The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Flexible Organic Electrochemical Transistors for Highly Selective Enzyme Biosensors and Used for Saliva Testing
Abstract
Flexible organic electrochemical transistors (OECTs) are successfully used as high-performance enzyme biosensors, such as uric acid (UA) and cholesterol sensors. The sensitivity and selectivity of the sensors can be simultaneously enhanced by co-modifying the gate electrodes with positively/negatively charged bilayer polymer films and enzymes. These OECT-based UA sensors are successfully utilized for non-invasive UA detection in human saliva.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
State of Understanding of Nafion
Mauritz, K. A., & Moore, R. B. (2004) · Chemical Reviews · doi:10.1021/cr0207123 · Cited by 4,791
(1981) · Handbook of Exploration Geochemistry · doi:10.1016/b978-0-444-41930-9.50014-3 · Cited by 2,896
Hammock, M. L., Chortos, A., Tee, B. C. ‐., Tok, J. B. ‐., & Bao, Z. (2013) · Advanced Materials · doi:10.1002/adma.201302240 · Cited by 2,396
Ronkainen, N. J., Halsall, H. B., & Heineman, W. R. (2010) · Chemical Society Reviews · doi:10.1039/b714449k · Cited by 1,945
Biosensors: sense and sensibility
Turner, A. P. F. (2013) · Chemical Society Reviews · doi:10.1039/c3cs35528d · Cited by 1,654
Bergveld, P. (2003) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(02)00301-5 · Cited by 1,582
Recent advances in graphene-based biosensors
Kuila, T., Bose, S., Khanra, P., Mishra, A. K., Kim, N. H., & Lee, J. H. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.05.039 · Cited by 1,329
A Role for Uric Acid in the Progression of Renal Disease
Kang, D.-H., Nakagawa, T., Feng, L., Watanabe, S., Han, L., Mazzali, M., Truong, L., Harris, R., & Johnson, R. J. (2002) · Journal of the American Society of Nephrology · doi:10.1097/01.asn.0000034910.58454.fd · Cited by 1,304
Immobilization strategies to develop enzymatic biosensors
Sassolas, A., Blum, L. J., & Leca-Bouvier, B. D. (2012) · Biotechnology Advances · doi:10.1016/j.biotechadv.2011.09.003 · Cited by 1,130
A causal role for uric acid in fructose-induced metabolic syndrome
Nakagawa, T., Hu, H., Zharikov, S., Tuttle, K. R., Short, R. A., Glushakova, O., Ouyang, X., Feig, D. I., Block, E. R., Herrera-Acosta, J., et al. (2006) · American Journal of Physiology-Renal Physiology · doi:10.1152/ajprenal.00140.2005 · Cited by 1,104
In vivo recordings of brain activity using organic transistors
Khodagholy, D., Doublet, T., Quilichini, P., Gurfinkel, M., Leleux, P., Ghestem, A., Ismailova, E., Hervé, T., Sanaur, S., Bernard, C., et al. (2013) · Nature Communications · doi:10.1038/ncomms2573 · Cited by 1,012
Organic Thin‐Film Transistors for Chemical and Biological Sensing
Lin, P., & Yan, F. (2012) · Advanced Materials · doi:10.1002/adma.201103334 · Cited by 907
Self-citationHigh transconductance organic electrochemical transistors
Khodagholy, D., Rivnay, J., Sessolo, M., Gurfinkel, M., Leleux, P., Jimison, L. H., Stavrinidou, E., Herve, T., Sanaur, S., Owens, R. M., et al. (2013) · Nature Communications · doi:10.1038/ncomms3133 · Cited by 862
Saliva specimen: A new laboratory tool for diagnostic and basic investigation
Chiappin, S., Antonelli, G., Gatti, R., & De Palo, E. F. (2007) · Clinica Chimica Acta · doi:10.1016/j.cca.2007.04.011 · Cited by 828
Organic field-effect transistor sensors: a tutorial review
Torsi, L., Magliulo, M., Manoli, K., & Palazzo, G. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60127g · Cited by 825
Diagnostic Potential of Saliva: Current State and Future Applications
Pfaffe, T., Cooper-White, J., Beyerlein, P., Kostner, K., & Punyadeera, C. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2010.153767 · Cited by 798
White, H. S., Kittlesen, G. P., & Wrighton, M. S. (1984) · Journal of the American Chemical Society · doi:10.1021/ja00330a070 · Cited by 634
Berggren, M., & Richter‐Dahlfors, A. (2007) · Advanced Materials · doi:10.1002/adma.200700419 · Cited by 630
Graphene Oxide as a Matrix for Enzyme Immobilization
Zhang, J., Zhang, F., Yang, H., Huang, X., Liu, H., Zhang, J., & Guo, S. (2010) · Langmuir · doi:10.1021/la904014z · Cited by 541
Sun, C.-L., Lee, H.-H., Yang, J.-M., & Wu, C.-C. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.01.023 · Cited by 524
Yan, X., Chen, J., Yang, J., Xue, Q., & Miele, P. (2010) · ACS Applied Materials & Interfaces · doi:10.1021/am100293r · Cited by 493
A specific enzyme defect in gout associated with overproduction of uric acid.
Kelley, W. N., Rosenbloom, F. M., Henderson, J. F., & Seegmiller, J. E. (1967) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.57.6.1735 · Cited by 475
Knopfmacher, O., Hammock, M. L., Appleton, A. L., Schwartz, G., Mei, J., Lei, T., Pei, J., & Bao, Z. (2014) · Nature Communications · doi:10.1038/ncomms3954 · Cited by 415
Enzymatic sensing with organic electrochemical transistors
Bernards, D. A., Macaya, D. J., Nikolou, M., DeFranco, J. A., Takamatsu, S., & Malliaras, G. G. (2008) · J. Mater. Chem. · doi:10.1039/b713122d · Cited by 410
Direct Measurement of Ion Mobility in a Conducting Polymer
Stavrinidou, E., Leleux, P., Rajaona, H., Khodagholy, D., Rivnay, J., Lindau, M., Sanaur, S., & Malliaras, G. G. (2013) · Advanced Materials · doi:10.1002/adma.201301240 · Cited by 353
Lin, P., Luo, X., Hsing, I., & Yan, F. (2011) · Advanced Materials · doi:10.1002/adma.201102017 · Cited by 346
Self-citationCampana, A., Cramer, T., Simon, D. T., Berggren, M., & Biscarini, F. (2014) · Advanced Materials · doi:10.1002/adma.201400263 · Cited by 314
A Water‐Gate Organic Field‐Effect Transistor
Kergoat, L., Herlogsson, L., Braga, D., Piro, B., Pham, M., Crispin, X., Berggren, M., & Horowitz, G. (2010) · Advanced Materials · doi:10.1002/adma.200904163 · Cited by 310
Tang, H., Yan, F., Lin, P., Xu, J., & Chan, H. L. W. (2011) · Advanced Functional Materials · doi:10.1002/adfm.201002117 · Cited by 310
Self-citationEnzyme immobilization in novel alginate–chitosan core-shell microcapsules
Taqieddin, E., & Amiji, M. M. (2003) · Biomaterials · doi:10.1016/j.biomaterials.2003.08.034 · Cited by 307
Khodagholy, D., Curto, V. F., Fraser, K. J., Gurfinkel, M., Byrne, R., Diamond, D., Malliaras, G. G., Benito-Lopez, F., & Owens, R. M. (2012) · Journal of Materials Chemistry · doi:10.1039/c2jm15716k · Cited by 303
The Application of Organic Electrochemical Transistors in Cell‐Based Biosensors
Lin, P., Yan, F., Yu, J., Chan, H. L. W., & Yang, M. (2010) · Advanced Materials · doi:10.1002/adma.201000971 · Cited by 299
Self-citationCurrent development in non-invasive glucose monitoring
Ferrante do Amaral, C. E., & Wolf, B. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2007.06.003 · Cited by 269
Recent advances in cholesterol biosensor
Arya, S. K., Datta, M., & Malhotra, B. D. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2007.10.018 · Cited by 262
Highly sensitive dopamine biosensors based on organic electrochemical transistors
Tang, H., Lin, P., Chan, H. L. W., & Yan, F. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.05.025 · Cited by 244
Self-citationElectrochemical Detection of Uric Acid in Mixed and Clinical Samples: A Review
Lakshmi, D., Whitcombe, M. J., Davis, F., Sharma, P. S., & Prasad, B. B. (2011) · Electroanalysis · doi:10.1002/elan.201000525 · Cited by 237
Graphenes in chemical sensors and biosensors
Kochmann, S., Hirsch, T., & Wolfbeis, O. S. (2012) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2012.06.004 · Cited by 212
A review of enzymatic uric acid biosensors based on amperometric detection
Erden, P. E., & Kılıç, E. (2013) · Talanta · doi:10.1016/j.talanta.2013.01.043 · Cited by 210
Organic field-effect transistor for label-free dopamine sensing
Casalini, S., Leonardi, F., Cramer, T., & Biscarini, F. (2013) · Organic Electronics · doi:10.1016/j.orgel.2012.10.027 · Cited by 178
Organic Semiconductors in Organic Thin-Film Transistor-Based Chemical and Biological Sensors
Liao, C., & Yan, F. (2013) · Journal of macromolecular science. Part C, Reviews in macromolecular chemistry and physics/Journal of macromolecular science. Reviews in macromolecular chemistry and physics · doi:10.1080/15583724.2013.808665 · Cited by 161
Self-citationLiao, C., Zhang, M., Niu, L., Zheng, Z., & Yan, F. (2013) · Journal of Materials Chemistry B · doi:10.1039/c3tb21079k · Cited by 156
Self-citationNew opportunities for organic electronics and bioelectronics: ions in action
Tarabella, G., Mohammadi, F. M., Coppedé, N., Barbero, F., Iannotta, S., Santato, C., & Cicoira, F. (2012) · Chemical Science · doi:10.1039/c2sc21740f · Cited by 155
Polyaniline–uricase biosensor prepared with template process
Kan, J., Pan, X., & Chen, C. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2003.12.032 · Cited by 155
Salivary uric acid as a noninvasive biomarker of metabolic syndrome
Soukup, M., Biesiada, I., Henderson, A. T., Idowu, B., Rodeback, D., Ridpath, L. C., Bridges, E. G., Nazar, A. M., & Bridges, K. G. (2012) · Diabetology & Metabolic Syndrome · doi:10.1186/1758-5996-4-14 · Cited by 140
Ultralow Voltage, OTFT‐Based Sensor for Label‐Free DNA Detection
Lai, S., Demelas, M., Casula, G., Cosseddu, P., Barbaro, M., & Bonfiglió, A. (2012) · Advanced Materials · doi:10.1002/adma.201202996 · Cited by 131
Blicharz, T. M., Rissin, D. M., Bowden, M., Hayman, R. B., DiCesare, C. A., Bhatia, J. S., Grand-Pierre, N., Siqueira, W. L., Helmerhorst, E. J., Loscalzo, J., et al. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2008.105320 · Cited by 87
Yao, D., Vlessidis, A. G., & Evmiridis, N. P. (2003) · Analytica Chimica Acta · doi:10.1016/s0003-2670(02)01484-8 · Cited by 81
Ascorbic acid sensor based on ion-sensitive field-effect transistor modified with MnO2 nanoparticles
Luo, X., Xu, J., Zhao, W., & Chen, H. (2004) · Analytica Chimica Acta · doi:10.1016/j.aca.2004.02.039 · Cited by 75
Hammock, M. L., Knopfmacher, O., Ng, T. N., Tok, J. B. ‐., & Bao, Z. (2014) · Advanced Materials · doi:10.1002/adma.201401829 · Cited by 48
Cited by
Organic electrochemical transistors
Rivnay, J., Inal, S., Salleo, A., Owens, R. M., Berggren, M., & Malliaras, G. G. (2018) · Nature Reviews Materials · doi:10.1038/natrevmats.2017.86 · Cited by 2,065
PEDOT:PSS for Flexible and Stretchable Electronics: Modifications, Strategies, and Applications
Fan, X., Nie, W., Tsai, H., Wang, N., Huang, H., Cheng, Y., Wen, R., Ma, L., Yan, F., & Xia, Y. (2019) · Advanced Science · doi:10.1002/advs.201900813 · Cited by 1,028
Self-citationOrganic Photodetectors for Next‐Generation Wearable Electronics
Chow, P. C. Y., & Someya, T. (2020) · Advanced Materials · doi:10.1002/adma.201902045 · Cited by 779
Skin-Interfaced Wearable Sweat Sensors for Precision Medicine
Min, J., Tu, J., Xu, C., Lukas, H., Shin, S., Yang, Y., Solomon, S. A., Mukasa, D., & Gao, W. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00823 · Cited by 712
Endeavor of Iontronics: From Fundamentals to Applications of Ion‐Controlled Electronics
Bisri, S. Z., Shimizu, S., Nakano, M., & Iwasa, Y. (2017) · Advanced Materials · doi:10.1002/adma.201607054 · Cited by 558
Metadata
- Authors
- Liao, C., Mak, C., Zhang, M., Chan, H. L. W., & Yan, F.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2014-12-02
- Volume
- 27
- Issue
- 4
- Pages
- 676-681
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W2061967133
- Cited by
- 378
- References
- 49
- FWCI
- 9.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.