Physiologically Self‐Regulated, Fully Implantable, Battery‐Free System for Peripheral Nerve Restoration
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
The long‐segment peripheral nerve injury (PNI) represents a global medical challenge, leading to incomplete nerve tissue recovery and unsatisfactory functional reconstruction. However, the current electrical stimulation (ES) apparatuses fail perfect nerve repair due to their inability of the variable synchronous self‐regulated function with physiological states. It is urgent to develop an implantable ES platform with physiologically adaptive function to provide instantaneous and nerve‐preferred ES. Here, a physiologically self‐regulated electrical signal is generated by integrating a novel tribo/piezoelectric hybrid nanogenerator with a nanoporous nerve guide conduit to construct a fully implantable neural electrical stimulation (FI‐NES) system. The optimal neural ES parameters completely originate from the body itself and are highly self‐responsive to different physiological states. The morphological evaluation, representative protein expression level, and functional reconstruction of the regenerated nerves are conducted to assess the PNI recovery process. Evidence shows that the recovery effect of 15 mm length nerve defects under the guidance of the FI‐NES system is significantly close to the autograft. The designed FI‐NES system provides an effective method for long‐term accelerating the recovery of PNI in vivo and is also appropriate for other tissue injury or neurodegenerative diseases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
In Vivo Powering of Pacemaker by Breathing‐Driven Implanted Triboelectric Nanogenerator
Zheng, Q., Shi, B., Fan, F., Wang, X., Yan, L., Yuan, W., Wang, S., Liu, H., Li, Z., & Wang, Z. L. (2014) · Advanced Materials · doi:10.1002/adma.201402064 · Cited by 603
A Review of Organic and Inorganic Biomaterials for Neural Interfaces
Fattahi, P., Yang, G., Kim, G., & Abidian, M. R. (2014) · Advanced Materials · doi:10.1002/adma.201304496 · Cited by 580
Vijayavenkataraman, S. (2020) · Acta Biomaterialia · doi:10.1016/j.actbio.2020.02.003 · Cited by 556
Koo, J., MacEwan, M. R., Kang, S.-K., Won, S. M., Stephen, M., Gamble, P., Xie, Z., Yan, Y., Chen, Y.-Y., Shin, J., et al. (2018) · Nature Medicine · doi:10.1038/s41591-018-0196-2 · Cited by 496
In Vivo Self-Powered Wireless Cardiac Monitoring via Implantable Triboelectric Nanogenerator
Zheng, Q., Zhang, H., Shi, B., Xue, X., Liu, Z., Jin, Y., Ma, Y., Zou, Y., Wang, X., An, Z., et al. (2016) · ACS Nano · doi:10.1021/acsnano.6b02693 · Cited by 449
Piech, D. K., Johnson, B. C., Shen, K., Ghanbari, M. M., Li, K. Y., Neely, R. M., Kay, J. E., Carmena, J. M., Maharbiz, M. M., & Muller, R. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0518-9 · Cited by 442
Muscle‐Driven In Vivo Nanogenerator
Li, Z., Zhu, G., Yang, R., Wang, A. C., & Wang, Z. L. (2010) · Advanced Materials · doi:10.1002/adma.200904355 · Cited by 441
Contributions of Different Functional Groups to Contact Electrification of Polymers
Li, S., Nie, J., Shi, Y., Tao, X., Wang, F., Tian, J., Lin, S., Chen, X., & Wang, Z. L. (2020) · Advanced Materials · doi:10.1002/adma.202001307 · Cited by 419
Ma, Y., Zheng, Q., Liu, Y., Shi, B., Xue, X., Ji, W., Liu, Z., Jin, Y., Zou, Y., An, Z., et al. (2016) · Nano Letters · doi:10.1021/acs.nanolett.6b01968 · Cited by 367
Self-powered cardiovascular electronic devices and systems
Zheng, Q., Tang, Q., Wang, Z. L., & Li, Z. (2021) · Nature Reviews Cardiology · doi:10.1038/s41569-020-0426-4 · Cited by 348
Transcatheter Self‐Powered Ultrasensitive Endocardial Pressure Sensor
Liu, Z., Ma, Y., Ouyang, H., Shi, B., Li, N., Jiang, D., Xie, F., Qu, D., Zou, Y., Huang, Y., et al. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201807560 · Cited by 308
Review of recent advances in peripheral nerve stimulation (PNS)
Chakravarthy, K., Nava, A., Christo, P. J., & Williams, K. (2016) · Current Pain and Headache Reports · doi:10.1007/s11916-016-0590-8 · Cited by 136
Cited by
Advanced Energy Harvesters and Energy Storage for Powering Wearable and Implantable Medical Devices
Gao, Z., Zhou, Y., Zhang, J., Foroughi, J., Peng, S., Baughman, R. H., Wang, Z. L., & Wang, C. H. (2024) · Advanced Materials · doi:10.1002/adma.202404492 · Cited by 231
Chen, P., Xu, C., Wu, P., Liu, K., Chen, F., Chen, Y., Dai, H., & Luo, Z. (2022) · ACS Nano · doi:10.1021/acsnano.2c05818 · Cited by 228
Wu, P., Chen, P., Xu, C., Wang, Q., Zhang, F., Yang, K., Jiang, W., Feng, J., & Luo, Z. (2022) · Nano Energy · doi:10.1016/j.nanoen.2022.107707 · Cited by 190
Electrospun Fibers Control Drug Delivery for Tissue Regeneration and Cancer Therapy
Li, L., Hao, R., Qin, J., Song, J., Chen, X., Rao, F., Zhai, J., Zhao, Y., Zhang, L., & Xue, J. (2022) · Advanced Fiber Materials · doi:10.1007/s42765-022-00198-9 · Cited by 168
Self-citationFang, Y., Wang, C., Liu, Z., Ko, J., Chen, L., Zhang, T., Xiong, Z., Zhang, L., & Sun, W. (2023) · Advanced Science · doi:10.1002/advs.202205744 · Cited by 165
Metadata
- Authors
- Jin, F., Li, T., Yuan, T., Du, L., Lai, C., Wu, Q., Zhao, Y., Sun, F., Gu, L., Wang, T., & Feng, Z.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2021-10-04
- Volume
- 33
- Issue
- 48
- Pages
- e2104175-e2104175
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W3204915404
- Cited by
- 136
- References
- 12
- FWCI
- 8.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.