Microfluidic Chips for Point‐of‐Care Immunodiagnostics
Open accessAbstract
We might be at the turning point where research in microfluidics undertaken in academia and industrial research laboratories, and substantially sponsored by public grants, may provide a range of portable and networked diagnostic devices. In this Progress Report, an overview on microfluidic devices that may become the next generation of point‐of‐care (POC) diagnostics is provided. First, we describe gaps and opportunities in medical diagnostics and how microfluidics can address these gaps using the example of immunodiagnostics. Next, we conceptualize how different technologies are converging into working microfluidic POC diagnostics devices. Technologies are explained from the perspective of sample interaction with components of a device. Specifically, we detail materials, surface treatment, sample processing, microfluidic elements (such as valves, pumps, and mixers), receptors, and analytes in the light of various biosensing concepts. Finally, we discuss the integration of components into accurate and reliable devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Fluorescence Spectroscopy
(2006) · Springer eBooks · doi:10.1007/978-0-387-46312-4 · Cited by 19,339
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Loop-mediated isothermal amplification of DNA
Notomi, T. (2000) · Nucleic Acids Research · doi:10.1093/nar/28.12.e63 · Cited by 8,805
Self-Assembled Monolayers of Thiolates on Metals as a Form of Nanotechnology
Love, J. C., Estroff, L. A., Kriebel, J. K., Nuzzo, R. G., & Whitesides, G. M. (2005) · Chemical Reviews · doi:10.1021/cr0300789 · Cited by 8,282
Isolation of rare circulating tumour cells in cancer patients by microchip technology
Nagrath, S., Sequist, L. V., Maheswaran, S., Bell, D. W., Irimia, D., Ulkus, L., Smith, M. R., Kwak, E. L., Digumarthy, S., Muzikansky, A., et al. (2007) · Nature · doi:10.1038/nature06385 · Cited by 3,559
Chaotic Mixer for Microchannels
Stroock, A. D., Dertinger, S. K. W., Ajdari, A., Mezić, I., Stone, H. A., & Whitesides, G. M. (2002) · Science · doi:10.1126/science.1066238 · Cited by 3,435
Formation of monolayer films by the spontaneous assembly of organic thiols from solution onto gold
Bain, C. D., Troughton, E. B., Tao, Y. T., Evall, J., Whitesides, G. M., & Nuzzo, R. G. (1989) · Journal of the American Chemical Society · doi:10.1021/ja00183a049 · Cited by 3,393
Miniaturized total chemical analysis systems: A novel concept for chemical sensing
Manz, A., Graber, N., & Widmer, H. M. (1990) · Sensors and Actuators B: Chemical · doi:10.1016/0925-4005(90)80209-i · Cited by 3,122
Immunoassay of endogenous plasma insulin in man
Yalow, R. S., & Berson, S. A. (1960) · Journal of Clinical Investigation · doi:10.1172/jci104130 · Cited by 3,041
Hydrogen Ion Buffers for Biological Research*
Good, N. E., Winget, G. D., Winter, W., Connolly, T. N., Izawa, S., & Singh, R. M. M. (1966) · Biochemistry · doi:10.1021/bi00866a011 · Cited by 2,762
Diagnostics for the Developing World: Microfluidic Paper-Based Analytical Devices
Martinez, A. W., Phillips, S. T., Whitesides, G. M., & Carrilho, E. (2010) · Analytical Chemistry · doi:10.1021/ac9013989 · Cited by 2,674
Poly(dimethylsiloxane) as a Material for Fabricating Microfluidic Devices
McDonald, J. C., & Whitesides, G. M. (2002) · Accounts of Chemical Research · doi:10.1021/ar010110q · Cited by 2,454
Multiplexed electrical detection of cancer markers with nanowire sensor arrays
Zheng, G., Patolsky, F., Cui, Y., Wang, W. U., & Lieber, C. M. (2005) · Nature Biotechnology · doi:10.1038/nbt1138 · Cited by 2,436
Designing dendrimers for biological applications
Lee, C. C., MacKay, J. A., Fréchet, J. M. J., & Szoka, F. C. (2005) · Nature Biotechnology · doi:10.1038/nbt1171 · Cited by 2,043
New Approaches to Nanofabrication: Molding, Printing, and Other Techniques
Gates, B. D., Xu, Q., Stewart, M., Ryan, D., Willson, C. G., & Whitesides, G. M. (2005) · Chemical Reviews · doi:10.1021/cr030076o · Cited by 2,020
Functional hydrogel structures for autonomous flow control inside microfluidic channels
Beebe, D. J., Moore, J. S., Bauer, J. M., Yu, Q., Liu, R. H., Devadoss, C., & Jo, B.-H. (2000) · Nature · doi:10.1038/35007047 · Cited by 1,971
Engineered antibody fragments and the rise of single domains
Holliger, P., & Hudson, P. J. (2005) · Nature Biotechnology · doi:10.1038/nbt1142 · Cited by 1,931
Laser, D. J., & Santiago, J. G. (2004) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/14/6/r01 · Cited by 1,848
Self-Assembled Organic Monolayers: Model Systems for Studying Adsorption of Proteins at Aurfaces
Prime, K. L., & Whitesides, G. M. (1991) · Science · doi:10.1126/science.252.5009.1164 · Cited by 1,831
Micromachining a Miniaturized Capillary Electrophoresis-Based Chemical Analysis System on a Chip
Harrison, D. J., Fluri, K., Seiler, K., Fan, Z., Effenhauser, C. S., & Manz, A. (1993) · Science · doi:10.1126/science.261.5123.895 · Cited by 1,800
Barbey, R., Lavanant, L., Paripovic, D., Schüwer, N., Sugnaux, C., Tugulu, S., & Klok, H.-A. (2009) · Chemical Reviews · doi:10.1021/cr900045a · Cited by 1,753
Continuous inertial focusing, ordering, and separation of particles in microchannels
Di Carlo, D., Irimia, D., Tompkins, R. G., & Toner, M. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0704958104 · Cited by 1,708
Adaptive Recognition by Nucleic Acid Aptamers
Hermann, T., & Patel, D. J. (2000) · Science · doi:10.1126/science.287.5454.820 · Cited by 1,650
A new form of chromatogram employing two liquid phases
Martin, A. J. P., & Synge, R. L. M. (1941) · Biochemical Journal · doi:10.1042/bj0351358 · Cited by 1,631
A gas chromatographic air analyzer fabricated on a silicon wafer
Terry, S. C., Jerman, J. H., & Angell, J. B. (1979) · IEEE Transactions on Electron Devices · doi:10.1109/t-ed.1979.19791 · Cited by 1,452
Mutation detection and single-molecule counting using isothermal rolling-circle amplification
Lizardi, P. M., Huang, X., Zhu, Z., Bray-Ward, P., Thomas, D. C., & Ward, D. C. (1998) · Nature Genetics · doi:10.1038/898 · Cited by 1,442
Label-free immunodetection with CMOS-compatible semiconducting nanowires
Stern, E., Klemic, J. F., Routenberg, D. A., Wyrembak, P. N., Turner-Evans, D. B., Hamilton, A. D., LaVan, D. A., Fahmy, T. M., & Reed, M. A. (2007) · Nature · doi:10.1038/nature05498 · Cited by 1,352
Nucleic acid sequence-based amplification
Compton, J. (1991) · Nature · doi:10.1038/350091a0 · Cited by 1,344
Capillary electrophoresis and sample injection systems integrated on a planar glass chip
Harrison, D. J., Manz, A., Fan, Z., Luedi, H., & Widmer, H. M. (1992) · Analytical Chemistry · doi:10.1021/ac00041a030 · Cited by 1,226
Electrochemical Detection for Paper-Based Microfluidics
Dungchai, W., Chailapakul, O., & Henry, C. S. (2009) · Analytical Chemistry · doi:10.1021/ac9007573 · Cited by 1,224
Label-Free, Single-Molecule Detection with Optical Microcavities
Armani, A. M., Kulkarni, R. P., Fraser, S. E., Flagan, R. C., & Vahala, K. J. (2007) · Science · doi:10.1126/science.1145002 · Cited by 1,141
Pamme, N. (2006) · Lab Chip · doi:10.1039/b513005k · Cited by 1,129
A biosensor that uses ion-channel switches
Cornell, B. A., Braach-Maksvytis, V. L. B., King, L. G., Osman, P. D. J., Raguse, B., Wieczorek, L., & Pace, R. J. (1997) · Nature · doi:10.1038/42432 · Cited by 1,117
Point-of-Care Diagnostics for Global Health
Yager, P., Domingo, G. J., & Gerdes, J. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160524 · Cited by 1,076
T he D iagnostic A pplications of S aliva — A R eview
Kaufman, E., & Lamster, I. B. (2002) · Critical Reviews in Oral Biology & Medicine · doi:10.1177/154411130201300209 · Cited by 887
A microfabricated fluorescence-activated cell sorter
Fu, A. Y., Spence, C., Scherer, A., Arnold, F. H., & Quake, S. R. (1999) · Nature Biotechnology · doi:10.1038/15095 · Cited by 878
Helicase‐dependent isothermal DNA amplification
Vincent, M., Xu, Y., & Kong, H. (2004) · EMBO reports · doi:10.1038/sj.embor.7400200 · Cited by 877
Polymer microfabrication technologies for microfluidic systems
Becker, H., & Gärtner, C. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1692-2 · Cited by 860
The use of electrochemical impedance spectroscopy for biosensing
Lisdat, F., & Schäfer, D. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-1970-7 · Cited by 858
Applications of dip-pen nanolithography
Salaita, K., Wang, Y., & Mirkin, C. A. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2007.39 · Cited by 845
Oh, K. W., & Ahn, C. H. (2006) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/16/5/r01 · Cited by 838
Lab-on-a-chip devices for global health: Past studies and future opportunities
Chin, C. D., Linder, V., & Sia, S. K. (2007) · Lab Chip · doi:10.1039/b611455e · Cited by 811
Surface acoustic wave biosensors: a review
Länge, K., Rapp, B. E., & Rapp, M. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-1911-5 · Cited by 806
Towards integrated and sensitive surface plasmon resonance biosensors: A review of recent progress
Hoa, X. D., Kirk, A. G., & Tabrizian, M. (2007) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2007.07.001 · Cited by 790
Applications of Aptamers as Sensors
Cho, E. J., Lee, J.-W., & Ellington, A. D. (2009) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.112851 · Cited by 788
Microfluidic Large-Scale Integration: The Evolution of Design Rules for Biological Automation
Melin, J., & Quake, S. R. (2007) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.36.040306.132646 · Cited by 738
Microfluidic Digital PCR Enables Multigene Analysis of Individual Environmental Bacteria
Ottesen, E. A., Hong, J. W., Quake, S. R., & Leadbetter, J. R. (2006) · Science · doi:10.1126/science.1131370 · Cited by 737
Progress and Trends in Ink-jet Printing Technology
Le, H. P. (1998) · Journal of Imaging Science and Technology · doi:10.2352/j.imagingsci.technol.1998.42.1.art00007 · Cited by 720
Inertial microfluidics for continuous particle separation in spiral microchannels
Kuntaegowdanahalli, S. S., Bhagat, A. A. S., Kumar, G., & Papautsky, I. (2009) · Lab on a Chip · doi:10.1039/b908271a · Cited by 708
FLASH: A rapid method for prototyping paper-based microfluidic devices
Martinez, A. W., Phillips, S. T., Wiley, B. J., Gupta, M., & Whitesides, G. M. (2008) · Lab on a Chip · doi:10.1039/b811135a · Cited by 695
Engineering novel binding proteins from nonimmunoglobulin domains
Binz, H. K., Amstutz, P., & Plückthun, A. (2005) · Nature Biotechnology · doi:10.1038/nbt1127 · Cited by 676
Binding proteins selected from combinatorial libraries of an α-helical bacterial receptor domain
Nord, K., Gunneriusson, E., Ringdahl, J., Ståhl, S., Uhlén, M., & Nygren, P.-Å. (1997) · Nature Biotechnology · doi:10.1038/nbt0897-772 · Cited by 662
Label-Free Protein Biosensor Based on Aptamer-Modified Carbon Nanotube Field-Effect Transistors
Maehashi, K., Katsura, T., Kerman, K., Takamura, Y., Matsumoto, K., & Tamiya, E. (2007) · Analytical Chemistry · doi:10.1021/ac060830g · Cited by 660
Biomarkers in Acute Cardiac Disease
Jaffe, A. S., Babuin, L., & Apple, F. S. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.02.056 · Cited by 639
PCR microfluidic devices for DNA amplification
Zhang, C., Xu, J., Ma, W., & Zheng, W. (2006) · Biotechnology Advances · doi:10.1016/j.biotechadv.2005.10.002 · Cited by 634
Urinalysis: a comprehensive review.
Simerville, J. A., Maxted, W. C., & Pahira, J. J. (2005) · PubMed · Cited by 626
Toner, M., & Irimia, D. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.7.011205.135108 · Cited by 623
Deterministic hydrodynamics: Taking blood apart
Davis, J. A., Inglis, D. W., Morton, K. J., Lawrence, D. A., Huang, L. R., Chou, S. Y., Sturm, J. C., & Austin, R. H. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0605967103 · Cited by 622
Million-fold Preconcentration of Proteins and Peptides by Nanofluidic Filter
Wang, Y.-C., Stevens, A. L., & Han, J. (2005) · Analytical Chemistry · doi:10.1021/ac050321z · Cited by 618
ELECTROPHORESIS OF PROTEINS ON FILTER PAPER
Kunkel, H. G., & Tiselius, A. (1951) · Journal of General Physiology · doi:10.1085/jgp.35.1.89 · Cited by 617
Bonding of thermoplastic polymer microfluidics
Tsao, C.-W., & DeVoe, D. L. (2009) · Microfluidics and Nanofluidics · doi:10.1007/s10404-008-0361-x · Cited by 601
McKendry, R., Zhang, J., Arntz, Y., Strunz, T., Hegner, M., Lang, H. P., Baller, M. K., Certa, U., Meyer, E., Güntherodt, H.-J., et al. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.152330199 · Cited by 598
Abgrall, P., & Gué, A.-M. (2007) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/17/5/r01 · Cited by 561
Development of a digital microfluidic platform for point of care testing
Sista, R., Hua, Z., Thwar, P., Sudarsan, A., Srinivasan, V., Eckhardt, A., Pollack, M., & Pamula, V. (2008) · Lab on a Chip · doi:10.1039/b814922d · Cited by 550
Continuous particle separation in a microfluidic channel via standing surface acoustic waves (SSAW)
Shi, J., Huang, H., Stratton, Z., Huang, Y., & Huang, T. J. (2009) · Lab on a Chip · doi:10.1039/b915113c · Cited by 547
Guatelli, J. C., Whitfield, K. M., Kwoh, D. Y., Barringer, K. J., Richman, D. D., & Gingeras, T. R. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.5.1874 · Cited by 540
Fan, R., Vermesh, O., Srivastava, A., Yen, B. K. H., Qin, L., Ahmad, H., Kwong, G. A., Liu, C.-C., Gould, J., Hood, L., et al. (2008) · Nature Biotechnology · doi:10.1038/nbt.1507 · Cited by 539
Isothermal in vitro amplification of DNA by a restriction enzyme/DNA polymerase system.
Walker, G. T., Little, M. C., Nadeau, J. G., & Shank, D. D. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.1.392 · Cited by 539
Label-free detection of small-molecule–protein interactions by using nanowire nanosensors
Wang, W. U., Chen, C., Lin, K.-H., Fang, Y., & Lieber, C. M. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0406368102 · Cited by 534
Disposable Smart Lab on a Chip for Point-of-Care Clinical Diagnostics
Ahn, C. H., Choi, J.-W., Beaucage, G., Nevin, J., Lee, J.-B., Puntambekar, A., & Lee, R. J. Y. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820548 · Cited by 504
Verpoorte, E., & De Rooij, N. F. (2003) · Proceedings of the IEEE · doi:10.1109/jproc.2003.813570 · Cited by 503
Self-citationMudanyali, O., Tseng, D., Oh, C., Isikman, S. O., Sencan, I., Bishara, W., Oztoprak, C., Seo, S., Khademhosseini, B., & Ozcan, A. (2010) · Lab on a Chip · doi:10.1039/c000453g · Cited by 488
Disposable Microfluidic Devices: Fabrication, Function, and Application
Fiorini, G. S., & Chiu, D. T. (2005) · BioTechniques · doi:10.2144/05383rv02 · Cited by 487
Microfabricated Centrifugal Microfluidic Systems: Characterization and Multiple Enzymatic Assays
Duffy, D. C., Gillis, H. L., Lin, J., Sheppard, N. F., & Kellogg, G. J. (1999) · Analytical Chemistry · doi:10.1021/ac990682c · Cited by 478
Hydrogen ion buffers for biological research
Ferguson, W. J., Braunschweiger, K. I., Braunschweiger, W. R., Smith, J. R., McCormick, J. J., Wasmann, C. C., Jarvis, N. P., Bell, D. H., & Good, N. E. (1980) · Analytical Biochemistry · doi:10.1016/0003-2697(80)90079-2 · Cited by 465
Solvent-Resistant Photocurable “Liquid Teflon” for Microfluidic Device Fabrication
Rolland, J. P., Van Dam, R. M., Schorzman, D. A., Quake, S. R., & DeSimone, J. M. (2004) · Journal of the American Chemical Society · doi:10.1021/ja031657y · Cited by 440
The autofluorescence of plastic materials and chips measured under laser irradiation
Piruska, A., Nikcevic, I., Lee, S. H., Ahn, C., Heineman, W. R., Limbach, P. A., & Seliskar, C. J. (2005) · Lab on a Chip · doi:10.1039/b508288a · Cited by 431
A novel in-plane passive microfluidic mixer with modified Tesla structures
Hong, C.-C., Choi, J.-W., & Ahn, C. H. (2004) · Lab on a Chip · doi:10.1039/b305892a · Cited by 429
Autonomous Microfluidic Capillary System
Juncker, D., Schmid, H., Drechsler, U., Wolf, H., Wolf, M., Michel, B., de Rooij, N., & Delamarche, E. (2002) · Analytical Chemistry · doi:10.1021/ac0261449 · Cited by 426
Self-citationIntegrated Personal Health Records: Transformative Tools for Consumer-Centric Care
Detmer, D., Bloomrosen, M., Raymond, B., & Tang, P. (2008) · BMC Medical Informatics and Decision Making · doi:10.1186/1472-6947-8-45 · Cited by 420
An Integrated Fluorescence Detection System in Poly(dimethylsiloxane) for Microfluidic Applications
Chabinyc, M. L., Chiu, D. T., McDonald, J. C., Stroock, A. D., Christian, J. F., Karger, A. M., & Whitesides, G. M. (2001) · Analytical Chemistry · doi:10.1021/ac010423z · Cited by 419
Micropumps—past, progress and future prospects
WOIAS, P. (2005) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(04)00108-x · Cited by 411
Optical grating coupler biosensors
Vörös, J., Ramsden, J. J., Csúcs, G., Szendrő, I., De Paul, S. M., Textor, M., & Spencer, N. D. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00103-5 · Cited by 406
Gleghorn, J. P., Pratt, E. D., Denning, D., Liu, H., Bander, N. H., Tagawa, S. T., Nanus, D. M., Giannakakou, P. A., & Kirby, B. J. (2010) · Lab Chip · doi:10.1039/b917959c · Cited by 396
Microchip Device for Performing Enzyme Assays
Hadd, A. G., Raymond, D. E., Halliwell, J. W., Jacobson, S. C., & Ramsey, J. M. (1997) · Analytical Chemistry · doi:10.1021/ac970192p · Cited by 383
Matrix-insensitive protein assays push the limits of biosensors in medicine
Gaster, R. S., Hall, D. A., Nielsen, C. H., Osterfeld, S. J., Yu, H., Mach, K. E., Wilson, R. J., Murmann, B., Liao, J. C., Gambhir, S. S., et al. (2009) · Nature Medicine · doi:10.1038/nm.2032 · Cited by 382
Capillary pumps for autonomous capillary systems
Zimmermann, M., Schmid, H., Hunziker, P., & Delamarche, E. (2007) · Lab Chip · doi:10.1039/b609813d · Cited by 380
Self-citationMicropumps—past, progress and future prospects
Woias, P. (2005) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2004.02.033 · Cited by 371
Early Experiences with Personal Health Records
Halamka, J. D., Mandl, K. D., & Tang, P. C. (2008) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m2562 · Cited by 355
Open mHealth Architecture: An Engine for Health Care Innovation
Estrin, D., & Sim, I. (2010) · Science · doi:10.1126/science.1196187 · Cited by 351
Helical flows and chaotic mixing in curved micro channels
Jiang, F., Drese, K. S., Hardt, S., Küpper, M., & Schönfeld, F. (2004) · AIChE Journal · doi:10.1002/aic.10188 · Cited by 350
Generating Electrospray from Microchip Devices Using Electroosmotic Pumping
Ramsey, R. S., & Ramsey, J. M. (1997) · Analytical Chemistry · doi:10.1021/ac9610671 · Cited by 350
Gervais, L., & Delamarche, E. (2009) · Lab on a Chip · doi:10.1039/b906523g · Cited by 345
Self-citationImmunoassays in microfluidic systems
Ng, A. H. C., Uddayasankar, U., & Wheeler, A. R. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3678-8 · Cited by 345
Lutz, S., Weber, P., Focke, M., Faltin, B., Hoffmann, J., Müller, C., Mark, D., Roth, G., Munday, P., Armes, N., et al. (2010) · Lab on a Chip · doi:10.1039/b921140c · Cited by 344
Aptamer−Nanoparticle Strip Biosensor for Sensitive Detection of Cancer Cells
Liu, G., Mao, X., Phillips, J. A., Xu, H., Tan, W., & Zeng, L. (2009) · Analytical Chemistry · doi:10.1021/ac901889s · Cited by 340
Yakovleva, J., Davidsson, R., Lobanova, A., Bengtsson, M., Eremin, S., Laurell, T., & Emnéus, J. (2002) · Analytical Chemistry · doi:10.1021/ac015645b · Cited by 330
Cost-effective and compact wide-field fluorescent imaging on a cell-phone
Zhu, H., Yaglidere, O., Su, T.-W., Tseng, D., & Ozcan, A. (2011) · Lab Chip · doi:10.1039/c0lc00358a · Cited by 330
Protein microarrays with carbon nanotubes as multicolor Raman labels
Chen, Z., Tabakman, S. M., Goodwin, A. P., Kattah, M. G., Daranciang, D., Wang, X., Zhang, G., Li, X., Liu, Z., Utz, P. J., et al. (2008) · Nature Biotechnology · doi:10.1038/nbt.1501 · Cited by 322
Toward optimized antibody microarrays: a comparison of current microarray support materials
Angenendt, P., Glökler, J., Murphy, D., Lehrach, H., & Cahill, D. J. (2002) · Analytical Biochemistry · doi:10.1016/s0003-2697(02)00257-9 · Cited by 319
Microfluidic Platforms for Single-Cell Analysis
Zare, R. N., & Kim, S. (2010) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-070909-105238 · Cited by 318
A fully automated immunoassay from whole blood on a disc
Lee, B. S., Lee, J.-N., Park, J.-M., Lee, J.-G., Kim, S., Cho, Y.-K., & Ko, C. (2009) · Lab on a Chip · doi:10.1039/b820321k · Cited by 302
Fang, X., Liu, Y., Kong, J., & Jiang, X. (2010) · Analytical Chemistry · doi:10.1021/ac1000652 · Cited by 292
Selective isolation of live/dead cells using contactless dielectrophoresis (cDEP)
Shafiee, H., Sano, M. B., Henslee, E. A., Caldwell, J. L., & Davalos, R. V. (2010) · Lab on a Chip · doi:10.1039/b920590j · Cited by 288
Ultra Low Power Bioelectronics: Fundamentals, Biomedical Applications, and Bio-Inspired Systems
Sarpeshkar, R. (2010) · Cambridge University Press eBooks · doi:10.1017/cbo9780511841446 · Cited by 288
Hall, D. A., Ptacek, J., & Snyder, M. (2007) · Mechanisms of Ageing and Development · doi:10.1016/j.mad.2006.11.021 · Cited by 286
A mixed self-assembled monolayer-based surface plasmon immunosensor for detection of E. coli O157:H7
Subramanian, A., Irudayaraj, J., & Ryan, T. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2005.03.007 · Cited by 281
A facile route for irreversible bonding of plastic-PDMS hybrid microdevices at room temperature
Tang, L., & Lee, N. Y. (2010) · Lab on a Chip · doi:10.1039/b924753j · Cited by 267
Bartolo, D., Degré, G., Nghe, P., & Studer, V. (2008) · Lab Chip · doi:10.1039/b712368j · Cited by 265
A Quantitative Assessment of Heterogeneity for Surface-Immobilized Proteins
Vijayendran, R. A., & Leckband, D. E. (2001) · Analytical Chemistry · doi:10.1021/ac000523p · Cited by 260
Cardiac biomarkers and the case for point-of-care testing
McDonnell, B., Hearty, S., Leonard, P., & O'Kennedy, R. (2009) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2009.01.019 · Cited by 254
Grover, W. H., Ivester, R. H. C., Jensen, E. C., & Mathies, R. A. (2006) · Lab on a Chip · doi:10.1039/b518362f · Cited by 253
Stroke Biomarkers: Progress and Challenges for Diagnosis, Prognosis, Differentiation, and Treatment
Saenger, A. K., & Christenson, R. H. (2010) · Clinical Chemistry · doi:10.1373/clinchem.2009.133801 · Cited by 252
Microfluidics for Processing Surfaces and Miniaturizing Biological Assays
Delamarche, E., Juncker, D., & Schmid, H. (2005) · Advanced Materials · doi:10.1002/adma.200501129 · Cited by 251
Self-citationParticle Focusing Mechanisms in Curving Confined Flows
Gossett, D. R., & Carlo, D. D. (2009) · Analytical Chemistry · doi:10.1021/ac901306y · Cited by 246
Multipurpose microfluidic probe
Juncker, D., Schmid, H., & Delamarche, E. (2005) · Nature Materials · doi:10.1038/nmat1435 · Cited by 230
Self-citationLiu, J., & Lu, Y. (2006) · Angewandte Chemie · doi:10.1002/ange.200502589 · Cited by 227
Permeation-driven flow in poly(dimethylsiloxane) microfluidic devices.
Randall, G. C., & Doyle, P. S. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0503287102 · Cited by 220
Preconcentration of Proteins on Microfluidic Devices Using Porous Silica Membranes
Foote, R. S., Khandurina, J., Jacobson, S. C., & Ramsey, J. M. (2005) · Analytical Chemistry · doi:10.1021/ac049136w · Cited by 217
Huang, L., Reekmans, G., Saerens, D., Friedt, J.-M., Frederix, F., Francis, L., Muyldermans, S., Campitelli, A., & Hoof, C. V. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.11.016 · Cited by 215
Low-cost rapid prototyping of flexible microfluidic devices using a desktop digital craft cutter
Yuen, P. K., & Goral, V. N. (2010) · Lab Chip · doi:10.1039/b918089c · Cited by 212
Focus. Dealing with ‘real’ samples: sample pre-treatment in microfluidic systems
de Mello, A. J., & Beard, N. (2003) · Lab Chip · doi:10.1039/b301019h · Cited by 207
High-sensitivity miniaturized immunoassays for tumor necrosis factor ? using microfluidic systems
Cesaro-Tadic, S., Dernick, G., Juncker, D., Buurman, G., Kropshofer, H., Michel, B., Fattinger, C., & Delamarche, E. (2004) · Lab on a Chip · doi:10.1039/b408964b · Cited by 203
Self-citationTorque-Actuated Valves for Microfluidics
Weibel, D. B., Kruithof, M., Potenta, S., Sia, S. K., Lee, A., & Whitesides, G. M. (2005) · Analytical Chemistry · doi:10.1021/ac048303p · Cited by 197
Hucknall, A., Kim, D., Rangarajan, S., Hill, R. T., Reichert, W. M., & Chilkoti, A. (2009) · Advanced Materials · doi:10.1002/adma.200803125 · Cited by 185
Tsougeni, K., Papageorgiou, D., Tserepi, A., & Gogolides, E. (2010) · Lab Chip · doi:10.1039/b916566e · Cited by 179
Valves for autonomous capillary systems
Zimmermann, M. N., Hunziker, P., & Delamarche, E. (2008) · Microfluidics and Nanofluidics · doi:10.1007/s10404-007-0256-2 · Cited by 174
Self-citationLinder, V., Verpoorte, E., Thormann, W., de Rooij, N. F., & Sigrist, H. (2001) · Analytical Chemistry · doi:10.1021/ac010421e · Cited by 173
Self-citationA multiplexed optofluidic biomolecular sensor for low mass detection
Mandal, S., Goddard, J. M., & Erickson, D. (2009) · Lab on a Chip · doi:10.1039/b907826f · Cited by 159
Kaiser, J. (2010) · Science · doi:10.1126/science.327.5969.1072 · Cited by 159
Personally Controlled Online Health Data — The Next Big Thing in Medical Care?
Steinbrook, R. (2008) · New England Journal of Medicine · doi:10.1056/nejmp0801736 · Cited by 155
Magnetic hydrogel nanocomposites as remote controlled microfluidic valves
Satarkar, N. S., Zhang, W., Eitel, R. E., & Hilt, J. Z. (2009) · Lab on a Chip · doi:10.1039/b822694f · Cited by 152
Scaffolds for engineering novel binding sites in proteins
Nygren, P., & Uhlén, M. (1997) · Current Opinion in Structural Biology · doi:10.1016/s0959-440x(97)80108-x · Cited by 149
Single-Molecule DNA Amplification and Analysis Using Microfluidics
Zhang, C., & Xing, D. (2010) · Chemical Reviews · doi:10.1021/cr900081z · Cited by 148
Integrated microfluidic tmRNA purification and real-time NASBA device for molecular diagnostics
Dimov, I. K., Garcia-Cordero, J. L., O’Grady, J., Poulsen, C., Viguier, C., Kent, L., Daly, P., Lincoln, B., Maher, M., O’Kennedy, R. J., et al. (2008) · Lab on a Chip · doi:10.1039/b812515e · Cited by 144
Biologically Active Protein Nanoarrays Generated Using Parallel Dip‐Pen Nanolithography
Lee, S. W., Oh, B. ‐., Sanedrin, R. G., Salaita, K. S., Fujigaya, T., & Mirkin, C. A. (2006) · Advanced Materials · doi:10.1002/adma.200600070 · Cited by 143
Rapid detection of Bacillus anthracis using monoclonal antibody functionalized QCM sensor
Hao, R., Wang, D., Zhang, X., et al. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.07.071 · Cited by 139
Parallel microfluidic surface plasmon resonance imaging arrays
Ouellet, E., Lausted, C. G., Lin, T., Yang, C. W. T., Hood, L., & Lagally, E. T. (2010) · Lab on a Chip · doi:10.1039/b920589f · Cited by 135
Real-Time Nucleic Acid Sequence-Based Amplification in Nanoliter Volumes
Gulliksen, A., Solli, L., Karlsen, F., Rogne, H., Hovig, E. J., Nordstrøm, T., & Sirevåg, R. (2003) · Analytical Chemistry · doi:10.1021/ac034779h · Cited by 133
Silane–dextran chemistry on lateral flow polymer chips for immunoassays
Jönsson, C., Aronsson, M., Rundström, G., Pettersson, C., Mendel-Hartvig, I., Bakker, J. W. P., Martinsson, E., Liedberg, B., MacCraith, B. D., Öhman, O., et al. (2008) · Lab on a Chip · doi:10.1039/b800297e · Cited by 132
Liu, J., Pan, T., Woolley, A. T., & Lee, M. L. (2004) · Analytical Chemistry · doi:10.1021/ac040094l · Cited by 131
An electronically controlled piezoelectric insulin pump and valves
SPENCER, W. J., Corbett, W. T., Dominguez, L. R., & Shafer, B. D. (1978) · IEEE Transactions on Sonics and Ultrasonics · doi:10.1109/t-su.1978.31006 · Cited by 125
Teflon films for chemically-inert microfluidic valves and pumps
Grover, W. H., Muhlen, M. G. V., & Manalis, S. R. (2008) · Lab on a Chip · doi:10.1039/b800600h · Cited by 123
Facile Preparation of Complex Protein Architectures with Sub‐100‐nm Resolution on Surfaces
Coyer, S. R., Garcı́a, A. J., & Delamarche, E. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200700989 · Cited by 116
Self-citationSiegrist, J., Gorkin, R. A., III, Bastien, M., Stewart, G., Peytavi, R., Kido, H., Bergeron, M. G., & Madou, M. J. (2009) · Lab on a Chip · doi:10.1039/b913219h · Cited by 114
Electrochemical Detection of MicroRNAs via Gap Hybridization Assay
Pöhlmann, C., & Sprinzl, M. (2010) · Analytical Chemistry · doi:10.1021/ac100186p · Cited by 113
Sugiura, S., Szilágyi, A., Sumaru, K., Hattori, K., Takagi, T., Filipcsei, G., Zrı́nyi, M., & Kanamori, T. (2008) · Lab on a Chip · doi:10.1039/b810717c · Cited by 111
A Case Study of Personalized Medicine
Katsanis, S. H., Javitt, G. H., & Hudson, K. (2008) · Science · doi:10.1126/science.1156604 · Cited by 108
Diaz‐Quijada, G. A., Peytavi, R., Nantel, A., Roy, E., Bergeron, M. G., Dumoulin, M. M., & Veres, T. (2007) · Lab on a Chip · doi:10.1039/b700322f · Cited by 107
Rhee, M., & Burns, M. A. (2008) · Lab on a Chip · doi:10.1039/b805137b · Cited by 107
Fluid flow and convective heat transfer in flat microchannels
Mokrani, O., Bourouga, B., Castelain, C., & Peerhossaini, H. (2008) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2008.08.022 · Cited by 103
Incorporation of prefabricated screw, pneumatic, and solenoid valves into microfluidic devices
Hulme, S. E., Shevkoplyas, S. S., & Whitesides, G. M. (2008) · Lab on a Chip · doi:10.1039/b809673b · Cited by 102
Hataoka, Y., Zhang, L., Mori, Y., Tomita, N., Notomi, T., & Baba, Y. (2004) · Analytical Chemistry · doi:10.1021/ac035032u · Cited by 98
Performance Characteristics of Six Third-Generation Assays for Thyroid-Stimulating Hormone
Rawlins, M. L., & Roberts, W. L. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2004.039156 · Cited by 97
Greener, J., Li, W., Ren, J., Voicu, D., Pakharenko, V., Tang, T. J., & Kumacheva, E. (2009) · Lab on a Chip · doi:10.1039/b918834g · Cited by 96
Wei, F., Liao, W., Xu, Z., Yang, Y., Wong, D. T., & Ho, C. (2009) · Small · doi:10.1002/smll.200900369 · Cited by 96
A lab-on-a-chip for detection of nerve agent sarin in blood
Tan, H. Y., Loke, W. K., Tan, Y. T., & Nguyen, N. (2008) · Lab on a Chip · doi:10.1039/b800438b · Cited by 94
Wang, J., Ahmad, H. M. N., Ma, C., Shi, Q., Vermesh, O., Vermesh, U., & Heath, J. R. (2010) · Lab on a Chip · doi:10.1039/c0lc00132e · Cited by 93
Immuno-pillar chip: a new platform for rapid and easy-to-use immunoassay
Ikami, M., Kawakami, A., Kakuta, M., Okamoto, Y., Kaji, N., Tokeshi, M., & Baba, Y. (2010) · Lab on a Chip · doi:10.1039/c0lc00241k · Cited by 91
Surface modification of PDMS by gradient-induced migration of embedded Pluronic
Wu, Z., & Hjort, K. (2009) · Lab on a Chip · doi:10.1039/b901651a · Cited by 91
Uno, T., Tabata, H., & Kawai, T. (2006) · Analytical Chemistry · doi:10.1021/ac060273y · Cited by 89
Flexible fluidic microchips based on thermoformed and locally modified thin polymer films
Truckenmüller, R. K., Giselbrecht, S., van Blitterswijk, C., Dambrowsky, N., Gottwald, E., Mappes, T., Rolletschek, A., Saile, V., Trautmann, C., Weibezahn, K. F., et al. (2008) · Lab on a Chip · doi:10.1039/b803619e · Cited by 88
Continuous flow in open microfluidics using controlled evaporation
Zimmermann, M., Bentley, S., Schmid, H., Hunziker, P., & Delamarche, E. (2005) · Lab on a Chip · doi:10.1039/b510044e · Cited by 85
Self-citationClinical Chemistry: Challenges for Analytical Chemistry and the Nanosciences from Medicine
Durner, J. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200903363 · Cited by 85
Kim, A., Ah, C. S., Park, C. W., Yang, J., Kim, T., Ahn, C.-G., Park, S. H., & Sung, G. Y. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.12.026 · Cited by 84
Full On-Chip Nanoliter Immunoassay by Geometrical Magnetic Trapping of Nanoparticle Chains
Lacharme, F., Vandevyver, C. D. B., & Gijs, M. A. M. (2008) · Analytical Chemistry · doi:10.1021/ac7020739 · Cited by 77
Electronic control of elastomeric microfluidic circuits with shape memory actuators
Vyawahare, S., Sitaula, S., Martin, S., Adalian, D., & Scherer, A. (2008) · Lab on a Chip · doi:10.1039/b804515a · Cited by 76
Nanodroplet real-time PCR system with laser assisted heating
Kim, H., Dixit, S. S., Green, C. J., & Faris, G. W. (2008) · Optics Express · doi:10.1364/oe.17.000218 · Cited by 74
Label‐Free Detection of Protein–Protein Interactions on Biochips
Yeo, W., Min, D., Hsieh, R. W., Greene, G. L., & Mrksich, M. (2005) · Angewandte Chemie International Edition · doi:10.1002/anie.200501363 · Cited by 72
Rapid thermal lysis of cells using silicon–diamond microcantilever heaters
Privorotskaya, N. L., Liu, Y.-S., Lee, J., Zeng, H., Carlisle, J. A., Radadia, A. D., Millet, L. J., Bashir, R., & King, W. P. (2010) · Lab on a Chip · doi:10.1039/b923791g · Cited by 62
Polymer Microfluidic Chips with Integrated Waveguides for Reading Microarrays
Xu, F., Datta, P., Wang, H., Gurung, S., Hashimoto, M., Wei, S., Goettert, J. S., McCarley, R. L., & Soper, S. A. (2007) · Analytical Chemistry · doi:10.1021/ac7016597 · Cited by 54
Biomarkers for Cancer Risk, Early Detection, and Prognosis: The Validation Conundrum
Brenner, D. E., & Normolle, D. P. (2007) · Cancer Epidemiology Biomarkers & Prevention · doi:10.1158/1055-9965.epi-07-2619 · Cited by 52
Kim, S., Reidy, S. M., Block, B. P., Wise, K. D., Zellers, E. T., & Kurabayashi, K. (2010) · Lab on a Chip · doi:10.1039/c001390k · Cited by 51
Park, J., Kim, H., & Han, M.-G. (2010) · Chemical Society Reviews · doi:10.1039/b918135k · Cited by 50
Nanowire and nanotube transistors for lab-on-a-chip applications
Lee, M., Baik, K. Y., Noah, M. A., Kwon, Y., Lee, J.-O., & Hong, S. (2009) · Lab on a Chip · doi:10.1039/b905185f · Cited by 49
Brenner, H., Chang-Claude, J. C., Seiler, C. M., Stürmer, T., & Hoffmeister, M. (2007) · Cancer Epidemiology Biomarkers & Prevention · doi:10.1158/1055-9965.epi-06-0460 · Cited by 49
Monolithic Teflon® membrane valves and pumps for harsh chemical and low-temperature use
Willis, P. A., Hunt, B. D., White, V. E., Lee, M., Ikeda, M., Bae, S. Y., Pelletier, M. J., & Grunthaner, F. J. (2007) · Lab on a Chip · doi:10.1039/b707892g · Cited by 47
Comparison of Hydroxylated Print Additives on Antibody Microarray Performance
Wu, P., & Grainger, D. W. (2006) · Journal of Proteome Research · doi:10.1021/pr060217d · Cited by 46
Ghys, T., Goedhuys, W., Spincemaille, K., Gorus, F., & Gerlo, E. (2007) · Clinica Chimica Acta · doi:10.1016/j.cca.2007.07.025 · Cited by 42
Conditioning saliva for use in a microfluidic biosensor
Helton, K. L., Nelson, K. E., Fu, E. S., & Yager, P. (2008) · Lab on a Chip · doi:10.1039/b811150b · Cited by 41
Lee, B. Y., Seo, S. M., Lee, D. J., Lee, M., Lee, J., Cheon, J.-H., Cho, E., Lee, H., Chung, I.-Y., Park, Y. J., et al. (2010) · Lab on a Chip · doi:10.1039/b916975j · Cited by 41
A chip-to-chip nanoliter microfluidic dispenser
Wang, J., Zhou, Y., Qiu, H., Huang, H., Sun, C., Xi, J., & Huang, Y. (2009) · Lab on a Chip · doi:10.1039/b901635j · Cited by 37
A rapid prototyping method for polymer microfluidics with fixed aspect ratio and 3D tapered channels
Browne, A., Rust, M. J., Jung, W., et al. (2009) · Lab on a Chip · doi:10.1039/b903755a · Cited by 34
Development of a Point of Care Lateral Flow Device for Measuring Human Plasma Fibrinogen
Dudek, M. M., Lindahl, T. L., & Killard, A. J. (2010) · Analytical Chemistry · doi:10.1021/ac902763a · Cited by 34
Three-dimensional large-scale microfluidic integration by laser ablation of interlayer connections
Huft, J., Costa, D. J. D., Walker, D., & Hansen, C. L. (2010) · Lab on a Chip · doi:10.1039/c004051g · Cited by 34
Sebra, R., Anseth, K. S., & Bowman, C. N. (2006) · Journal of Polymer Science Part A Polymer Chemistry · doi:10.1002/pola.21247 · Cited by 33
An ISFET biosensor for the monitoring of maltose‐induced conformational changes in MBP
Park, H.-J., Kim, S. K., Park, K., Lyu, H., Lee, C., Chung, S. J., Yun, W. S., Kim, M., & Chung, B. H. (2008) · FEBS Letters · doi:10.1016/j.febslet.2008.11.039 · Cited by 30
Hands-free sample preparation platform for nucleic acid analysis
Baier, T., Hansen‐Hagge, T. E., Gransee, R., Crombé, A., Schmahl, S., Paulus, C., Drese, K. S., Keegan, H., Martin, C. M., O’Leary, J. J., et al. (2009) · Lab on a Chip · doi:10.1039/b910421f · Cited by 29
Willis, P. A., Greer, F., Lee, M., Smith, J. A., White, V. E., Grunthaner, F. J., Sprague, J. J., & Rolland, J. P. (2008) · Lab on a Chip · doi:10.1039/b804265a · Cited by 27
The Promise of Phage Display: Customized Affinity and Specificity
Weiss, G. A., & Penner, R. M. (2008) · Analytical Chemistry · doi:10.1021/ac086009h · Cited by 23
Potential of a simple lab-on-a-tube for point-of-care measurements of multiple analytes
Li, C., Shutter, L., Wu, P.-M., Ahn, C. H., & Narayan, R. K. (2010) · Lab on a Chip · doi:10.1039/c000897d · Cited by 23
Measurement of thermal properties of microfluidic samples using laser point heating thermometry
Choi, S. R., & Kim, D. (2006) · Thermochimica Acta · doi:10.1016/j.tca.2006.11.035 · Cited by 20
Elibol, O. H., Reddy, B., Nair, P. R., Dorvel, B. R., Butler, F., Ahsan, Z. S., Bergstrom, D. E., Alam, M. A., & Bashir, R. (2009) · Lab on a Chip · doi:10.1039/b906048k · Cited by 18
3D Ceramic Microfluidic Device Manufacturing
Natarajan, G., & Humenik, J. N. (2006) · Journal of Physics Conference Series · doi:10.1088/1742-6596/34/1/088 · Cited by 16
Cited by
Cancer biomarker detection: recent achievements and challenges
Wu, L., & Qu, X. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00370e · Cited by 1,214
Point of Care Diagnostics: Status and Future
Gubala, V., Harris, L. F., Ricco, A. J., Tan, M. X., & Williams, D. E. (2012) · Analytical Chemistry · doi:10.1021/ac2030199 · Cited by 1,194
Advances in Microfluidic Materials, Functions, Integration, and Applications
Nge, P. N., Rogers, C. I., & Woolley, A. T. (2013) · Chemical Reviews · doi:10.1021/cr300337x · Cited by 958
Turning the Page: Advancing Paper-Based Microfluidics for Broad Diagnostic Application
Gong, M. M., & Sinton, D. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00024 · Cited by 573
Point-of-care testing (POCT) diagnostic systems using microfluidic lab-on-a-chip technologies
Jung, W., Han, J., Choi, J.-W., & Ahn, C. H. (2015) · Microelectronic Engineering · doi:10.1016/j.mee.2014.09.024 · Cited by 510
Metadata
- Authors
- Gervais, L., de Rooij, N., & Delamarche, E.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2011-05-13
- Volume
- 23
- Issue
- 24
- Pages
- H151-76
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W2060764674
- Cited by
- 491
- References
- 194
- FWCI
- 25.16
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.