The DOI matches its Crossref record; 63 of the 68 references it cites were found in a registry or an index.
Renal‐clearable Molecular Semiconductor for Second Near‐Infrared Fluorescence Imaging of Kidney Dysfunction
Open accessAbstract
Real‐time imaging of kidney function is important to assess the nephrotoxicity of drugs and monitor the progression of renal diseases; however, it remains challenging because of the lack of optical agents with high renal clearance and high signal‐to‐background ratio (SBR). Herein, a second near‐infrared (NIR‐II) fluorescent molecular semiconductor (CDIR2) is synthesized for real‐time imaging of kidney dysfunction in living mice. CDIR2 not only has a high renal clearance efficiency (≈90 % injection dosage at 24 h post‐injection), but also solely undergoes glomerular filtration into urine without being reabsorbed and secreted in renal tubules. Such a unidirectional renal clearance pathway of CDIR2 permits real‐time monitoring of kidney dysfunction in living mice upon nephrotoxic exposure. Thus, this study not only introduces a molecular renal probe but also provides useful molecular guidelines to increase the renal clearance efficiency of NIR‐II fluorescent agents.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“The CDIR2 probe was the first SWIR fluorogen used for a real-time evaluation of renal function in living animals.”
From The Pursuit of Shortwave Infrared-Emitting Nanoparticles with Bright Fluorescence through Molecular Design and Excited-State Engineering of Molecular Aggregates (2022) · cites this paper as [216]
The cited source says what the claim attributes to it.
In the citing paper
“After it is administered to mice, it passes through the glomeruli filtration system into urine without being reabsorbed or secreted in renal tubules.”
From The Pursuit of Shortwave Infrared-Emitting Nanoparticles with Bright Fluorescence through Molecular Design and Excited-State Engineering of Molecular Aggregates (2022) · cites this paper as [216]
The cited source says what the claim attributes to it.
In the citing paper
“This unilateral renal clearance pathway allowed one to monitor in real-time the kidney dysfunction during the progression of renal impairment.216”
From The Pursuit of Shortwave Infrared-Emitting Nanoparticles with Bright Fluorescence through Molecular Design and Excited-State Engineering of Molecular Aggregates (2022) · cites this paper as [216]
The cited source says what the claim attributes to it.
In the citing paper
“In vivo study, they observed CDIR2 has greater SBR than traditional NIR molecules (ICG or CCD), and has a high renal clearance efficiency with excellent biocompatibility.”
From Recent Advances in Nanomicelles Delivery Systems. (2020) · cites this paper as [198]
The cited source says what the claim attributes to it.
In the citing paper
“Pu and coworkers studied a new renal-clearable molecular semiconductor (CDIR2) that can real-time monitor kidney dysfunction in NIR-II components (Figure 13e), a NIR-II fluorophore with classic D-A-D structure (λem = 1050 nm) and a renal-clearance-enabling segment (HPbCD).”
From Recent Advances in Nanomicelles Delivery Systems. (2020) · cites this paper as [198]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Renal clearance of quantum dots
Soo Choi, H., Liu, W., Misra, P., Tanaka, E., Zimmer, J. P., Itty Ipe, B., Bawendi, M. G., & Frangioni, J. V. (2007) · Nature Biotechnology · doi:10.1038/nbt1340 · Cited by 4,476
Chronic kidney disease: global dimension and perspectives
Jha, V., Garcia-Garcia, G., Iseki, K., Li, Z., Naicker, S., Plattner, B., Saran, R., Wang, A. Y.-M., & Yang, C.-W. (2013) · The Lancet · doi:10.1016/s0140-6736(13)60687-x · Cited by 4,383
Near-infrared fluorophores for biomedical imaging
Hong, G., Antaris, A. L., & Dai, H. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-016-0010 · Cited by 3,048
Acute Kidney Injury and Chronic Kidney Disease as Interconnected Syndromes
Chawla, L. S., Eggers, P. W., Star, R. A., & Kimmel, P. L. (2014) · New England Journal of Medicine · doi:10.1056/nejmra1214243 · Cited by 1,984
A small-molecule dye for NIR-II imaging
Antaris, A. L., Chen, H., Cheng, K., Sun, Y., Hong, G., Qu, C., Diao, S., Deng, Z., Hu, X., Zhang, B., et al. (2016) · Nature Materials · doi:10.1038/nmat4476 · Cited by 1,778
Self-citationLovell, J. F., Jin, C. S., Huynh, E., Jin, H., Kim, C., Rubinstein, J. L., Chan, W. C. W., Cao, W., Wang, L. V., & Zheng, G. (2011) · Nature Materials · doi:10.1038/nmat2986 · Cited by 1,364
Fluoro- and Chromogenic Chemodosimeters for Heavy Metal Ion Detection in Solution and Biospecimens
Quang, D. T., & Kim, J. S. (2010) · Chemical Reviews · doi:10.1021/cr100154p · Cited by 1,362
Molecular imaging in drug development
Willmann, J. K., van Bruggen, N., Dinkelborg, L. M., & Gambhir, S. S. (2008) · Nature Reviews Drug Discovery · doi:10.1038/nrd2290 · Cited by 1,175
Li, J., & Pu, K. (2018) · Chemical Society Reviews · doi:10.1039/c8cs00001h · Cited by 1,169
Self-citationMolecular afterglow imaging with bright, biodegradable polymer nanoparticles
Miao, Q., Xie, C., Xu, Z. J., Lyu, Y., Duan, H., Liu, X., Jokerst, J. V., & Pu, K. (2017) · Nature Biotechnology · doi:10.1038/nbt.3987 · Cited by 980
Self-citation
Flagged first, then by citations
5 of the 68 references couldn’t be matched to a known paper.
Research works printed but not linked: 2
- Huang J., 2019, Nat. Mater.
- 10.1021/nl072014 · DOI
Cited by
Sorted by citations
Advanced Fluorescence Imaging Technology in the Near-Infrared-II Window for Biomedical Applications
Li, C., Chen, G., Zhang, Y., Wu, F., & Wang, Q. (2020) · Journal of the American Chemical Society · doi:10.1021/jacs.0c07022 · Cited by 1,037
Emerging combination strategies with phototherapy in cancer nanomedicine
Xie, Z., Fan, T., An, J., Choi, W., Duo, Y., Ge, Y., Zhang, B., Nie, G., Xie, N., Zheng, T., et al. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00215a · Cited by 718
Xu, M., Qi, Y., Liu, G. H., Song, Y., Jiang, X., & Du, B. (2023) · ACS Nano · doi:10.1021/acsnano.3c05853 · Cited by 654
J -Aggregates of Cyanine Dye for NIR-II in Vivo Dynamic Vascular Imaging beyond 1500 nm
Sun, C., Li, B., Zhao, M., Wang, S., Lei, Z., Lu, L., Zhang, H., Feng, L., Dou, C., Yin, D., et al. (2019) · Journal of the American Chemical Society · doi:10.1021/jacs.9b10043 · Cited by 582
In vivo NIR-II fluorescence imaging for biology and medicine
Wang, F., Zhong, Y., Bruns, O., Liang, Y., & Dai, H. (2024) · Nature Photonics · doi:10.1038/s41566-024-01391-5 · Cited by 564
“A caveat is that attaching highly hydrophilic side groups such as β-cyclodextrin (β-CD) 56 and poly(oligo(ethylene glycol) dimethacrylate) polymer brushes 48 to NIR-II fluorophores can facilitate renal excretion, but this typically lowers the fluorescence QY due to non-radiative relaxation of…”
Metadata
- Authors
- Huang, J., Xie, C., Zhang, X., Jiang, Y., Li, J., Fan, Q., & Pu, K.
- Affiliations
- Nanyang Technological University (SG)
- Nanjing University of Posts and Telecommunications (CN)
- Tianjin University (CN)
- School of Chemical and Biomedical Engineering Nanyang Technological University 70 Nanyang Drive Singapore 637457 Singapore
- Corresponding author
- Fan, Quli
- Pu, Kanyi
- Venue
- Angewandte Chemie International Edition
- Publisher
- Wiley
- Published
- 2019-09-05
- Volume
- 58
- Issue
- 42
- Pages
- 15120-15127
- ISSN
- 1433-7851 (ISSN-L)
- 1521-3773
- OpenAlex
- W2971196856
- Cited by
- 258
- References
- 68
- Citations by year
- 2026: 8 · 2025: 23 · 2024: 36 · 2023: 30 · 2022: 38 · 2021: 55 · 2020: 59 · 2019: 9
- FWCI
- 16.03
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Locations
- Angewandte Chemie International Edition (publishedVersion)
- PubMed (publishedVersion)
- DR-NTU (Nanyang Technological University) (submittedVersion)
- Funders
- Nanyang Technological University (Tier 1)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Molecular Sensors and Ion Detection
- Physical Sciences › Materials Science › Materials Chemistry › Luminescence and Fluorescent Materials
- Physical Sciences › Materials Science › Materials Chemistry › Quantum Dots Synthesis And Properties
- Keywords
- NIR-II fluorescence imaging, renal clearance, renal dysfunction, nephrotoxicity, glomerular filtration, drug-induced nephrotoxicity, signal-to-background ratio
- MeSH terms
- Animals, Cell Line, Female, Fluorescent Dyes, Kidney, Kidney Diseases, Kidney Function Tests, Metabolic Clearance Rate, Mice, Nude, Semiconductors, Spectroscopy, Near-Infrared, Mice, Optical Imaging
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review