Electrospray Wings for Molecular Elephants (Nobel Lecture)
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
From flames to flying elephants: A few years ago the idea of making proteins or polymers “fly” by electrospray ionization (ESI) seemed as improbable as a flying elephant, but today it is a standard part of modern mass spectrometers. The key to this success was the development of free jet technology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Self-citationLaser desorption ionization of proteins with molecular masses exceeding 10,000 daltons
Karas, M., & Hillenkamp, F. (1988) · Analytical Chemistry · doi:10.1021/ac00171a028 · Cited by 5,637
Disintegration of water drops in an electric field
Taylor, G. I. (1964) · Proceedings of the Royal Society of London. Series A. Mathematical and Physical Sciences · doi:10.1098/rspa.1964.0151 · Cited by 3,305
Protein and polymer analyses up to m/z 100 000 by laser ionization time‐of‐flight mass spectrometry
Tanaka, K., Waki, H., Ido, Y., Akita, S., Yoshida, Y., Yoshida, T., & Matsuo, T. (1988) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290020802 · Cited by 3,175
XX. On the equilibrium of liquid conducting masses charged with electricity
Rayleigh, L. (1882) · The London, Edinburgh, and Dublin Philosophical Magazine and Journal of Science · doi:10.1080/14786448208628425 · Cited by 1,825
Dole, M., Mack, L. L., Hines, R. L., Mobley, R. C., Ferguson, L. D., & Alice, M. B. (1968) · The Journal of Chemical Physics · doi:10.1063/1.1670391 · Cited by 1,613
On the evaporation of small ions from charged droplets
Iribarne, J. V., & Thomson, B. A. (1976) · The Journal of Chemical Physics · doi:10.1063/1.432536 · Cited by 1,281
Fast atom bombardment of solids (F.A.B.): a new ion source for mass spectrometry
Barber, M., Bordoli, R. S., Sedgwick, R. D., & Tyler, A. N. (1981) · Journal of the Chemical Society, Chemical Communications · doi:10.1039/c39810000325 · Cited by 1,106
Instability of Electrified Liquid Surfaces
Zeleny, J. (1917) · Physical Review · doi:10.1103/physrev.10.1 · Cited by 944
Charge and fission of droplets in electrostatic sprays
Gomez, A., & Tang, K. (1994) · Physics of Fluids · doi:10.1063/1.868037 · Cited by 654
Cited by
Supramolecular Coordination: Self-Assembly of Finite Two- and Three-Dimensional Ensembles
Chakrabarty, R., Mukherjee, P. S., & Stang, P. J. (2011) · Chemical Reviews · doi:10.1021/cr200077m · Cited by 2,926
Unraveling the Mechanism of Electrospray Ionization
Konermann, L., Ahadi, E., Rodriguez, A. D., & Vahidi, S. (2013) · Analytical Chemistry · doi:10.1021/ac302789c · Cited by 735
Banerjee, S., & Mazumdar, S. (2012) · International Journal of Analytical Chemistry · doi:10.1155/2012/282574 · Cited by 662
Han, X., Yang, K., & Gross, R. W. (2012) · Mass Spectrometry Reviews · doi:10.1002/mas.20342 · Cited by 530
Demarque, D. P., Crotti, A. E. M., Vessecchi, R., Lopes, J. L. C., & Lopes, N. P. (2016) · Natural Product Reports · doi:10.1039/c5np00073d · Cited by 513
High-Resolution Native Mass Spectrometry
Tamara, S., den Boer, M. A., & Heck, A. J. R. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00212 · Cited by 511
Advances in structure elucidation of small molecules using mass spectrometry
Kind, T., & Fiehn, O. (2010) · Bioanalytical Reviews · doi:10.1007/s12566-010-0015-9 · Cited by 480
Selective Activation of Alkanes by Gas-Phase Metal Ions
Roithová, J., & Schröder, D. (2010) · Chemical Reviews · doi:10.1021/cr900183p · Cited by 477
Mass spectrometry tools for the classification and identification of bacteria
Sauer, S., & Kliem, M. (2010) · Nature Reviews Microbiology · doi:10.1038/nrmicro2243 · Cited by 461
Mechanisms of Plasma Polymerization – Reviewed from a Chemical Point of View
Friedrich, J. (2011) · Plasma Processes and Polymers · doi:10.1002/ppap.201100038 · Cited by 441
Targeted Metabolomics for Biomarker Discovery
Griffiths, W. J., Koal, T., Wang, Y., Kohl, M., Enot, D. P., & Deigner, H. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200905579 · Cited by 415
Wyttenbach, T., & Bowers, M. T. (2011) · The Journal of Physical Chemistry B · doi:10.1021/jp206867a · Cited by 346
Electron-induced damage of DNA and its components: Experiments and theoretical models
Baccarelli, I., Bald, I., Gianturco, F. A., Illenberger, E., & Kopyra, J. (2011) · Physics Reports · doi:10.1016/j.physrep.2011.06.004 · Cited by 323
Electrosprays in the cone-jet mode: From Taylor cone formation to spray development
Rosell-Llompart, J., Grifoll, J., & Loscertales, I. G. (2018) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2018.04.008 · Cited by 300
OMICS-driven biomarker discovery in nutrition and health
Kussmann, M., Raymond, F., & Affolter, M. (2006) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2006.02.014 · Cited by 286
Ultrafast dynamics in isolated molecules and molecular clusters
Hertel, I. V., & Radloff, W. (2006) · Reports on Progress in Physics · doi:10.1088/0034-4885/69/6/r06 · Cited by 265
Kachala, V. V., Khemchyan, L. L., Kashin, A. S., Orlov, N. V., Grachev, A. A., Zalesskiy, S. S., & Ananikov, V. P. (2013) · Russian Chemical Reviews · doi:10.1070/rc2013v082n07abeh004413 · Cited by 262
The foundations and development of lipidomics
Han, X., & Gross, R. W. (2022) · Journal of Lipid Research · doi:10.1016/j.jlr.2021.100164 · Cited by 249
Serine Octamers: Cluster Formation, Reactions, and Implications for Biomolecule Homochirality
Nanita, S. C., & Cooks, R. G. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200501328 · Cited by 184
Do ionic charges in ESI MS provide useful information on macromolecular structure?
Kaltashov, I. A., & Abzalimov, R. R. (2008) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2008.05.018 · Cited by 170
“However, it was the realization that multiple charging is an intrinsic property of ESI process and must be dealt with using mathematical tools, that made it a practical tool for the analysis of macromolecules [5].”
BackgroundNeutral particle mass spectrometry with nanomechanical systems
Sage, E., Brenac, A., Alava, T., Morel, R., Dupré, C., Hanay, M. S., Roukes, M. L., Duraffourg, L., Masselon, C., & Hentz, S. (2015) · Nature Communications · doi:10.1038/ncomms7482 · Cited by 164
Hedges, J. B., Vahidi, S., Yue, X., & Konermann, L. (2013) · Analytical Chemistry · doi:10.1021/ac401020s · Cited by 109
Metadata
- Authors
- Fenn, J. B.
- Venue
- Angewandte Chemie International Edition
- Publisher
- Wiley
- Published
- 2003-08-22
- Volume
- 42
- Issue
- 33
- Pages
- 3871-3894
- ISSN
- 1433-7851 (ISSN-L)
- 1521-3773
- OpenAlex
- W2154912073
- Cited by
- 642
- References
- 22
- FWCI
- 8.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.