Interventions to improve use of continuous positive airway pressure for obstructive sleep apnoea
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Continuous Positive Airways Pressure (CPAP) is currently considered to be the cornerstone of therapy for sleep apnoea (OSA). However compliance with this treatment is frequently poor, which may lead to ongoing symptoms of sleep disruption, daytime sleepiness and poor waking cognitive function. Mechanical and psychological/educational interventions have been proposed to try to increase the hours of use of CPAP therapy. OBJECTIVES: To determine the efficacy of interventions designed to increase compliance with CPAP. SEARCH STRATEGY: We searched the Cochrane Airways Group Sleep Apnoea Specialised Register (January 2004). SELECTION CRITERIA: Randomised controlled trials (RCTs) assessing interventions to improve compliance with CPAP usage were considered for inclusion in the review. DATA COLLECTION AND ANALYSIS: Two reviewers assessed articles for inclusion in the review and extracted data. Attempts were made to obtain additional unpublished data from the trialists. MAIN RESULTS: 24 studies met the inclusion criteria with 1007 participants. Each of the mechanical interventions was compared with fixed CPAP alone. Auto-CPAP (13 studies): A small, significant difference was observed in compliance but this effect disappeared when we took account of the variation between the studies. There may be a subgroup of patients who respond better than others. Most participants preferred auto-CPAP to fixed CPAP where this was measured. Bi-level PAP (3 studies): No significant differences were observed in compliance. One small study found no difference in preference. Patient titrated CPAP (1 study): No significant difference was observed in compliance. Humidification(1 study): This small study found no significant difference in compliance. Educational/psychological interventions (6 studies): One small study demonstrated superior compliance in patients treated with cognitive behavioural therapy + CPAP versus CPAP alone but only after 12 weeks. In one, larger study intensive support including home visits increased hours of use. No other study demonstrated significant effects in favour of active treatment. REVIEWERS' CONCLUSIONS: The effect of Auto-CPAP in increasing hours of use in unselected patients starting this treatment remains unclear. Different pooled analyses gave conflicting results and it may be that carefully selected participants may respond more favourably than others. The evidence in support of Bi-PAP, self-titration and humidification is lacking and studies are required in these areas. There is some evidence that psychological/educational interventions improve CPAP usage. This requires confirmation in larger studies of longer duration, with rigorous follow-up. The cost-benefit ratio of such interventions requires assessment. Future studies need to consider the effects of treatment in participants who are poorly compliant. The studies assembled were characterised by high machine usage in the control groups, and low withdrawal rates making it less likely that any benefit could be demonstrated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Occurrence of Sleep-Disordered Breathing among Middle-Aged Adults
Young, T., Palta, M., Dempsey, J., Skatrud, J., Weber, S., & Badr, S. (1993) · New England Journal of Medicine · doi:10.1056/nejm199304293281704 · Cited by 10,183
Objective Measurement of Patterns of Nasal CPAP Use by Patients with Obstructive Sleep Apnea
Kribbs, N. B., Pack, A. I., Kline, L. R., Smith, P. L., Schwartz, A. R., Schubert, N. M., Redline, S., Henry, J. N., Getsy, J. E., & Dinges, D. F. (1993) · American Review of Respiratory Disease · doi:10.1164/ajrccm/147.4.887 · Cited by 1,339
Jenkinson, C., Davies, R. J., Mullins, R., & Stradling, J. R. (1999) · The Lancet · doi:10.1016/s0140-6736(98)10532-9 · Cited by 826
Side Effects of Nasal Continuous Positive Airway Pressure in Sleep Apnea Syndrome
Pépin, J. L., Leger, P., Veale, D., Langevin, B., Robert, D., & Lévy, P. (1995) · Chest · doi:10.1378/chest.107.2.375 · Cited by 422
HOY, C. J., VENNELLE, M., KINGSHOTT, R. N., ENGLEMAN, H. M., & DOUGLAS, N. J. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.159.4.9808008 · Cited by 379
Massie, C. A., Hart, R. W., Peralez, K., & Richards, G. N. (1999) · Chest · doi:10.1378/chest.116.2.403 · Cited by 308
Compliance With Nasal CPAP Can Be Improved by Simple Interventions
Chervin, R. D., Theut, S., Bassetti, C., & Aldrich, M. S. (1997) · Sleep · doi:10.1093/sleep/20.4.284 · Cited by 242
Continuous Versus Bilevel Positive Airway Pressure for Obstructive Sleep Apnea
Reeves-Hoché, M. K., Hudgel, D. W., Meck, R., Witteman, R., Ross, A., & Zwillich, C. W. (1995) · American journal of respiratory and critical care medicine · doi:10.1164/ajrccm.151.2.7842204 · Cited by 192
Zozula, R., & Rosen, R. (2001) · Current Opinion in Pulmonary Medicine · doi:10.1097/00063198-200111000-00005 · Cited by 189
Comparison between Automatic and Fixed Positive Airway Pressure Therapy in the Home
Massie, C. A., McArdle, N., Hart, R. W., Schmidt-Nowara, W. W., Lankford, A., Hudgel, D. W., Gordon, N., & Douglas, N. J. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200201-022oc · Cited by 177
Comparison of nose and face mask CPAP therapy for sleep apnoea
Mortimore, I. L., Whittle, A. T., & Douglas, N. J. (1998) · Thorax · doi:10.1136/thx.53.4.290 · Cited by 149
Autoadjusting CPAP Therapy Based on Impedance Efficacy, Compliance and Acceptance
RANDERATH, W. J., SCHRAEDER, O., GALETKE, W., FELDMEYER, F., & RÜHLE, K.-H. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.3.2006168 · Cited by 143
Hui, D. S. C., Chan, J. K. W., Choy, D. K. L., Ko, F. W. S., Li, T. S. T., Leung, R. C. C., & Lai, C. K. W. (2000) · Chest · doi:10.1378/chest.117.5.1410 · Cited by 141
Improving Compliance with Nasal CPAP and Vigilance in Older Adults with OSAHS
Aloia, M. S., Dio, L. D., Ilniczky, N., Perlis, M. L., Greenblatt, D. W., & Giles, D. E. (2001) · Sleep And Breathing · doi:10.1055/s-2001-12789 · Cited by 117
Hudgel, D. W., & Fung, C. (2000) · Sleep · doi:10.1093/sleep/23.5.1g · Cited by 112
Constant vs Automatic Continuous Positive Airway Pressure Therapy
d'Ortho, M.-P., Grillier-Lanoir, V., Levy, P., Goldenberg, F., Corriger, E., Harf, A., & Lofaso, F. (2000) · Chest · doi:10.1378/chest.118.4.1010 · Cited by 103
Two months auto-adjusting versus conventional nCPAP for obstructive sleep apnoea syndrome
Teschler, H., Wessendorf, T. E., Farhat, A. A., Konietzko, N., & Berthon-Jones, M. (2000) · European Respiratory Journal · doi:10.1034/j.1399-3003.2000.01503.x · Cited by 97
Senn, O., Brack, T., Matthews, F., Russi, E. W., & Bloch, K. E. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200304-542oc · Cited by 73
Efficacy and Cost of Home-Initiated Auto-nCPAP versus Conventional nCPAP
Planès, C., D'Ortho, M.-P., Foucher, A., Berkani, M., Leroux, K., Essalhi, M., Delclaux, C., Quera-Salva, M.-A., & Lofaso, F. (2003) · Sleep · doi:10.1093/sleep/26.2.156 · Cited by 68
Khanna, R. (2003) · Sleep Medicine · doi:10.1016/s1389-9457(03)00063-7 · Cited by 46
Cited by
Meschia, J. F., Bushnell, C., Boden-Albala, B., Braun, L. T., Bravata, D. M., Chaturvedi, S., Creager, M. A., Eckel, R. H., Elkind, M. S. V., Fornage, M., et al. (2014) · Stroke · doi:10.1161/str.0000000000000046 · Cited by 2,650
Adherence to Continuous Positive Airway Pressure Therapy: The Challenge to Effective Treatment
Weaver, T. E., & Grunstein, R. R. (2008) · Proceedings of the American Thoracic Society · doi:10.1513/pats.200708-119mg · Cited by 1,680
Oral appliances for obstructive sleep apnoea
Lim, J., Lasserson, T. J., Fleetham, J., & Wright, J. J. (2006) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd004435.pub3 · Cited by 418
Self-citationWozniak, D. R., Lasserson, T. J., & Smith, I. (2014) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd007736.pub2 · Cited by 379
Self-citationRichards, D., Bartlett, D. J., Wong, K., Malouff, J., & Grunstein, R. R. (2007) · Sleep · doi:10.1093/sleep/30.5.635 · Cited by 257
Metadata
- Authors
- Smith, I., Lasserson, T. J., & Haniffa, M.
- Venue
- Cochrane Database of Systematic Reviews
- Publisher
- John Wiley & Sons, Ltd
- Published
- 2004-10-18
- Issue
- 4
- Pages
- CD003531-CD003531
- ISSN
- 1361-6137 (ISSN-L)
- OpenAlex
- W1785382413
- Cited by
- 152
- References
- 20
- Type
- reference entry
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.