The DOI matches its Crossref record; 297 of the 298 references it cites were found in a registry or an index.
Wearable and Implantable Devices for Cardiovascular Healthcare: from Monitoring to Therapy Based on Flexible and Stretchable Electronics
Abstract
Cardiovascular disease is the leading cause of death and has dramatically increased in recent years. Continuous cardiac monitoring is particularly important for early diagnosis and prevention, and flexible and stretchable electronic devices have emerged as effective tools for this purpose. Their thin, soft, and deformable features allow intimate and long‐term integration with biotissues, which enables continuous, high‐fidelity, and sometimes large‐area cardiac monitoring on the skin and/or heart surface. In addition to monitoring, intimate contact is also crucial for high‐precision therapies. Combined with tissue engineering, soft bioelectronics have also demonstrated the capability to repair damaged cardiac tissues. This review highlights the recent advances in wearable and implantable devices based on flexible and stretchable electronics for cardiovascular monitoring and therapy. First, wearable/implantable soft bioelectronics for cardiovascular monitoring (e.g., the electrocardiogram, blood pressure, and oxygen saturation level) are reviewed. Then, advances in cardiovascular therapy based on soft bioelectronics (e.g., mesh pacing, ablation, robotic sleeves, and electronic stents) are discussed. Finally, device‐assisted tissue engineering therapy (e.g., functional electronic scaffolds and in vitro cardiac platforms) is discussed.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Rapid advances in flexible and stretchable soft bio-electronics, provide a viable solution for wearable, comfortable, and continuous health monitoring.”
From A Chest‐Conformable, Wireless Electro‐Mechanical E‐Tattoo for Measuring Multiple Cardiac Time Intervals (2023) · cites this paper as [6]
Citations
Cites
Flexible triboelectric generator
Fan, F.-R., Tian, Z.-Q., & Lin Wang, Z. (2012) · Nano Energy · doi:10.1016/j.nanoen.2012.01.004 · Cited by 6,705
Hydrogels for tissue engineering: scaffold design variables and applications
Drury, J. L., & Mooney, D. J. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00340-5 · Cited by 5,136
Kim, D.-H., Lu, N., Ma, R., Kim, Y.-S., Kim, R.-H., Wang, S., Wu, J., Won, S. M., Tao, H., Islam, A., et al. (2011) · Science · doi:10.1126/science.1206157 · Cited by 4,836
Self-citationAdult Cardiac Stem Cells Are Multipotent and Support Myocardial Regeneration
Beltrami, A. P., Barlucchi, L., Torella, D., Baker, M., Limana, F., Chimenti, S., Kasahara, H., Rota, M., Musso, E., Urbanek, K., et al. (2003) · Cell · doi:10.1016/s0092-8674(03)00687-1 · Cited by 3,528
Kocher, A. A., Schuster, M., Szabolcs, M., Takuma, S., Burkhoff, D., Wang, J., Homma, S., Edwards, N. M., & Itescu, S. (2001) · Nature Medicine · doi:10.1038/86498 · Cited by 2,524
Approaches to catheter ablation for persistent atrial fibrillation
Verma, A., Jiang, C.-Y., Betts, T. R., Chen, J., Deisenhofer, I., Mantovan, R., Macle, L., Morillo, C. A., Haverkamp, W., Weerasooriya, R., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1408288 · Cited by 2,339
Strauer, B. E., Brehm, M. U., Zeus, T., Köstering, M., Hernandez, A., Sorg, R. V., Kögler, G., & Wernet, P. (2002) · Circulation · doi:10.1161/01.cir.0000034046.87607.1c · Cited by 2,065
Cryoballoon or Radiofrequency Ablation for Paroxysmal Atrial Fibrillation
Kuck, K.-H., Brugada, J., Fürnkranz, A., Metzner, A., Ouyang, F., Chun, K. R. J., Elvan, A., Arentz, T., Bestehorn, K., Pocock, S. J., et al. (2016) · New England Journal of Medicine · doi:10.1056/nejmoa1602014 · Cited by 1,950
Flexible Nanogenerators for Energy Harvesting and Self‐Powered Electronics
Fan, F. R., Tang, W., & Wang, Z. L. (2016) · Advanced Materials · doi:10.1002/adma.201504299 · Cited by 1,933
Rapid casting of patterned vascular networks for perfusable engineered three-dimensional tissues
Miller, J. S., Stevens, K. R., Yang, M. T., Baker, B. M., Nguyen, D.-H. T., Cohen, D. M., Toro, E., Chen, A. A., Galie, P. A., Yu, X., et al. (2012) · Nature Materials · doi:10.1038/nmat3357 · Cited by 1,917
Mangi, A. A., Noiseux, N., Kong, D., He, H., Rezvani, M., Ingwall, J. S., & Dzau, V. J. (2003) · Nature Medicine · doi:10.1038/nm912 · Cited by 1,506
Wearable sensors: modalities, challenges, and prospects
Heikenfeld, J., Jajack, A., Rogers, J., Gutruf, P., Tian, L., Pan, T., Li, R., Khine, M., Kim, J., Wang, J., et al. (2018) · Lab on a Chip · doi:10.1039/c7lc00914c · Cited by 1,434
Monitoring of Vital Signs with Flexible and Wearable Medical Devices
Khan, Y., Ostfeld, A. E., Lochner, C. M., Pierre, A., & Arias, A. C. (2016) · Advanced Materials · doi:10.1002/adma.201504366 · Cited by 1,408
Xu, S., Zhang, Y., Cho, J., Lee, J., Huang, X., Jia, L., Fan, J. A., Su, Y., Su, J., Zhang, H., et al. (2013) · Nature Communications · doi:10.1038/ncomms2553 · Cited by 1,404
Autologous bone-marrow stem-cell transplantation for myocardial regeneration
Stamm, C., Westphal, B., Kleine, H., Petzsch, M., Kittner, C., Klinge, H., Schümichen, C., Nienaber, C. A., Freund, M., & Steinhoff, G. (2003) · The Lancet · doi:10.1016/s0140-6736(03)12110-1 · Cited by 1,354
TRANSLUMINAL DILATATION OF CORONARY-ARTERY STENOSIS
Grüntzig, A. (1978) · The Lancet · doi:10.1016/s0140-6736(78)90500-7 · Cited by 1,348
Soft Microfluidic Assemblies of Sensors, Circuits, and Radios for the Skin
Xu, S., Zhang, Y., Jia, L., Mathewson, K. E., Jang, K.-I., Kim, J., Fu, H., Huang, X., Chava, P., Wang, R., et al. (2014) · Science · doi:10.1126/science.1250169 · Cited by 1,199
Stem-cell therapy for cardiac disease
Segers, V. F. M., & Lee, R. T. (2008) · Nature · doi:10.1038/nature06800 · Cited by 1,192
Monolayered mesenchymal stem cells repair scarred myocardium after myocardial infarction
Miyahara, Y., Nagaya, N., Kataoka, M., Yanagawa, B., Tanaka, K., Hao, H., Ishino, K., Ishida, H., Shimizu, T., Kangawa, K., et al. (2006) · Nature Medicine · doi:10.1038/nm1391 · Cited by 1,190
Inflammation-free, gas-permeable, lightweight, stretchable on-skin electronics with nanomeshes
Miyamoto, A., Lee, S., Cooray, N. F., Lee, S., Mori, M., Matsuhisa, N., Jin, H., Yoda, L., Yokota, T., Itoh, A., et al. (2017) · Nature Nanotechnology · doi:10.1038/nnano.2017.125 · Cited by 1,181
Lee, H., Song, C., Hong, Y. S., Kim, M., Cho, H. R., Kang, T., Shin, K., Choi, S. H., Hyeon, T., & Kim, D.-H. (2017) · Science Advances · doi:10.1126/sciadv.1601314 · Cited by 1,118
Self-citationRecent Advances in Flexible and Stretchable Bio‐Electronic Devices Integrated with Nanomaterials
Choi, S., Lee, H., Ghaffari, R., Hyeon, T., & Kim, D. (2016) · Advanced Materials · doi:10.1002/adma.201504150 · Cited by 1,104
Self-citationUltraflexible organic photonic skin
Yokota, T., Zalar, P., Kaltenbrunner, M., Jinno, H., Matsuhisa, N., Kitanosako, H., Tachibana, Y., Yukita, W., Koizumi, M., & Someya, T. (2016) · Science Advances · doi:10.1126/sciadv.1501856 · Cited by 1,024
Advances in organ-on-a-chip engineering
Zhang, B., Korolj, A., Lai, B. F. L., & Radisic, M. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0034-7 · Cited by 1,017
Dağdeviren, C., Su, Y., Joe, P., Yona, R., Liu, Y., Kim, Y., Huang, Y., Damadoran, A. R., Xia, J., Martin, L. W., et al. (2014) · Nature Communications · doi:10.1038/ncomms5496 · Cited by 997
Choi, S., Han, S. I., Jung, D., Hwang, H. J., Lim, C., Bae, S., Park, O. K., Tschabrunn, C. M., Lee, M., Bae, S. Y., et al. (2018) · Nature Nanotechnology · doi:10.1038/s41565-018-0226-8 · Cited by 984
Self-citationConformal piezoelectric energy harvesting and storage from motions of the heart, lung, and diaphragm
Dagdeviren, C., Yang, B. D., Su, Y., Tran, P. L., Joe, P., Anderson, E., Xia, J., Doraiswamy, V., Dehdashti, B., Feng, X., et al. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1317233111 · Cited by 975
Son, D., Kang, J., Vardoulis, O., Kim, Y., Matsuhisa, N., Oh, J. Y., To, J. W. F., Mun, J., Katsumata, T., Liu, Y., et al. (2018) · Nature Nanotechnology · doi:10.1038/s41565-018-0244-6 · Cited by 947
Vascularization Strategies for Tissue Engineering
Lovett, M. L., Lee, K., Edwards, A., & Kaplan, D. L. (2009) · Tissue Engineering Part B Reviews · doi:10.1089/ten.teb.2009.0085 · Cited by 923
Radisic, M., Park, H., Shing, H., Consi, T. R., Schöen, F. J., Langer, R., Freed, L. E., & Vunjak‐Novakovic, G. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0407817101 · Cited by 913
Wearable photoplethysmographic sensors—past and present
Tamura, T., Maeda, Y., Sekine, M., & Yoshida, M. (2014) · Electronics · doi:10.3390/electronics3020282 · Cited by 912
Monitoring of the central blood pressure waveform via a conformal ultrasonic device
Wang, C., Li, X., Hu, H., Zhang, L., Huang, Z., Lin, M., Zhang, Z., Yin, Z., Huang, B., Gong, H., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0287-x · Cited by 895
Nobuyoshi, M., Kimura, T., Nosaka, H., Mioka, S., Ueno, K., 横井, 博., Hamasaki, N., Horiuchi, H., & Ohishi, H. (1988) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(88)80046-9 · Cited by 875
Instrumented cardiac microphysiological devices via multimaterial three-dimensional printing
Lind, J. U., Busbee, T. A., Valentine, A. D., Pasqualini, F. S., Yuan, H., Yadid, M., Park, S.-J., Kotikian, A., Nesmith, A. P., Campbell, P. H., et al. (2017) · Nature Materials · doi:10.1038/nmat4782 · Cited by 863
Accordion-like honeycombs for tissue engineering of cardiac anisotropy
Engelmayr, G. C., Cheng, M., Bettinger, C. J., Borenstein, J. T., Langer, R., & Freed, L. E. (2008) · Nature Materials · doi:10.1038/nmat2316 · Cited by 848
Multifunctional Epidermal Electronics Printed Directly Onto the Skin
Yeo, W., Kim, Y., Lee, J., Ameen, A., Shi, L., Li, M., Wang, S., Ma, R., Jin, S. H., Kang, Z., et al. (2013) · Advanced Materials · doi:10.1002/adma.201204426 · Cited by 837
Highly‐Efficient, Flexible Piezoelectric PZT Thin Film Nanogenerator on Plastic Substrates
Park, K., Son, J. H., Hwang, G., Jeong, C. K., Ryu, J., Koo, M., Choi, I., Lee, S. H., Byun, M., Wang, Z. L., et al. (2014) · Advanced Materials · doi:10.1002/adma.201305659 · Cited by 835
A photolabile hydrogel for guided three-dimensional cell growth and migration
Luo, Y., & Shoichet, M. S. (2004) · Nature Materials · doi:10.1038/nmat1092 · Cited by 801
Kumar, A., Añel, R., Bunnell, E., Habet, K. J., Zanotti, S. L., Marshall, S., Neumann, A., Ali, A., Cheang, M., Kavinsky, C. J., et al. (2004) · Critical Care Medicine · doi:10.1097/01.ccm.0000114996.68110.c9 · Cited by 790
Enzyme‐Based Glucose Sensor: From Invasive to Wearable Device
Lee, H., Hong, Y. J., Baik, S., Hyeon, T., & Kim, D. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201701150 · Cited by 778
Self-citationKim, D., Lu, N., Ghaffari, R., Kim, Y., Lee, S. P., Xu, L., Wu, J. C., Kim, R.-H., Song, J., Liu, Z., et al. (2011) · Nature Materials · doi:10.1038/nmat2971 · Cited by 766
Self-citationNanowired three-dimensional cardiac patches
Dvir, T., Timko, B. P., Brigham, M. D., Naik, S. R., Karajanagi, S. S., Levy, O., Jin, H., Parker, K. K., Langer, R., & Kohane, D. S. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.160 · Cited by 763
Drug-Eluting Coronary-Artery Stents
Stefanini, G. G., & Holmes, D. R. (2013) · New England Journal of Medicine · doi:10.1056/nejmra1210816 · Cited by 740
All-organic optoelectronic sensor for pulse oximetry
Lochner, C. M., Khan, Y., Pierre, A., & Arias, A. C. (2014) · Nature Communications · doi:10.1038/ncomms6745 · Cited by 734
Nanopatterned Textile-Based Wearable Triboelectric Nanogenerator
Seung, W., Gupta, M. K., Lee, K. Y., Shin, K.-S., Lee, J., Kim, T. Y., Kim, S., Lin, J., Kim, J. H., & Kim, S. (2015) · ACS Nano · doi:10.1021/nn507221f · Cited by 723
Jakus, A. E., Secor, E. B., Rutz, A. L., Jordan, S. W., Hersam, M. C., & Shah, R. N. (2015) · ACS Nano · doi:10.1021/acsnano.5b01179 · Cited by 722
Choi, M. K., Yang, J., Kang, K., Kim, D. C., Choi, C., Park, C., Kim, S. J., Chae, S. I., Kim, J. H., Kim, J. H., et al. (2015) · Nature Communications · doi:10.1038/ncomms8149 · Cited by 719
Self-citationHwang, G., Park, H., Lee, J., Oh, S., Park, K., Byun, M., Park, H., Ahn, G., Jeong, C. K., No, K., et al. (2014) · Advanced Materials · doi:10.1002/adma.201400562 · Cited by 672
Cell sheet engineering for myocardial tissue reconstruction
Shimizu, T., Yamato, M., Kikuchi, A., & Okano, T. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00110-8 · Cited by 672
Graphene Electronic Tattoo Sensors
Kabiri Ameri, S., Ho, R., Jang, H., Tao, L., Wang, Y., Wang, L., Schnyer, D. M., Akinwande, D., & Lu, N. (2017) · ACS Nano · doi:10.1021/acsnano.7b02182 · Cited by 669
Self-citationA Sensitive and Biodegradable Pressure Sensor Array for Cardiovascular Monitoring
Boutry, C. M., Nguyen, A., Lawal, Q. O., Chortos, A., Rondeau‐Gagné, S., & Bao, Z. (2015) · Advanced Materials · doi:10.1002/adma.201502535 · Cited by 653
Electrospun fine-textured scaffolds for heart tissue constructs
Zong, X., Bien, H., Chung, C.-Y., Yin, L., Fang, D., Hsiao, B. S., Chu, B., & Entcheva, E. G. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.01.052 · Cited by 643
Macroporous Nanowire Nanoelectronic Scaffolds for Synthetic Tissues
Jia Liu, B., Dvir, T., Jin, L., Tsui, J. H., Qing, Q., Suo, Z., Langer, R., Kohane, D. S., Lieber, C. M., & Tian, B. (2012) · Digital Access to Scholarship at Harvard (DASH) (Harvard University) · Cited by 642
Xu, L., Gutbrod, S. R., Bonifas, A. P., Su, Y., Sulkin, M. S., Lu, N., Chung, H.-J., Jang, K.-I., Liu, Z., Ying, M., et al. (2014) · Nature Communications · doi:10.1038/ncomms4329 · Cited by 634
Self-citationReverse‐Micelle‐Induced Porous Pressure‐Sensitive Rubber for Wearable Human–Machine Interfaces
Jung, S., Kim, J. H., Kim, J., Choi, S., Lee, J., Park, I., Hyeon, T., & Kim, D. (2014) · Advanced Materials · doi:10.1002/adma.201401364 · Cited by 628
Self-citationPiezoelectric nanogenerators – a review of nanostructured piezoelectric energy harvesters
Briscoe, J., & Dunn, S. (2015) · Nano Energy · doi:10.1016/j.nanoen.2014.11.059 · Cited by 617
Developments in metallic biodegradable stents☆
Hermawan, H., Dube, D., & Mantovani, D. (2009) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.10.006 · Cited by 607
In Vivo Powering of Pacemaker by Breathing‐Driven Implanted Triboelectric Nanogenerator
Zheng, Q., Shi, B., Fan, F., Wang, X., Yan, L., Yuan, W., Wang, S., Liu, H., Li, Z., & Wang, Z. L. (2014) · Advanced Materials · doi:10.1002/adma.201402064 · Cited by 603
Tissue–electronics interfaces: from implantable devices to engineered tissues
Feiner, R., & Dvir, T. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2017.76 · Cited by 595
Zhang, B., Montgomery, M., Chamberlain, M. D., Ogawa, S., Korolj, A., Pahnke, A., Wells, L. A., Massé, S., Kim, J., Reis, L., et al. (2016) · Nature Materials · doi:10.1038/nmat4570 · Cited by 593
Lim, S., Son, D., Kim, J., Lee, Y. B., Song, J., Choi, S., Lee, D. J., Kim, J. H., Lee, M., Hyeon, T., et al. (2015) · Advanced Functional Materials · doi:10.1002/adfm.201402987 · Cited by 582
Self-citationChoi, S., Park, J., Hyun, W., Kim, J., Kim, J., Lee, Y. B., Song, C., Hwang, H. J., Kim, J. H., Hyeon, T., et al. (2015) · ACS Nano · doi:10.1021/acsnano.5b02790 · Cited by 568
Self-citationKoo, J. H., Kim, D. C., Shim, H. J., Kim, T., & Kim, D. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201801834 · Cited by 563
Self-citationPrognostic Value of the Admission Electrocardiogram in Acute Coronary Syndromes
Savonitto, S. (1999) · JAMA · doi:10.1001/jama.281.8.707 · Cited by 558
Akiyama, Y., Kikuchi, A., Yamato, M., & Okano, T. (2004) · Langmuir · doi:10.1021/la036139f · Cited by 552
Choi, C., Choi, M. K., Liu, S., Kim, M., Park, O. K., Im, C., Kim, J., Qin, X., Lee, G. J., Cho, K. W., et al. (2017) · Nature Communications · doi:10.1038/s41467-017-01824-6 · Cited by 551
Self-citationThree-dimensional integrated stretchable electronics
Huang, Z., Hao, Y., Li, Y., Hu, H., Wang, C., Nomoto, A., Pan, T., Gu, Y., Chen, Y., Zhang, T., et al. (2018) · Nature Electronics · doi:10.1038/s41928-018-0116-y · Cited by 551
Kim, J., Li, A. W., Choi, Y., Lewin, S. A., Verbeke, C. S., Dranoff, G., & Mooney, D. J. (2014) · Nature Biotechnology · doi:10.1038/nbt.3071 · Cited by 546
Wireless power transfer to deep-tissue microimplants
Ho, J. S., Yeh, A. J., Neofytou, E., Kim, S., Tanabe, Y., Patlolla, B., Beygui, R. E., & Poon, A. S. Y. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1403002111 · Cited by 541
Flexible and Stretchable Electronics Paving the Way for Soft Robotics
Lu, N., & Kim, D. (2013) · Soft Robotics · doi:10.1089/soro.2013.0005 · Cited by 538
Self-citationDagdeviren, C., Shi, Y., Joe, P., Ghaffari, R., Balooch, G., Usgaonkar, K., Gur, O., Tran, P. L., Crosby, J. R., Meyer, M., et al. (2015) · Nature Materials · doi:10.1038/nmat4289 · Cited by 513
Three-Year Follow-up after Implantation of Metallic Coronary-Artery Stents
Kimura, T., Yokoi, H., Nakagawa, Y., Tamura, T., Kaburagi, S., Sawada, Y., Sato, Y., 横井, 博., Hamasaki, N., Nosaka, H., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199602293340903 · Cited by 505
Schächinger, V., Erbs, S., Elsässer, A., Haberbosch, W., Hambrecht, R., Hölschermann, H., Yu, J., Corti, R., Mathey, D. G., Hamm, C. W., et al. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl388 · Cited by 505
Barrett, P. M., Komatireddy, R., Haaser, S., Topol, S., Sheard, J., Encinas, J., Fought, A. J., & Topol, E. J. (2014) · The American Journal of Medicine · doi:10.1016/j.amjmed.2013.10.003 · Cited by 498
Piezoelectric Ribbons Printed onto Rubber for Flexible Energy Conversion
Qi, Y. P., Jafferis, N. T., Lyons, K., Lee, C. M., Ahmad, H. M. N., & McAlpine, M. C. (2010) · Nano Letters · doi:10.1021/nl903377u · Cited by 496
Williams, K. J., & Tabas, I. A. (2006) · Circulation · doi:10.1161/circulationaha.105.606962 · Cited by 486
Reddy, V. Y., Shah, D. C., Kautzner, J., Schmidt, B., Saoudi, N. C., Herrera‐Siklody, C., Jaı̈s, P., Hindricks, G., Peichl, P., Yulzari, A., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2012.07.016 · Cited by 486
Wu, Y., Wang, L., Guo, B., & Ma, P. X. (2017) · ACS Nano · doi:10.1021/acsnano.7b01062 · Cited by 477
Kim, T., Park, J., Sohn, J., Cho, D., & Jeon, S. (2016) · ACS Nano · doi:10.1021/acsnano.6b01355 · Cited by 474
Bartúnek, J., Vanderheyden, M., Vandekerckhove, B., Mansour, S., Bruyne, B. D., Bondt, P. D., Haute, I. V., Lootens, N., Heyndrickx, G. R., & Wijns, W. C. (2005) · Circulation · doi:10.1161/circulationaha.104.522292 · Cited by 464
Feiner, R., Engel, L., Fleischer, S., Malki, M., Gal, I., Shapira, A., Shacham‐Diamand, Y., & Dvir, T. (2016) · Nature Materials · doi:10.1038/nmat4590 · Cited by 460
(1997) · Institute of Physics eBooks · doi:10.1887/0750304677 · Cited by 455
In Vivo Self-Powered Wireless Cardiac Monitoring via Implantable Triboelectric Nanogenerator
Zheng, Q., Zhang, H., Shi, B., Xue, X., Liu, Z., Jin, Y., Ma, Y., Zou, Y., Wang, X., An, Z., et al. (2016) · ACS Nano · doi:10.1021/acsnano.6b02693 · Cited by 449
Self-assembled three dimensional network designs for soft electronics
Jang, K.-I., Li, K., Chung, H. U., Xu, S., Jung, H. N., Yang, Y., Kwak, J. W., Jung, H. H., Song, J., Yang, C., et al. (2017) · Nature Communications · doi:10.1038/ncomms15894 · Cited by 445
Percutaneous Transluminal Coronary Angioplasty
Landau, C., Lange, R. A., & Hillis, L. D. (1994) · New England Journal of Medicine · doi:10.1056/nejm199404073301407 · Cited by 443
Soft robotic sleeve supports heart function
Roche, E. T., Horvath, M. A., Wamala, I., Alazmani, A., Song, S., Whyte, W., Machaidze, Z., Payne, C. J., Weaver, J. C., Fishbein, G. A., et al. (2017) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf3925 · Cited by 435
Central Pressure: Variability and Impact of Cardiovascular Risk Factors
McEniery, C. M., Yasmin, Y., McDonnell, B. J., Munnery, M. M., Wallace, S. M. L., Rowe, C. V., Cockcroft, J. R., & Wilkinson, I. B. (2008) · Hypertension · doi:10.1161/hypertensionaha.107.105445 · Cited by 429
Therapeutic approaches for cardiac regeneration and repair
Hashimoto, H., Olson, E. N., & Bassel‐Duby, R. (2018) · Nature Reviews Cardiology · doi:10.1038/s41569-018-0036-6 · Cited by 428
A Conformal, Bio-Interfaced Class of Silicon Electronics for Mapping Cardiac Electrophysiology
Viventi, J., Kim, D., Moss, J. D., Kim, Y., Blanco, J. A., Annetta, N. V., Hicks, A., Xiao, J., Huang, Y., Callans, D. J., et al. (2010) · Science Translational Medicine · doi:10.1126/scitranslmed.3000738 · Cited by 419
Self-citationBattery-free, stretchable optoelectronic systems for wireless optical characterization of the skin
Kim, J., Salvatore, G. A., Araki, H., Chiarelli, A. M., Xie, Z., Banks, A. R., Sheng, X., Liu, Y., Lee, J. W., Jang, K., et al. (2016) · Science Advances · doi:10.1126/sciadv.1600418 · Cited by 411
Self-citationFlexible shape-memory scaffold for minimally invasive delivery of functional tissues
Montgomery, M., Ahadian, S., Davenport Huyer, L., Lo Rito, M., Civitarese, R. A., Vanderlaan, R. D., Wu, J., Reis, L. A., Momen, A., Akbari, S., et al. (2017) · Nature Materials · doi:10.1038/nmat4956 · Cited by 409
Liu, Y., Norton, J. J. S., Qazi, R., Zou, Z., Ammann, K. R., Liu, H., Yan, L., Tran, P. L., Jang, K.-I., Lee, J. W., et al. (2016) · Science Advances · doi:10.1126/sciadv.1601185 · Cited by 397
Jang, K., Han, S. Y., Xu, S. H., Mathewson, K. E., Zhang, Y., Jeong, J., Kim, G.-T., Webb, R. C., Lee, J. W., Dawidczyk, T. J., et al. (2014) · Nature Communications · doi:10.1038/ncomms5779 · Cited by 392
Printed multifunctional flexible device with an integrated motion sensor for health care monitoring
Yamamoto, Y., Harada, S., Yamamoto, D., Honda, W., Arie, T., Akita, S., & Takei, K. (2016) · Science Advances · doi:10.1126/sciadv.1601473 · Cited by 385
Liu, B., Lee, B. W., Nakanishi, K., Villasante, A., Williamson, R., Metz, J. B., Kim, J.-H., Kanai, M., Bi, L., Brown, K. R., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0229-7 · Cited by 379
Kautzner, J., Neužil, P., Lambert, H., Peichl, P., Petrů, J., Cihak, R. J., Skoda, J., Wichterle, D., Wißner, E., Yulzari, A., et al. (2015) · EP Europace · doi:10.1093/europace/euv057 · Cited by 374
Ma, Y., Zheng, Q., Liu, Y., Shi, B., Xue, X., Ji, W., Liu, Z., Jin, Y., Zou, Y., An, Z., et al. (2016) · Nano Letters · doi:10.1021/acs.nanolett.6b01968 · Cited by 367
(1997) · Series in medical physics and biomedical engineering · doi:10.1201/9781420050790 · Cited by 364
Fabric‐Based Integrated Energy Devices for Wearable Activity Monitors
Jung, S., Lee, J., Hyeon, T., Lee, M., & Kim, D. (2014) · Advanced Materials · doi:10.1002/adma.201402439 · Cited by 358
Self-citationDevice-assisted transdermal drug delivery
Lee, H., Song, C., Baik, S., Kim, D., Hyeon, T., & Kim, D.-H. (2017) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2017.08.009 · Cited by 353
Self-citationMortality and Cost Associated With Cardiovascular Implantable Electronic Device Infections
Sohail, M. R. (2011) · Archives of Internal Medicine · doi:10.1001/archinternmed.2011.441 · Cited by 350
Zartner, P. A., Cesnjevar, R. A., Singer, H., & Weyand, M. (2005) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.20520 · Cited by 348
Miniaturized Battery‐Free Wireless Systems for Wearable Pulse Oximetry
Kim, J., Gutruf, P., Chiarelli, A. M., Heo, S. Y., Cho, K., Xie, Z., Banks, A. R., Han, S., Jang, K., Lee, J. W., et al. (2016) · Advanced Functional Materials · doi:10.1002/adfm.201604373 · Cited by 334
Self-citationKhan, Y., Garg, M., Gui, Q., Schadt, M. J., Gaikwad, A. M., Han, D., Yamamoto, N. A. D., Hart, P., Welte, R., Wilson, W., et al. (2016) · Advanced Functional Materials · doi:10.1002/adfm.201603763 · Cited by 326
Grafahrend, D., Heffels, K., Beer, M. V., Gasteier, P., Möller, M., Boehm, G., Dalton, P. D., & Gröll, J. (2010) · Nature Materials · doi:10.1038/nmat2904 · Cited by 317
A novel radiofrequency ablation catheter using contact force sensing: Toccata study
Kück, K., Reddy, V. Y., Schmidt, B., Natale, A., Neužil, P., Saoudi, N. C., Kautzner, J., Herrera‐Siklody, C., Hindricks, G., Jaı̈s, P., et al. (2011) · Heart Rhythm · doi:10.1016/j.hrthm.2011.08.021 · Cited by 311
Nanoengineering the Heart: Conductive Scaffolds Enhance Connexin 43 Expression
You, J., Rafat, M., Ye, G. J. C., & Auguste, D. T. (2011) · Nano Letters · doi:10.1021/nl201514a · Cited by 307
“Cut‐and‐Paste” Manufacture of Multiparametric Epidermal Sensor Systems
Yang, S., Chen, Y., Nicolini, L., Pasupathy, P., Sacks, J., Su, B., Yang, R., Sanchez, D., Chang, Y., Wang, P., et al. (2015) · Advanced Materials · doi:10.1002/adma.201502386 · Cited by 304
Self-citationMaterials and Designs for Wireless Epidermal Sensors of Hydration and Strain
Huang, X., Liu, Y., Cheng, H., Shin, W., Fan, J. A., Liu, Z., Lu, C., Kong, G., Chen, K., Patnaik, D., et al. (2014) · Advanced Functional Materials · doi:10.1002/adfm.201303886 · Cited by 302
Principles and techniques of blood pressure measurement
Ogedegbe, G., & Pickering, T. (2002) · Cardiology Clinics · doi:10.1016/j.ccl.2010.07.006 · Cited by 290
Ultrathin Quantum Dot Display Integrated with Wearable Electronics
Kim, J., Shim, H. J., Yang, J., Choi, M. K., Kim, D. C., Kim, J., Hyeon, T., & Kim, D. (2017) · Advanced Materials · doi:10.1002/adma.201700217 · Cited by 282
Self-citationStrategies for Making More Organs Available for Transplantation
Gridelli, B. G., & Remuzzi, G. (2000) · New England Journal of Medicine · doi:10.1056/nejm200008103430606 · Cited by 280
Electrohydrodynamic printing of silver nanowires for flexible and stretchable electronics
Cui, Z., Han, Y., Huang, Q., Dong, J., & Zhu, Y. (2018) · Nanoscale · doi:10.1039/c7nr09570h · Cited by 278
Epidermal Electronics with Advanced Capabilities in Near-Field Communication
Kim, J., Banks, A., Cheng, H., Xie, Z., Xu, S., Jang, K.-I., Lee, J. W., Liu, Z., Gutruf, P., Huang, X., et al. (2015) · Small · doi:10.1002/smll.201402495 · Cited by 274
A Bioinspired Soft Actuated Material
Roche, E. T., Wohlfarth, R., Overvelde, J. T. B., Vasilyev, N. V., Pigula, F. A., Mooney, D. J., Bertoldi, K., & Walsh, C. J. (2013) · Advanced Materials · doi:10.1002/adma.201304018 · Cited by 273
Cell therapy trials for heart regeneration — lessons learned and future directions
Menasché, P. (2018) · Nature Reviews Cardiology · doi:10.1038/s41569-018-0013-0 · Cited by 269
Designed Assembly and Integration of Colloidal Nanocrystals for Device Applications
Yang, J., Choi, M. K., Kim, D., & Hyeon, T. (2015) · Advanced Materials · doi:10.1002/adma.201502851 · Cited by 261
Self-citationKoo, J. H., Jeong, S., Shim, H. J., Son, D., Kim, J., Kim, D. C., Choi, S., Hong, J., & Kim, D. (2017) · ACS Nano · doi:10.1021/acsnano.7b04292 · Cited by 261
Self-citationElectromechanical cardioplasty using a wrapped elasto-conductive epicardial mesh
Park, J., Choi, S., Janardhan, A. H., Lee, S.-Y., Raut, S. S., Soares, J., Shin, K., Yang, S., Lee, C., Kang, K., et al. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aad8568 · Cited by 253
Self-citationWebb, R. C., Ma, Y., Krishnan, S. R., Li, Y., Yoon, S. P., Guo, X., Feng, X., Shi, Y., Seidel, M., Cho, N. H., et al. (2015) · Science Advances · doi:10.1126/sciadv.1500701 · Cited by 247
Recent Advances in Nanogenerator‐Driven Self‐Powered Implantable Biomedical Devices
Mahmud, M. A. P., Huda, N., Farjana, S. H., Asadnia, M., & Lang, C. I. (2017) · Advanced Energy Materials · doi:10.1002/aenm.201701210 · Cited by 247
Fully Stretchable Textile Triboelectric Nanogenerator with Knitted Fabric Structures
Kwak, S. S., Kim, H., Seung, W., Kim, J., Hinchet, R., & Kim, S. (2017) · ACS Nano · doi:10.1021/acsnano.7b05203 · Cited by 247
Bioresorbable Electronic Stent Integrated with Therapeutic Nanoparticles for Endovascular Diseases
Son, D., Lee, J., Lee, D. J., Ghaffari, R., Yun, S., Kim, S. J., Lee, J. E., Cho, H. R., Yoon, S., Yang, S., et al. (2015) · ACS Nano · doi:10.1021/acsnano.5b00651 · Cited by 244
Self-citationGraphene-clad textile electrodes for electrocardiogram monitoring
Yapici, M. K., Alkhidir, T., Samad, Y. A., & Liao, K. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.07.111 · Cited by 241
Electronic sensor and actuator webs for large-area complex geometry cardiac mapping and therapy
Kim, D., Ghaffari, R., Lu, N., Wang, S., Lee, S. P., Keum, H., D’Angelo, R., Klinker, L. E., Su, Y., Lü, C., et al. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1205923109 · Cited by 240
Self-citationYousef, M., Schannwell, C. M., Köstering, M., Zeus, T., Brehm, M. U., & Strauer, B. E. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.02.051 · Cited by 231
Highly flexible, wearable, and disposable cardiac biosensors for remote and ambulatory monitoring
Lee, S. P., Ha, G., Wright, D. E., Ma, Y., Sen-Gupta, E., Haubrich, N. R., Branche, P. C., Li, W., Huppert, G. L., Johnson, M. D., et al. (2018) · npj Digital Medicine · doi:10.1038/s41746-017-0009-x · Cited by 230
Hong, Y. J., Lee, H., Kim, J., Lee, M., Choi, H. J., Hyeon, T., & Kim, D. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201805754 · Cited by 229
Self-citationSilicon nanomembranes for fingertip electronics
Ying, M., Bonifas, A. P., Lu, N., Su, Y., Li, R., Cheng, H., Ameen, A., Huang, Y. Y., & Rogers, J. A. (2012) · Nanotechnology · doi:10.1088/0957-4484/23/34/344004 · Cited by 228
Self-citationSolderable and electroplatable flexible electronic circuit on a porous stretchable elastomer
Jeong, G. S., Baek, D.-H., Jung, H., Song, J. H., Moon, J. H., Hong, S. W., Kim, I. Y., & Lee, S. (2012) · Nature Communications · doi:10.1038/ncomms1980 · Cited by 227
Biomaterial strategies for alleviation of myocardial infarction
Venugopal, J. R., Prabhakaran, M. P., Mukherjee, S., Ravichandran, R., Kai, D., & Ramakrishna, S. (2011) · Journal of The Royal Society Interface · doi:10.1098/rsif.2011.0301 · Cited by 219
Li, W., Wang, J., Ren, J., & Qu, X. (2013) · Advanced Materials · doi:10.1002/adma.201302810 · Cited by 215
Biodegradable Shape Memory Polymers in Medicine
Peterson, G. I., Dobrynin, A. V., & Becker, M. L. (2017) · Advanced Healthcare Materials · doi:10.1002/adhm.201700694 · Cited by 214
Stretchable E‐Skin Apexcardiogram Sensor
You, I., Kim, B., Park, J., Koh, K., Shin, S., Jung, S., & Jeong, U. (2016) · Advanced Materials · doi:10.1002/adma.201600720 · Cited by 213
Pulmonary Vein Isolation Using the Visually Guided Laser Balloon
Dukkipati, S. R., Cuoco, F. A., Kutinsky, I. B., Aryana, A., Bahnson, T. D., Lakkireddy, D., Woollett, I. F., Issa, Z. F., Natale, A., & Reddy, V. Y. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.07.036 · Cited by 212
Gutruf, P., Krishnamurthi, V., Vázquez-Guardado, A., Xie, Z., Banks, A., Su, C.-J., Xu, Y., Haney, C. R., Waters, E. A., Kandela, I., et al. (2018) · Nature Electronics · doi:10.1038/s41928-018-0175-0 · Cited by 210
Cephalopod‐Inspired Miniaturized Suction Cups for Smart Medical Skin
Choi, M. K., Park, O. K., Choi, C., Qiao, S., Ghaffari, R., Kim, J., Lee, D. J., Kim, M., Hyun, W., Kim, S. J., et al. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201500285 · Cited by 209
Self-citationWearable Organic Optoelectronic Sensors for Medicine
Bansal, A. K., Hou, S., Kulyk, O., Bowman, E. M., & Samuel, I. D. W. (2015) · Advanced Materials · doi:10.1002/adma.201403560 · Cited by 205
High‐Resolution Spin‐on‐Patterning of Perovskite Thin Films for a Multiplexed Image Sensor Array
Lee, W., Lee, J., Yun, H., Kim, J., Park, J., Choi, C., Kim, D. C., Seo, H., Lee, H.-Y., Yu, J. W., et al. (2017) · Advanced Materials · doi:10.1002/adma.201702902 · Cited by 205
Self-citationUltraconformable Temporary Tattoo Electrodes for Electrophysiology
Ferrari, L. M., Sudha, S., Tarantino, S., Esposti, R., Bolzoni, F., Cavallari, P., Cipriani, C., Mattoli, V., & Greco, F. (2018) · Advanced Science · doi:10.1002/advs.201700771 · Cited by 202
Dai, X., Zhou, W. M., Gao, T., Jia Liu, B., & Lieber, C. M. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.96 · Cited by 199
Nguyen, L. H., Gao, M., Lin, J., Wu, W., Wang, J., & Chew, S. Y. (2017) · Scientific Reports · doi:10.1038/srep42212 · Cited by 196
Advanced Materials and Devices for Bioresorbable Electronics
Kang, S., Koo, J., Lee, Y., & Rogers, J. A. (2018) · Accounts of Chemical Research · doi:10.1021/acs.accounts.7b00548 · Cited by 195
Next-generation pacemakers: from small devices to biological pacemakers
Cingolani, E., Goldhaber, J. I., & Marbán, E. (2018) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2017.165 · Cited by 194
Pathophysiology of right ventricular failure
Greyson, C. R. (2008) · Critical Care Medicine · doi:10.1097/01.ccm.0000296265.52518.70 · Cited by 193
Zacchigna, S., Martinelli, V. C., Moimas, S., Colliva, A., Anzini, M., Nordio, A., Costa, A., Rehman, M., Vodret, S., Pierro, C., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-04908-z · Cited by 193
Low-cost, μm-thick, tape-free electronic tattoo sensors with minimized motion and sweat artifacts
Wang, Y., Qiu, Y., Ameri, S. K., Jang, H., Dai, Z., Huang, Y., & Lu, N. (2018) · npj Flexible Electronics · doi:10.1038/s41528-017-0019-4 · Cited by 192
Self-citationElectrocardiographic patch devices and contemporary wireless cardiac monitoring
Fung, E., Järvelin, M., Doshi, R. N., Shinbane, J. S., Carlson, S. K., Grazette, L. P., Chang, P. M., Sangha, R. S., Huikuri, H. V., & Peters, N. S. (2015) · Frontiers in Physiology · doi:10.3389/fphys.2015.00149 · Cited by 191
From cardiac tissue engineering to heart-on-a-chip: beating challenges
Zhang, Y. S., Aleman, J., Arneri, A., Bersini, S., Piraino, F., Shin, S. R., Dokmeci, M. R., & Khademhosseini, A. (2015) · Biomedical Materials · doi:10.1088/1748-6041/10/3/034006 · Cited by 191
Lee, H., Lee, Y., Song, C., Cho, H. R., Ghaffari, R., Choi, T. K., Kim, K. H., Lee, Y. B., Ling, D., Lee, H., et al. (2015) · Nature Communications · doi:10.1038/ncomms10059 · Cited by 191
Self-citationUltra-flexible Piezoelectric Devices Integrated with Heart to Harvest the Biomechanical Energy
Lu, B., Chen, Y., Ou, D., Chen, H., Diao, L., Zhang, W., Zheng, J. J., Ma, W., Sun, L., & Feng, X. (2015) · Scientific Reports · doi:10.1038/srep16065 · Cited by 191
Cong, P., Chaimanonart, N., Ko, W. H., & Young, D. J. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2009.2035551 · Cited by 190
3D‐Printing Strong High‐Resolution Antioxidant Bioresorbable Vascular Stents
van Lith, R., Baker, E., Ware, H. O. T., Yang, J. H., Farsheed, A. C., Sun, C., & Ameer, G. A. (2016) · Advanced Materials Technologies · doi:10.1002/admt.201600138 · Cited by 189
Ultra‐Wideband Multi‐Dye‐Sensitized Upconverting Nanoparticles for Information Security Application
Lee, J., Yoo, B., Lee, H.-Y., Cha, G. D., Lee, H. M., Cho, Y.-H., Kim, S. Y., Seo, H., Lee, W., Son, D., et al. (2016) · Advanced Materials · doi:10.1002/adma.201603169 · Cited by 188
Self-citationWearable Force Touch Sensor Array Using a Flexible and Transparent Electrode
Song, J., Son, D., Kim, J., Yoo, Y. J., Lee, G. J., Wang, L., Choi, M. K., Yang, J., Lee, M., Do, K., et al. (2016) · Advanced Functional Materials · doi:10.1002/adfm.201605286 · Cited by 187
Self-citationChoi, M. K., Park, I., Kim, D. C., Joh, E., Park, O. K., Kim, J., Kim, M., Choi, C., Yang, J., Cho, K. W., et al. (2015) · Advanced Functional Materials · doi:10.1002/adfm.201502956 · Cited by 186
Self-citationColombo, A., & Karvouni, E. (2000) · Circulation · doi:10.1161/01.cir.102.4.371 · Cited by 182
Biodegradable stents with elastic memory
Venkatraman, S. S., Tan, L. P., Joso, J. F. D., Boey, Y. C. F., & Wang, X. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.09.002 · Cited by 180
Conformal phased surfaces for wireless powering of bioelectronic microdevices
Agrawal, D. R., Tanabe, Y., Weng, D., Ma, A., Hsu, S., Liao, S.-Y., Zhen, Z., Zhu, Z., Sun, C., Dong, Z., et al. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0043 · Cited by 180
A Transducer for the Continuous External Measurement of Arterial Blood Pressure
Pressman, G. L., & Newgard, P. M. (1963) · IRE Transactions on Bio-Medical Electronics · doi:10.1109/tbmel.1963.4322794 · Cited by 178
LVAD-Induced Reverse Remodeling: Basic and Clinical Implications for Myocardial Recovery
Burkhoff, D., Klotz, S., & MANCINI, D. M. (2006) · Journal of Cardiac Failure · doi:10.1016/j.cardfail.2005.10.012 · Cited by 176
Xu, L., Gutbrod, S. R., Ma, Y., Petrossians, A., Liu, Y., Webb, R. C., Fan, J. A., Yang, Z., Xu, R., Whalen, J. J., et al. (2015) · Advanced Materials · doi:10.1002/adma.201405017 · Cited by 175
A wearable multiplexed silicon nonvolatile memory array using nanocrystal charge confinement
Kim, J., Son, D., Lee, M., Song, C., Song, J.-K., Koo, J. H., Lee, D. J., Shim, H. J., Kim, J. H., Lee, M., et al. (2016) · Science Advances · doi:10.1126/sciadv.1501101 · Cited by 164
Self-citationImperceptible electrooculography graphene sensor system for human–robot interface
Ameri, S. K., Kim, M., Kuang, I. A., Perera, W. K., Alshiekh, M., Jeong, H., Topcu, U., Akinwande, D., & Lu, N. (2018) · npj 2D Materials and Applications · doi:10.1038/s41699-018-0064-4 · Cited by 162
Self-citationYan, Z., Han, M., Shi, Y., Badea, A., Yang, Y., Kulkarni, A. A., Hanson, E., Kandel, M. E., Wen, X., Zhang, F., et al. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1713805114 · Cited by 161
Hong, S., Lee, J., Do, K., Lee, M., Kim, J. H., Lee, S., & Kim, D. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201704353 · Cited by 161
Self-citationStent development and local drug delivery
Regar, E., Sianos, G., & Serruys, P. W. J. C. (2001) · British Medical Bulletin · doi:10.1093/bmb/59.1.227 · Cited by 160
Mittal, S., Shaw, R. E., Michel, K., Palekar, R., Arshad, A., Musat, D. L., Preminger, M. W., Sichrovsky, T., & Steinberg, J. S. (2013) · Heart Rhythm · doi:10.1016/j.hrthm.2013.12.013 · Cited by 157
Protease-degradable electrospun fibrous hydrogels
Wade, R. J., Bassin, E. J., Rodell, C. B., & Burdick, J. A. (2015) · Nature Communications · doi:10.1038/ncomms7639 · Cited by 156
Lind, J. U., Yadid, M., Perkins, I., O’Connor, B. B., Eweje, F., Chantre, C. O., Hemphill, M. A., Yuan, H., Campbell, P. H., Vlassak, J. J., et al. (2017) · Lab on a Chip · doi:10.1039/c7lc00740j · Cited by 156
Dukkipati, S. R., Neužil, P., Kautzner, J., Petrů, J., Wichterle, D., Skoda, J., Cihak, R. J., Peichl, P., Russo, A. D., Pelargonio, G., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2012.01.019 · Cited by 154
Subdermal Flexible Solar Cell Arrays for Powering Medical Electronic Implants
Song, K., Han, J. H., Lim, T., Kim, N., Shin, S., Kim, J., Choo, H., Jeong, S., Kim, Y., Wang, Z. L., et al. (2016) · Advanced Healthcare Materials · doi:10.1002/adhm.201600222 · Cited by 154
Tang, W., Tian, J., Zheng, Q., Yan, L. Y., Wang, J., Li, Z., & Wang, Z. L. (2015) · ACS Nano · doi:10.1021/acsnano.5b03567 · Cited by 154
Modular assembly of thick multifunctional cardiac patches
Fleischer, S., Shapira, A., Feiner, R., & Dvir, T. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1615728114 · Cited by 154
Kim, S. J., Cho, K. W., Cho, H. R., Wang, L., Park, S. Y., Lee, S. E., Hyeon, T., Lu, N., Choi, S. H., & Kim, D. (2016) · Advanced Functional Materials · doi:10.1002/adfm.201504578 · Cited by 152
Self-citationWearable and Implantable Mechanical Energy Harvesters for Self-Powered Biomedical Systems
Hinchet, R., & Kim, S. (2015) · ACS Nano · doi:10.1021/acsnano.5b04855 · Cited by 150
Intracoronary Stem Cell Infusion After Acute Myocardial Infarction
de Jong, R., Houtgraaf, J. H., Samiei, S., Boersma, E. H., & Duckers, H. J. (2014) · Circulation Cardiovascular Interventions · doi:10.1161/circinterventions.113.001009 · Cited by 145
A strain-absorbing design for tissue–machine interfaces using a tunable adhesive gel
Lee, S., Inoue, Y., Kim, D., Reuveny, A., Kuribara, K., Yokota, T., Reeder, J. T., Sekino, M., Sekitani, T., Abe, Y., et al. (2014) · Nature Communications · doi:10.1038/ncomms6898 · Cited by 142
Self-citationSon, D., Koo, J. H., Song, J., Kim, J., Lee, M., Shim, H. J., Park, M., Lee, M., Kim, J. H., & Kim, D. (2015) · ACS Nano · doi:10.1021/acsnano.5b01848 · Cited by 140
Self-citationLaschke, M. W., Strohe, A., Scheuer, C., Eglin, D., Verrier, S., Alini, M., Pohlemann, T., & Menger, M. D. (2009) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.02.006 · Cited by 138
Functional differentiation of human pluripotent stem cells on a chip
Giobbe, G. G., Michielin, F., Luni, C., Giulitti, S., Martewicz, S., Dupont, S., Floreani, A., & Elvassore, N. (2015) · Nature Methods · doi:10.1038/nmeth.3411 · Cited by 132
The quest for miniaturized soft bioelectronic devices
Kim, J., Ghaffari, R., & Kim, D. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0049 · Cited by 132
Self-citationSaavedra, W. F., Tunin, R. S., Paolocci, N., Mishima, T., Suzuki, G., Emala, C. W., Chaudhry, P. A., Anagnostopoulos, P. V., Gupta, R. C., Sabbah, H. N., et al. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)01890-9 · Cited by 130
Wireless Batteryless Implantable Blood Pressure Monitoring Microsystem for Small Laboratory Animals
Cong, P., Ko, W. H., & Young, D. J. (2010) · IEEE Sensors Journal · doi:10.1109/jsen.2009.2030982 · Cited by 127
Reverse Remodeling With Left Ventricular Assist Devices
Ambardekar, A. V., & Buttrick, P. M. (2011) · Circulation Heart Failure · doi:10.1161/circheartfailure.110.959684 · Cited by 127
Self-powered flexible inorganic electronic system
Lee, S. H., Jeong, C. K., Hwang, G., & Lee, K. J. (2014) · Nano Energy · doi:10.1016/j.nanoen.2014.12.003 · Cited by 126
Marginal donor grafts in heart transplantation: lessons learned from 25 years of experience
Wittwer, T., & Wahlers, T. (2007) · Transplant International · doi:10.1111/j.1432-2277.2007.00603.x · Cited by 121
Scaffold Vascularization: A Challenge for Three-Dimensional Tissue Engineering
Bramfeld, H., Sabra, G., Centis, V., & Vermette, P. (2010) · Current Medicinal Chemistry · doi:10.2174/092986710793205327 · Cited by 120
Epidermal Inorganic Optoelectronics for Blood Oxygen Measurement
Li, H., Xu, Y. F., Li, X., Chen, Y., Jiang, Y., Zhang, C., Lu, B., Wang, J., Ma, Y., Chen, Y., et al. (2017) · Advanced Healthcare Materials · doi:10.1002/adhm.201601013 · Cited by 118
Kim, S. B., Lee, K., Raj, M. S., Lee, B.-R., Reeder, J. T., Koo, J., Hourlier‐Fargette, A., Bandodkar, A. J., Won, S. M., Sekine, Y., et al. (2018) · Small · doi:10.1002/smll.201802876 · Cited by 118
Wearable Sensing Systems with Mechanically Soft Assemblies of Nanoscale Materials
Lee, Y., Kim, J., Joo, H., Raj, M. S., Ghaffari, R., & Kim, D. (2017) · Advanced Materials Technologies · doi:10.1002/admt.201700053 · Cited by 116
Self-citationA biodegradable hybrid inorganic nanoscaffold for advanced stem cell therapy
Yang, L., Chueng, S. D., Li, Y., Patel, M., Rathnam, C., Dey, G., Wang, L., Cai, L., & Lee, K. (2018) · Nature Communications · doi:10.1038/s41467-018-05599-2 · Cited by 116
Enabling Angioplasty‐Ready “Smart” Stents to Detect In‐Stent Restenosis and Occlusion
Chen, X., Assadsangabi, B., Hsiang, Y. N., & Takahata, K. (2018) · Advanced Science · doi:10.1002/advs.201700560 · Cited by 115
Bloom, H. L., Constantin, L., DAN, D., Lurgio, D. B. D., El‐Chami, M. F., Ganz, L. I., Gleed, K., Hackett, F. K., Kanuru, N. K., Lerner, D. J., et al. (2010) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2010.02931.x · Cited by 108
A Wireless Pressure Sensor Integrated with a Biodegradable Polymer Stent for Biomedical Applications
Park, J., Kim, J.-K., Patil, S. J., Park, J., Park, S., & Lee, D. (2016) · Sensors · doi:10.3390/s16060809 · Cited by 107
Flexible Blade‐Coated Multicolor Polymer Light‐Emitting Diodes for Optoelectronic Sensors
Han, D., Khan, Y., Ting, J., King, S. M., Yaacobi‐Gross, N., Humphries, M. J., Newsome, C. J., & Arias, A. C. (2017) · Advanced Materials · doi:10.1002/adma.201606206 · Cited by 106
Krishnan, S. R., Su, C., Xie, Z., Patel, M. J., Madhvapathy, S. R., Xu, Y., Freudman, J., Ng, B., Heo, S. Y., Wang, H., et al. (2018) · Small · doi:10.1002/smll.201803192 · Cited by 106
Overcoming the Roadblocks to Cardiac Cell Therapy Using Tissue Engineering
Yanamandala, M., Zhu, W., Garry, D. J., Kamp, T. J., Hare, J. M., Jun, H., Yoon, Y., Bursac, N., Prabhu, S. D., Dorn, G. W., et al. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.06.012 · Cited by 103
Nie, J., Qiao, B., Duan, S., Chen, X., Chen, B., Hao, W., Yu, B., Li, Y., Du, J., & Xu, F. (2018) · Advanced Materials · doi:10.1002/adma.201801570 · Cited by 101
Energetics of Blood Flow in Cardiovascular Disease
Rijnberg, F. M., Hazekamp, M. G., Wentzel, J. J., de Koning, P. J. H., Westenberg, J. J. M., Jongbloed, M. R. M., Blom, N. A., & Roest, A. A. W. (2018) · Circulation · doi:10.1161/circulationaha.117.033359 · Cited by 97
Flagged first, then by citations
1 of the 298 references couldn’t be matched to a known paper.
Research works printed but not linked: 15
- Jeong H., 2017, 39th Annu. Int. Conf. of IEEE Eng. Med. Biol. Soc.,
- Lonini L., 2017, Proc. 2017 ACM Int. Joint Conf. Pervasive and Ubiquitous Comput. and Proc. 2017 ACM Int. Symp. Wearable Comput.
- Webster J. G., 2009, Medical Instrumentation: Application and Design, 4th Edition
- Cong P., 2009, IEEE Int. Solid‐State Circuits Conf.
- Penaz J., 1973, Digest of the 10th Int. Conf. Med. Biol. Eng.
- Zhang H. L., 2014, Sci. World J., 2014, 404913
- Alraies M. C., 2014, J. Thorac. Dis., 6, 1120
- Reis Filho J. R., 2015, Arq. Bras. Cardiol., 104, 502
- Jhun C.‐S., 2010, Computational Cardiovascular Mechanics: Modelling and Applications in Heart Failure
- Roche E. T., 2015, Proc. ASME 2015 Int. Des. Eng. Tech. Conf. Comput. Inf. Eng. Conf.
- Horvath M. A., 2015, Proc. ASME 2015 Int. Des. Eng. Tech. Conf. Comput. Inf. Eng. Conf.
- Waksman R., 2016, Cirs.: Cardiovasc. Intervention, 9, e004150
- Jia H., 2018, Adv. Polym. Technol., 00, 1
- Park J., 2017, 19th Int. Conf. Solid‐State Sensors, Actuators and Microsystems
- 10.1038/nmat3404 · DOI · Paper page
Cited by
Sorted by citations
Wearable Pressure Sensors for Pulse Wave Monitoring
Meng, K., Xiao, X., Wei, W., Chen, G., Nashalian, A., Shen, S., Xiao, X., & Chen, J. (2022) · Advanced Materials · doi:10.1002/adma.202109357 · Cited by 900
Multifunctional materials for implantable and wearable photonic healthcare devices
Lee, G., Moon, H., Kim, H., Lee, G. H., Kwon, W., Yoo, S., Myung, D. J., Yun, S. H., Bao, Z., & Hahn, S. K. (2020) · Nature Reviews Materials · doi:10.1038/s41578-019-0167-3 · Cited by 683
Stretchable Electronics Based on PDMS Substrates
Qi, D., Zhang, K., Tian, G., Jiang, B., & Huang, Y. (2020) · Advanced Materials · doi:10.1002/adma.202003155 · Cited by 672
Zhang, L., Kumar, K. S., He, H., Cai, C. J., He, X., Gao, H., Yue, S., Li, C., Seet, R. C.-S., Ren, H., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-18503-8 · Cited by 574
Multifunctional conductive hydrogel-based flexible wearable sensors
Wang, L., Xu, T., & Zhang, X. (2021) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2020.116130 · Cited by 507
Metadata
- Authors
- Hong, Y. J., Jeong, H., Cho, K. W., Lu, N., & Kim, D.
- Affiliations
- Seoul National University (KR)
- The University of Texas at Austin (US)
- Corresponding author
- Lu, Nanshu
- Kim, Dae‐Hyeong
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2019-02-27
- Volume
- 29
- Issue
- 19
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2918664767
- Cited by
- 559
- References
- 298
- Citations by year
- 2026: 35 · 2025: 89 · 2024: 91 · 2023: 95 · 2022: 73 · 2021: 88 · 2020: 66 · 2019: 22
- FWCI
- 21.92
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- Advanced Functional Materials (publishedVersion)
- Seoul National University Open Repository (Seoul National University) (submittedVersion)
- Funders
- Office of Naval Research (N00014‐16‐1‐2044)
- National Research Foundation of Korea
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Keywords
- wearable devices, biomedical implants, flexible electronics, stretchable electronics, soft bioelectronics, cardiovascular monitoring, cardiac pacing, cardiac ablation, tissue engineering, in vitro cardiac models, electrocardiogram, blood pressure monitoring, oxygen saturation monitoring, cardiac repair
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review