The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Photopolymerization in Microfluidic Gradient Generators: Microscale Control of Substrate Compliance to Manipulate Cell Response
Abstract
Integration of a microfluidic gradient generator and photopolymerization to fabricate novel hydrogels with tunable mechanical properties on the microscale (see Figure) is reported. This concept introduces a new class of materials that can be used to investigate the role of substrate elastic moduli in controlling cell morphology and cytoskeletal organization, and more generally, cell behavior.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cell Movement Is Guided by the Rigidity of the Substrate
Lo, C.-M., Wang, H.-B., Dembo, M., & Wang, Y.-L. (2000) · Biophysical Journal · doi:10.1016/s0006-3495(00)76279-5 · Cited by 3,289
Cell locomotion and focal adhesions are regulated by substrate flexibility
Pelham, R. J., & Wang, Y.-L. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.25.13661 · Cited by 3,027
Functional hydrogel structures for autonomous flow control inside microfluidic channels
Beebe, D. J., Moore, J. S., Bauer, J. M., Yu, Q., Liu, R. H., Devadoss, C., & Jo, B.-H. (2000) · Nature · doi:10.1038/35007047 · Cited by 1,971
Extracellular Matrix Rigidity Causes Strengthening of Integrin–Cytoskeleton Linkages
Choquet, D., Felsenfeld, D. P., & Sheetz, M. P. (1997) · Cell · doi:10.1016/s0092-8674(00)81856-5 · Cited by 1,245
Substrate Compliance versus Ligand Density in Cell on Gel Responses
Engler, A., Bacakova, L., Newman, C., Hategan, A., Griffin, M., & Discher, D. (2004) · Biophysical Journal · doi:10.1016/s0006-3495(04)74140-5 · Cited by 1,141
Self-citationGeneration of Solution and Surface Gradients Using Microfluidic Systems
Jeon, N. L., Dertinger, S. K. W., Chiu, D. T., Choi, I. S., Stroock, A. D., & Whitesides, G. M. (2000) · Langmuir · doi:10.1021/la000600b · Cited by 963
Li Jeon, N., Baskaran, H., Dertinger, S. K. W., Whitesides, G. M., Van De Water, L., & Toner, M. (2002) · Nature Biotechnology · doi:10.1038/nbt712 · Cited by 917
Generation of Gradients Having Complex Shapes Using Microfluidic Networks
Dertinger, S. K. W., Chiu, D. T., Jeon, N. L., & Whitesides, G. M. (2001) · Analytical Chemistry · doi:10.1021/ac001132d · Cited by 839
Neurite branching on deformable substrates
Flanagan, L. A., Ju, Y.-E., Marg, B., Osterfield, M., & Janmey, P. A. (2002) · NeuroReport · doi:10.1097/00001756-200212200-00007 · Cited by 759
Anderson, J. R., Chiu, D. T., Jackman, R. J., Cherniavskaya, O., McDonald, J. C., Wu, H., Whitesides, S. H., & Whitesides, G. M. (2000) · Analytical Chemistry · doi:10.1021/ac9912294 · Cited by 698
Cited by
Tissue Cells Feel and Respond to the Stiffness of Their Substrate
Discher, D. E., Janmey, P., & Wang, Y.-L. (2005) · Science · doi:10.1126/science.1116995 · Cited by 6,382
Hydrogels in Biology and Medicine: From Molecular Principles to Bionanotechnology
Peppas, N. A., Hilt, J. Z., Khademhosseini, A., & Langer, R. (2006) · Advanced Materials · doi:10.1002/adma.200501612 · Cited by 4,109
Hydrogels in regenerative medicine
Slaughter, B. V., Khurshid, S. S., Fisher, O. Z., Khademhosseini, A., & Peppas, N. A. (2009) · Advanced Materials · doi:10.1002/adma.200802106 · Cited by 2,703
Microscale technologies for tissue engineering and biology
Khademhosseini, A., Langer, R., Borenstein, J., & Vacanti, J. P. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0507681102 · Cited by 1,558
Micro Total Analysis Systems. Latest Advancements and Trends
Dittrich, P. S., Tachikawa, K., & Manz, A. (2006) · Analytical Chemistry · doi:10.1021/ac0605602 · Cited by 950
Mesenchymal stem cell injection after myocardial infarction improves myocardial compliance
Berry, M. F., Engler, A. J., Woo, Y. J., Pirolli, T. J., Bish, L. T., Jayasankar, V., Morine, K. J., Gardner, T. J., Discher, D. E., & Sweeney, H. L. (2006) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01017.2005 · Cited by 690
Self-citationBiomolecular gradients in cell culture systems
Keenan, T. M., & Folch, A. (2008) · Lab Chip · doi:10.1039/b711887b · Cited by 596
Cell–Material Interactions Revealed Via Material Techniques of Surface Patterning
Yao, X., Peng, R., & Ding, J. (2013) · Advanced Materials · doi:10.1002/adma.201301762 · Cited by 501
Mechanical Properties of Cellularly Responsive Hydrogels and Their Experimental Determination
Kloxin, A. M., Kloxin, C. J., Bowman, C. N., & Anseth, K. S. (2010) · Advanced Materials · doi:10.1002/adma.200904179 · Cited by 481
Stiffness Gradients Mimicking In Vivo Tissue Variation Regulate Mesenchymal Stem Cell Fate
Tse, J. R., & Engler, A. J. (2011) · PLoS ONE · doi:10.1371/journal.pone.0015978 · Cited by 455
Self-citationMicroengineered Platforms for Cell Mechanobiology
Kim, D.-H., Wong, P. K., Park, J., Levchenko, A., & Sun, Y. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124915 · Cited by 411
In situ elasticity modulation with dynamic substrates to direct cell phenotype
Kloxin, A. M., Benton, J. A., & Anseth, K. S. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2009.09.025 · Cited by 408
Vascular Smooth Muscle Cell Durotaxis Depends on Substrate Stiffness Gradient Strength
Isenberg, B. C., DiMilla, P. A., Walker, M., Kim, S., & Wong, J. Y. (2009) · Biophysical Journal · doi:10.1016/j.bpj.2009.06.021 · Cited by 403
Self-citationBiological applications of microfluidic gradient devices
Kim, S., Kim, H. J., & Jeon, N. L. (2010) · Integrative Biology · doi:10.1039/c0ib00055h · Cited by 366
Self-citationMicrofluidic tools for cell biological research
Velve-Casquillas, G., Le Berre, M., Piel, M., & Tran, P. T. (2010) · Nano Today · doi:10.1016/j.nantod.2009.12.001 · Cited by 359
Physical Aspects of Cell Culture Substrates: Topography, Roughness, and Elasticity
Ross, A. M., Jiang, Z., Bastmeyer, M., & Lahann, J. (2012) · Small · doi:10.1002/smll.201100934 · Cited by 357
Surface-Bound Soft Matter Gradients
Genzer, J., & Bhat, R. R. (2008) · Langmuir · doi:10.1021/la7033164 · Cited by 343
Synthetic Materials in the Study of Cell Response to Substrate Rigidity
Nemir, S., & West, J. L. (2010) · Annals of Biomedical Engineering · doi:10.1007/s10439-009-9811-1 · Cited by 318
Organ-on-a-chip platforms: a convergence of advanced materials, cells, and microscale technologies
Ahadian, S., Civitarese, R., Bannerman, D., Mohammadi, M. H., Lu, R., Wang, E., Davenport‐Huyer, L., Lai, B., Zhang, B., Zhao, Y., et al. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700506 · Cited by 315
Quantifying cellular traction forces in three dimensions
Maskarinec, S. A., Franck, C., Tirrell, D. A., & Ravichandran, G. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0904565106 · Cited by 297
Nemir, S., Hayenga, H. N., & West, J. L. (2010) · Biotechnology and Bioengineering · doi:10.1002/bit.22574 · Cited by 282
Spatially controlled hydrogel mechanics to modulate stem cell interactions
Marklein, R. A., & Burdick, J. A. (2010) · Soft Matter · doi:10.1039/b916933d · Cited by 280
Biophysical Regulation of Cell Behavior—Cross Talk between Substrate Stiffness and Nanotopography
Yang, Y., Wang, K., Gu, X., & Leong, K. W. (2017) · Engineering · doi:10.1016/j.eng.2017.01.014 · Cited by 263
Substrates for cardiovascular tissue engineering
Bouten, C. V. C., Dankers, P. Y. W., Driessen-Mol, A., Pedron, S., Brizard, A. M. A., & Baaijens, F. P. T. (2011) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2011.01.007 · Cited by 261
Mesenchymal stem cell durotaxis depends on substrate stiffness gradient strength
Vincent, L. G., Choi, Y. S., Alonso‐Latorre, B., del Álamo, J. C., & Engler, A. J. (2013) · Biotechnology Journal · doi:10.1002/biot.201200205 · Cited by 257
Self-citationBiomimetic gradient hydrogels for tissue engineering
Sant, S., Hancock, M. J., Donnelly, J. P., Iyer, D., & Khademhosseini, A. (2010) · The Canadian Journal of Chemical Engineering · doi:10.1002/cjce.20411 · Cited by 253
Microfluidic 3D models of cancer
Sung, K. E., & Beebe, D. J. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.07.002 · Cited by 190
Understanding the extracellular forces that determine cell fate and maintenance
Kumar, A., Placone, J. K., & Engler, A. J. (2017) · Development · doi:10.1242/dev.158469 · Cited by 175
“Tissue stiffness also typically contains spatial gradients, which can be accomplished by changing gel thickness, crosslink density or micropost length in a spatially dependent manner (Hadden et al., 2017; Tse and Engler, 2011; Zaari et al., 2004).”
BackgroundSelf-citation
Metadata
- Authors
- Zaari, N., Rajagopalan, P., Kim, S. K., Engler, A. J., & Wong, J. Y.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2004-12-16
- Volume
- 16
- Issue
- 23-24
- Pages
- 2133-2137
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W2010846389
- Cited by
- 268
- References
- 20
- FWCI
- 3.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.