Piezoelectric Dynamics of Arterial Pulse for Wearable Continuous Blood Pressure Monitoring
Abstract
Piezoelectric arterial pulse wave dynamics are traditionally considered to be similar to those of typical blood pressure waves. However, achieving accurate continuous blood pressure wave monitoring based on arterial pulse waves remains challenging, because the correlation between piezoelectric pulse waves and their related blood pressure waves is unclear. To address this, the correlation between piezoelectric pulse waves and blood pressure waves is first elucidated via theoretical, simulation, and experimental analysis of these dynamics. Based on this correlation, the authors develop a wireless wearable continuous blood pressure monitoring system, with better portability than conventional systems that are based on the pulse wave velocity between multiple sensors. They explore the feasibility of achieving wearable continuous blood pressure monitoring without motion artifacts, using a single piezoelectric sensor. These findings eliminate the controversy over the arterial pulse wave piezoelectric response, and can potentially be used to develop a portable wearable continuous blood pressure monitoring device for the early prevention and daily control of hypertension.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dagdeviren, C., Su, Y., Joe, P., Yona, R., Liu, Y., Kim, Y.-S., Huang, Y., Damadoran, A. R., Xia, J., Martin, L. W., et al. (2014) · Nature Communications · doi:10.1038/ncomms5496 · Cited by 987
Monitoring of the central blood pressure waveform via a conformal ultrasonic device
Wang, C., Li, X., Hu, H., Zhang, L., Huang, Z., Lin, M., Zhang, Z., Yin, Z., Huang, B., Gong, H., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0287-x · Cited by 895
Biodegradable and flexible arterial-pulse sensor for the wireless monitoring of blood flow
Boutry, C. M., Beker, L., Kaizawa, Y., Vassos, C., Tran, H., Hinckley, A. C., Pfattner, R., Niu, S., Li, J., Claverie, J., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0336-5 · Cited by 862
Self‐Powered Real‐Time Arterial Pulse Monitoring Using Ultrathin Epidermal Piezoelectric Sensors
Park, D. Y., Joe, D. J., Kim, D. H., Park, H., Han, J. H., Jeong, C. K., Park, H., Park, J. G., Joung, B., & Lee, K. J. (2017) · Advanced Materials · doi:10.1002/adma.201702308 · Cited by 691
Cuffless Blood Pressure Estimation Algorithms for Continuous Health-Care Monitoring
Kachuee, M., Kiani, M. M., Mohammadzade, H., & Shabany, M. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2580904 · Cited by 621
Ershad, F., Thukral, A., Yue, J., Comeaux, P., Lu, Y., Shim, H., Sim, K., Kim, N.-I., Rao, Z., Guevara, R., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-17619-1 · Cited by 355
Avolio, A. P., Butlin, M., & Walsh, A. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/1/r01 · Cited by 310
Relation between blood pressure and pulse wave velocity for human arteries
Ma, Y., Choi, J., Hourlier-Fargette, A., Xue, Y., Chung, H. U., Lee, J. Y., Wang, X., Xie, Z., Kang, D., Wang, H., et al. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1814392115 · Cited by 309
Peter, L., Noury, N., & Cerny, M. (2014) · IRBM · doi:10.1016/j.irbm.2014.07.002 · Cited by 261
Cuff-Less and Continuous Blood Pressure Monitoring: A Methodological Review
Sharma, M., Barbosa, K., Ho, V., Griggs, D., Ghirmai, T., Krishnan, S., Hsiai, T., Chiao, J.-C., & Cao, H. (2017) · Technologies · doi:10.3390/technologies5020021 · Cited by 226
Direct Powering a Real Cardiac Pacemaker by Natural Energy of a Heartbeat
Li, N., Yi, Z., Ma, Y., Xie, F., Huang, Y., Tian, Y., Dong, X., Liu, Y., Shao, X., Li, Y., et al. (2019) · ACS Nano · doi:10.1021/acsnano.8b08567 · Cited by 198
Self-citationZhu, H., Liu, A., Luque, H. L., Sun, H., Ji, D., & Noh, Y.-Y. (2019) · ACS Nano · doi:10.1021/acsnano.8b07567 · Cited by 197
Monitoring Arterial Blood Pressure: What You May Not Know
McGhee, B. H., & Bridges, E. J. (2002) · Critical Care Nurse · doi:10.4037/ccn2002.22.2.60 · Cited by 189
Petritz, A., Karner-Petritz, E., Uemura, T., Schäffner, P., Araki, T., Stadlober, B., & Sekitani, T. (2021) · Nature Communications · doi:10.1038/s41467-021-22663-6 · Cited by 183
Ding, X.-R., Zhao, N., Yang, G.-Z., Pettigrew, R. I., Lo, B., Miao, F., Li, Y., Liu, J., & Zhang, Y.-T. (2016) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2016.2620995 · Cited by 181
Self-citationLi, H., Ma, Y., Liang, Z., Wang, Z., Cao, Y. K., Xu, Y., Zhou, H., Lu, B., Chen, Y., Han, Z., et al. (2020) · National Science Review · doi:10.1093/nsr/nwaa022 · Cited by 144
Ding, X., & Zhang, Y. (2019) · Biomedical Engineering Letters · doi:10.1007/s13534-019-00096-x · Cited by 142
Standardization of blood pressure measurement in an international comparative study
Ataman, S. L., Cooper, R., Rotimi, C. N., McGee, D., Osotimehin, B., Kadiri, S., Kingué, S., Muna, W. F. T., Fraser, H. S., Forrester, T., et al. (1996) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(96)00111-4 · Cited by 114
A Technical Assessment of Pulse Wave Velocity Algorithms Applied to Non-invasive Arterial Waveforms
Gaddum, N. R., Alastruey, J., Beerbaum, P., Chowienczyk, P., & Schaeffter, T. (2013) · Annals of Biomedical Engineering · doi:10.1007/s10439-013-0854-y · Cited by 110
JCS Joint Working Group (2012) · Circulation Journal · doi:10.1253/circj.cj-88-0020 · Cited by 105
A Non-Invasive Continuous Blood Pressure Estimation Approach Based on Machine Learning
Chen, S., Ji, Z., Wu, H., & Xu, Y. (2019) · Sensors · doi:10.3390/s19112585 · Cited by 103
Cuffless Blood Pressure Monitoring: Promises and Challenges
Pandit, J. A., Lores, E., & Batlle, D. (2020) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.03680320 · Cited by 101
Chen, J., Liu, H., Wang, W., Nabulsi, N., Zhao, W., Kim, J. Y., Kwon, M., & Ryou, J. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201903162 · Cited by 99
Rastegar, S., GholamHosseini, H., & Lowe, A. (2019) · Physical and Engineering Sciences in Medicine · doi:10.1007/s13246-019-00813-x · Cited by 89
Yi, Z., Yang, B. T., Li, G., Liu, J., Chen, X., Wang, X., & Yang, C. (2017) · Applied Physics Letters · doi:10.1063/1.4991368 · Cited by 86
Self-citationWearable Piezoelectric-Based System for Continuous Beat-to-Beat Blood Pressure Measurement
Wang, T.-W., & Lin, S. (2020) · Sensors · doi:10.3390/s20030851 · Cited by 77
A Battery‐ and Leadless Heart‐Worn Pacemaker Strategy
Yi, Z., Xie, F., Tian, Y., Li, N., Dong, X., Ma, Y., Huang, Y., Hu, Y., Xu, X., Qu, D., et al. (2020) · Advanced Functional Materials · doi:10.1002/adfm.202000477 · Cited by 73
Self-citationAl‐Qatatsheh, A., Morsi, Y., Zavabeti, A., Zolfagharian, A., Salim, N. V., Kouzani, A. Z., Mosadegh, B., & Gharaie, S. (2020) · Sensors · doi:10.3390/s20164484 · Cited by 71
Huttunen, J. M. J., Kärkkäinen, L., & Lindholm, H. J. (2019) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1007259 · Cited by 55
Wang, H., Wang, L., Sun, N., Yao, Y., Hao, L., Xu, L., & Greenwald, S. E. (2020) · Frontiers in Physiology · doi:10.3389/fphys.2019.01563 · Cited by 41
Self-Powered Force Sensor Based on Thinned Bulk PZT for Real-Time Cutaneous Activities Monitoring
Yi, Z., Yang, H.-J., Tian, Y., Dong, X., Liu, J., & Yang, B. T. (2018) · IEEE Electron Device Letters · doi:10.1109/led.2018.2846184 · Cited by 36
Self-citationYi, Z., Huang, J., Liu, Z., Liu, J., & Yang, B. T. (2019) · IEEE Electron Device Letters · doi:10.1109/led.2019.2954878 · Cited by 35
Self-citation5H-2 A Piezoelectric Membrane Sensor for Biomedical Monitoring
Ono, Y., Liu, Q., Kobayashi, M., Jen, C. K., & Blouin, A. (2006) · Proceedings/Proceedings - IEEE Ultrasonics Symposium · doi:10.1109/ultsym.2006.164 · Cited by 19
Commentary: Relation Between Blood Pressure and Pulse Wave Velocity for Human Arteries
Yavarimanesh, M., Chandrasekhar, A., Hahn, J., & Mukkamala, R. (2019) · Frontiers in Physiology · doi:10.3389/fphys.2019.01179 · Cited by 15
A comparative study of photoplethysmogram and piezoelectric plethysmogram signals
Qananwah, Q. M., Dagamseh, A., Alquran, H., Ibrahim, K. S., Alodat, M. T., & Hayden, O. (2020) · Physical and Engineering Sciences in Medicine · doi:10.1007/s13246-020-00923-x · Cited by 14
Cited by
Thin, soft, wearable system for continuous wireless monitoring of artery blood pressure
Li, J., Jia, H., Zhou, J., Huang, X., Xu, L., Jia, S., Gao, Z., Yao, K., Li, D., Zhang, B., et al. (2023) · Nature Communications · doi:10.1038/s41467-023-40763-3 · Cited by 293
Min, S., Kim, D. H., Joe, D. J., Kim, B. W., Jung, Y. H., Lee, J. H., Lee, B., Doh, I., An, J., Youn, Y., et al. (2023) · Advanced Materials · doi:10.1002/adma.202301627 · Cited by 278
Metadata
- Authors
- Yi, Z., Liu, Z., Li, W., Ruan, T., Chen, X., Liu, J., Yang, B., & Zhang, W.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2022-03-14
- Volume
- 34
- Issue
- 16
- Pages
- e2110291-e2110291
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W4220786439
- Cited by
- 265
- References
- 35
- FWCI
- 15.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.