CoChat

pH prediction and control in bioprocesses using mid‐infrared spectroscopy

Open access
Schenk, Jonas, Marison, Ian W., von Stockar, Urs · 2008 · Biotechnology and Bioengineering
Cited by 29

The DOI matches its Crossref record.

Abstract

An on‐line pH monitoring method based on mid‐infrared spectroscopy relevant to bioprocesses is presented. This approach is non‐invasive and does not require the addition of indicators or dyes, since it relies on the analysis of species of common buffers used in culture media, such as phosphate buffer. Starting with titrations of phosphoric and acetic acid solutions over almost the entire pH range (2–12), it was shown that the infrared spectra of all samples can be expressed as a linear combination of the molar absorbance of the acids and their deprotonated forms. In other words, pH had no direct influence on the molar infrared spectra themselves, but only on deprotonation equilibria. Accurate prediction (standard error of prediction for pH < 0.15 pH units) was achieved by taking into account the non‐ideal behavior of the solutions, using the Debye–Hückel theory to estimate the activity coefficients. Batch cultures of E. coli were chosen as a case study to show how this approach can be applied to bioprocess monitoring. The discrepancy between the spectroscopic prediction and the conventional electrochemical probe never exceeded 0.12 pH units, and the technique was fast enough to implement a feedback controller to maintain the pH constant during cultivation. Biotechnol. Bioeng. 2008;100: 82–93. © 2007 Wiley Periodicals, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/bit.21719

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 26

  1. ASTM, 1997, Standard practices for infrared, multivariate, quantitative analysis (E 1655‐97). Annual book of ASTM standards, 844
  2. Bailey JE, 1986, Biochemical engineering fundamentals
  3. 10.1139/cjc-78-4-490 · doi:10.1139/cjc-78-4-490
  4. 10.1023/A:1026784101162 · DOI
  5. 10.1021/bp990039b · DOI
  6. 10.1063/1.1416902 · DOI · Paper page
  7. 10.1002/bit.10212 · DOI
  8. 10.1017/S0022029903006344 · DOI
  9. 10.1007/s00217-005-0110-2 · doi:10.1007/s00217-005-0110-2
  10. 10.1021/bp0255560 · DOI · Paper page
  11. 10.1002/bit.10618 · DOI · Paper page
  12. 10.1016/j.lwt.2006.02.010 · doi:10.1016/j.lwt.2006.02.010
  13. Martens H, 1992, Multivariate calibration
  14. 10.1366/0003702981944788 · doi:10.1366/0003702981944788
  15. 10.1016/S0003-2670(01)95397-8 · DOI
  16. 10.1007/BF00645465 · DOI · Paper page
  17. 10.1007/s004490100226 · DOI
  18. 10.1002/bit.10134 · DOI · Paper page
  19. 10.1021/bp980022d · DOI
  20. 10.1016/j.jbiotec.2006.09.015 · DOI
  21. 10.1016/j.aca.2007.03.056 · DOI
  22. 10.1351/pac198456050567 · doi:10.1351/pac198456050567
  23. 10.1021/ac960917 · doi:10.1021/ac960917
  24. Steyer JP, 2002, On‐line measurement of COD, TOC, VFA, total and partial alkalinity in anaerobic processes using infra‐red spectrometry, Water Sci Technol, 45, 133, 10.2166/wst.2002.0310 · doi:10.2166/wst.2002.0310
  25. 10.1016/j.medengphy.2005.07.016 · DOI
  26. 10.1002/9780470938416 · DOI · Paper page

Cited by

See all 29

Metadata

Authors
Schenk, J., Marison, I. W., & von Stockar, U.
Venue
Biotechnology and Bioengineering
Publisher
Wiley
Published
2007-11-19
Volume
100
Issue
1
Pages
82-93
ISSN
  • 0006-3592 (ISSN-L)
  • 1097-0290
OpenAlex
W1995183712
Cited by
29
References
0
FWCI
1.62
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: pH prediction and control in bioprocesses using mid‐infrared spectroscopy. https://app.cochat.ai/papers/10.1002/bit.21719
The paper
Schenk, J., Marison, I. W., & von Stockar, U. (2008). pH prediction and control in bioprocesses using mid‐infrared spectroscopy. Biotechnology and Bioengineering. https://doi.org/10.1002/bit.21719

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.