Wearable and Implantable Devices for Cardiovascular Healthcare: from Monitoring to Therapy Based on Flexible and Stretchable Electronics
Abstract
Cardiovascular disease is the leading cause of death and has dramatically increased in recent years. Continuous cardiac monitoring is particularly important for early diagnosis and prevention, and flexible and stretchable electronic devices have emerged as effective tools for this purpose. Their thin, soft, and deformable features allow intimate and long‐term integration with biotissues, which enables continuous, high‐fidelity, and sometimes large‐area cardiac monitoring on the skin and/or heart surface. In addition to monitoring, intimate contact is also crucial for high‐precision therapies. Combined with tissue engineering, soft bioelectronics have also demonstrated the capability to repair damaged cardiac tissues. This review highlights the recent advances in wearable and implantable devices based on flexible and stretchable electronics for cardiovascular monitoring and therapy. First, wearable/implantable soft bioelectronics for cardiovascular monitoring (e.g., the electrocardiogram, blood pressure, and oxygen saturation level) are reviewed. Then, advances in cardiovascular therapy based on soft bioelectronics (e.g., mesh pacing, ablation, robotic sleeves, and electronic stents) are discussed. Finally, device‐assisted tissue engineering therapy (e.g., functional electronic scaffolds and in vitro cardiac platforms) is discussed.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Rapid advances in flexible and stretchable soft bio-electronics, provide a viable solution for wearable, comfortable, and continuous health monitoring.”
From A Chest‐Conformable, Wireless Electro‐Mechanical E‐Tattoo for Measuring Multiple Cardiac Time Intervals (2023) · cites this paper as [6]
Citations
Cites
Flexible triboelectric generator
Fan, F.-R., Tian, Z.-Q., & Lin Wang, Z. (2012) · Nano Energy · doi:10.1016/j.nanoen.2012.01.004 · Cited by 6,705
Hydrogels for tissue engineering: scaffold design variables and applications
Drury, J. L., & Mooney, D. J. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00340-5 · Cited by 5,136
Kim, D.-H., Lu, N., Ma, R., Kim, Y.-S., Kim, R.-H., Wang, S., Wu, J., Won, S. M., Tao, H., Islam, A., et al. (2011) · Science · doi:10.1126/science.1206157 · Cited by 4,836
Self-citationAdult Cardiac Stem Cells Are Multipotent and Support Myocardial Regeneration
Beltrami, A. P., Barlucchi, L., Torella, D., Baker, M., Limana, F., Chimenti, S., Kasahara, H., Rota, M., Musso, E., Urbanek, K., et al. (2003) · Cell · doi:10.1016/s0092-8674(03)00687-1 · Cited by 3,528
Kocher, A. A., Schuster, M., Szabolcs, M., Takuma, S., Burkhoff, D., Wang, J., Homma, S., Edwards, N. M., & Itescu, S. (2001) · Nature Medicine · doi:10.1038/86498 · Cited by 2,524
Approaches to catheter ablation for persistent atrial fibrillation
Verma, A., Jiang, C.-Y., Betts, T. R., Chen, J., Deisenhofer, I., Mantovan, R., Macle, L., Morillo, C. A., Haverkamp, W., Weerasooriya, R., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1408288 · Cited by 2,339
Strauer, B. E., Brehm, M. U., Zeus, T., Köstering, M., Hernandez, A., Sorg, R. V., Kögler, G., & Wernet, P. (2002) · Circulation · doi:10.1161/01.cir.0000034046.87607.1c · Cited by 2,065
Cryoballoon or Radiofrequency Ablation for Paroxysmal Atrial Fibrillation
Kuck, K.-H., Brugada, J., Fürnkranz, A., Metzner, A., Ouyang, F., Chun, K. R. J., Elvan, A., Arentz, T., Bestehorn, K., Pocock, S. J., et al. (2016) · New England Journal of Medicine · doi:10.1056/nejmoa1602014 · Cited by 1,950
Flexible Nanogenerators for Energy Harvesting and Self‐Powered Electronics
Fan, F. R., Tang, W., & Wang, Z. L. (2016) · Advanced Materials · doi:10.1002/adma.201504299 · Cited by 1,933
Rapid casting of patterned vascular networks for perfusable engineered three-dimensional tissues
Miller, J. S., Stevens, K. R., Yang, M. T., Baker, B. M., Nguyen, D.-H. T., Cohen, D. M., Toro, E., Chen, A. A., Galie, P. A., Yu, X., et al. (2012) · Nature Materials · doi:10.1038/nmat3357 · Cited by 1,917
Flagged first, then by citations
1 of the 298 references couldn’t be matched to a known paper.
Research works printed but not linked: 15
- Jeong H., 2017, 39th Annu. Int. Conf. of IEEE Eng. Med. Biol. Soc.,
- Lonini L., 2017, Proc. 2017 ACM Int. Joint Conf. Pervasive and Ubiquitous Comput. and Proc. 2017 ACM Int. Symp. Wearable Comput.
- Webster J. G., 2009, Medical Instrumentation: Application and Design, 4th Edition
- Cong P., 2009, IEEE Int. Solid‐State Circuits Conf.
- Penaz J., 1973, Digest of the 10th Int. Conf. Med. Biol. Eng.
- Zhang H. L., 2014, Sci. World J., 2014, 404913
- Alraies M. C., 2014, J. Thorac. Dis., 6, 1120
- Reis Filho J. R., 2015, Arq. Bras. Cardiol., 104, 502
- Jhun C.‐S., 2010, Computational Cardiovascular Mechanics: Modelling and Applications in Heart Failure
- Roche E. T., 2015, Proc. ASME 2015 Int. Des. Eng. Tech. Conf. Comput. Inf. Eng. Conf.
- Horvath M. A., 2015, Proc. ASME 2015 Int. Des. Eng. Tech. Conf. Comput. Inf. Eng. Conf.
- Waksman R., 2016, Cirs.: Cardiovasc. Intervention, 9, e004150
- Jia H., 2018, Adv. Polym. Technol., 00, 1
- Park J., 2017, 19th Int. Conf. Solid‐State Sensors, Actuators and Microsystems
- 10.1038/nmat3404 · DOI · Paper page
Cited by
Sorted by citations
Wearable Pressure Sensors for Pulse Wave Monitoring
Meng, K., Xiao, X., Wei, W., Chen, G., Nashalian, A., Shen, S., Xiao, X., & Chen, J. (2022) · Advanced Materials · doi:10.1002/adma.202109357 · Cited by 900
Multifunctional materials for implantable and wearable photonic healthcare devices
Lee, G., Moon, H., Kim, H., Lee, G. H., Kwon, W., Yoo, S., Myung, D. J., Yun, S. H., Bao, Z., & Hahn, S. K. (2020) · Nature Reviews Materials · doi:10.1038/s41578-019-0167-3 · Cited by 683
Stretchable Electronics Based on PDMS Substrates
Qi, D., Zhang, K., Tian, G., Jiang, B., & Huang, Y. (2020) · Advanced Materials · doi:10.1002/adma.202003155 · Cited by 672
Zhang, L., Kumar, K. S., He, H., Cai, C. J., He, X., Gao, H., Yue, S., Li, C., Seet, R. C.-S., Ren, H., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-18503-8 · Cited by 574
Multifunctional conductive hydrogel-based flexible wearable sensors
Wang, L., Xu, T., & Zhang, X. (2021) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2020.116130 · Cited by 507
Metadata
- Authors
- Hong, Y. J., Jeong, H., Cho, K. W., Lu, N., & Kim, D.
- Affiliations
- Seoul National University (KR)
- The University of Texas at Austin (US)
- Corresponding author
- Lu, Nanshu
- Kim, Dae‐Hyeong
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2019-02-27
- Volume
- 29
- Issue
- 19
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2918664767
- Cited by
- 559
- References
- 298
- Citations by year
- 2026: 35 · 2025: 89 · 2024: 91 · 2023: 95 · 2022: 73 · 2021: 88 · 2020: 66 · 2019: 22
- FWCI
- 21.92
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- Advanced Functional Materials (publishedVersion)
- Seoul National University Open Repository (Seoul National University) (submittedVersion)
- Funders
- Office of Naval Research (N00014‐16‐1‐2044)
- National Research Foundation of Korea
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Keywords
- wearable devices, biomedical implants, flexible electronics, stretchable electronics, soft bioelectronics, cardiovascular monitoring, cardiac pacing, cardiac ablation, tissue engineering, in vitro cardiac models, electrocardiogram, blood pressure monitoring, oxygen saturation monitoring, cardiac repair
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›