384 hanging drop arrays give excellent Z‐factors and allow versatile formation of co‐culture spheroids
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
We previously reported the development of a simple, user‐friendly, and versatile 384 hanging drop array plate for 3D spheroid culture and the importance of utilizing 3D cellular models in anti‐cancer drug sensitivity testing. The 384 hanging drop array plate allows for high‐throughput capabilities and offers significant improvements over existing 3D spheroid culture methods. To allow for practical 3D cell‐based high‐throughput screening and enable broader use of the plate, we characterize the robustness of the 384 hanging drop array plate in terms of assay performance and demonstrate the versatility of the plate. We find that the 384 hanging drop array plate performance is robust in fluorescence‐ and colorimetric‐based assays through Z‐factor calculations. Finally, we demonstrate different plate capabilities and applications, including: spheroid transfer and retrieval for Janus spheroid formation, sequential addition of cells for concentric layer patterning of different cell types, and culture of a wide variety of cell types. Biotechnol. Bioeng. 2012; 109:1293–1304. © 2011 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zhang, J.-H., Chung, T. D. Y., & Oldenburg, K. R. (1999) · SLAS Discovery · doi:10.1177/108705719900400206 · Cited by 6,847
Modeling Tissue Morphogenesis and Cancer in 3D
Yamada, K. M., & Cukierman, E. (2007) · Cell · doi:10.1016/j.cell.2007.08.006 · Cited by 1,751
Spheroid-based drug screen: Considerations and practical approach
Friedrich, J., Seidel, C., Ebner, R., & Kunz-Schughart, L. A. (2009) · Nature Protocols · doi:10.1038/nprot.2008.226 · Cited by 1,742
Multicellular tumor spheroids: An underestimated tool is catching up again
Hirschhaeuser, F., Menne, H., Dittfeld, C., West, J., Mueller-Klieser, W., & Kunz-Schughart, L. A. (2010) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2010.01.012 · Cited by 1,674
Recent advances in three‐dimensional multicellular spheroid culture for biomedical research
Lin, R., & Chang, H. (2008) · Biotechnology Journal · doi:10.1002/biot.200700228 · Cited by 1,264
High-throughput 3D spheroid culture and drug testing using a 384 hanging drop array
Tung, Y.-C., Hsiao, A. Y., Allen, S. G., Torisawa, Y.-S., Ho, M., & Takayama, S. (2011) · The Analyst · doi:10.1039/c0an00609b · Cited by 969 · cited 3×
“General monoculture spheroid formation was performed as previously described (Tung et al., 2011).”
BackgroundMethodSelf-citationThe use of 3-d cultures for high-throughput screening: the multicellular spheroid model.
Kunz-Schughart, L. A., Freyer, J. P., Hofstaedter, F., & Ebner, R. (2004) · SLAS DISCOVERY · doi:10.1177/1087057104265040 · Cited by 797
Statistical methods for analysis of high-throughput RNA interference screens
Birmingham, A., Selfors, L. M., Forster, T., Wrobel, D., Kennedy, C. J., Shanks, E., Santoyo-Lopez, J., Dunican, D. J., Long, A., Kelleher, D., et al. (2009) · Nature Methods · doi:10.1038/nmeth.1351 · Cited by 586
A novel 3D mammalian cell perfusion-culture system in microfluidic channels
Toh, Y.-C., Zhang, C., Zhang, J., Khong, Y. M., Chang, S., Samper, V. D., van Noort, D., Hutmacher, D. W., & Yu, H. (2007) · Lab on a Chip · doi:10.1039/b614872g · Cited by 414 · cited 1×
“Emerging microtechnologies for spheroid formation (Fukuda et al., 2006; Lee et al., 2010; Sakai and Nakazawa, 2007; Toh et al., 2007; Torisawa et al., 2007a,b; Ungrin et al., 2008; Wu et al., 2008) generally offer considerable improvements for spheroid uniformity control, but such custom-made…”
BackgroundMulticellular spheroids in ovarian cancer metastases: Biology and pathology
Shield, K., Ackland, M. L., Ahmed, N., & Rice, G. E. (2009) · Gynecologic Oncology · doi:10.1016/j.ygyno.2008.11.032 · Cited by 412
Cited by
Opportunities and challenges for use of tumor spheroids as models to test drug delivery and efficacy
Mehta, G., Hsiao, A. Y., Ingram, M., Luker, G. D., & Takayama, S. (2012) · Journal of Controlled Release · doi:10.1016/j.jconrel.2012.04.045 · Cited by 1,172
Self-citationThree-Dimensional Cell Culture: A Breakthrough in Vivo
Antoni, D., Burckel, H., Josset, E., & Noel, G. (2015) · International Journal of Molecular Sciences · doi:10.3390/ijms16035517 · Cited by 990
Hoarau-Véchot, J., Rafii, A., Touboul, C., & Pasquier, J. (2018) · International Journal of Molecular Sciences · doi:10.3390/ijms19010181 · Cited by 489
“Spheroids can be maintained in culture for several weeks within the droplet array, allowing the development of complex experiments [17,18].”
BackgroundReconfigurable microfluidic hanging drop network for multi-tissue interaction and analysis
Frey, O., Misun, P. M., Fluri, D. A., Hengstler, J. G., & Hierlemann, A. (2014) · Nature Communications · doi:10.1038/ncomms5250 · Cited by 387
Engineering cancer microenvironments for in vitro 3-D tumor models
Asghar, W., El Assal, R., Shafiee, H., Pitteri, S., Paulmurugan, R., & Demirci, U. (2015) · Materials Today · doi:10.1016/j.mattod.2015.05.002 · Cited by 316
Moshksayan, K., Kashaninejad, N., Warkiani, M. E., Lock, J. G., Moghadas, H., Firoozabadi, B., Saidi, M. S., & Nguyen, N.-T. (2018) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2018.01.223 · Cited by 267
The multicellular tumor spheroid model for high-throughput cancer drug discovery
LaBarbera, D. V., Reid, B. G., & Yoo, B. H. (2012) · Expert Opinion on Drug Discovery · doi:10.1517/17460441.2012.708334 · Cited by 255
Design of spherically structured 3D in vitro tumor models -Advances and prospects
Ferreira, L. P., Gaspar, V. M., & Mano, J. F. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.05.034 · Cited by 249
Drug discovery through stem cell-based organoid models
Ranga, A., Gjorevski, N., & Lutolf, M. P. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.02.006 · Cited by 195
“Indeed such systems have been optimized for droplet stability [16], have been shown to be robust in fluorescence- and colorimetric-based assays through Z-factor calculations [17], and have allowed for the determination of differential effects on growth arrest with drugs.”
Microfluidic 3D models of cancer
Sung, K. E., & Beebe, D. J. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.07.002 · Cited by 190
Emerging tumor spheroids technologies for 3D in vitro cancer modeling
Rodrigues, T., Kundu, B., Silva-Correia, J., Kundu, S. C., Oliveira, J. M., Reis, R. L., & Correlo, V. M. (2018) · Pharmacology & Therapeutics · doi:10.1016/j.pharmthera.2017.10.018 · Cited by 178
3D spherical microtissues and microfluidic technology for multi-tissue experiments and analysis
Kim, J.-Y., Fluri, D. A., Marchan, R., Boonen, K., Mohanty, S., Singh, P., Hammad, S., Landuyt, B., Hengstler, J. G., Kelm, J. M., et al. (2015) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2015.01.003 · Cited by 126
Rodenhizer, D., Dean, T., D'Arcangelo, E., & McGuigan, A. P. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201701174 · Cited by 80
Toward the broad adoption of 3D tumor models in the cancer drug pipeline
Cox, M. C., Reese, L. M., Bickford, L. R., & Verbridge, S. S. (2015) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.5b00172 · Cited by 80
Shah, S., & D’Souza, G. G. M. (2025) · Cells · doi:10.3390/cells14100732 · Cited by 83
A Hollow Sphere Soft Lithography Approach for Long-Term Hanging Drop Methods
Lee, W. G., Ortmann, D., Hancock, M. J., Bae, H., & Khademhosseini, A. (2010) · Tissue Engineering Part C: Methods · doi:10.1089/ten.tec.2009.0248 · Cited by 62
Metadata
- Authors
- Hsiao, A. Y., Tung, Y., Qu, X., Patel, L. R., Pienta, K. J., & Takayama, S.
- Venue
- Biotechnology and Bioengineering
- Publisher
- Wiley
- Published
- 2011-12-20
- Volume
- 109
- Issue
- 5
- Pages
- 1293-1304
- ISSN
- 0006-3592 (ISSN-L)
- 1097-0290
- OpenAlex
- W2163299187
- Cited by
- 137
- References
- 13
- FWCI
- 4.74
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.