Continuous cardiotocography (CTG) as a form of electronic fetal monitoring (EFM) for fetal assessment during labour
Open accessThe DOI matches its Crossref record; 54 of the 54 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Cardiotocography (CTG) records changes in the fetal heart rate and their temporal relationship to uterine contractions. The aim is to identify babies who may be short of oxygen (hypoxic) to guide additional assessments of fetal wellbeing, or determine if the baby needs to be delivered by caesarean section or instrumental vaginal birth. This is an update of a review previously published in 2013, 2006 and 2001. OBJECTIVES: To evaluate the effectiveness and safety of continuous cardiotocography when used as a method to monitor fetal wellbeing during labour. SEARCH METHODS: We searched the Cochrane Pregnancy and Childbirth Group Trials Register (30 November 2016) and reference lists of retrieved studies. SELECTION CRITERIA: Randomised and quasi-randomised controlled trials involving a comparison of continuous cardiotocography (with and without fetal blood sampling) with no fetal monitoring, intermittent auscultation intermittent cardiotocography. DATA COLLECTION AND ANALYSIS: Two review authors independently assessed study eligibility, quality and extracted data from included studies. Data were checked for accuracy. MAIN RESULTS: We included 13 trials involving over 37,000 women. No new studies were included in this update.One trial (4044 women) compared continuous CTG with intermittent CTG, all other trials compared continuous CTG with intermittent auscultation. No data were found comparing no fetal monitoring with continuous CTG. Overall, methodological quality was mixed. All included studies were at high risk of performance bias, unclear or high risk of detection bias, and unclear risk of reporting bias. Only two trials were assessed at high methodological quality.Compared with intermittent auscultation, continuous cardiotocography showed no significant improvement in overall perinatal death rate (risk ratio (RR) 0.86, 95% confidence interval (CI) 0.59 to 1.23, N = 33,513, 11 trials, low quality evidence), but was associated with halving neonatal seizure rates (RR 0.50, 95% CI 0.31 to 0.80, N = 32,386, 9 trials, moderate quality evidence). There was no difference in cerebral palsy rates (RR 1.75, 95% CI 0.84 to 3.63, N = 13,252, 2 trials, low quality evidence). There was an increase in caesarean sections associated with continuous CTG (RR 1.63, 95% CI 1.29 to 2.07, N = 18,861, 11 trials, low quality evidence). Women were also more likely to have instrumental vaginal births (RR 1.15, 95% CI 1.01 to 1.33, N = 18,615, 10 trials, low quality evidence). There was no difference in the incidence of cord blood acidosis (RR 0.92, 95% CI 0.27 to 3.11, N = 2494, 2 trials, very low quality evidence) or use of any pharmacological analgesia (RR 0.98, 95% CI 0.88 to 1.09, N = 1677, 3 trials, low quality evidence).Compared with intermittent CTG, continuous CTG made no difference to caesarean section rates (RR 1.29, 95% CI 0.84 to 1.97, N = 4044, 1 trial) or instrumental births (RR 1.16, 95% CI 0.92 to 1.46, N = 4044, 1 trial). Less cord blood acidosis was observed in women who had intermittent CTG, however, this result could have been due to chance (RR 1.43, 95% CI 0.95 to 2.14, N = 4044, 1 trial).Data for low risk, high risk, preterm pregnancy and high-quality trials subgroups were consistent with overall results. Access to fetal blood sampling did not appear to influence differences in neonatal seizures or other outcomes.Evidence was assessed using GRADE. Most outcomes were graded as low quality evidence (rates of perinatal death, cerebral palsy, caesarean section, instrumental vaginal births, and any pharmacological analgesia), and downgraded for limitations in design, inconsistency and imprecision of results. The remaining outcomes were downgraded to moderate quality (neonatal seizures) and very low quality (cord blood acidosis) due to similar concerns over limitations in design, inconsistency and imprecision. AUTHORS' CONCLUSIONS: CTG during labour is associated with reduced rates of neonatal seizures, but no clear differences in cerebral palsy, infant mortality or other standard measures of neonatal wellbeing. However, continuous CTG was associated with an increase in caesarean sections and instrumental vaginal births. The challenge is how best to convey these results to women to enable them to make an informed decision without compromising the normality of labour.The question remains as to whether future randomised trials should measure efficacy (the intrinsic value of continuous CTG in trying to prevent adverse neonatal outcomes under optimal clinical conditions) or effectiveness (the effect of this technique in routine clinical practice).Along with the need for further investigations into long-term effects of operative births for women and babies, much remains to be learned about the causation and possible links between antenatal or intrapartum events, neonatal seizures and long-term neurodevelopmental outcomes, whilst considering changes in clinical practice over the intervening years (one-to-one-suppo
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
Continuous electronic heart rate monitoring for fetal assessment during labor
Thacker, S., Stroup, D., & Chang, M. (2001) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd000063 · Cited by 222
RetractedPharmacological interventions for somatoform disorders in adults
Kleinstäuber, M., Witthöft, M., Steffanowski, A., van Marwijk, H., Hiller, W., & Lambert, M. J. (2014) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd010628.pub2 · Cited by 11,335
Cochrane Handbook for Systematic Reviews of Interventions Version 5.0.1. The Cochrane Collaboration
Higgins, J. P. T., Green, S. R., & Higgins, J. P. T. (2008) · Cited by 7,226
Bayley Scales of Infant Development
(2007) · Encyclopedia of Measurement and Statistics · doi:10.4135/9781412952644.n48 · Cited by 4,240
4 million neonatal deaths: When? Where? Why?
Lawn, J. E., Cousens, S., & Zupan, J. (2005) · The Lancet · doi:10.1016/s0140-6736(05)71048-5 · Cited by 3,670
(2010) · Handbook of Disease Burdens and Quality of Life Measures · doi:10.1007/978-0-387-78665-0_6514 · Cited by 1,385
Effective Care in Pregnancy and Childbirth
Paintin, D. B. (1990) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1990.tb02464.x · Cited by 1,330
Published by John Wiley & Sons Ltd
Modarresi, O. A. F., & Shakibaie, M. M. M. R. (2015) · Cited by 1,111
Subgroup analysis in randomised controlled trials: importance, indications, and interpretation
Rothwell, P. M. (2005) · The Lancet · doi:10.1016/s0140-6736(05)17709-5 · Cited by 942
Guide to Effective Care in Pregnancy and Childbirth
Enkin, M., Keirse, M., Neilson, J., Crowther, C., Duley, L., Hodnett, E., & Hofmeyr, J. (2000) · Oxford University Press eBooks · doi:10.1093/med/9780192631732.001.0001 · Cited by 909
(2009) · Obstetrics & Gynecology · doi:10.1097/aog.0b013e3181aef106 · Cited by 895
The Dublin randomized controlled trial of intrapartum fetal heart rate monitoring
MacDonald, D., Grant, A., Sheridan-Pereira, M., Boylan, P., & Chalmers, I. (1985) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(85)90619-2 · Cited by 631
Uncertain Value of Electronic Fetal Monitoring in Predicting Cerebral Palsy
Nelson, K. B., Dambrosia, J. M., Ting, T. Y., & Grether, J. K. (1996) · New England Journal of Medicine · doi:10.1056/nejm199603073341001 · Cited by 532
A controlled trial of the differential effects of intrapartum fetal monitoring
Haverkamp, A. D., Orleans, M., Langendoerfer, S., McFee, J., Murphy, J., & Thompson, H. E. (1979) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(16)33082-4 · Cited by 392
Leduc, D., Biringer, A., Lee, L., Dy, J., Corbett, T., Leduc, D., Biringer, A., Duperron, L., Dy, J., Lange, I., et al. (2013) · Journal of Obstetrics and Gynaecology Canada · doi:10.1016/s1701-2163(15)30842-2 · Cited by 347
The evaluation of continuous fetal heart rate monitoring in high-risk pregnancy
Haverkamp, A. D., Thompson, H. E., McFee, J. G., & Cetrulo, C. (1976) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(76)90565-2 · Cited by 324
Garite, T. J., Dildy, G. A., McNamara, H., Nageotte, M. P., Boehm, F. H., Dellinger, E. H., Knuppel, R. A., Porreco, R. P., Miller, H. S., Sunderji, S., et al. (2000) · American Journal of Obstetrics and Gynecology · doi:10.1067/mob.2000.110632 · Cited by 314
(1984) · Elsevier eBooks · doi:10.1016/c2013-0-03951-5 · Cited by 285
Fetal electrocardiogram (ECG) for fetal monitoring during labour
Neilson, J. P. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd000116.pub5 · Cited by 279
RETIRED: Fetal Health Surveillance: Antepartum and Intrapartum Consensus Guideline
Liston, R., Sawchuck, D., Young, D., Brassard, N., Campbell, K., Davies, G., Ehman, W., Farine, D., Farquharson, D., Hamilton, E., et al. (2007) · Journal of Obstetrics and Gynaecology Canada · doi:10.1016/s1701-2163(16)32615-9 · Cited by 278
Leveno, K. J., Cunningham, F. G., Nelson, S., Roark, M., Williams, M. L., Guzick, D., Dowling, S., Rosenfeld, C. R., & Buckley, A. (1986) · New England Journal of Medicine · doi:10.1056/nejm198609043151004 · Cited by 226
CEREBRAL PALSY AMONG CHILDREN BORN DURING THE DUBLIN RANDOMISED TRIAL OF INTRAPARTUM MONITORING
Grant, A., Joy, M.-T., O'Brien, N., Hennessy, E., & Macdonald, D. (1989) · The Lancet · doi:10.1016/s0140-6736(89)91848-5 · Cited by 225
Devane, D., Lalor, J. G., Daly, S., McGuire, W., Cuthbert, A., & Smith, V. (2017) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd005122.pub5 · Cited by 213
Self-citationFetal pulse oximetry for fetal assessment in labour
East, C. E., Begg, L., Colditz, P. B., & Lau, R. (2014) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd004075.pub4 · Cited by 211
Controlled trial of fetal intensive care
Renou, P., Chang, A., Anderson, I., & Wood, C. (1976) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(76)90641-4 · Cited by 202
Efficacy and safety of intrapartum electronic fetal monitoring: an update
THACKER, S., STROUP, D., & PETERSON, H. (1995) · Obstetrics & Gynecology · doi:10.1016/s0029-7844(95)80027-1 · Cited by 185
Vintzileos, A. M., Antsaklis, A. J., Varvarigos, I., Papas, C., Sofatzis, I., & Montgomery, J. T. (1993) · PubMed · Cited by 159
Lie, K. K., Groholt, E.-K., & Eskild, A. (2010) · BMJ · doi:10.1136/bmj.c4990 · Cited by 144
Chen, H.-Y., Chauhan, S. P., Ananth, C. V., Vintzileos, A. M., & Abuhamad, A. (2011) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2011.04.024 · Cited by 141
Intrapartum fetal stimulation tests: a meta-analysis
Skupski, D. (2002) · Obstetrics & Gynecology · doi:10.1016/s0029-7844(01)01645-3 · Cited by 141
A Critique of the Literature on Women’s Request for Cesarean Section
Gamble, J., Creedy, D. K., McCourt, C., Weaver, J., & Beake, S. (2007) · Birth · doi:10.1111/j.1523-536x.2007.00193.x · Cited by 115
Fetal heart rate patterns: monitoring, interpretation, and management
(1995) · International Journal of Gynecology & Obstetrics · doi:10.1016/0020-7292(95)80014-4 · Cited by 113
Teenage Outcome After Being Born at Term With Moderate Neonatal Encephalopathy
Lindström, K., Lagerroos, P., Gillberg, C., & Fernell, E. (2006) · Pediatric Neurology · doi:10.1016/j.pediatrneurol.2006.05.003 · Cited by 103
Randomised controlled trial of intrapartum fetal heart rate monitoring
Mahomed, K., Nyoni, R., Mulambo, T., Kasule, J., & Jacobus, E. (1994) · BMJ · doi:10.1136/bmj.308.6927.497 · Cited by 96
Vintzileos, A. M., NOCHIMSON, D. J., Antsaklis, A. J., Varvarigos, I., Guzman, E. R., & Knuppel, R. A. (1995) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(95)91320-3 · Cited by 84
Antenatal antecedents of moderate and severe cerebral palsy
Palmer, L. J., Blairt, E., Petterson, B., & Burton, P. R. (1995) · Paediatric and Perinatal Epidemiology · doi:10.1111/j.1365-3016.1995.tb00132.x · Cited by 77
Luttkus, A. K., Norén, H., Stupin, J. H., Blad, S., Arulkumaran, S., Erkkola, R. U., Hagberg, H., Lenstrup, C., Visser, G. H. A., Tamazian, O., et al. (2004) · Journal of Perinatal Medicine · doi:10.1515/jpm.2004.121 · Cited by 68
Professionals’ views of fetal monitoring during labour: a systematic review and thematic analysis
Smith, V. A., Begley, C., Clarke, M. J., & Devane, D. (2012) · BMC Pregnancy and Childbirth · doi:10.1186/1471-2393-12-166 · Cited by 66
Self-citationIntermittent versus continuous electronic monitoring in labour: a randomised study
Herbst, A., & Ingemarsson, I. (1994) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1994.tb13181.x · Cited by 66
Garcia, J., Corry, M., MacDonald, D., et al. (1985) · Birth · doi:10.1111/j.1523-536x.1985.tb00943.x · Cited by 64
East, C. E., Smyth, R. M., Leader, L. R., Henshall, N. E., Colditz, P. B., Lau, R., & Tan, K. H. (2013) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd004664.pub3 · Cited by 52
GIBB, D. M. F., & Arulkumaran, S. (1992) · Cited by 48
Fetal electrocardiogram (ECG) for fetal monitoring during labour
Neilson, J., & Mistry, R. T. (2003) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd000116 · Cited by 47
Keegan, K. A., Waffarn, F., & Quilligan, E. J. (1985) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(85)90334-5 · Cited by 46
A Randomized Trial of Electronic Fetal Monitoring in Preterm Labor: Mothers'Views
Killien, M., & Shy, K. K. (1989) · Birth · doi:10.1111/j.1523-536x.1989.tb00847.x · Cited by 31
Devane, D., Lalor, J., Daly, S., & McGuire, W. L. (2005) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd005122 · Cited by 31
Self-citationRosser, J. (1998) · PubMed · Cited by 30
RETIRED: Fetal Health Surveillance in Labour
(2002) · Journal of Obstetrics and Gynaecology Canada · doi:10.1016/s1701-2163(16)30227-4 · Cited by 30
Continuous electronic heart rate monitoring for fetal assessment during labor
Thacker, S. B., Stroup, D. F., & Chang, M. (2006) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd000063.pub2 · Cited by 29
East, C. E., Smyth, R. M., Leader, L. R., Henshall, N. E., Colditz, P. B., & Tan, K. H. (2005) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd004664.pub2 · Cited by 24
Intrapartum electronic fetal monitoring vs. intermittent auscultation in postcesarean pregnancies
Madaan, M., & Trivedi, S. S. (2006) · International Journal of Gynecology & Obstetrics · doi:10.1016/j.ijgo.2006.03.026 · Cited by 23
Mahomed, K., Nyoni, R., Trust Mlambo, Jacobus, E., & Kasule, J. (1992) · PubMed · Cited by 16
Fetal pulse oximetry for fetal assessment in labour
East, C. E., Chan, F.-Y., & Colditz, P. B. (2004) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd004075.pub2 · Cited by 16
Cited by
Andrews, J., Guyatt, G., Oxman, A. D., Alderson, P., Dahm, P., Falck-Ytter, Y., Nasser, M., Meerpohl, J., Post, P. N., Kunz, R., et al. (2013) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2012.03.013 · Cited by 1,416
Renfrew, M. J., McFadden, A., Bastos, M. H., Campbell, J., Channon, A. A., Cheung, N. F., Silva, D. R. A. D., Downe, S., Kennedy, H. P., Malata, A., et al. (2014) · The Lancet · doi:10.1016/s0140-6736(14)60789-3 · Cited by 1,297
Miller, S., Abalos, E., Chamillard, M., Ciapponi, A., Colaci, D., Comandé, D., Diaz, V., Geller, S., Hanson, C., Langer, A., et al. (2016) · The Lancet · doi:10.1016/s0140-6736(16)31472-6 · Cited by 1,181
FIGO consensus guidelines on intrapartum fetal monitoring: Cardiotocography
Ayres‐de‐Campos, D., Spong, C. Y., Chandraharan, E., & Panel, F. I. F. M. E. C. (2015) · International Journal of Gynecology & Obstetrics · doi:10.1016/j.ijgo.2015.06.020 · Cited by 911
Analysis of Dimensionality Reduction Techniques on Big Data
Reddy, G. T., Reddy, M. P. K., Lakshmanna, K., Kaluri, R., Rajput, D. S., Srivastava, G., & Baker, T. (2020) · IEEE Access · doi:10.1109/access.2020.2980942 · Cited by 877
Metadata
- Authors
- Alfirevic, Z., Devane, D., & Gyte, G. M.
- Venue
- Cochrane Database of Systematic Reviews
- Publisher
- John Wiley & Sons, Ltd
- Published
- 2006-07-19
- Volume
- 2
- Issue
- 3
- Pages
- CD006066-CD006066
- ISSN
- 1361-6137 (ISSN-L)
- OpenAlex
- W2146446882
- Cited by
- 1,035
- References
- 54
- Type
- reference entry
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.