The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Localized Neuron Stimulation with Organic Electrochemical Transistors on Delaminating Depth Probes
Abstract
Organic electrochemical transistors are integrated on depth probes to achieve localized electrical stimulation of neurons. The probes feature a mechanical delamination process which leaves only a 4 μm thick film with embedded transistors inside the brain. This considerably reduces probe invasiveness and correspondingly improves future brain-machine interfaces.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
Sulforhodamine 101 as a specific marker of astroglia in the neocortex in vivo
Nimmerjahn, A., Kirchhoff, F., Kerr, J. N. D., & Helmchen, F. (2004) · Nature Methods · doi:10.1038/nmeth706 · Cited by 784
In Vitro and In Vivo Evaluation of PEDOT Microelectrodes for Neural Stimulation and Recording
Venkatraman, S., Hendricks, J., King, Z. A., Sereno, A. J., Richardson-Burns, S., Martin, D., & Carmena, J. M. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2109399 · Cited by 319
Self-generated theta oscillations in the hippocampus
Goutagny, R., Jackson, J., & Williams, S. (2009) · Nature Neuroscience · doi:10.1038/nn.2440 · Cited by 301
The density difference between tissue and neural probes is a key factor for glial scarring
Lind, G., Linsmeier, C. E., & Schouenborg, J. (2013) · Scientific Reports · doi:10.1038/srep02942 · Cited by 102
Cited by
Organic electrochemical transistors
Rivnay, J., Inal, S., Salleo, A., Owens, R. M., Berggren, M., & Malliaras, G. G. (2018) · Nature Reviews Materials · doi:10.1038/natrevmats.2017.86 · Cited by 2,065
Self-citationSoft and elastic hydrogel-based microelectronics for localized low-voltage neuromodulation
Liu, Y., Liu, J., Chen, S., Lei, T., Kim, Y., Niu, S., Wang, H., Wang, X., Foudeh, A. M., Tok, J. B.-H., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0335-6 · Cited by 811
Organic Bioelectronics: Bridging the Signaling Gap between Biology and Technology
Simon, D. T., Gabrielsson, E. O., Tybrandt, K., & Berggren, M. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00146 · Cited by 568
Polymer Semiconductors: Synthesis, Processing, and Applications
Ding, L., Yu, Z.-D., Wang, X.-Y., Yao, Z.-F., Lu, Y., Yang, C.-Y., Wang, J.-Y., & Pei, J. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00696 · Cited by 539
Next-generation probes, particles, and proteins for neural interfacing
Rivnay, J., Wang, H., Fenno, L., Deisseroth, K., & Malliaras, G. G. (2017) · Science Advances · doi:10.1126/sciadv.1601649 · Cited by 514
Self-citationOrganometal Halide Perovskite Artificial Synapses
Xu, W., Cho, H., Kim, Y., Kim, Y., Wolf, C., Park, C., & Lee, T. (2016) · Advanced Materials · doi:10.1002/adma.201506363 · Cited by 448
Electrolyte-gated transistors for enhanced performance bioelectronics
Torricelli, F., Adrahtas, D. Z., Bao, Z., Berggren, M., Biscarini, F., Bonfiglio, A., Bortolotti, C. A., Frisbie, C. D., Macchia, E., Malliaras, G. G., et al. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00065-8 · Cited by 422
Self-citationA guide for the characterization of organic electrochemical transistors and channel materials
Ohayon, D., Druet, V., & Inal, S. (2023) · Chemical Society Reviews · doi:10.1039/d2cs00920j · Cited by 350
Active Materials for Organic Electrochemical Transistors
Zeglio, E., & Inganäs, O. (2018) · Advanced Materials · doi:10.1002/adma.201800941 · Cited by 333
Kukhta, N. A., Marks, A., & Luscombe, C. K. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00266 · Cited by 309
Ling, H., Liu, S., Zheng, Z., & Yan, F. (2018) · Small Methods · doi:10.1002/smtd.201800070 · Cited by 289
Transparent, conformable, active multielectrode array using organic electrochemical transistors
Lee, W., Kim, D., Matsuhisa, N., Nagase, M., Sekino, M., Malliaras, G. G., Yokota, T., & Someya, T. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1703886114 · Cited by 254
Self-citationFlexible Electrochemical Biosensors for Health Monitoring
Yang, A., & Yan, F. (2021) · ACS Applied Electronic Materials · doi:10.1021/acsaelm.0c00534 · Cited by 122
The future of neuroscience: flexible and wireless implantable neural electronics
McGlynn, E., Nabaei, V., Ren, E., Galeote‐Checa, G., Das, R., Curia, G., & Heidari, H. (2021) · Advanced Science · doi:10.1002/advs.202002693 · Cited by 115
Conformable hybrid systems for implantable bioelectronic interfaces
Fallegger, F., Schiavone, G., & Lacour, S. P. (2020) · Advanced Materials · doi:10.1002/adma.201903904 · Cited by 113
Scalable batch fabrication of ultrathin flexible neural probes using a bioresorbable silk layer
Cointe, C., Laborde, A., Nowak, L. G., Arvanitis, D. N., Bourrier, D., Bergaud, C., & Maziz, A. (2022) · Microsystems & Nanoengineering · doi:10.1038/s41378-022-00353-7 · Cited by 78
Metadata
- Authors
- Williamson, A., Ferro, M., Leleux, P., Ismailova, E., Kaszas, A., Doublet, T., Quilichini, P., Rivnay, J., Rózsa, B., Katona, G., Bernard, C., & Malliaras, G. G.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2015-06-30
- Volume
- 27
- Issue
- 30
- Pages
- 4405-4410
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W2157789821
- Cited by
- 169
- References
- 5
- FWCI
- 5.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.