CoChat

Sensitive Wearable Temperature Sensor with Seamless Monolithic Integration

Open access

The DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.

Abstract

Accurate temperature field measurement provides critical information in many scientific problems. Herein, a new paradigm for highly sensitive, flexible, negative temperature coefficient (NTC) thermistor‐based artificial skin is reported, with the highest temperature sensing ability reported to date among previously reported NTC thermistors. This artificial skin is achieved through the development of a novel monolithic laser‐induced reductive sintering scheme and unique monolithic structures. The unique seamless monolithic structure simultaneously integrates two different components (a metal electrode and metal oxide sensing channel) from the same material at ambient pressure, which cannot be achieved by conventional heterogeneous integration through multiple, complex steps of photolithography or vacuum deposition. In addition to superior performance, electronic skin with high temperature sensitivity can be fabricated on heat‐sensitive polymer substrates due to the low‐temperature requirements of the process. As a proof of concept, temperature‐sensitive artificial skin is tested with conformally attachable physiological temperature sensor arrays in the measurement of the temperatures of exhaled breath for the early detection of pathogenic progression in the respiratory system. The proposed highly sensitive flexible temperature sensor and monolithic selective laser reductive sintering are expected to greatly contribute to the development of essential components in various emerging research fields, including soft robotics and healthcare systems.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/adma.201905527

Cites

51 of 51 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 51 references

Research works printed but not linked: 2

  1. Ryu J., 2009, J. Am. Chem. Soc., 92, 3084
  2. Mironova‐Ulmane N., 2011, Cent. Eur. J. Phys., 9, 1096

Cited by

See all 491

Metadata

Authors
Shin, J., Jeong, B., Kim, J., Nam, V. B., Yoon, Y., Jung, J., Hong, S., Lee, H., Eom, H., Yeo, J., Choi, J., Lee, D., & Ko, S. H.
Affiliations
  • Seoul National University (KR)
  • Gachon University (KR)
  • Hanyang University (KR)
  • Pusan National University (KR)
  • Korea Institute of Industrial Technology (KR)
  • Kyungpook National University (KR)
Corresponding author
  • Lee, Daeho
  • Ko, Seung Hwan
Venue
Advanced Materials
Publisher
Wiley
Published
2019-11-07
Volume
32
Issue
2
Pages
e1905527-e1905527
ISSN
  • 0935-9648 (ISSN-L)
  • 1521-4095
OpenAlex
W2989431324
Cited by
449
References
51
Citations by year
2026: 35 · 2025: 96 · 2024: 93 · 2023: 71 · 2022: 67 · 2021: 62 · 2020: 24 · 2019: 1
FWCI
13.55
Type
journal article
Language
en
Open access
Locations
  • Advanced Materials (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • Seoul National University Open Repository (Seoul National University) (submittedVersion)
Funders
National Research Foundation of Korea (2017R1A2B3005706, 2018R1D1A1B07042735)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrical and Thermal Properties of Materials
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Nanomaterials and Printing Technologies
Keywords
wearable temperature sensors, NTC thermistor, artificial skin, electronic skin, monolithic integration, respiratory disease detection, soft robotics
MeSH terms
Wearable Electronic Devices, Temperature, Skin, Artificial, Mechanical Phenomena

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.