R., Miller, K. M., et al. (2010) · Ophthalmology · doi:10.1016/j.ophtha.2010.02.031 · Cited by 1,428
Mitchell, P., Bandello, F., Schmidt-Erfurth, U., Lang, G. E., Massin, P., Schlingemann, R. O., Sutter, F., Simader, C., Burian, G., Gerstner, O., et al. (2011) · Ophthalmology · doi:10.1016/j.ophtha.2011.01.031 · Cited by 1,326
Self-citationStatistics Notes: Diagnostic tests 3: receiver operating characteristic plots
Altman, D. G., & Bland, J. M. (1994) · BMJ · doi:10.1136/bmj.309.6948.188 · Cited by 599
Davis, M. D., Fisher, M. R., Gangnon, R. E., Barton, F. B., Aiello, L. M., Chew, E. Y., Ferris, F. L., & Knatterud, G. L. (1998) · PubMed · Cited by 576
Niemeijer, M., van Ginneken, B., Cree, M. J., Mizutani, A., Quellec, G., Sanchez, C. I., Zhang, B., Hornero, R., Lamard, M., Muramatsu, C., et al. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2033909 · Cited by 516
Self-citationAutomatic detection of red lesions in digital color fundus photographs
Niemeijer, M., van Ginneken, B., Staal, J., Suttorp-Schulten, M. S. A., & Abramoff, M. D. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.843738 · Cited by 504
Self-citation
Cited by
Gulshan, V., Peng, L., Coram, M., Stumpe, M. C., Wu, D., Narayanaswamy, A., Venugopalan, S., Widner, K., Madams, T., Cuadros, J., et al. (2016) · JAMA · doi:10.1001/jama.2016.17216 · Cited by 7,697
“A single network was trained to make multiple binary predictions, including whether the image was (1) moderate or worse diabetic retinopathy (ie, moderate, severe, or proliferative), (2) severe or worse diabetic retinopathy, (3) referable diabetic macular edema, or (4) fully gradable.”
BackgroundMethodAbràmoff, M. D., Lavin, P. T., Birch, M., Shah, N., & Folk, J. C. (2018) · npj Digital Medicine · doi:10.1038/s41746-018-0040-6 · Cited by 1,638
Self-citationArtificial intelligence and deep learning in ophthalmology
Ting, D. S. W., Pasquale, L. R., Peng, L., Campbell, J. P., Lee, A. Y., Raman, R., Tan, G. S. W., Schmetterer, L., Keane, P. A., & Wong, T. Y. (2019) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2018-313173 · Cited by 1,554
Artificial Intelligence and Deep Learning in Ophthalmology
Wang, Z., Keane, P. A., Chiang, M., Cheung, C. Y., Wong, T. Y., & Ting, D. S. W. (2022) · Artificial Intelligence in Medicine · doi:10.1007/978-3-030-64573-1_200 · Cited by 1,524
Abràmoff, M. D., Lou, Y., Erginay, A., Clarida, W., Amelon, R., Folk, J. C., & Niemeijer, M. (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.16-19964 · Cited by 1,101
Self-citationWong, T. Y., Cheung, C. M. G., Larsen, M., Sharma, S., & Simó, R. (2016) · Nature Reviews Disease Primers · doi:10.1038/nrdp.2016.12 · Cited by 1,094
A foundation model for generalizable disease detection from retinal images
Zhou, Y., Chia, M. A., Wagner, S. K., Ayhan, M. S., Williamson, D. J., Struyven, R. R., Liu, T., Xu, M., Lozano, M. G., Woodward-Court, P., et al. (2023) · Nature · doi:10.1038/s41586-023-06555-x · Cited by 1,014
Artificial intelligence in retina
Schmidt-Erfurth, U., Sadeghipour, A., Gerendas, B. S., Waldstein, S. M., & Bogunović, H. (2018) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2018.07.004 · Cited by 779
“In ophthalmology, automated screening based on retinal images has been a target for AI for some time (Abramoff et al., 2013; Abramoff et al., 2010).”
InfluentialDiabetic Retinopathy Preferred Practice Pattern®
Flaxel, C. J., Adelman, R. A., Bailey, S. T., Fawzi, A., Lim, J. I., Vemulakonda, G. A., & Ying, G.-S. (2020) · Ophthalmology · doi:10.1016/j.ophtha.2019.09.025 · Cited by 717
Screening for diabetic retinopathy: new perspectives and challenges
Vujosevic, S., Aldington, S. J., Silva, P., Hernández, C., Scanlon, P., Peto, T., & Simó, R. (2020) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(19)30411-5 · Cited by 671
A Cross-Modality Learning Approach for Vessel Segmentation in Retinal Images
Li, Q., Feng, B., Xie, L., Liang, P., Zhang, H., & Wang, T. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2457891 · Cited by 571
Krause, J., Gulshan, V., Rahimy, E., Karth, P., Widner, K., Corrado, G. S., Peng, L., & Webster, D. R. (2018) · Ophthalmology · doi:10.1016/j.ophtha.2018.01.034 · Cited by 564
Artificial intelligence powers digital medicine
Fogel, A. L., & Kvedar, J. C. (2018) · npj Digital Medicine · doi:10.1038/s41746-017-0012-2 · Cited by 456
Sayres, R., Taly, A., Rahimy, E., Blumer, K., Coz, D., Hammel, N., Krause, J., Narayanaswamy, A., Rastegar, Z., Wu, D., et al. (2019) · Ophthalmology · doi:10.1016/j.ophtha.2018.11.016 · Cited by 418
Applications of deep learning in fundus images: A review
Li, T., Bo, W., Hu, C., Kang, H., Liu, H., Wang, K., & Fu, H. (2021) · Medical Image Analysis · doi:10.1016/j.media.2021.101971 · Cited by 396
Artificial intelligence for diabetic retinopathy screening: a review
Grzybowski, A., Brona, P., Lim, G., Ruamviboonsuk, P., Tan, G. S. W., Abramoff, M., & Ting, D. S. W. (2020) · Eye · doi:10.1038/s41433-019-0566-0 · Cited by 376
Deep learning for diabetic retinopathy detection and classification based on fundus images: A review
Tsiknakis, N., Theodoropoulos, D., Manikis, G., Ktistakis, E., Boutsora, O., Berto, A., Scarpa, F., Scarpa, A., Fotiadis, D. I., & Marias, K. (2021) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2021.104599 · Cited by 328
Gulshan, V., Rajan, R. P., Widner, K., Wu, D., Wubbels, P., Rhodes, T., Whitehouse, K., Coram, M., Corrado, G., Ramasamy, K., et al. (2019) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2019.2004 · Cited by 303
van der Heijden, A. A., Abramoff, M. D., Verbraak, F., van Hecke, M. V., Liem, A., & Nijpels, G. (2018) · Acta Ophthalmologica · doi:10.1111/aos.13613 · Cited by 296
Automated Diabetic Retinopathy Image Assessment Software
Tufail, A., Rudisill, C., Egan, C., Kapetanakis, V. V., Salas-Vega, S., Owen, C. G., Lee, A., Louw, V., Anderson, J., Liew, G., et al. (2017) · Ophthalmology · doi:10.1016/j.ophtha.2016.11.014 · Cited by 283
Red Lesion Detection Using Dynamic Shape Features for Diabetic Retinopathy Screening
Seoud, L., Hurtut, T., Chelbi, J., Cheriet, F., & Langlois, J. M. P. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2509785 · Cited by 277
Son, J., Shin, J. Y., Kim, H. D., Jung, K.-H., Park, K. H., & Park, S. J. (2020) · Ophthalmology · doi:10.1016/j.ophtha.2019.05.029 · Cited by 235
A data-driven approach to referable diabetic retinopathy detection
Pires, R., Avila, S., Wainer, J., Valle, E., Abramoff, M. D., & Rocha, A. (2019) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2019.03.009 · Cited by 164
Kandel, I., & Castelli, M. (2020) · Applied Sciences · doi:10.3390/app10062021 · Cited by 160
“Messidor [48,49] is a publicly available dataset that consists of 1200 DR images.”
BackgroundA Survey on Deep Learning and Explainability for Automatic Report Generation from Medical Images
Messina, P., Pino, P., Parra, D., Soto, A., Besa, C., Uribe, S., Andía, M., Tejos, C., Prieto, C., & Capurro, D. (2022) · ACM Computing Surveys · doi:10.1145/3522747 · Cited by 142
Verbraak, F. D., Abramoff, M. D., Bausch, G. C. F., Klaver, C., Nijpels, G., Schlingemann, R. O., & van der Heijden, A. A. (2019) · Diabetes Care · doi:10.2337/dc18-0148 · Cited by 115
“As has been our standard in the past (13,19,28), we show all images of false”
BackgroundMethodResultHansen, M. B., Abràmoff, M. D., Folk, J. C., Mathenge, W., Bastawrous, A., & Peto, T. (2015) · PLOS ONE · doi:10.1371/journal.pone.0139148 · Cited by 93
“[9] The IDP performed well and it showed good results in differentiating participants into having no DED and having DED as a primary population screening tool and achieved this within the similar timeframe of one minute per eye as previously documented.”
BackgroundMethodSelf-citationLiu, J., Gibson, E., Ramchal, S., Shankar, V., Piggott, K., Sychev, Y., Li, A. S., Rao, P. K., Margolis, T. P., Fondahn, E., et al. (2021) · Ophthalmology Retina · doi:10.1016/j.oret.2020.06.016 · Cited by 88
Artificial Intelligence in Diabetic Eye Disease Screening
(2019) · Asia-Pacific Journal of Ophthalmology · doi:10.22608/apo.201976 · Cited by 82
Xie, Y., Gunasekeran, D. V., Balaskas, K., Keane, P. A., Sim, D. A., Bachmann, L. M., Macrae, C., & Ting, D. S. W. (2020) · Translational Vision Science & Technology · doi:10.1167/tvst.9.2.22 · Cited by 59
Artificial intelligence for early detection of diabetes mellitus complications via retinal imaging
Sobhi, N., Sadeghi-Bazargani, Y., Mirzaei, M., Abdollahi, M., Jafarizadeh, A., Pedrammehr, S., Alizadehsani, R., Tan, R.-S., Islam, S. M. S., & Acharya, U. R. (2025) · Journal of Diabetes & Metabolic Disorders · doi:10.1007/s40200-025-01596-7 · Cited by 39
Yang, Q., Bee, Y. M., Lim, C. C., Sabanayagam, C., Yim-Lui Cheung, C., Wong, T. Y., Ting, D. S. W., Lim, L.-L., Li, H., He, M., et al. (2025) · eClinicalMedicine · doi:10.1016/j.eclinm.2025.103089 · Cited by 38
Automated and computer-assisted detection, classification, and diagnosis of diabetic retinopathy
Abràmoff, M. D., Leng, T., Ting, D. S. W., Rhee, K., Horton, M. B., Brady, C. J., & Chiang, M. F. (2020) · Telemedicine and e-Health · doi:10.1089/tmj.2020.0008 · Cited by 30
Self-citationTsai, M.-J., Hsieh, Y.-T., Tsai, C.-H., Chen, M., Hsieh, A.-T., Tsai, C.-W., & Chen, M.-L. (2022) · Journal of Diabetes Research · doi:10.1155/2022/5779276 · Cited by 18
“In recent decades, various computer programs have been developed for automated analysis of color fundus images with acceptable and comparable accuracy to those of human graders [4, 5].”
Background(2021) · doi:10.1007/s43441-021-00355-z · Cited by 11
Metadata
- Authors
- Abràmoff, M. D., Folk, J. C., Han, D. P., Walker, J. D., Williams, D. F., Russell, S. R., Massin, P., Cochener, B., Gain, P., Tang, L., Lamard, M., Moga, D. C., Quellec, G., & Niemeijer, M.
- Venue
- JAMA Ophthalmology
- Publisher
- American Medical Association (AMA)
- Published
- 2013-03-01
- Volume
- 131
- Issue
- 3
- Pages
- 351
- ISSN
- 2168-6165 (ISSN-L)
- OpenAlex
- W2073244572
- Cited by
- 463
- References
- 31
- FWCI
- 9.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.