The DOI matches its Crossref record; 194 of the 194 references it cites were found in a registry or an index.
Microfluidic Chips for Point‐of‐Care Immunodiagnostics
Open accessAbstract
We might be at the turning point where research in microfluidics undertaken in academia and industrial research laboratories, and substantially sponsored by public grants, may provide a range of portable and networked diagnostic devices. In this Progress Report, an overview on microfluidic devices that may become the next generation of point‐of‐care (POC) diagnostics is provided. First, we describe gaps and opportunities in medical diagnostics and how microfluidics can address these gaps using the example of immunodiagnostics. Next, we conceptualize how different technologies are converging into working microfluidic POC diagnostics devices. Technologies are explained from the perspective of sample interaction with components of a device. Specifically, we detail materials, surface treatment, sample processing, microfluidic elements (such as valves, pumps, and mixers), receptors, and analytes in the light of various biosensing concepts. Finally, we discuss the integration of components into accurate and reliable devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Fluorescence Spectroscopy
(2006) · Springer eBooks · doi:10.1007/978-0-387-46312-4 · Cited by 19,339
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Loop-mediated isothermal amplification of DNA
Notomi, T. (2000) · Nucleic Acids Research · doi:10.1093/nar/28.12.e63 · Cited by 8,805
Self-Assembled Monolayers of Thiolates on Metals as a Form of Nanotechnology
Love, J. C., Estroff, L. A., Kriebel, J. K., Nuzzo, R. G., & Whitesides, G. M. (2005) · Chemical Reviews · doi:10.1021/cr0300789 · Cited by 8,282
Isolation of rare circulating tumour cells in cancer patients by microchip technology
Nagrath, S., Sequist, L. V., Maheswaran, S., Bell, D. W., Irimia, D., Ulkus, L., Smith, M. R., Kwak, E. L., Digumarthy, S., Muzikansky, A., et al. (2007) · Nature · doi:10.1038/nature06385 · Cited by 3,559
Chaotic Mixer for Microchannels
Stroock, A. D., Dertinger, S. K. W., Ajdari, A., Mezić, I., Stone, H. A., & Whitesides, G. M. (2002) · Science · doi:10.1126/science.1066238 · Cited by 3,435
Formation of monolayer films by the spontaneous assembly of organic thiols from solution onto gold
Bain, C. D., Troughton, E. B., Tao, Y. T., Evall, J., Whitesides, G. M., & Nuzzo, R. G. (1989) · Journal of the American Chemical Society · doi:10.1021/ja00183a049 · Cited by 3,393
Miniaturized total chemical analysis systems: A novel concept for chemical sensing
Manz, A., Graber, N., & Widmer, H. M. (1990) · Sensors and Actuators B: Chemical · doi:10.1016/0925-4005(90)80209-i · Cited by 3,122
Immunoassay of endogenous plasma insulin in man
Yalow, R. S., & Berson, S. A. (1960) · Journal of Clinical Investigation · doi:10.1172/jci104130 · Cited by 3,041
Hydrogen Ion Buffers for Biological Research*
Good, N. E., Winget, G. D., Winter, W., Connolly, T. N., Izawa, S., & Singh, R. M. M. (1966) · Biochemistry · doi:10.1021/bi00866a011 · Cited by 2,762
Cited by
Cancer biomarker detection: recent achievements and challenges
Wu, L., & Qu, X. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00370e · Cited by 1,214
Point of Care Diagnostics: Status and Future
Gubala, V., Harris, L. F., Ricco, A. J., Tan, M. X., & Williams, D. E. (2012) · Analytical Chemistry · doi:10.1021/ac2030199 · Cited by 1,194
Advances in Microfluidic Materials, Functions, Integration, and Applications
Nge, P. N., Rogers, C. I., & Woolley, A. T. (2013) · Chemical Reviews · doi:10.1021/cr300337x · Cited by 958
Turning the Page: Advancing Paper-Based Microfluidics for Broad Diagnostic Application
Gong, M. M., & Sinton, D. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00024 · Cited by 573
Point-of-care testing (POCT) diagnostic systems using microfluidic lab-on-a-chip technologies
Jung, W., Han, J., Choi, J.-W., & Ahn, C. H. (2015) · Microelectronic Engineering · doi:10.1016/j.mee.2014.09.024 · Cited by 510
Lab-on-a-chip devices: How to close and plug the lab?
Temiz, Y., Lovchik, R. D., Kaigala, G. V., & Delamarche, E. (2015) · Microelectronic Engineering · doi:10.1016/j.mee.2014.10.013 · Cited by 475
Self-citationAdvances in Plasmonic Technologies for Point of Care Applications
Tokel, O., Inci, F., & Demirci, U. (2014) · Chemical Reviews · doi:10.1021/cr4000623 · Cited by 407
Point-of-care microfluidic devices for pathogen detection
Nasseri, B., Soleimani, N., Rabiee, N., Kalbasi, A., Karimi, M., & Hamblin, M. R. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.05.050 · Cited by 382
Hang, Y., Boryczka, J., & Wu, N. (2022) · Chemical Society Reviews · doi:10.1039/c9cs00621d · Cited by 377
Yan, L., Zhu, Z., Zou, Y., Huang, Y., Liu, D., Jia, S., Xu, D., Wu, M., Zhou, Y., Zhou, S., et al. (2013) · Journal of the American Chemical Society · doi:10.1021/ja3114714 · Cited by 329
Industrial lab-on-a-chip: Design, applications and scale-up for drug discovery and delivery
Vladisavljević, G. T., Khalid, N., Neves, M. A., Kuroiwa, T., Nakajima, M., Uemura, K., Ichikawa, S., & Kobayashi, I. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.07.017 · Cited by 313
Li, S., Zhang, H., Zhu, M., Kuang, Z., Li, X., Xu, F., Miao, S., Zhang, Z., Lou, X., Li, H., et al. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00759 · Cited by 309
Mukama, O., Wu, J., Li, Z., Liang, Q., Yi, Z., Lu, X., Liu, Y., Liu, Y., Hussain, M., Makafe, G. G., et al. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112143 · Cited by 288
Nonspecific Binding—Fundamental Concepts and Consequences for Biosensing Applications
Frutiger, A., Tanno, A., Hwu, S., Tiefenauer, R. F., Vörös, J., & Nakatsuka, N. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00044 · Cited by 278
Nguyen, D. T., Meyers, C., Yee, T. D., Dudukovic, N. A., Destino, J. F., Zhu, C., Duoss, E. B., Baumann, T. F., Suratwala, T., Smay, J. E., et al. (2017) · Advanced Materials · doi:10.1002/adma.201701181 · Cited by 273
Chip in a lab: microfluidics for next generation life science research
Streets, A. M., & Huang, Y. (2013) · Biomicrofluidics · doi:10.1063/1.4789751 · Cited by 180
Lab-on-chip technology for chronic disease diagnosis
Wu, J., Dong, M., Rigatto, C., Liu, Y., & Lin, F. (2018) · npj Digital Medicine · doi:10.1038/s41746-017-0014-0 · Cited by 170
MEDICAL DEVICES EARLY ASSESSMENT METHODS: SYSTEMATIC LITERATURE REVIEW
Markiewicz, K., van Til, J. A., & IJzerman, M. J. (2014) · International Journal of Technology Assessment in Health Care · doi:10.1017/s0266462314000026 · Cited by 87
Advances in Candida detection platforms for clinical and point-of-care applications
Safavieh, M., Coarsey, C., Esiobu, N., Memic, A., Vyas, J. M., Shafiee, H., & Asghar, W. (2017) · Critical Reviews in Biotechnology · doi:10.3109/07388551.2016.1167667 · Cited by 57
Metadata
- Authors
- Gervais, L., de Rooij, N., & Delamarche, E.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2011-05-13
- Volume
- 23
- Issue
- 24
- Pages
- H151-76
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W2060764674
- Cited by
- 491
- References
- 194
- FWCI
- 25.16
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.