The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
A Ratiometric Fluorescent Probe Based on FRET for Imaging Hg 2+ Ions in Living Cells
Abstract
Mercury rising: A FRET-based ratiometric probe (see picture; FRET=fluorescence resonance energy transfer) can selectively detect Hg2+ ions on the parts-per-billion scale under physiological conditions. The probe undergoes a clear Hg2+-induced change in the intensity ratio of the two well-separated and equally intense emission bands of dipyrrometheneboron difluoride and rhodamine. Experiments show that the probe can be used in living cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Signaling Recognition Events with Fluorescent Sensors and Switches
de Silva, A. P., Gunaratne, H. Q. N., Gunnlaugsson, T., Huxley, A. J. M., McCoy, C. P., Rademacher, J. T., & Rice, T. E. (1997) · Chemical Reviews · doi:10.1021/cr960386p · Cited by 6,995
BODIPY Dyes and Their Derivatives: Syntheses and Spectroscopic Properties
Loudet, A., & Burgess, K. (2007) · Chemical Reviews · doi:10.1021/cr078381n · Cited by 5,238
Sapsford, K. E., Berti, L., & Medintz, I. L. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200503873 · Cited by 1,561
Highly Selective Oligonucleotide‐Based Sensor for Mercury(II) in Aqueous Solutions
Ono, A., & Togashi, H. (2004) · Angewandte Chemie International Edition · doi:10.1002/anie.200454172 · Cited by 1,162
Yang, Y.-K., Yook, K.-J., & Tae, J. (2005) · Journal of the American Chemical Society · doi:10.1021/ja054855t · Cited by 1,044
Handbook of fluorescent probes and research products
Haugland, R. P. (2002) · Cited by 1,032
The chemistry of Bodipy: A new El Dorado for fluorescence tools
Ziessel, R., Ulrich, G., & Harriman, A. (2007) · New Journal of Chemistry · doi:10.1039/b617972j · Cited by 949
Rurack, K., Kollmannsberger, M., Resch-Genger, U., & Daub, J. (2000) · Journal of the American Chemical Society · doi:10.1021/ja992630a · Cited by 685
Calorimetric determinations of absolute fluorescence quantum yields
Olmsted, J. (1979) · The Journal of Physical Chemistry · doi:10.1021/j100483a006 · Cited by 649
A Selective Fluorescent Sensor for Imaging Cd2+ in Living Cells
Peng, X., Du, J., Fan, J., Wang, J., Wu, Y., Zhao, J., Sun, S., & Xu, T. (2007) · Journal of the American Chemical Society · doi:10.1021/ja0643319 · Cited by 617
Liu, J., & Lu, Y. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200702006 · Cited by 593
Srikun, D., Miller, E. W., Domaille, D. W., & Chang, C. J. (2008) · Journal of the American Chemical Society · doi:10.1021/ja711480f · Cited by 543
In Vivo Monitoring of Mercury Ions Using a Rhodamine-Based Molecular Probe
Ko, S.-K., Yang, Y.-K., Tae, J., & Shin, I. (2006) · Journal of the American Chemical Society · doi:10.1021/ja065114a · Cited by 509
Screening Mercury Levels in Fish with a Selective Fluorescent Chemosensor
Yoon, S., Albers, A. E., Wong, A. P., & Chang, C. J. (2005) · Journal of the American Chemical Society · doi:10.1021/ja0557987 · Cited by 503
Turn-On and Ratiometric Mercury Sensing in Water with a Red-Emitting Probe
Nolan, E. M., & Lippard, S. J. (2007) · Journal of the American Chemical Society · doi:10.1021/ja068879r · Cited by 428
Fluorescence ratio imaging: a new window into intracellular ionic signaling
Tsien, R. Y., & Poenie, M. (1986) · Trends in Biochemical Sciences · doi:10.1016/0968-0004(86)90245-8 · Cited by 414
Coskun, A., & Akkaya, E. U. (2006) · Journal of the American Chemical Society · doi:10.1021/ja066144g · Cited by 391
A Bright and Specific Fluorescent Sensor for Mercury in Water, Cells, and Tissue
Yoon, S., Miller, E. W., He, Q., Do, P. H., & Chang, C. J. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200701785 · Cited by 390
A FRET-Based Approach to Ratiometric Fluorescence Detection of Hydrogen Peroxide
Albers, A. E., Okreglak, V. S., & Chang, C. J. (2006) · Journal of the American Chemical Society · doi:10.1021/ja063308k · Cited by 375
Inorganic mercury (Hg2+) transport through lipid bilayer membranes
Gutknecht, J. (1981) · The Journal of Membrane Biology · doi:10.1007/bf01870753 · Cited by 364
Kiyose, K., Kojima, H., Urano, Y., & Nagano, T. (2006) · Journal of the American Chemical Society · doi:10.1021/ja060399c · Cited by 337
Highly Sensitive and Selective Chemosensor for Hg2+ Based on the Rhodamine Fluorophore
Lee, M. H., Wu, J.-S., Lee, J. W., Jung, J. H., & Kim, J. S. (2007) · Organic Letters · doi:10.1021/ol0708931 · Cited by 317
Descalzo, A. B., Martínez-Máñez, R., Radeglia, R., Rurack, K., & Soto, J. (2003) · Journal of the American Chemical Society · doi:10.1021/ja0290779 · Cited by 309
Wegner, S. V., Okesli, A., Chen, P., & He, C. (2007) · Journal of the American Chemical Society · doi:10.1021/ja068342d · Cited by 271
Bis(2-pyridyl)-Substituted Boratriazaindacene as an NIR-Emitting Chemosensor for Hg(II)
Coskun, A., Yilmaz, M. D., & Akkaya, E. U. (2007) · Organic Letters · doi:10.1021/ol062867t · Cited by 244
Development of a novel rhodamine-type fluorescent probe to determine peroxynitrite
Yang, X.-F., Guo, X.-Q., & Zhao, Y.-B. (2002) · Talanta · doi:10.1016/s0039-9140(02)00120-0 · Cited by 243
Wu, D., Descalzo, A. B., Weik, F., Emmerling, F., Shen, Z., You, X., & Rurack, K. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200702854 · Cited by 135
Sapsford, K. E., Berti, L., & Medintz, I. L. (2006) · Angewandte Chemie · doi:10.1002/ange.200503873 · Cited by 126
Water-Soluble Through-Bond Energy Transfer Cassettes for Intracellular Imaging
Bandichhor, R., Petrescu, A. D., Vespa, A., Kier, A. B., Schroeder, F., & Burgess, K. (2006) · Journal of the American Chemical Society · doi:10.1021/ja063784a · Cited by 119
Energy Transfer in Calixarene-Based Cofacial-Positioned Perylene Bisimide Arrays
Hippius, C., Schlosser, F., Vysotsky, M. O., et al. (2006) · Journal of the American Chemical Society · doi:10.1021/ja058007+ · Cited by 106
Visible Study of Mercuric Ion and Its Conjugate in Living Cells of Mammals and Plants
Zhang, Z., Wu, D., Guo, X., Qian, X. H., Lu, Z., Xu, Q. L., Yang, Y., Duan, L., He, Y., & Feng, Z. (2005) · Chemical Research in Toxicology · doi:10.1021/tx0501536 · Cited by 102
Self-citationA Bright and Specific Fluorescent Sensor for Mercury in Water, Cells, and Tissue
Yoon, S., Miller, E. W., He, Q., Patrick, H., & Chang, C. J. (2007) · Angewandte Chemie · doi:10.1002/ange.200701785 · Cited by 65
Cicchetti, G., Biernacki, M. A., Farquharson, J., & Allen, P. G. (2004) · Biochemistry · doi:10.1021/bi035480w · Cited by 64
Wu, D., Descalzo, A. B., Weik, F., et al. (2007) · Angewandte Chemie · doi:10.1002/ange.200702854 · Cited by 32
Cited by
Fluorescent indicators based on BODIPY
Boens, N., Leen, V., & Dehaen, W. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15132k · Cited by 2,262
Fluorescent Chemosensors Based on Spiroring-Opening of Xanthenes and Related Derivatives
Chen, X., Pradhan, T., Wang, F., Kim, J. S., & Yoon, J. (2012) · Chemical Reviews · doi:10.1021/cr200201z · Cited by 1,984
Reaction-based small-molecule fluorescent probes for chemoselective bioimaging
Chan, J., Dodani, S. C., & Chang, C. J. (2012) · Nature Chemistry · doi:10.1038/nchem.1500 · Cited by 1,883
Design Strategies for Water-Soluble Small Molecular Chromogenic and Fluorogenic Probes
Li, X., Gao, X., Shi, W., & Ma, H. (2014) · Chemical Reviews · doi:10.1021/cr300508p · Cited by 1,729
Synthesis and applications of Rhodamine derivatives as fluorescent probes
Beija, M., Afonso, C. A. M., & Martinho, J. M. G. (2009) · Chemical Society Reviews · doi:10.1039/b901612k · Cited by 1,463
Metadata
- Authors
- Zhang, X., Xiao, Y., & Qian, X.
- Venue
- Angewandte Chemie International Edition
- Publisher
- Wiley
- Published
- 2008-09-29
- Volume
- 47
- Issue
- 42
- Pages
- 8025-8029
- ISSN
- 1433-7851 (ISSN-L)
- 1521-3773
- OpenAlex
- W2147954408
- Cited by
- 800
- References
- 34
- FWCI
- 24.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.