IMPORTANCE: The diagnostic accuracy of computer detection programs has been reported to be comparable to that of specialists and expert readers, but no computer detection programs have been validated in an independent cohort using an internationally recognized diabetic retinopathy (DR) standard. OBJECTIVE: To determine the sensitivity and specificity of the Iowa Detection Program (IDP) to detect referable diabetic retinopathy (RDR). DESIGN AND SETTING: In primary care DR clinics in France, from January 1, 2005, through December 31, 2010, patients were photographed consecutively, and retinal color images were graded for retinopathy severity according to the International Clinical Diabetic Retinopathy scale and macular edema by 3 masked independent retinal specialists and regraded with adjudication until consensus. The IDP analyzed the same images at a predetermined and fixed set point. We defined RDR as more than mild nonproliferative retinopathy and/or macular edema. PARTICIPANTS: A total of 874 people with diabetes at risk for DR. MAIN OUTCOME MEASURES: Sensitivity and specificity of the IDP to detect RDR, area under the receiver operating characteristic curve, sensitivity and specificity of the retinal specialists' readings, and mean interobserver difference (κ). RESULTS: The RDR prevalence was 21.7% (95% CI, 19.0%-24.5%). The IDP sensitivity was 96.8% (95% CI, 94.4%-99.3%) and specificity was 59.4% (95% CI, 55.7%-63.0%), corresponding to 6 of 874 false-negative results (none met treatment criteria). The area under the receiver operating characteristic curve was 0.937 (95% CI, 0.916-0.959). Before adjudication and consensus, the sensitivity/specificity of the retinal specialists were 0.80/0.98, 0.71/1.00, and 0.91/0.95, and the mean intergrader κ was 0.822. CONCLUSIONS: The IDP has high sensitivity and specificity to detect RDR. Computer analysis of retinal photographs for DR and automated detection of RDR can be implemented safely into the DR screening pipeline, potentially improving access to screening and health care productivity and reducing visual loss through early treatment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1990) · Choice Reviews Online · doi:10.5860/choice.27-3338 · Cited by 35,305
(2007) · Developments in Ophthalmology · doi:10.1159/isbn.978-3-318-01439-6 · Cited by 5,583
Wilkinson, C. P., Ferris, F. L., Klein, R. E., Lee, P. P., Agardh, C. D., Davis, M., Dills, D., Kampik, A., Pararajasegaram, R., & Verdaguer, J. T. (2003) · Ophthalmology · doi:10.1016/s0161-6420(03)00475-5 · Cited by 3,743
Ranibizumab for Diabetic Macular Edema
Nguyen, Q. D., Brown, D. M., Marcus, D. M., Boyer, D. S., Patel, S., Feiner, L., Gibson, A., Sy, J., Rundle, A. C., Hopkins, J. J., et al. (2012) · Ophthalmology · doi:10.1016/j.ophtha.2011.12.039 · Cited by 1,621
Elman, M. J., Aiello, L. P., Beck, R. W., Bressler, N. M., Bressler, S. B., Edwards, A. R., Ferris, F. L., Friedman, S. M., Glassman, A. R., Miller, K. M., et al. (2010) · Ophthalmology · doi:10.1016/j.ophtha.2010.02.031 · Cited by 1,428
Mitchell, P., Bandello, F., Schmidt-Erfurth, U., Lang, G. E., Massin, P., Schlingemann, R. O., Sutter, F., Simader, C., Burian, G., Gerstner, O., et al. (2011) · Ophthalmology · doi:10.1016/j.ophtha.2011.01.031 · Cited by 1,326
Self-citationStatistics Notes: Diagnostic tests 3: receiver operating characteristic plots
Altman, D. G., & Bland, J. M. (1994) · BMJ · doi:10.1136/bmj.309.6948.188 · Cited by 599
Davis, M. D., Fisher, M. R., Gangnon, R. E., Barton, F. B., Aiello, L. M., Chew, E. Y., Ferris, F. L., & Knatterud, G. L. (1998) · PubMed · Cited by 576
Niemeijer, M., van Ginneken, B., Cree, M. J., Mizutani, A., Quellec, G., Sanchez, C. I., Zhang, B., Hornero, R., Lamard, M., Muramatsu, C., et al. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2033909 · Cited by 516
Self-citationAutomatic detection of red lesions in digital color fundus photographs
Niemeijer, M., van Ginneken, B., Staal, J., Suttorp-Schulten, M. S. A., & Abramoff, M. D. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.843738 · Cited by 504
Self-citationNiemeijer, M., van Ginneken, B., Russell, S. R., Suttorp-Schulten, M. S. A., & Abra`moff, M. D. (2007) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.06-0996 · Cited by 400
Self-citationOptimal Wavelet Transform for the Detection of Microaneurysms in Retina Photographs
Quellec, G., Lamard, M., Josselin, P. M., Cazuguel, G., Cochener, B., & Roux, C. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.920619 · Cited by 343
Self-citationLin, D. Y., Blumenkranz, M. S., Brothers, R. J., & Grosvenor, D. M. (2002) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(02)01522-2 · Cited by 327
Automated Early Detection of Diabetic Retinopathy
Abràmoff, M. D., Reinhardt, J. M., Russell, S. R., Folk, J. C., Mahajan, V. B., Niemeijer, M., & Quellec, G. (2010) · Ophthalmology · doi:10.1016/j.ophtha.2010.03.046 · Cited by 287
Self-citationAbràmoff, M. D., Niemeijer, M., Suttorp-Schulten, M. S. A., Viergever, M. A., Russell, S. R., & van Ginneken, B. (2008) · Diabetes Care · doi:10.2337/dc07-1312 · Cited by 277
Self-citationSingle-field fundus photography for diabetic retinopathy screening
Williams, G. A., Scott, I. U., Haller, J. A., Maguire, A. M., Marcus, D., & McDonald, H. R. (2004) · Ophthalmology · doi:10.1016/j.ophtha.2004.02.004 · Cited by 266
Philip, S., Fleming, A. D., Goatman, K. A., Fonseca, S., Mcnamee, P., Scotland, G. S., Prescott, G. J., Sharp, P. F., & Olson, J. A. (2007) · British Journal of Ophthalmology · doi:10.1136/bjo.2007.119453 · Cited by 225
Splat Feature Classification With Application to Retinal Hemorrhage Detection in Fundus Images
Tang, L., Niemeijer, M., Reinhardt, J. M., Garvin, M. K., & Abramoff, M. D. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2227119 · Cited by 185
Self-citationCost Effectiveness of Current Approaches to the Control of Retinopathy in Type I Diabetics
Javitt, J. C., Canner, J. K., & Sommer, A. (1989) · Ophthalmology · doi:10.1016/s0161-6420(89)32923-x · Cited by 177
Ahmed, J., Ward, T. P., Bursell, S.-E., Aiello, L. M., Cavallerano, J. D., & Vigersky, R. A. (2006) · Diabetes Care · doi:10.2337/dc06-0295 · Cited by 152
Niemeijer, M., Abràmoff, M. D., & van Ginneken, B. (2006) · Medical Image Analysis · doi:10.1016/j.media.2006.09.006 · Cited by 146
Self-citationScreening for Presence or Absence of Diabetic Retinopathy: A Meta-analysis
Bragge, P. (2011) · Archives of Ophthalmology · doi:10.1001/archophthalmol.2010.319 · Cited by 134
Web-Based Screening for Diabetic Retinopathy in a Primary Care Population: The EyeCheck Project
Abramoff, M. D., & Suttorp-Schulten, M. S. A. (2005) · Telemedicine and e-Health · doi:10.1089/tmj.2005.11.668 · Cited by 125
Information Fusion for Diabetic Retinopathy CAD in Digital Color Fundus Photographs
Niemeijer, M., Abràmoff, M. D., & van Ginneken, B. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.2012029 · Cited by 125
Self-citationScotland, G. S., McNamee, P., Philip, S., Fleming, A. D., Goatman, K. A., Prescott, G. J., Fonseca, S., Sharp, P. F., & Olson, J. A. (2007) · British Journal of Ophthalmology · doi:10.1136/bjo.2007.120972 · Cited by 107
Scotland, G. S., McNamee, P., Fleming, A. D., Goatman, K. A., Philip, S., Prescott, G. J., Sharp, P. F., Williams, G. J., Wykes, W., Leese, G. P., et al. (2010) · British Journal of Ophthalmology · doi:10.1136/bjo.2008.151126 · Cited by 89
The role of haemorrhage and exudate detection in automated grading of diabetic retinopathy
Fleming, A., Goatman, K. A., Philip, S., Williams, G. J., Prescott, G. J., Scotland, G., McNamee, P., Leese, G., Wykes, W. N., Sharp, P. F., et al. (2009) · British Journal of Ophthalmology · doi:10.1136/bjo.2008.149807 · Cited by 85
Cavallerano, J. D., Aiello, L. P., CAVALLERANO, A. A., Katalinic, P., Hock, K. M., Kirby, R. K., & Aiello, L. M. (2005) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2005.03.075 · Cited by 69
Lawrence, M. G. (2004) · PubMed Central · Cited by 62
Hazin, R., Colyer, M. H., Lum, F., & Barazi, M. K. (2011) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2011.06.022 · Cited by 59
Benefits of stereopsis when identifying clinically significant macular edema via teleophthalmology
Rudnisky, C. J., TENNANT, M. T. S., de Leon, A. R., Hinz, B. J., & Greve, M. D. J. (2006) · Canadian Journal of Ophthalmology · doi:10.3129/i06-066 · Cited by 32
Cited by
Gulshan, V., Peng, L., Coram, M., Stumpe, M. C., Wu, D., Narayanaswamy, A., Venugopalan, S., Widner, K., Madams, T., Cuadros, J., et al. (2016) · JAMA · doi:10.1001/jama.2016.17216 · Cited by 7,697
“A single network was trained to make multiple binary predictions, including whether the image was (1) moderate or worse diabetic retinopathy (ie, moderate, severe, or proliferative), (2) severe or worse diabetic retinopathy, (3) referable diabetic macular edema, or (4) fully gradable.”
BackgroundMethodAbràmoff, M. D., Lavin, P. T., Birch, M., Shah, N., & Folk, J. C. (2018) · npj Digital Medicine · doi:10.1038/s41746-018-0040-6 · Cited by 1,638
Self-citationArtificial intelligence and deep learning in ophthalmology
Ting, D. S. W., Pasquale, L. R., Peng, L., Campbell, J. P., Lee, A. Y., Raman, R., Tan, G. S. W., Schmetterer, L., Keane, P. A., & Wong, T. Y. (2019) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2018-313173 · Cited by 1,554
Artificial Intelligence and Deep Learning in Ophthalmology
Wang, Z., Keane, P. A., Chiang, M., Cheung, C. Y., Wong, T. Y., & Ting, D. S. W. (2022) · Artificial Intelligence in Medicine · doi:10.1007/978-3-030-64573-1_200 · Cited by 1,524
Abràmoff, M. D., Lou, Y., Erginay, A., Clarida, W., Amelon, R., Folk, J. C., & Niemeijer, M. (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.16-19964 · Cited by 1,101
Self-citation
Metadata
- Authors
- Abràmoff, M. D., Folk, J. C., Han, D. P., Walker, J. D., Williams, D. F., Russell, S. R., Massin, P., Cochener, B., Gain, P., Tang, L., Lamard, M., Moga, D. C., Quellec, G., & Niemeijer, M.
- Venue
- JAMA Ophthalmology
- Publisher
- American Medical Association (AMA)
- Published
- 2013-03-01
- Volume
- 131
- Issue
- 3
- Pages
- 351
- ISSN
- 2168-6165 (ISSN-L)
- OpenAlex
- W2073244572
- Cited by
- 463
- References
- 31
- FWCI
- 9.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.