The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Highly Efficient Capture of Circulating Tumor Cells by Using Nanostructured Silicon Substrates with Integrated Chaotic Micromixers
Open accessAbstract
Finding a needle in a haystack: A new technology is demonstrated to enrich circulating tumor cells (CTCs) with high efficiency by integrating an antibody-coated silicon nanopillar (SiNP, see picture; gray) substrate with an overlaid polydimethylsiloxane (PDMS) microfluidic chaotic mixer (turquoise). It shows significantly improved sensitivity in detecting rare CTCs from whole blood, thus providing an alternative for monitoring cancer progression.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The pathogenesis of cancer metastasis: the ‘seed and soil’ hypothesis revisited
Fidler, I. J. (2003) · Nature Reviews Cancer · doi:10.1038/nrc1098 · Cited by 4,686
Circulating Tumor Cells, Disease Progression, and Survival in Metastatic Breast Cancer
Cristofanilli, M., Budd, G. T., Ellis, M. J., Stopeck, A., Matera, J., Miller, M. C., Reuben, J. M., Doyle, G. V., Allard, W. J., Terstappen, L. W. M. M., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa040766 · Cited by 4,593
Isolation of rare circulating tumour cells in cancer patients by microchip technology
Nagrath, S., Sequist, L. V., Maheswaran, S., Bell, D. W., Irimia, D., Ulkus, L., Smith, M. R., Kwak, E. L., Digumarthy, S., Muzikansky, A., et al. (2007) · Nature · doi:10.1038/nature06385 · Cited by 3,559
Chaotic Mixer for Microchannels
Stroock, A. D., Dertinger, S. K. W., Ajdari, A., Mezić, I., Stone, H. A., & Whitesides, G. M. (2002) · Science · doi:10.1126/science.1066238 · Cited by 3,435
Metastasis: from dissemination to organ-specific colonization
Nguyen, D. X., Bos, P. D., & Massagué, J. (2009) · Nature Reviews Cancer · doi:10.1038/nrc2622 · Cited by 2,649
Tumor metastasis: mechanistic insights and clinical challenges
Steeg, P. S. (2006) · Nature Medicine · doi:10.1038/nm1469 · Cited by 2,134
Genes that mediate breast cancer metastasis to the brain
Bos, P. D., Zhang, X. H.-F., Nadal, C., Shu, W., Gomis, R. R., Nguyen, D. X., Minn, A. J., van de Vijver, M. J., Gerald, W. L., Foekens, J. A., et al. (2009) · Nature · doi:10.1038/nature08021 · Cited by 1,863
Dissecting the metastatic cascade
Pantel, K., & Brakenhoff, R. H. (2004) · Nature Reviews Cancer · doi:10.1038/nrc1370 · Cited by 1,281
Passive mixing in a three-dimensional serpentine microchannel
Liu, R. H., Stremler, M. A., Sharp, K. V., Olsen, M. G., Santiago, J. G., Adrian, R. J., Aref, H., & Beebe, D. J. (2000) · Journal of Microelectromechanical Systems · doi:10.1109/84.846699 · Cited by 1,197
Detection, clinical relevance and specific biological properties of disseminating tumour cells
Pantel, K., Brakenhoff, R. H., & Brandt, B. (2008) · Nature Reviews Cancer · doi:10.1038/nrc2375 · Cited by 1,118
Cited by
Nature-inspired superwettability systems
Liu, M., Wang, S., & Jiang, L. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2017.36 · Cited by 1,726
Self-citationCancer biomarker detection: recent achievements and challenges
Wu, L., & Qu, X. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00370e · Cited by 1,214
Ozkumur, E., Shah, A. M., Ciciliano, J. C., Emmink, B. L., Miyamoto, D. T., Brachtel, E., Yu, M., Chen, P.-I., Morgan, B., Trautwein, J., et al. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3005616 · Cited by 1,086
Wongkaew, N., Simsek, M., Griesche, C., & Baeumner, A. J. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00172 · Cited by 657
Ultrasensitive detection of circulating exosomes with a 3D-nanopatterned microfluidic chip
Zhang, P., Zhou, X., He, M., Shang, Y., Tetlow, A. L., Godwin, A. K., & Zeng, Y. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0356-9 · Cited by 554
Ultra-fast, label-free isolation of circulating tumor cells from blood using spiral microfluidics
Warkiani, M. E., Khoo, B. L., Wu, L., Tay, A. K. P., Bhagat, A. A. S., Han, J., & Lim, C. T. (2016) · Nature Protocols · doi:10.1038/nprot.2016.003 · Cited by 548
Interfacial Material System Exhibiting Superwettability
Tian, Y., Su, B., & Jiang, L. (2014) · Advanced Materials · doi:10.1002/adma.201400883 · Cited by 519
Bioinspired Designs of Superhydrophobic and Superhydrophilic Materials
Si, Y., Dong, Z., & Jiang, L. (2018) · ACS Central Science · doi:10.1021/acscentsci.8b00504 · Cited by 507
Silicon Nanomaterials Platform for Bioimaging, Biosensing, and Cancer Therapy
Peng, F., Su, Y., Zhong, Y., Fan, C., Lee, S.-T., & He, Y. (2014) · Accounts of Chemical Research · doi:10.1021/ar400221g · Cited by 491
Zhang, P., He, M., & Zeng, Y. (2016) · Lab on a Chip · doi:10.1039/c6lc00279j · Cited by 385
Technologies for circulating tumor cell separation from whole blood
Bankó, P., Lee, S. Y., Nagygyörgy, V., Zrínyi, M., Chae, C. H., Cho, D. H., & Telekes, A. (2019) · Journal of Hematology & Oncology · doi:10.1186/s13045-019-0735-4 · Cited by 358
Detecting Circulating Tumor Cells: Current Challenges and New Trends
Hong, B., & Zu, Y. (2013) · Theranostics · doi:10.7150/thno.5195 · Cited by 351
Accelerating the Translation of Nanomaterials in Biomedicine
Mitragotri, S., Anderson, D. G., Chen, X., Chow, E. K., Ho, D., Kabanov, A. V., Karp, J. M., Kataoka, K., Mirkin, C. A., Petrosko, S. H., et al. (2015) · ACS Nano · doi:10.1021/acsnano.5b03569 · Cited by 338
Self-citationAhn, J. C., Teng, P., Chen, P., Posadas, E., Tseng, H., Lu, S. C., & Yang, J. D. (2021) · Hepatology · doi:10.1002/hep.31165 · Cited by 338
Self-citationRare cell isolation and analysis in microfluidics
Chen, Y., Li, P., Huang, P.-H., Xie, Y., Mai, J. D., Wang, L., Nguyen, N.-T., & Huang, T. J. (2014) · Lab on a Chip · doi:10.1039/c3lc90136j · Cited by 307
Microfluidic approaches for cancer cell detection, characterization, and separation
Chen, J., Li, J., & Sun, Y. (2012) · Lab on a Chip · doi:10.1039/c2lc21273k · Cited by 301
Specific Capture and Release of Circulating Tumor Cells Using Aptamer‐Modified Nanosubstrates
Shen, Q., Xu, L., Zhao, L., Wu, D., Fan, Y., Zhou, Y., OuYang, W., Xu, X., Zhang, Z., Song, M., et al. (2013) · Advanced Materials · doi:10.1002/adma.201300082 · Cited by 300
Self-citationBio-inspired self-healing structural color hydrogel
Fu, F., Chen, Z., Zhao, Z., Wang, H., Shang, L., Gu, Z., & Zhao, Y. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1703616114 · Cited by 300
Double spiral microchannel for label-free tumor cell separation and enrichment
Sun, J., Li, M., Liu, C., Zhang, Y., Liu, D., Liu, W., Hu, G., & Jiang, X. (2012) · Lab on a Chip · doi:10.1039/c2lc40679a · Cited by 293
Bioinspired multivalent DNA network for capture and release of cells
Zhao, W., Cui, C. H., Bose, S., Guo, D., Shen, C., Wong, W. P., Halvorsen, K., Farokhzad, O. C., Teo, G. S. L., Phillips, J. A., et al. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1211234109 · Cited by 284
Self-citationThree-dimensional nano-biointerface as a new platform for guiding cell fate
Liu, X., & Wang, S. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60419e · Cited by 275
Self-citationKang, J. H., Krause, S., Tobin, H., Mammoto, A., Kanapathipillai, M., & Ingber, D. E. (2012) · Lab on a Chip · doi:10.1039/c2lc40072c · Cited by 274
Micro Total Analysis Systems for Cell Biology and Biochemical Assays
Kovarik, M. L., Gach, P. C., Ornoff, D. M., Wang, Y., Balowski, J., Farrag, L., & Allbritton, N. L. (2012) · Analytical Chemistry · doi:10.1021/ac202611x · Cited by 270
Park, M.-H., Reátegui, E., Li, W., Tessier, S. N., Wong, K. H. K., Jensen, A. E., Thapar, V., Ting, D., Toner, M., Stott, S. L., et al. (2017) · Journal of the American Chemical Society · doi:10.1021/jacs.6b12236 · Cited by 267
Biophysical Regulation of Cell Behavior—Cross Talk between Substrate Stiffness and Nanotopography
Yang, Y., Wang, K., Gu, X., & Leong, K. W. (2017) · Engineering · doi:10.1016/j.eng.2017.01.014 · Cited by 263
Capture and Stimulated Release of Circulating Tumor Cells on Polymer‐Grafted Silicon Nanostructures
Hou, S., Zhao, H., Zhao, L., Shen, Q., Wei, K. S., Suh, D. Y., Nakao, A., Garcia, M. A., Song, M., Lee, T., et al. (2013) · Advanced Materials · doi:10.1002/adma.201203185 · Cited by 260
Self-citationCancer Diagnosis: From Tumor to Liquid Biopsy and Beyond
Vaidyanathan, R., Soon, R. H., Zhang, P., Jiang, K., & Lim, C. T. (2018) · Lab on a Chip · doi:10.1039/c8lc00684a · Cited by 259
Sheng, W., Ogunwobi, O. O., Chen, T., Zhang, J., George, T. J., Liu, C., & Fan, Z. H. (2014) · Lab Chip · doi:10.1039/c3lc51017d · Cited by 257
Yuan, B., Jin, Y., Sun, Y., Wang, D., Sun, J., Wang, Z., Zhang, W., & Jiang, X. (2012) · Advanced Materials · doi:10.1002/adma.201104589 · Cited by 253
Chip in a lab: microfluidics for next generation life science research
Streets, A. M., & Huang, Y. (2013) · Biomicrofluidics · doi:10.1063/1.4789751 · Cited by 180
Earhart, C. M., Hughes, C. E., Gaster, R. S., Ooi, C. C., Wilson, R. J., Zhou, L. Y., Humke, E. W., Xu, L., Wong, D. J., Willingham, S. B., et al. (2014) · Lab Chip · doi:10.1039/c3lc50580d · Cited by 165
Self-citationNanotechnology: emerging tools for biology and medicine
Wong, I. Y., Bhatia, S. N., & Toner, M. (2013) · Genes & Development · doi:10.1101/gad.226837.113 · Cited by 132
Cells Cultured on Core–Shell Photonic Crystal Barcodes for Drug Screening
Fu, F., Shang, L., Zheng, F., Chen, Z., Wang, H., Wang, J., Gu, Z., & Zhao, Y. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b04966 · Cited by 118
Circulating Tumor Cells: Fluid Surrogates of Solid Tumors
Thiele, J.-A., Bethel, K., Králíčková, M., & Kuhn, P. (2017) · Annual Review of Pathology: Mechanisms of Disease · doi:10.1146/annurev-pathol-052016-100256 · Cited by 107
An integrated microfluidic chip for one-step isolation of circulating tumor cells
Lee, T. Y., Hyun, K.-A., Kim, S.-I., & Jung, H.-I. (2017) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2016.05.163 · Cited by 94
Self-citationRethinking liquid biopsy: Microfluidic assays for mobile tumor cells in human body fluids
Neoh, K. H., Hassan, A. A., Chen, A., Sun, Y., Liu, P., Xu, K.-F., Wong, A. S. T., & Han, R. P. S. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2017.10.006 · Cited by 44
Micro/nanofluidic technologies for efficient isolation and detection of circulating tumor cells
Yue, W.-Q., Tan, Z., Li, X.-P., Liu, F.-F., & Wang, C. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.06.009 · Cited by 34
Metadata
- Authors
- Wang, S., Liu, K., Liu, J., Yu, Z. T. ‐., Xu, X., Zhao, L., Lee, T., Lee, E. K., Reiss, J., Lee, Y., Chung, L. W. K., Huang, J., Rettig, M., Seligson, D., Duraiswamy, K. N., Shen, C. K. ‐., & Tseng, H.
- Venue
- Angewandte Chemie International Edition
- Publisher
- Wiley
- Published
- 2011-03-04
- Volume
- 50
- Issue
- 13
- Pages
- 3084-3088
- ISSN
- 1433-7851 (ISSN-L)
- 1521-3773
- OpenAlex
- W2166779888
- Cited by
- 620
- References
- 33
- FWCI
- 33.37
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.