The DOI matches its Crossref record; 71 of the 71 references it cites were found in a registry or an index.
Microfluidic blood–brain barrier model provides in vivo‐like barrier properties for drug permeability screening
Open accessAbstract
Efficient delivery of therapeutics across the neuroprotective blood–brain barrier (BBB) remains a formidable challenge for central nervous system drug development. High‐fidelity in vitro models of the BBB could facilitate effective early screening of drug candidates targeting the brain. In this study, we developed a microfluidic BBB model that is capable of mimicking in vivo BBB characteristics for a prolonged period and allows for reliable in vitro drug permeability studies under recirculating perfusion. We derived brain microvascular endothelial cells (BMECs) from human induced pluripotent stem cells (hiPSCs) and cocultured them with rat primary astrocytes on the two sides of a porous membrane on a pumpless microfluidic platform for up to 10 days. The microfluidic system was designed based on the blood residence time in human brain tissues, allowing for medium recirculation at physiologically relevant perfusion rates with no pumps or external tubing, meanwhile minimizing wall shear stress to test whether shear stress is required for in vivo‐like barrier properties in a microfluidic BBB model. This BBB‐on‐a‐chip model achieved significant barrier integrity as evident by continuous tight junction formation and in vivo‐like values of trans‐endothelial electrical resistance (TEER). The TEER levels peaked above 4000 Ω · cm 2 on day 3 on chip and were sustained above 2000 Ω · cm 2 up to 10 days, which are the highest sustained TEER values reported in a microfluidic model. We evaluated the capacity of our microfluidic BBB model to be used for drug permeability studies using large molecules (FITC‐dextrans) and model drugs (caffeine, cimetidine, and doxorubicin). Our analyses demonstrated that the permeability coefficients measured using our model were comparable to in vivo values. Our BBB‐on‐a‐chip model closely mimics physiological BBB barrier functions and will be a valuable tool for screening of drug candidates. The residence time‐based design of a microfluidic platform will enable integration with other organ modules to simulate multi‐organ interactions on drug response. Biotechnol. Bioeng. 2017;114: 184–194. © 2016 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Induced Pluripotent Stem Cell Lines Derived from Human Somatic Cells
Yu, J., Vodyanik, M. A., Smuga-Otto, K., Antosiewicz-Bourget, J., Frane, J. L., Tian, S., Nie, J., Jonsdottir, G. A., Ruotti, V., Stewart, R., et al. (2007) · Science · doi:10.1126/science.1151526 · Cited by 10,310
Bhatia, S. N., & Ingber, D. E. (2014) · Nature Biotechnology · doi:10.1038/nbt.2989 · Cited by 3,305
The blood-brain barrier: Bottleneck in brain drug development
Pardridge, W. M. (2005) · NeuroRX · doi:10.1602/neurorx.2.1.3 · Cited by 2,798
TEER Measurement Techniques for In Vitro Barrier Model Systems
Srinivasan, B., Kolli, A. R., Esch, M. B., Abaci, H. E., Shuler, M. L., & Hickman, J. J. (2015) · SLAS Technology · doi:10.1177/2211068214561025 · Cited by 2,145
Self-citationFanning, A. S., Jameson, B. J., Jesaitis, L. A., & Anderson, J. M. (1998) · Journal of Biological Chemistry · doi:10.1074/jbc.273.45.29745 · Cited by 1,432
Blood‐brain barrier‐specific properties of a human adult brain endothelial cell line
Weksler, B. B., Subileau, E. A., Perrière, N., Charneau, P., Holloway, K., Leveque, M., Tricoire‐Leignel, H., Nicotra, A., Bourdoulous, S., Turowski, P., et al. (2005) · The FASEB Journal · doi:10.1096/fj.04-3458fje · Cited by 1,330
Astrocyte-endothelial Interactions and Blood-Brain Barrier Permeability*
Abbott, N. J. (2002) · Journal of Anatomy · doi:10.1046/j.1469-7580.2002.00064.x · Cited by 1,168
Haemodynamic shear stress activates a K+ current in vascular endothelial cells
Olesen, S.-P., Claphamt, D., & Davies, P. (1988) · Nature · doi:10.1038/331168a0 · Cited by 1,001
Koepsell, H., Lips, K., & Volk, C. (2007) · Pharmaceutical Research · doi:10.1007/s11095-007-9254-z · Cited by 988
Mechanotransduction and endothelial cell homeostasis: the wisdom of the cell
Chien, S. (2007) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01047.2006 · Cited by 907
Maschmeyer, I., Lorenz, A. K., Schimek, K., Hasenberg, T., Ramme, A. P., Hübner, J., Lindner, M., Drewell, C., Bauer, S., Thomas, A., et al. (2015) · Lab on a Chip · doi:10.1039/c5lc00392j · Cited by 861
Kleinfeld, D., Mitra, P. P., Helmchen, F., & Denk, W. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.26.15741 · Cited by 832
Derivation of blood-brain barrier endothelial cells from human pluripotent stem cells
Lippmann, E. S., Azarin, S. M., Kay, J. E., Nessler, R. A., Wilson, H. K., Al-Ahmad, A., Palecek, S. P., & Shusta, E. V. (2012) · Nature Biotechnology · doi:10.1038/nbt.2247 · Cited by 800
Boosting Brain Uptake of a Therapeutic Antibody by Reducing Its Affinity for a Transcytosis Target
Yu, Y. J., Zhang, Y., Kenrick, M., Hoyte, K., Luk, W., Lu, Y., Atwal, J., Elliott, J. M., Prabhu, S., Watts, R. J., et al. (2011) · Science Translational Medicine · doi:10.1126/scitranslmed.3002230 · Cited by 794
Characterization of a microfluidic in vitro model of the blood-brain barrier (μBBB)
Booth, R., & Kim, H. (2012) · Lab on a Chip · doi:10.1039/c2lc40094d · Cited by 739
The blood-brain barrier: an engineering perspective
Wong, A. D., Ye, M., Levy, A. F., Rothstein, J. D., Bergles, D. E., & Searson, P. C. (2013) · Frontiers in Neuroengineering · doi:10.3389/fneng.2013.00007 · Cited by 662
Fundamentals of microfluidic cell culture in controlled microenvironments
Young, E. W. K., & Beebe, D. J. (2010) · Chemical Society Reviews · doi:10.1039/b909900j · Cited by 615
De Keulenaer, G. W., Chappell, D. C., Ishizaka, N., Nerem, R. M., Alexander, R. W., & Griendling, K. K. (1998) · Circulation Research · doi:10.1161/01.res.82.10.1094 · Cited by 612
Blood–Brain Barrier Transport of Therapeutics via Receptor-Mediation
Jones, A. R., & Shusta, E. V. (2007) · Pharmaceutical Research · doi:10.1007/s11095-007-9379-0 · Cited by 549
Oscillatory Shear Stress Stimulates Adhesion Molecule Expression in Cultured Human Endothelium
Chappell, D. C., Varner, S. E., Nerem, R. M., Medford, R. M., & Alexander, R. W. (1998) · Circulation Research · doi:10.1161/01.res.82.5.532 · Cited by 548
Griep, L. M., Wolbers, F., de Wagenaar, B., ter Braak, P. M., Weksler, B. B., Romero, I. A., Couraud, P. O., Vermes, I., van der Meer, A. D., & van den Berg, A. (2013) · Biomedical Microdevices · doi:10.1007/s10544-012-9699-7 · Cited by 537
Lippmann, E. S., Al-Ahmad, A., Azarin, S. M., Palecek, S. P., & Shusta, E. V. (2014) · Scientific Reports · doi:10.1038/srep04160 · Cited by 508
The claudin gene family: expression in normal and neoplastic tissues
Hewitt, K. J., Agarwal, R., & Morin, P. J. (2006) · BMC Cancer · doi:10.1186/1471-2407-6-186 · Cited by 497
A microfluidic device for a pharmacokinetic–pharmacodynamic (PK–PD) model on a chip
Sung, J. H., Kam, C., & Shuler, M. L. (2010) · Lab on a Chip · doi:10.1039/b917763a · Cited by 484
Self-citationVan Itallie, C. M., Fanning, A. S., Bridges, A., & Anderson, J. M. (2009) · Molecular Biology of the Cell · doi:10.1091/mbc.e09-04-0320 · Cited by 476
Absorption and Drug Development: Solubility, Permeability, and Charge State
Avdeef, A. (2003) · Cited by 451
Absorption and Drug Development: Solubility, Permeability, and Charge State
Avdeef, A. (2012) · Wiley eBooks · doi:10.1002/9781118286067 · Cited by 446
Brown, J. A., Pensabene, V., Markov, D. A., Allwardt, V., Neely, M. D., Shi, M., Britt, C. M., Hoilett, O. S., Yang, Q., Brewer, B. M., et al. (2015) · Biomicrofluidics · doi:10.1063/1.4934713 · Cited by 410
Reconfigurable microfluidic hanging drop network for multi-tissue interaction and analysis
Frey, O., Misun, P. M., Fluri, D. A., Hengstler, J. G., & Hierlemann, A. (2014) · Nature Communications · doi:10.1038/ncomms5250 · Cited by 387
Kotamraju, S., Konorev, E. A., Joseph, J., & Kalyanaraman, B. (2000) · Journal of Biological Chemistry · doi:10.1074/jbc.m003890200 · Cited by 372
Astrocytic laminin regulates pericyte differentiation and maintains blood brain barrier integrity
Yao, Y., Chen, Z.-L., Norris, E. H., & Strickland, S. (2014) · Nature Communications · doi:10.1038/ncomms4413 · Cited by 357
SyM-BBB: a microfluidic blood brain barrier model
Prabhakarpandian, B., Shen, M.-C., Nichols, J. B., Mills, I. R., Sidoryk-Wegrzynowicz, M., Aschner, M., & Pant, K. (2013) · Lab on a Chip · doi:10.1039/c2lc41208j · Cited by 339
Effect of Aging on Elastin Functionality in Human Cerebral Arteries
Fonck, E., Feigl, G. G., Fasel, J., Sage, D., Unser, M., Rüfenacht, D. A., & Stergiopulos, N. (2009) · Stroke · doi:10.1161/strokeaha.108.528091 · Cited by 330
The Role of Body-on-a-Chip Devices in Drug and Toxicity Studies
Esch, M. B., King, T. L., & Shuler, M. L. (2011) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071910-124629 · Cited by 328
Self-citationEndothelial Cell Sensing of Flow Direction
Wang, C., Baker, B. M., Chen, C. S., & Schwartz, M. A. (2013) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/atvbaha.113.301826 · Cited by 294
Jo, H., Sipos, K., Go, Y.-M., Law, R., Rong, J., & McDonald, J. M. (1997) · Journal of Biological Chemistry · doi:10.1074/jbc.272.2.1395 · Cited by 270
Functional analysis of tight junctions
Matter, K., & Balda, M. S. (2003) · Methods · doi:10.1016/s1046-2023(03)00029-x · Cited by 264
Pumpless microfluidic platform for drug testing on human skin equivalents
Abaci, H. E., Gledhill, K., Guo, Z., Christiano, A. M., & Shuler, M. L. (2015) · Lab on a Chip · doi:10.1039/c4lc00999a · Cited by 262
Self-citationAbaci, H. E., & Shuler, M. L. (2015) · Integrative Biology · doi:10.1039/c4ib00292j · Cited by 243
Self-citationSung, J. H., Esch, M. B., Prot, J.-M., Long, C. J., Smith, A., Hickman, J. J., & Shuler, M. L. (2013) · Lab on a Chip · doi:10.1039/c3lc41017j · Cited by 233
Self-citationExtended delivery of ophthalmic drugs by silicone hydrogel contact lenses
Kim, J., Conway, A., & Chauhan, A. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.01.030 · Cited by 223
Santaguida, S., Janigro, D., Hossain, M., Oby, E., Rapp, E., & Cucullo, L. (2006) · Brain Research · doi:10.1016/j.brainres.2006.06.027 · Cited by 209
A modular approach to create a neurovascular unit-on-a-chip
Achyuta, A. K. H., Conway, A. J., Crouse, R. B., Bannister, E. C., Lee, R. N., Katnik, C. P., Behensky, A. A., Cuevas, J., & Sundaram, S. S. (2013) · Lab Chip · doi:10.1039/c2lc41033h · Cited by 191
Wolff, A., Antfolk, M., Brodin, B., & Tenje, M. (2015) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.24329 · Cited by 191
Simple room temperature bonding of thermoplastics and poly(dimethylsiloxane)
Sunkara, V., Park, D.-K., Hwang, H., Chantiwas, R., Soper, S. A., & Cho, Y.-K. (2011) · Lab Chip · doi:10.1039/c0lc00272k · Cited by 185
Three-Dimensional Blood-Brain Barrier Model for in vitro Studies of Neurovascular Pathology
Cho, H., Seo, J. H., Wong, K. H. K., Terasaki, Y., Park, J., Bong, K., Arai, K., Lo, E. H., & Irimia, D. (2015) · Scientific Reports · doi:10.1038/srep15222 · Cited by 184
A versatile lab-on-a-chip tool for modeling biological barriers
Walter, F. R., Valkai, S., Kincses, A., Petneházi, A., Czeller, T., Veszelka, S., Ormos, P., Deli, M. A., & Dér, A. (2016) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2015.07.110 · Cited by 177
Non-invasive measurement of solute permeability in cerebral microvessels of the rat
Yuan, W., Lv, Y., Zeng, M., & Fu, B. M. (2009) · Microvascular Research · doi:10.1016/j.mvr.2008.08.004 · Cited by 175
Multi-cellular 3D human primary liver cell culture elevates metabolic activity under fluidic flow
Esch, M. B., Prot, J.-M., Wang, Y. I., Miller, P., Llamas-Vidales, J. R., Naughton, B. A., Applegate, D. R., & Shuler, M. L. (2015) · Lab on a Chip · doi:10.1039/c5lc00237k · Cited by 173
Self-citationLRP-1-mediated intracellular antibody delivery to the Central Nervous System
Tian, X., Nyberg, S., Sharp, P. S., Madsen, J., Daneshpour, N., Armes, S. P., Berwick, J., Azzouz, M., Shaw, P., Abbott, N. J., et al. (2015) · Scientific Reports · doi:10.1038/srep11990 · Cited by 159
Blood-brain barrier transport of caffeine: Dose-related restriction of adenine transport
McCall, A. L., Millington, W. R., & Wurtman, R. J. (1982) · Life Sciences · doi:10.1016/0024-3205(82)90715-9 · Cited by 158
Collagen-based brain microvasculature modelin vitrousing three-dimensional printed template
Kim, J., Kim, H. N., Im, S.-K., Chung, S. H., Kang, J. Y., & Choi, N. (2015) · Biomicrofluidics · doi:10.1063/1.4917508 · Cited by 155
Cucullo, L., Marchi, N., Hossain, M., & Janigro, D. (2010) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2010.162 · Cited by 152
Ohnishi, T., Tamai, I., Sakanaka, K., Sakata, A., Yamashima, T., Yamashita, J., & Tsuji, A. (1995) · Biochemical Pharmacology · doi:10.1016/0006-2952(95)00082-b · Cited by 141
Reliable permeability assay system in a microfluidic device mimicking cerebral vasculatures
Yeon, J. H., Na, D., Choi, K., Ryu, S., Choi, C., & Park, J. (2012) · Biomedical Microdevices · doi:10.1007/s10544-012-9680-5 · Cited by 140
Brain microvascular endothelial cells resist elongation due to curvature and shear stress
Ye, M., Sanchez, H., Hultz, M., Yang, Z., Bogorad, M. I., Wong, A. D., & Searson, P. C. (2014) · Scientific Reports · doi:10.1038/srep04681 · Cited by 139
Booth, R., & Kim, H. (2014) · Annals of Biomedical Engineering · doi:10.1007/s10439-014-1086-5 · Cited by 125
Dudek, S. M., Chiang, E. T., Camp, S. M., Guo, Y., Zhao, J., Brown, M. E., Singleton, P. A., Wang, L., Desai, A., Arce, F. T., et al. (2010) · Molecular Biology of the Cell · doi:10.1091/mbc.e09-10-0876 · Cited by 110
Guo, D., Chien, S., & Shyy, J. Y.-J. (2007) · Circulation Research · doi:10.1161/01.res.0000259561.23876.c5 · Cited by 107
Human brain microvascular endothelial cells resist elongation due to shear stress
Reinitz, A. D., DeStefano, J. G., Ye, M., Wong, A. D., & Searson, P. C. (2015) · Microvascular Research · doi:10.1016/j.mvr.2015.02.008 · Cited by 103
Regulation of endothelial barrier function during flow-induced conversion to an arterial phenotype
Seebach, J. D., Donnert, G., Kronstein, R., WERTH, S., Wójciak‐Stothard, B., Falzarano, D., Mrowietz, C., Hell, S. W., & Schnittler, H.-J. (2007) · Cardiovascular Research · doi:10.1016/j.cardiores.2007.04.017 · Cited by 98
Shi, L., Zeng, M., Sun, Y., & Fu, B. M. (2013) · Journal of Biomechanical Engineering · doi:10.1115/1.4025892 · Cited by 93
Sutherland, M. L., Fabre, K. M., & Tagle, D. A. (2013) · Stem Cell Research & Therapy · doi:10.1186/scrt361 · Cited by 83
Shawahna, R., Declèves, X., & Scherrmann, J. (2012) · Current Drug Metabolism · doi:10.2174/1389200211309010120 · Cited by 78
Kuntz, M., Mysiorek, C., Pétrault, O., Pétrault, M., Uzbekov, R. E., Bordet, R., Fénart, L., Cecchelli, R., & Bérézowski, V. (2013) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2013.169 · Cited by 65
Shawahna, R., Declèves, X., & Scherrmann, J. (2012) · Current Drug Metabolism · doi:10.2174/138920013804545232 · Cited by 61
Cantrill, C., Skinner, R. A., Rothwell, N. J., & Penny, J. I. (2012) · Brain Research · doi:10.1016/j.brainres.2012.08.031 · Cited by 59
Cramer, S. (2014) · Journal of Nanomedicine & Nanotechnology · doi:10.4172/2157-7439.1000225 · Cited by 28
Transport of Arylsulfatase A across the Blood-Brain Barrier in Vitro
Matthes, F., Wölte, P., Böckenhoff, A., Hüwel, S., Schulz, M., Hydén, P., Fogh, J. M., Gieselmann, V., Galla, H., & Matzner, U. (2011) · Journal of Biological Chemistry · doi:10.1074/jbc.m110.189381 · Cited by 25
Graf, J. F., Scholz, B. J., & Zavodszky, M. I. (2011) · Journal of Pharmacokinetics and Pharmacodynamics · doi:10.1007/s10928-011-9229-x · Cited by 25
Claudin-5 Expression in In Vitro Models of the Blood–Brain Barrier
Cooper, I., Malina, K. C.-K., & Teichberg, V. I. (2011) · Methods in molecular biology · doi:10.1007/978-1-61779-185-7_25 · Cited by 20
Cited by
Modelling cancer in microfluidic human organs-on-chips
Sontheimer-Phelps, A., Hassell, B. A., & Ingber, D. E. (2019) · Nature Reviews Cancer · doi:10.1038/s41568-018-0104-6 · Cited by 906
Campisi, M., Shin, Y., Osaki, T., Hajal, C., Chiono, V., & Kamm, R. D. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.07.014 · Cited by 718
Organ-on-a-chip: recent breakthroughs and future prospects
Wu, Q., Liu, J., Wang, X., Feng, L., Wu, J., Zhu, X., Wen, W., & Gong, X. (2020) · BioMedical Engineering OnLine · doi:10.1186/s12938-020-0752-0 · Cited by 701
Organs-on-a-Chip: A Fast Track for Engineered Human Tissues in Drug Development
Ronaldson-Bouchard, K., & Vunjak-Novakovic, G. (2018) · Cell Stem Cell · doi:10.1016/j.stem.2018.02.011 · Cited by 657
Vatine, G. D., Barrile, R., Workman, M. J., Sances, S., Barriga, B. K., Rahnama, M., Barthakur, S., Kasendra, M., Lucchesi, C., Kerns, J., et al. (2019) · Cell stem cell · doi:10.1016/j.stem.2019.05.011 · Cited by 632
Metadata
- Authors
- Wang, Y. I., Abaci, H. E., & Shuler, M. L.
- Venue
- Biotechnology and Bioengineering
- Publisher
- Wiley
- Published
- 2016-07-21
- Volume
- 114
- Issue
- 1
- Pages
- 184-194
- ISSN
- 0006-3592 (ISSN-L)
- 1097-0290
- OpenAlex
- W2501779583
- Cited by
- 563
- References
- 71
- FWCI
- 22.86
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.