The DOI matches its Crossref record; 297 of the 298 references it cites were found in a registry or an index.
Wearable and Implantable Devices for Cardiovascular Healthcare: from Monitoring to Therapy Based on Flexible and Stretchable Electronics
Abstract
Cardiovascular disease is the leading cause of death and has dramatically increased in recent years. Continuous cardiac monitoring is particularly important for early diagnosis and prevention, and flexible and stretchable electronic devices have emerged as effective tools for this purpose. Their thin, soft, and deformable features allow intimate and long‐term integration with biotissues, which enables continuous, high‐fidelity, and sometimes large‐area cardiac monitoring on the skin and/or heart surface. In addition to monitoring, intimate contact is also crucial for high‐precision therapies. Combined with tissue engineering, soft bioelectronics have also demonstrated the capability to repair damaged cardiac tissues. This review highlights the recent advances in wearable and implantable devices based on flexible and stretchable electronics for cardiovascular monitoring and therapy. First, wearable/implantable soft bioelectronics for cardiovascular monitoring (e.g., the electrocardiogram, blood pressure, and oxygen saturation level) are reviewed. Then, advances in cardiovascular therapy based on soft bioelectronics (e.g., mesh pacing, ablation, robotic sleeves, and electronic stents) are discussed. Finally, device‐assisted tissue engineering therapy (e.g., functional electronic scaffolds and in vitro cardiac platforms) is discussed.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Rapid advances in flexible and stretchable soft bio-electronics, provide a viable solution for wearable, comfortable, and continuous health monitoring.”
From A Chest‐Conformable, Wireless Electro‐Mechanical E‐Tattoo for Measuring Multiple Cardiac Time Intervals (2023) · cites this paper as [6]
Citations
Cites
Flexible triboelectric generator
Fan, F.-R., Tian, Z.-Q., & Lin Wang, Z. (2012) · Nano Energy · doi:10.1016/j.nanoen.2012.01.004 · Cited by 6,705
Hydrogels for tissue engineering: scaffold design variables and applications
Drury, J. L., & Mooney, D. J. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00340-5 · Cited by 5,136
Kim, D.-H., Lu, N., Ma, R., Kim, Y.-S., Kim, R.-H., Wang, S., Wu, J., Won, S. M., Tao, H., Islam, A., et al. (2011) · Science · doi:10.1126/science.1206157 · Cited by 4,836
Self-citationAdult Cardiac Stem Cells Are Multipotent and Support Myocardial Regeneration
Beltrami, A. P., Barlucchi, L., Torella, D., Baker, M., Limana, F., Chimenti, S., Kasahara, H., Rota, M., Musso, E., Urbanek, K., et al. (2003) · Cell · doi:10.1016/s0092-8674(03)00687-1 · Cited by 3,528
Kocher, A. A., Schuster, M., Szabolcs, M., Takuma, S., Burkhoff, D., Wang, J., Homma, S., Edwards, N. M., & Itescu, S. (2001) · Nature Medicine · doi:10.1038/86498 · Cited by 2,524
Approaches to catheter ablation for persistent atrial fibrillation
Verma, A., Jiang, C.-Y., Betts, T. R., Chen, J., Deisenhofer, I., Mantovan, R., Macle, L., Morillo, C. A., Haverkamp, W., Weerasooriya, R., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1408288 · Cited by 2,339
Strauer, B. E., Brehm, M. U., Zeus, T., Köstering, M., Hernandez, A., Sorg, R. V., Kögler, G., & Wernet, P. (2002) · Circulation · doi:10.1161/01.cir.0000034046.87607.1c · Cited by 2,065
Cryoballoon or Radiofrequency Ablation for Paroxysmal Atrial Fibrillation
Kuck, K.-H., Brugada, J., Fürnkranz, A., Metzner, A., Ouyang, F., Chun, K. R. J., Elvan, A., Arentz, T., Bestehorn, K., Pocock, S. J., et al. (2016) · New England Journal of Medicine · doi:10.1056/nejmoa1602014 · Cited by 1,950
Flexible Nanogenerators for Energy Harvesting and Self‐Powered Electronics
Fan, F. R., Tang, W., & Wang, Z. L. (2016) · Advanced Materials · doi:10.1002/adma.201504299 · Cited by 1,933
Rapid casting of patterned vascular networks for perfusable engineered three-dimensional tissues
Miller, J. S., Stevens, K. R., Yang, M. T., Baker, B. M., Nguyen, D.-H. T., Cohen, D. M., Toro, E., Chen, A. A., Galie, P. A., Yu, X., et al. (2012) · Nature Materials · doi:10.1038/nmat3357 · Cited by 1,917
Flagged first, then by citations
1 of the 298 references couldn’t be matched to a known paper.
Research works printed but not linked: 15
- Jeong H., 2017, 39th Annu. Int. Conf. of IEEE Eng. Med. Biol. Soc.,
- Lonini L., 2017, Proc. 2017 ACM Int. Joint Conf. Pervasive and Ubiquitous Comput. and Proc. 2017 ACM Int. Symp. Wearable Comput.
- Webster J. G., 2009, Medical Instrumentation: Application and Design, 4th Edition
- Cong P., 2009, IEEE Int. Solid‐State Circuits Conf.
- Penaz J., 1973, Digest of the 10th Int. Conf. Med. Biol. Eng.
- Zhang H. L., 2014, Sci. World J., 2014, 404913
- Alraies M. C., 2014, J. Thorac. Dis., 6, 1120
- Reis Filho J. R., 2015, Arq. Bras. Cardiol., 104, 502
- Jhun C.‐S., 2010, Computational Cardiovascular Mechanics: Modelling and Applications in Heart Failure
- Roche E. T., 2015, Proc. ASME 2015 Int. Des. Eng. Tech. Conf. Comput. Inf. Eng. Conf.
- Horvath M. A., 2015, Proc. ASME 2015 Int. Des. Eng. Tech. Conf. Comput. Inf. Eng. Conf.
- Waksman R., 2016, Cirs.: Cardiovasc. Intervention, 9, e004150
- Jia H., 2018, Adv. Polym. Technol., 00, 1
- Park J., 2017, 19th Int. Conf. Solid‐State Sensors, Actuators and Microsystems
- 10.1038/nmat3404 · DOI · Paper page
Cited by
Sorted by citations
Items 501–558 of 558
Nanotechnology for Cerebral Aneurysm Treatment
Aditya, T., Posada, V. M., & Allain, J. P. (2024) · Springer eBooks · doi:10.1007/978-3-030-80662-0_18 · Cited by 1
He, Y. L., & Li, Z. (2025) · AIP Advances · doi:10.1063/5.0238879 · Cited by 1
Sun, M., Wang, T., Zhu, X., Ge, F., Liang, S., Xu, B., Ni, K., & Zhang, Y. (2024) · Research Square · doi:10.21203/rs.3.rs-3908908/v1 · Cited by 1
Functionalized Nanomaterials for Flexible and Stretchable Bioelectronics
Assad, H., Kumar, P., Berdimurodov, E. T., Kumar, A., & Kumar, A. (2025) · Wiley eBooks · doi:10.1002/9781394214105.ch9 · Cited by 1
Nishimura, K., Araki, T., Takemoto, A., AKIYAMA, M., Kiriyama, K., Kasai, Y., Kurihira, N., Uemura, T., & Sekitani, T. (2021) · International Conference on Electronics Packaging (ICEP) · doi:10.23919/icep51988.2021.9451962
“Biosensors must be flexibile to realize noninvasive application to biological tissues, such as the skin and organs [1,2].”
BackgroundMEAM parameterization for cyclic and tensile deformations of Gold-Silver core-shell systemsPreprint
Alvi, S. M. A. A., Faiyad, A., Munshi, M. A. M., Motalab, M., Islam, M., & Saha, S. (2021) · arXiv (Cornell University) · doi:10.48550/arxiv.2109.08196
“EcohesiveAB = [EABbulk − ( N 2 EAatom + N 2 EBatom)] /N (1)”
Nagamine, K., Sekine, T., & Tokito, S. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-822548-6.00077-7
Song, Y., Gao, W. F., & Zhang, H. (2021) · Wiley eBooks · doi:10.1002/9783527833474.ch1
On-Chip Photovoltaic Cell for Energy-Autonomous Implantable DevicesPreprint
Zhao, J., Ghannam, R., Law, M. K., Jiang, Y., Walton, F., Imran, M. A., & Heidari, H. (2021) · SSRN Electronic Journal · doi:10.2139/ssrn.3988619
Intelligent Systems and Smart Devices for the Continuous Monitoring of Cardiac Hemodynamics
Dual, S. A., & Daners, M. S. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-816861-5.00007-1
Research progress of flexible hydrogel sensor
Zhang, D. (2023) · Advances in Computer Signals and Systems · doi:10.23977/acss.2023.070102
Sung, M. (2023) · International Journal of Students Research in Technology & Management · doi:10.18510/ijsrtm.2023.1113
Kim, Y.-W., Kim, K., & Kang, S. (2023) · Journal of Flexible and Printed Electronics · doi:10.56767/jfpe.2023.2.1.25
“또한, 유연전자소자는 조직과의 적합한 접촉과 낮은 기계적 응력과 같은 장점으로 인 해 생체 신호 감지, 약물 전달, 신경 자극 등과 같은 다양한 용도의 체내 삽입형 의료소자 분야에서 사용되 기에도 적합하다[4-7].”
Smart Wearables for Cardiac Monitoring
(2023) · Advances in medical technologies and clinical practice book series · doi:10.4018/978-1-6684-4875-5.ch008
Implanted Stretch Sensor for Blood Pressure Measurement: Pig Study and Benchtop Evaluation
Ukwela, J., Barron, L. L., Dunning, J. L., Baskin, J. Z., & Majerus, S. J. A. (2023) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/sensors56945.2023.10325294
“…pacemakers and defibrillators would also benefit from detecting blood pressure [7] Implantable blood pressure/flow sensors have been demonstrated using many modalities [8] including intra-arterial MEMS sensors [9] and sensors which pierce the vessel wall for intravascular access [10].”
MethodAll-printing fabrication for stretchable devices Based on R2R processes
Nagatake, K., Kawakami, H., Ni, S., Nakamura, F., Takano, T., Ohara, I., Matsuda, R., Horii, T., Fujie, T., & Ota, H. (2024) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/mems58180.2024.10439586
Alagöz, C. (2024) · medRxiv · doi:10.1101/2024.02.29.24303483
“In the realm of continuous cardiovascular assessment, wearable and implanted devices, alongside ambulatory monitoring technologies, have become indispensable components (Hong et al., 2019; Sana et al., 2020; Bayoumy et al., 2021).”
BackgroundHuang, S., Chen, J., Huang, X., He, M., Liu, Z., Yao, C., Xu, X., Liu, J., Jiang, L., Chen, H.-J., et al. (2024) · Chinese Science Bulletin (Chinese Version) · doi:10.1360/tb-2024-0643 · Cited by 1
A Biocompatible Strain Sensor Based on Ni-GaIn and SA-Doped PAAM for Implantable Bioelectronics
Tu, M., Liang, J., Guo, H., Zhao, T., & Yu, H. (2025) · Lecture notes in computer science · doi:10.1007/978-981-96-0795-2_31
Soft Materials for Wearable Electronics
Roy, A., & Adhikari, A. (2024) · Advanced structured materials · doi:10.1007/978-981-97-9468-3_11
Biosensors for cardiovascular applications
Askari, V. R., Saberifar, M., Fadaei, M. S., Fadaei, M. R., Rahimi, V. B., Hasnain, M. S., & Nayak, A. K. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-21592-6.00011-2
Upendra Sharma, U. S., Majumder, R., & Lenka, D. N. (2023) · Seminars in Medical Writing and Education · doi:10.56294/mw2023134
Design on Surfaces with Wetting‐Controlled Effects
Zheng, Y. (2025) · Wiley eBooks · doi:10.1002/9783527844326.ch3
Phogat, P., Sharma, S., Rai, S., & Thakur, J. (2025) · Engineering materials · doi:10.1007/978-981-96-6767-3_2
Emerging technologies for the integration of flexible electronics into Heart-on-a-Chip platforms
Choo, J. (2025) · Journal of High School Science · doi:10.64336/001c.142193
Jin, Q., Xug, Y., Li, M., & Li, L. (2025) · SID Symposium Digest of Technical Papers · doi:10.1002/sdtp.18796
Jeerapan, I. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-23582-5.00007-0
Buried-Gate Flexible CNT FET with HZO Dielectric on Mica Substrate
Li, H., Shen, J., Zhuo, Z., Zhang, F., Liu, X., & Liao, Q. (2025) · Nanomaterials · doi:10.3390/nano15161218
Soft Sensors for Disease Diagnosis
Hu, H., Su, Y., & Nan, K. (2025) · Wiley eBooks · doi:10.1002/9783527845507.ch3
A Novel Ultra-Low-Voltage Pseudo-Dynamic Voltage Comparator Based On OAI Standard-Cells
Manno, A., Scotti, G., & Palumbo, G. (2025) · Conference on Ph.D. Research in Microelectronics and Electronics · doi:10.1109/prime66228.2025.11203554
Introduction to medical devices: research trends, evaluations, and applications
Sen, O., Nag, S., Gupta, P., Jana, S., Nandi, G., & Manna, S. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-32828-2.00001-6
Thermoresponsive E‐Skin with Reversible Sweat Transport
Xu, Y., Dong, X., Zhou, S., Xu, C., Yang, G., & Li, Z. (2025) · Advanced Functional Materials · doi:10.1002/adfm.202525282
A magnetic field regulated flexible memristor for implantable biomedical application
Qin, J., Sun, B. T., Mao, S., Lin, W., Yang, Y., Jing, Y.-R., Zhou, G., & Zhao, Y. (2025) · Ceramics International · doi:10.1016/j.ceramint.2025.12.189
PVDF-TrFE/Fe3O4-based flexible and stretchable tactile (FST) sensors for multi-scenario applications
Huangfu, Y., Fu, J., Tian, H., & Hao, H. (2025) · Journal of Electrostatics · doi:10.1016/j.elstat.2025.104204
Carneiro, M. R., Silva, J., & Tavakoli, M. (2026) · Discover Sensors · doi:10.1007/s44397-026-00054-0
Nanostructured Materials‐Based Implantable and Biomedical Sensors
Ozbey, S., Alhardan, R., Cinti, S., & Kurbanoğlu, S. (2026) · Wiley eBooks · doi:10.1002/9781394309870.ch17
Lavanya, J., Praveena, R., & Gomathi, N. (2026) · ChemNanoMat · doi:10.1002/cnma.202500806
Reddy, R. A., Shilpa, N., Vanniappan, M., & Balle, S. (2026) · Lecture notes in networks and systems · doi:10.1007/978-3-032-22917-5_10
Wang, Y., Cui, W., Huang, H., Yang, Y., He, X., & Liu, M. (2026) · Rare Metals · doi:10.1002/rar2.70320
A multi-functional passive fixation lead for diagnosis and treatment of cardiac diseases
Deng, X., Hu, Y. R., Yao, P., Yu, C., Yang, J., Luo, R., Cheng, S., Huang, H., Peng, C., Jia, L., et al. (2026) · Chemical Engineering Journal · doi:10.1016/j.cej.2026.177655
Upconversion Nanoparticles-Enhanced Hydrogels for Both Strain/Stress Sensors and VOCs Adsorption
Bai, J., Mao, Y., Yan, C., Li, Y., Pang, H., & Yu, X. (2026) · ACS Applied Polymer Materials · doi:10.1021/acsapm.6c01297
Shen, S., Fan, X., Liang, W., Xie, C., Zhang, N., Wang, P., Lin, R., Zhang, J. X., Han, Y., Qiu, C., et al. (2026) · Chemical Engineering Journal · doi:10.1016/j.cej.2026.178705
Highly linear and sensitive crack-based strain sensor based on multi-scale synergistic engineering
Ma, G., Xiong, S., Ma, K., Yan, S., Qiao, Y., Zhang, M., Gu, C., Shen, H., Ba, K., Wang, Y., et al. (2026) · Chemical Engineering Journal · doi:10.1016/j.cej.2026.179326
Biofunctionalized Porous POMaC Films Promote Cell Adhesion and Infiltration for Tissue Interfaces
Sun, H., Twiddy, J. S., Queener, K. M. K., Deal, H. E., Ali, K. M., Zandi, N., Chu, W., Shu, Q., Williams, T. I., Brown, A. C., et al. (2026) · ACS Applied Bio Materials · doi:10.1021/acsabm.6c00307
Li, M., Lo, T., Chang, C.-W., Hsu, Y., Chien, C., Huang, Y.-Y., Wu, C.-T., Chang, C., Chen, B., Su, H.-H., et al. (2026) · Advanced Functional Materials · doi:10.1002/adfm.77529
Lee, D. H., Seimiya, N., & Takei, K. (2026) · Device · doi:10.1016/j.device.2026.101273
Gan, J., Mi, Y., Qiao, H., Huang, Z., Tang, P., & Qi, X. (2026) · The Journal of Physical Chemistry Letters · doi:10.1021/acs.jpclett.6c02196
Li, Y., Li, X., Wu, Y., Jiang, F., Wang, Q., Peng, J., Li, J., & Zhai, M. (2026) · Small · doi:10.1002/smll.75419
Fiber-optic spectroscopy with machine learning-based analysis for skin oxygen saturation assessment
Zhou, H., Hou, Y., Yu, B., Hu, X., Hu, Y., Ma, Y., Chen, H., & Wang, Y. (2026) · Matter & Light · doi:10.1016/j.matlit.2026.100092
Reusable and Soft Self-Adhesive Epidermal Electrodes for Human Skin Enabled by Functional Additives
Bae, S., Lee, D., Hwang, C., & Kim, D. Y. (2026) · Micromachines · doi:10.3390/mi17091066
“The PDE electrodes successfully captured high-fidelity ECG signals with clearly distinguishable PQRST waves (Figure 5b), which are essential for diagnosing cardiovascular conditions [3,4].”
Self-citationCritical Radius for Forming Oriented Few-Layer MoS2 on High-Curvature Nanostructures
Sato, T., Milne, Z. B., Bernal, R. A., Toom, S. R., Liang, J.-H., Rouhani, M., Hobley, J., Jeng, Y., Muratore, C., Glavin, N. R., et al. (2026) · ACS Nano · doi:10.1021/acsnano.6c10469
Salem, N., Shaker, A., Ossaimee, M., Saeed, A., Abouelatta, M., & El‐Rabaie, E. M. (2026) · Results in Physics · doi:10.1016/j.rinp.2026.108749
Wu, F., Ren, J., Li, S., Deng, Y., & Wang, H. (2026) · Langmuir · doi:10.1021/acs.langmuir.6c03688
Ni, Y., Zhao, X., Tong, Y., Tang, Q., & Liu, Y. (2026) · Science China Materials · doi:10.1007/s40843-026-4458-0
Hematologic complications and design challenges in cardiovascular devices
Padovani, D., Afsharimani, N., Cioncolini, A., & Ding, Y. (2026) · Communications Engineering · doi:10.1038/s44172-026-00771-9
“(It is worth noticing that general devices for cardiovascular healthcare based on fl exible and stretchable electronics are also under development 172 .)”
Lee, S., Kim, S., Yoo, J., Kim, J. H., Kang, E. S., Lee, E., Yu, S.-M., Kim, J., An, S., Han, D., et al. (2026) · Advanced Materials · doi:10.1002/adma.75549
Metadata
- Authors
- Hong, Y. J., Jeong, H., Cho, K. W., Lu, N., & Kim, D.
- Affiliations
- Seoul National University (KR)
- The University of Texas at Austin (US)
- Corresponding author
- Lu, Nanshu
- Kim, Dae‐Hyeong
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2019-02-27
- Volume
- 29
- Issue
- 19
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2918664767
- Cited by
- 559
- References
- 298
- Citations by year
- 2026: 35 · 2025: 89 · 2024: 91 · 2023: 95 · 2022: 73 · 2021: 88 · 2020: 66 · 2019: 22
- FWCI
- 21.92
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- Advanced Functional Materials (publishedVersion)
- Seoul National University Open Repository (Seoul National University) (submittedVersion)
- Funders
- Office of Naval Research (N00014‐16‐1‐2044)
- National Research Foundation of Korea
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Keywords
- wearable devices, biomedical implants, flexible electronics, stretchable electronics, soft bioelectronics, cardiovascular monitoring, cardiac pacing, cardiac ablation, tissue engineering, in vitro cardiac models, electrocardiogram, blood pressure monitoring, oxygen saturation monitoring, cardiac repair
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review