Silicon Chip Interfaced with a Geometrically Defined Net of Snail Neurons
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
We have successfully interfaced living neuronal networks with a defined geometry of synaptic connections to a semiconductor chip, enabling a non‐invasive supervision of network activity at a single‐cell level. Two networks of two and four neurons are presented and the signaling pathways are discussed. The outgrowth of neurons from the pond snail Lymnaea stagnalis and the formation of synapses are controlled by topographical structures processed from a polyester resist. Action potentials are evoked in individual neurons by capacitive stimulators integrated in the chip. They propagate along guided neurites, pass through electrical synapses, and trigger postsynaptic excitations that are recorded by field‐effect transistors. The networks represent proof‐of‐principle experiments for the development of complex hybrid neuroelectronic devices for applications in brain research, pharmacology, and information technology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Neuron-Silicon Junction: A Retzius Cell of the Leech on an Insulated-Gate Field-Effect Transistor
Fromherz, P., Offenhäusser, A., Vetter, T., & Weis, J. (1991) · Science · doi:10.1126/science.1925540 · Cited by 563
Self-citationZeck, G., & Fromherz, P. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.181348698 · Cited by 290
Self-citationJimbo, Y., Robinson, H. P. C., & Kawana, A. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.238465 · Cited by 192
Silicon-neuron junction: capacitive stimulation of an individual neuron on a silicon chip.
Fromherz, P., & Stett, A. (1995) · Physical Review Letters · doi:10.1103/physrevlett.75.1670 · Cited by 167
Self-citationMicroelectronic and nanoelectronic interfacing techniques for biological systems
Connolly, P., Moores, G. R., Monaghan, W., Shen, J., Britland, S., & Clark, P. (1992) · Sensors and Actuators B: Chemical · doi:10.1016/0925-4005(92)80041-u · Cited by 30
Cited by
Patolsky, F., Timko, B. P., Yu, G., Fang, Y., Greytak, A. B., Zheng, G., & Lieber, C. M. (2006) · Science · doi:10.1126/science.1128640 · Cited by 832
A Review of Organic and Inorganic Biomaterials for Neural Interfaces
Fattahi, P., Yang, G., Kim, G., & Abidian, M. R. (2014) · Advanced Materials · doi:10.1002/adma.201304496 · Cited by 580
Nanomaterials for Neural Interfaces
Kotov, N. A., Winter, J. O., Clements, I. P., Jan, E., Timko, B. P., Campidelli, S., Pathak, S., Mazzatenta, A., Lieber, C. M., Prato, M., et al. (2009) · Advanced Materials · doi:10.1002/adma.200801984 · Cited by 504
Richardson-Burns, S. M., Hendricks, J. L., Foster, B., Povlich, L. K., Kim, D.-H., & Martin, D. C. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.11.026 · Cited by 503
Applications of conducting polymers and their issues in biomedical engineering
Ravichandran, R., Sundarrajan, S., Venugopal, J. R., Mukherjee, S., & Ramakrishna, S. (2010) · Journal of The Royal Society Interface · doi:10.1098/rsif.2010.0120.focus · Cited by 429
Metadata
- Authors
- Merz, M., & Fromherz, P.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2005-04-26
- Volume
- 15
- Issue
- 5
- Pages
- 739-744
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2139314043
- Cited by
- 69
- References
- 5
- FWCI
- 2.38
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.