Touch‐Based Stressless Cortisol Sensing
The DOI matches its Crossref record; 32 of the 33 references it cites were found in a registry or an index.
Abstract
Tracking fluctuations of the cortisol level is important in understanding the body's endocrine response to stress stimuli. Traditional cortisol sensing relies on centralized laboratory settings, while wearable cortisol sensors are limited to slow and complex assays. Here, a touch‐based non‐invasive molecularly imprinted polymer (MIP) electrochemical sensor for rapid, simple, and reliable stress‐free detection of sweat cortisol is described. The sensor readily measures fingertip sweat cortisol via highly selective binding to the cortisol‐imprinted electropolymerized polypyrrole coating. The MIP network is embedded with Prussian blue redox probes that offer direct electrical signaling of the binding event to realize sensitive label‐free amperometric detection. Using a highly permeable sweat‐wicking porous hydrogel, instantaneously secreted fingertip sweat can be conveniently and rapidly collected without any assistance. By eliminating time lags, such rapid (3.5 min) fingertip assay enables the capture of sharp variations in cortisol levels, compared to previous methods. Such advantages are demonstrated by tracking cortisol response in short cold‐pressor tests and throughout day‐long circadian rhythm, along with gold‐standard immunoassay validation. A stretchable epidermal MIP sensor is also described for directly tracking cortisol in exercise‐induced sweat. The rapid touch‐based cortisol sensor offers an attractive, accessible, stressless avenue for quantitative stress management.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In addition to monitoring patient fatigue, sweat sensing can also be used for psychological applications by monitoring the level of stress hormones such as cortisol and norepinephrine.[249,250]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [250]
Citations
Cites
Regulation of the Hypothalamic‐Pituitary‐Adrenocortical Stress Response
Herman, J. P., McKlveen, J. M., Ghosal, S., Kopp, B., Wulsin, A., Makinson, R., Scheimann, J., & Myers, B. (2016) · Comprehensive Physiology · doi:10.1002/cphy.c150015 · Cited by 1,819
Russell, G., & Lightman, S. (2019) · Nature Reviews Endocrinology · doi:10.1038/s41574-019-0228-0 · Cited by 1,032
HPA axis activation by a socially evaluated cold-pressor test
Schwabe, L., Haddad, L., & Schachinger, H. (2008) · Psychoneuroendocrinology · doi:10.1016/j.psyneuen.2008.03.001 · Cited by 696
Circadian rhythm disturbances in depression
Germain, A., & Kupfer, D. J. (2008) · Human Psychopharmacology: Clinical and Experimental · doi:10.1002/hup.964 · Cited by 644
Parlak, O., Keene, S. T., Marais, A., Curto, V. F., & Salleo, A. (2018) · Science Advances · doi:10.1126/sciadv.aar2904 · Cited by 603
Wearable sensors for monitoring the physiological and biochemical profile of the athlete
Seshadri, D. R., Li, R. T., Voos, J. E., Rowbottom, J. R., Alfes, C. M., Zorman, C. A., & Drummond, C. K. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0150-9 · Cited by 537
Taylor, N. A., & Machado-Moreira, C. A. (2013) · Extreme Physiology & Medicine · doi:10.1186/2046-7648-2-4 · Cited by 490
Technical and clinical aspects of cortisol as a biochemical marker of chronic stress
Lee, D. Y., Kim, E., & Choi, M. H. (2015) · BMB Reports · doi:10.5483/bmbrep.2015.48.4.275 · Cited by 484
Investigation of Cortisol Dynamics in Human Sweat Using a Graphene-Based Wireless mHealth System
Torrente-Rodríguez, R. M., Tu, J., Yang, Y., Min, J., Wang, M., Song, Y., Yu, Y., Xu, C., Ye, C., IsHak, W. W., et al. (2020) · Matter · doi:10.1016/j.matt.2020.01.021 · Cited by 479
Evaluation of a method to measure long term cortisol levels
Manenschijn, L., Koper, J. W., Lamberts, S. W. J., & van Rossum, E. F. C. (2011) · Steroids · doi:10.1016/j.steroids.2011.04.005 · Cited by 322
Research works printed but not linked: 1
- Porcelli A. J., 2014, J. Vis. Exp., 83, e50849
Cited by
Items 301–328 of 328
Smart wearable sensing systems mediating the digital monitoring of loneliness – A review
Mexia, N., Molteni, E., Ratcliffe, J., Probst, F., Matcham, F., Rees, J., Ourselin, S., Antonelli, M., Tinker, A., Liu, W., et al. (2026) · Materials Today Electronics · doi:10.1016/j.mtelec.2026.100202
Fan, H., Han, J., Sun, P., Ma, S., Dai, X., & Bu, Y. (2026) · ACS Applied Nano Materials · doi:10.1021/acsanm.5c05520
Özalp, Ö., & Soylak, M. (2026) · Journal of the Indian Chemical Society · doi:10.1016/j.jics.2026.102651
Emerging wearable sweat sensors for monitoring sports health
Wen, H., Huang, F., Gao, Z., Cao, Y., Liu, F., Li, A., Cai, W., Pan, T., & Liu, Q. (2026) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2026.118977
Wei, X., Hou, X., Zhang, H., Wang, H., Wang, L. Y., Cheng, H., & Yang, L. (2026) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6c05252
Gao, W., Zhang, C., Xu, H., Sun, X., Lu, X., Zhang, J., Zhou, W., Wei, K., Sun, H., Jing, W., et al. (2026) · ACS Sensors · doi:10.1021/acssensors.6c01677
Conductive hydrogel interfaces for flexible bioelectronics: Design, coupling, and applications
Liu, J., Chen, J., Zhang, H., Yuan, S., Huang, J., & Zhu, Y. (2026) · Green Technologies and Sustainability · doi:10.1016/j.grets.2026.100445
Flexible wood-derived hydrogel patch for smartphone-assisted interval sweat cortisol profiling
Chen, M., Shi, J., Zhang, S., 庄东青, Ren, Y., & Zhang, Y. (2026) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2026.119037
Touch-based wearable cortisol monitoring via an interface-engineered hydrogel fiber sensor
Tian, H., Qu, L., Chen, S., Shao, Z., Li, K., Zhang, Q., Li, Y., Wang, H. P., & Hou, C. (2026) · Talanta · doi:10.1016/j.talanta.2026.130339
Mun, T. J., Kim, K. Y., Choi, Y., Son, H., Cho, J., Kim, S., Kim, J., Lee, H., Seong, H., Ko, S. H., et al. (2026) · npj Flexible Electronics · doi:10.1038/s41528-026-00624-7
Park, M., Kim, S., & Ha, J. S. (2026) · Small · doi:10.1002/smll.75079
Zhou, Z., & Bian, Y. (2026) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/ae9647
Zhao, H., Zhang, X., Zameer, A., Xia, Y., Wang, J., Yu, D., Mugo, S. M., Serpe, M. J., Wang, H., Qu, W., et al. (2026) · Advanced Materials · doi:10.1002/adma.74688 · Cited by 1
Self-citationCell‐Like Portable Biologics‐Free Sensors for Stress Diagnostics
Pan, X., Liu, X., Liu, C., Fang, Y., Ong, W. L., Wang, X., & Ho, G. W. (2026) · Advanced Functional Materials · doi:10.1002/adfm.77967
Cao, C., Qu, X., Guo, Y., Wang, A., Shuai, Y., Wang, W., Wang, Q., Qu, L., & Dong, X. (2026) · Journal of the American Chemical Society · doi:10.1021/jacs.6c14649
Mahmud, A., Zhao, C., Uwakwe, C., Hsu, K., Choi, I. R., Chen, T., DeFelice, B. C., Gray, I. J., Hwang, J., Ilyn, D., et al. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.09.13.751286
Shkodra, B., Arslanova, K., Fellinger, E., Stimpel‐Lindner, T., Klenk, S., Hauk, S., Knirsch, K. C., Hirsch, A., Iljin, K., Nevanen, T. K., et al. (2026) · Small Science · doi:10.1002/smsc.70405
Nanostructured sensors and integrated systems for advanced biosensing
Shi, Y. (n.d.) · PolyU Institutional Research Archive (Hong Kong Polytechnic University)
Electrochemical Sensor Based on Laser-Induced Graphene for Cortisol Detection in Physiological Media
Zhang, S., Zhang, C., Zhang, J., Wang, Y., Sun, Y., Zhou, Y., & Zhao, F. (2026) · Biosensors · doi:10.3390/bios16100562
Wang, Y., Luan, L., Feng, R., Shi, M., Wang, L., & Zhang, X. (2026) · Green Technologies and Sustainability · doi:10.1016/j.grets.2026.100474
Gosti, C., Karrat, A., Özkan, S. A., Amine, A., & Arduini, F. (2026) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2026.119208
Liao, X., Yang, H., Lin, P., & Chen, S. (2026) · Materials Today Physics · doi:10.1016/j.mtphys.2026.102275
Yao, Y., Peng, Y., Song, K., Ma, Q., Yang, Z., & Jiang, Y. Y. (2026) · Analytica Chimica Acta · doi:10.1016/j.aca.2026.346383
Hui, M., Meng-Qi, H., Gong, Y., Huang, J., Fang, B., Guo, H., Ren, F., Liang, Q., & Ai, Y. (2026) · Journal of Pharmaceutical Analysis · doi:10.1016/j.jpha.2026.101819
Wang, Z., Xu, L., Xuehan, W., Li, W., & Niu, B. (2026) · Electrochimica Acta · doi:10.1016/j.electacta.2026.150353
Saikrithika, S., Theyagarajan, K., Yoon, S., & Kim, Y. (2026) · Chemosensors · doi:10.3390/chemosensors14110252
Foguel, M. V., dos Santos-Neto, S. M., Sena, S. C. D. S., de Oliveira, F. M. P. B., de França, Í. B., de Albuquerque, B. P. S., Costa, V., Lucena, M. A., Ferreira, M. E. D. M., Martelli, M. D. M., et al. (2026) · Sensors · doi:10.3390/s26217087
Li, F., Ma, Z., Gao, J., Zhang, L., Li, B., & He, J. (2026) · Chemical Engineering Science · doi:10.1016/j.ces.2026.125616
Metadata
- Authors
- Tang, W., Yin, L., Sempionatto, J. R., Moon, J., Teymourian, H., & Wang, J.
- Affiliations
- Shanghai Normal University (CN)
- University of California San Diego (US)
- Corresponding author
- Wang, Joseph
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2021-03-30
- Volume
- 33
- Issue
- 18
- Pages
- e2008465-e2008465
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W3145000295
- Cited by
- 302
- References
- 33
- Citations by year
- 2026: 48 · 2025: 79 · 2024: 61 · 2023: 53 · 2022: 44 · 2021: 17
- FWCI
- 12.87
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Advanced Materials (publishedVersion)
- PubMed (publishedVersion)
- Funders
- China Scholarship Council
- National Research Foundation of Korea (2019R1A6A3A12033345)
- Korea Research Institute of Chemical Technology
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
- Keywords
- molecularly imprinted polymers, electrochemical sensor, amperometric detection, wearable sensors, circadian rhythm, cold pressor test, stress management
- MeSH terms
- Wearable Electronic Devices, Molecularly Imprinted Polymers, Ferrocyanides, Fingers, Humans, Hydrocortisone, Polymers, Pyrroles, Sweat, Touch, Biosensing Techniques, Hydrogels, Electrochemical Techniques, Limit of Detection
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.