CoChat

Fully Bioabsorbable Capacitor as an Energy Storage Unit for Implantable Medical Electronics

Open access
Li, Hu, Zhao, Chaochao, Wang, Xinxin, Meng, Jianping, Zou, Yang, Noreen, Sehrish, Zhao, Luming, Liu, Zhuo, Ouyang, Han, Tan, Puchuan, Yu, Min, Fan, Yubo, Wang, Zhong Lin, Li, Zhou · 2019 · Advanced Science
Cited by 151

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Implantable medical electronic devices are usually powered by batteries or capacitors, which have to be removed from the body after completing their function due to their non‐biodegradable property. Here, a fully bioabsorbable capacitor (BC) is developed for life‐time implantation. The BC has a symmetrical layer‐by‐layer structure, including polylactic acid (PLA) supporting substrate, PLA nanopillar arrays, self‐assembled zinc oxide nanoporous layer, and polyvinyl alcohol/phosphate buffer solution (PVA/PBS) hydrogel. The as‐fabricated BC can not only work normally in air but also in a liquid environment, including PBS and the animal body. Long‐term normal work time is achieved to 30 days in PBS and 50 days in Sprague–Dawley (SD) rats. The work time of BC in the liquid environment is tunable from days to weeks by adopting different encapsulations along BC edges. Capacitance retention of 70% is achieved after 3000 cycles. Three BCs in series can light up 15 green light‐emitting diodes (LEDs) in vivo. Additionally, after completing its mission, the BC can be fully degraded in vivo and reabsorbed by a SD rat. Considering its performance, the developed BC has a great potential as a fully bioabsorbable power source for transient electronics and implantable medical devices.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/advs.201801625

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 151

Metadata

Authors
Li, H., Zhao, C., Wang, X., Meng, J., Zou, Y., Noreen, S., Zhao, L., Liu, Z., Ouyang, H., Tan, P., Yu, M., Fan, Y., Wang, Z. L., & Li, Z.
Venue
Advanced Science
Publisher
Wiley
Published
2019-01-22
Volume
6
Issue
6
Pages
1801625-1801625
ISSN
2198-3844 (ISSN-L)
OpenAlex
W2912036416
Cited by
151
References
8
FWCI
5.31
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Fully Bioabsorbable Capacitor as an Energy Storage Unit for Implantable Medical Electronics. https://app.cochat.ai/papers/10.1002/advs.201801625
The paper
Li, H., Zhao, C., Wang, X., Meng, J., Zou, Y., Noreen, S., Zhao, L., Liu, Z., Ouyang, H., Tan, P., Yu, M., Fan, Y., Wang, Z. L., & Li, Z. (2019). Fully Bioabsorbable Capacitor as an Energy Storage Unit for Implantable Medical Electronics. Advanced Science. https://doi.org/10.1002/advs.201801625

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.