Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 260

The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.

Simultaneous Fenton‐like Ion Delivery and Glutathione Depletion by MnO2‐Based Nanoagent to Enhance Chemodynamic Therapy

Lin, Li‐Sen, Song, Jibin, Song, Liang, Ke, Kaimei, Liu, Yijing, Zhou, Zijian, Shen, Zheyu, Li, Juan, Yang, Zhen, Tang, Wei, Niu, Gang, Yang, Huang‐Hao, Chen, Xiaoyuan · 2018 · Angewandte Chemie

Abstract

Chemodynamic therapy (CDT) utilizes iron‐initiated Fenton chemistry to destroy tumor cells by converting endogenous H 2 O 2 into the highly toxic hydroxyl radical (.OH). There is a paucity of Fenton‐like metal‐based CDT agents. Intracellular glutathione (GSH) with .OH scavenging ability greatly reduces CDT efficacy. A self‐reinforcing CDT nanoagent based on MnO 2 is reported that has both Fenton‐like Mn 2+ delivery and GSH depletion properties. In the presence of HCO 3−, which is abundant in the physiological medium, Mn 2+ exerts Fenton‐like activity to generate .OH from H 2 O 2. Upon uptake of MnO 2‐coated mesoporous silica nanoparticles (MS@MnO 2 NPs) by cancer cells, the MnO 2 shell undergoes a redox reaction with GSH to form glutathione disulfide and Mn 2+, resulting in GSH depletion‐enhanced CDT. This, together with the GSH‐activated MRI contrast effect and dissociation of MnO 2, allows MS@MnO 2 NPs to achieve MRI‐monitored chemo–chemodynamic combination therapy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/ange.201712027

Cites

37 of 37 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 8

  1. Tang Z., 2018, Adv. Mater.
  2. Szatrowski T. P., 1991, Cancer Res., 51, 794
  3. 10.1002/anie.201504186 · doi:10.1002/anie.201504186
  4. 10.1002/ange.201504186 · doi:10.1002/ange.201504186
  5. Kuppusamy P., 2002, Cancer Res., 62, 307
  6. Russo A., 1986, Cancer Res., 46, 2845
  7. Arrick B. A., 1984, Cancer Res., 44, 4224
  8. 10.1002/(SICI)1096-9101(1998)23:3<161::AID-LSM5>3.0.CO;2-N · doi:10.1002/(sici)1096-9101(1998)23:3<161::aid-lsm5>3.0.co;2-n

Cited by

See all 260

Metadata

Authors
Lin, L., Song, J., Song, L., Ke, K., Liu, Y., Zhou, Z., Shen, Z., Li, J., Yang, Z., Tang, W., Niu, G., Yang, H., & Chen, X.
Venue
Angewandte Chemie
Publisher
Wiley
Published
2018-03-23
Volume
130
Issue
18
Pages
4996-5000
ISSN
  • 0044-8249 (ISSN-L)
  • 1521-3757
OpenAlex
W4236767042
Cited by
260
References
37
FWCI
10.57
Type
journal article
Language
en
Open access
closed
Funders
National Institute of Biomedical Imaging and Bioengineering (ZIA EB000073)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.