Stretchable and Transparent Biointerface Using Cell‐Sheet–Graphene Hybrid for Electrophysiology and Therapy of Skeletal Muscle
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
Implantable electronic devices for recording electrophysiological signals and for stimulating muscles and nerves have been widely used throughout clinical medicine. Mechanical mismatch between conventional rigid biomedical devices and soft curvilinear tissues, however, has frequently resulted in a low signal to noise ratio and/or mechanical fatigue and scarring. Multifunctionality ranging from various sensing modalities to therapeutic functions is another important goal for implantable biomedical devices. Here, a stretchable and transparent medical device using a cell‐sheet–graphene hybrid is reported, which can be implanted to form a high quality biotic/abiotic interface. The hybrid is composed of a sheet of C2C12 myoblasts on buckled, mesh‐patterned graphene electrodes. The graphene electrodes monitor and actuate the C2C12 myoblasts in vitro, serving as a smart cell culture substrate that controls their aligned proliferation and differentiation. This stretchable and transparent cell‐sheet–graphene hybrid can be transplanted onto the target muscle tissue, to record electromyographical signals, and stimulate implanted sites electrically and/or optically in vivo. Additional cellular therapeutic effect of the cell‐sheet–graphene hybrid is obtained by integrated myobalst cell sheets. Any immune responses within implanted muscle tissues are not observed. This multifunctional device provides many new opportunities in the emerging field of soft bioelectronics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kim, D.-H., Lu, N., Ma, R., Kim, Y.-S., Kim, R.-H., Wang, S., Wu, J., Won, S. M., Tao, H., Islam, A., et al. (2011) · Science · doi:10.1126/science.1206157 · Cited by 4,836
Self-citationReconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250
Stretchable silicon nanoribbon electronics for skin prosthesis
Kim, J., Lee, M., Shim, H. J., Ghaffari, R., Cho, H. R., Son, D., Jung, Y. H., Soh, M., Choi, C., Jung, S., et al. (2014) · Nature Communications · doi:10.1038/ncomms6747 · Cited by 1,435
Self-citationFlexible organic transistors and circuits with extreme bending stability
Sekitani, T., Zschieschang, U., Klauk, H., & Someya, T. (2010) · Nature Materials · doi:10.1038/nmat2896 · Cited by 1,253
Injectable, Cellular-Scale Optoelectronics with Applications for Wireless Optogenetics
Kim, T.-I., McCall, J. G., Jung, Y. H., Huang, X., Siuda, E. R., Li, Y., Song, J., Song, Y. M., Pao, H. A., Kim, R.-H., et al. (2013) · Science · doi:10.1126/science.1232437 · Cited by 1,174
Self-citationElectronic dura mater for long-term multimodal neural interfaces
Minev, I. R., Musienko, P., Hirsch, A., Barraud, Q., Wenger, N., Moraud, E. M., Gandar, J., Capogrosso, M., Milekovic, T., Asboth, L., et al. (2015) · Science · doi:10.1126/science.1260318 · Cited by 1,082
A Human Disease Model of Drug Toxicity–Induced Pulmonary Edema in a Lung-on-a-Chip Microdevice
Huh, D., Leslie, D. C., Matthews, B. D., Fraser, J. P., Jurek, S., Hamilton, G. A., Thorneloe, K. S., McAlexander, M. A., & Ingber, D. E. (2012) · Science Translational Medicine · doi:10.1126/scitranslmed.3004249 · Cited by 993
NeuroGrid: recording action potentials from the surface of the brain
Khodagholy, D., Gelinas, J. N., Thesen, T., Doyle, W., Devinsky, O., Malliaras, G. G., & Buzsáki, G. (2015) · Nature Neuroscience · doi:10.1038/nn.3905 · Cited by 938
A skin-inspired organic digital mechanoreceptor
Tee, B. C.-K., Chortos, A., Berndt, A., Nguyen, A. K., Tom, A., McGuire, A., Lin, Z. C., Tien, K., Bae, W.-G., Wang, H., et al. (2015) · Science · doi:10.1126/science.aaa9306 · Cited by 882
Rejuvenation of the muscle stem cell population restores strength to injured aged muscles
Cosgrove, B. D., Gilbert, P. M., Porpiglia, E., Mourkioti, F., Lee, S. P., Corbel, S. Y., Llewellyn, M. E., Delp, S. L., & Blau, H. M. (2014) · Nature Medicine · doi:10.1038/nm.3464 · Cited by 677
Self-citation
Cited by
Nature-Inspired Structural Materials for Flexible Electronic Devices
Liu, Y., He, K., Chen, G., Leow, W. R., & Chen, X. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00291 · Cited by 798
Enzyme‐Based Glucose Sensor: From Invasive to Wearable Device
Lee, H., Hong, Y. J., Baik, S., Hyeon, T., & Kim, D. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201701150 · Cited by 778
Self-citationNanomaterial-Enabled Wearable Sensors for Healthcare
Yao, S., Swetha, P., & Zhu, Y. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700889 · Cited by 576
Koo, J. H., Kim, D. C., Shim, H. J., Kim, T., & Kim, D. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201801834 · Cited by 562
Self-citationHong, Y. J., Jeong, H., Cho, K. W., Lu, N., & Kim, D. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201808247 · Cited by 559
Self-citationCheng, C., Li, S., Thomas, A., Kotov, N. A., & Haag, R. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00520 · Cited by 527
Material‐Based Approaches for the Fabrication of Stretchable Electronics
Kim, D. C., Shim, H. J., Lee, W., Koo, J. H., & Kim, D. (2020) · Advanced Materials · doi:10.1002/adma.201902743 · Cited by 438
Self-citationFlexible quantum dot light-emitting diodes for next-generation displays
Choi, M. K., Yang, J., Hyeon, T., & Kim, D.-H. (2018) · npj Flexible Electronics · doi:10.1038/s41528-018-0023-3 · Cited by 399
Self-citation2D Materials in Flexible Electronics: Recent Advances and Future Prospectives
Katiyar, A. K., Hoang, A. T., Xu, D., Hong, J., Kim, B. J., Ji, S., & Ahn, J.-H. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00302 · Cited by 363
Transfer printing techniques for flexible and stretchable inorganic electronics
Linghu, C., Zhang, S., Wang, C., & Song, J. (2018) · npj Flexible Electronics · doi:10.1038/s41528-018-0037-x · Cited by 357
Mehrali, M., Thakur, A., Pennisi, C. P., Talebian, S., Arpanaei, A., Nikkhah, M., & Dolatshahi‐Pirouz, A. (2017) · Advanced Materials · doi:10.1002/adma.201603612 · Cited by 345
Graphene-Based Sensors for Human Health Monitoring
Huang, H., Su, S., Wu, N., Wan, H., Wan, S., Bi, H., & Sun, L. (2019) · Frontiers in Chemistry · doi:10.3389/fchem.2019.00399 · Cited by 330
Mayer, M., & Baeumner, A. J. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00719 · Cited by 300
Ultratransparent and stretchable graphene electrodes
Liu, N., Chortos, A., Lei, T., Jin, L., Kim, T. R., Bae, W.-G., Zhu, C., Wang, S., Pfattner, R., Chen, X., et al. (2017) · Science Advances · doi:10.1126/sciadv.1700159 · Cited by 286
Ultrasoft electronics to monitor dynamically pulsing cardiomyocytes
Lee, S., Sasaki, D., Kim, D., Mori, M., Yokota, T., Lee, H., Park, S., Fukuda, K., Sekino, M., Matsuura, K., et al. (2019) · Nature Nanotechnology · doi:10.1038/s41565-018-0331-8 · Cited by 269
Self-citationHerbert, R., Kim, J.-H., Kim, Y., Lee, H., & Yeo, W.-H. (2018) · Materials · doi:10.3390/ma11020187 · Cited by 220
Conformable hybrid systems for implantable bioelectronic interfaces
Fallegger, F., Schiavone, G., & Lacour, S. P. (2020) · Advanced Materials · doi:10.1002/adma.201903904 · Cited by 113
Metadata
- Authors
- Kim, S. J., Cho, K. W., Cho, H. R., Wang, L., Park, S. Y., Lee, S. E., Hyeon, T., Lu, N., Choi, S. H., & Kim, D.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2016-03-15
- Volume
- 26
- Issue
- 19
- Pages
- 3207-3217
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2301847980
- Cited by
- 152
- References
- 18
- FWCI
- 9.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.