The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Micropatterned Polypyrrole: A Combination of Electrical and Topographical Characteristics for the Stimulation of Cells
Open accessAbstract
Electrically conducting polymers such as polypyrrole (PPy) are important biomaterials in neural engineering applications, including neural probes, nerve conduits, and scaffolds for tissue and nerve regeneration. Surface modification of these polymers can introduce other valuable characteristics for neural interfacing in addition to electrical conductivity, such as topographical features and chemical bioactivity. Here, the patterning of PPy to create topographical cues for cells is reported. In particular, 1 and 2 μm wide PPy microchannels are fabricated using electron‐beam (e‐beam) lithography and electropolymerization. A systematic analysis of parameters controlling PPy micropatterning is performed, and finds that microchannel depth, roughness, and morphology are highly dependent on the e‐beam writing current, polymerization current, PPy/dopant concentrations, and the polymerization time. Embryonic hippocampal neurons cultured on patterned PPy polarize (i.e., defined an axon) faster on this modified material, with a twofold increase in the number of cells with axons compared to cells cultured on unmodified PPy. These topographical features also have an effect on axon orientation but do not have a significant effect on overall axon length. This is the first investigation that studies controlled PPy patterning with small dimensions (i.e., less than 5 μm) for biological applications, which demonstrates the relevance of expanding microelectronic materials and techniques to the biomedical field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The establishment of polarity by hippocampal neurons in culture.
Dotti, C., Sullivan, C., & Banker, G. (1988) · The Journal of Neuroscience · doi:10.1523/jneurosci.08-04-01454.1988 · Cited by 1,862
The sequential activity of the GTPases Rap1B and Cdc42 determines neuronal polarity.
Schwamborn, J. C., & Püschel, A. W. (2004) · Nature Neuroscience · doi:10.1038/nn1295 · Cited by 385
Cited by
Conductive polymers: Towards a smart biomaterial for tissue engineering
Balint, R., Cassidy, N. J., & Cartmell, S. H. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.02.015 · Cited by 1,777
Yang, J. C., Mun, J., Kwon, S. Y., Park, S., Bao, Z., & Park, S. (2019) · Advanced Materials · doi:10.1002/adma.201904765 · Cited by 1,641
Conducting polymers in biomedical engineering
Guimard, N. K., Gomez, N., & Schmidt, C. E. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.05.012 · Cited by 1,599
Self-citationPolypyrrole-coated electrospun PLGA nanofibers for neural tissue applications
Lee, J. Y., Bashur, C. A., Goldstein, A. S., & Schmidt, C. E. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.04.042 · Cited by 735
Self-citationGhasemi-Mobarakeh, L., Prabhakaran, M. P., Morshed, M., Nasr-Esfahani, M. H., Baharvand, H., Kiani, S., Al-Deyab, S. S., & Ramakrishna, S. (2011) · Journal of Tissue Engineering and Regenerative Medicine · doi:10.1002/term.383 · Cited by 698
A Review of Organic and Inorganic Biomaterials for Neural Interfaces
Fattahi, P., Yang, G., Kim, G., & Abidian, M. R. (2014) · Advanced Materials · doi:10.1002/adma.201304496 · Cited by 580
Liu, Z., Wan, X., Wang, Z. L., & Li, L. (2021) · Advanced Materials · doi:10.1002/adma.202007429 · Cited by 478
Biomimetic Scaffolds for Tissue Engineering
Kim, T. G., Shin, H., & Lim, D. W. (2012) · Advanced Functional Materials · doi:10.1002/adfm.201103083 · Cited by 459
Applications of conducting polymers and their issues in biomedical engineering
Ravichandran, R., Sundarrajan, S., Venugopal, J. R., Mukherjee, S., & Ramakrishna, S. (2010) · Journal of The Royal Society Interface · doi:10.1098/rsif.2010.0120.focus · Cited by 429
Abidian, M. R., Corey, J. M., Kipke, D. R., & Martin, D. C. (2010) · Small · doi:10.1002/smll.200901868 · Cited by 405
Conducting Polymers for Neural Prosthetic and Neural Interface Applications
Green, R., & Abidian, M. R. (2015) · Advanced Materials · doi:10.1002/adma.201501810 · Cited by 392
Electroactive polymers for tissue regeneration: Developments and perspectives
Ning, C., Zhou, Z., Tan, G., Zhu, Y., & Mao, C. (2018) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2018.01.001 · Cited by 346
3D printing of electrically conductive hydrogels for tissue engineering and biosensors – A review
Distler, T., & Boccaccini, A. R. (2020) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.08.044 · Cited by 326
Luo, S.-C., Mohamed Ali, E., Tansil, N. C., Yu, H.-H., Gao, S., Kantchev, E. A. B., & Ying, J. Y. (2008) · Langmuir · doi:10.1021/la800333g · Cited by 323
Review paper: Progress in the Field of Conducting Polymers for Tissue Engineering Applications
Bendrea, A.-D., Cianga, L., & Cianga, I. (2011) · Journal of Biomaterials Applications · doi:10.1177/0885328211402704 · Cited by 322
Conductive Core–Sheath Nanofibers and Their Potential Application in Neural Tissue Engineering
Xie, J., MacEwan, M. R., Willerth, S. M., Li, X., Moran, D. W., Sakiyama‐Elbert, S. E., & Xia, Y. (2009) · Advanced Functional Materials · doi:10.1002/adfm.200801904 · Cited by 321
A hybrid bioorganic interface for neuronal photoactivation
Ghezzi, D., Antognazza, M. R., Dal Maschio, M., Lanzarini, E., Benfenati, F., & Lanzani, G. (2011) · Nature Communications · doi:10.1038/ncomms1164 · Cited by 305
Conductive PPY/PDLLA conduit for peripheral nerve regeneration
Xu, H., Holzwarth, J. M., Yan, Y., Xu, P., Zheng, H., Yin, Y., Li, S., & Ma, P. X. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2013.10.002 · Cited by 296
Biomimetic electrochemistry from conducting polymers. A review
Otero, T. F., Martinez, J. G., & Arias-Pardilla, J. (2012) · Electrochimica Acta · doi:10.1016/j.electacta.2012.03.097 · Cited by 292
Aligned PLLA nanofibrous scaffolds coated with graphene oxide for promoting neural cell growth
Zhang, K., Zheng, H., Liang, S., & Gao, C. (2016) · Acta Biomaterialia · doi:10.1016/j.actbio.2016.04.008 · Cited by 261
Stretchable Polymeric Multielectrode Array for Conformal Neural Interfacing
Guo, L., Ma, M., Zhang, N., Langer, R., & Anderson, D. G. (2014) · Advanced Materials · doi:10.1002/adma.201304140 · Cited by 128
Sun, B., Zhou, Z., Li, D., Wu, T., Zheng, H., Liu, J., Wang, G., Yu, Y., & Mo, X. (2019) · Materials Science and Engineering: C · doi:10.1016/j.msec.2018.09.021 · Cited by 100
Metadata
- Authors
- Gomez, N., Lee, J. Y., Nickels, J. D., & Schmidt, C. E.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2007-05-09
- Volume
- 17
- Issue
- 10
- Pages
- 1645-1653
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W1979817557
- Cited by
- 212
- References
- 2
- FWCI
- 11.18
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.