The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Near infrared optical tomography using NIRFAST: Algorithm for numerical model and image reconstruction
Open accessAbstract
Diffuse optical tomography, also known as near infrared tomography, has been under investigation, for non‐invasive functional imaging of tissue, specifically for the detection and characterization of breast cancer or other soft tissue lesions. Much work has been carried out for accurate modeling and image reconstruction from clinical data. NIRFAST, a modeling and image reconstruction package has been developed, which is capable of single wavelength and multi‐wavelength optical or functional imaging from measured data. The theory behind the modeling techniques as well as the image reconstruction algorithms is presented here, and 2D and 3D examples are presented to demonstrate its capabilities. The results show that 3D modeling can be combined with measured data from multiple wavelengths to reconstruct chromophore concentrations within the tissue. Additionally it is possible to recover scattering spectra, resulting from the dominant Mie‐type scatter present in tissue. Overall, this paper gives a comprehensive over view of the modeling techniques used in diffuse optical tomographic imaging, in the context of NIRFAST software package. Copyright © 2008 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A method for the solution of certain non-linear problems in least squares
Levenberg, K. (1944) · Quarterly of Applied Mathematics · doi:10.1090/qam/10666 · Cited by 12,359
Biomechanics. Mechanical Properties of Living Tissues
Fung, Y. C., & Skalak, R. (1982) · Journal of Applied Mechanics · doi:10.1115/1.3162171 · Cited by 6,025
A generalized inverse for matrices
Penrose, R. (1955) · Mathematical Proceedings of the Cambridge Philosophical Society · doi:10.1017/s0305004100030401 · Cited by 4,551
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899
Optical tomography in medical imaging
Arridge, S. R. (1999) · Inverse Problems · doi:10.1088/0266-5611/15/2/022 · Cited by 2,524
Elastic Moduli of Breast and Prostate Tissues under Compression
Krouskop, T. A., Wheeler, T. M., Kallel, F., Garra, B. S., & Hall, T. (1998) · Ultrasonic Imaging · doi:10.1177/016173469802000403 · Cited by 1,703
Farrell, T. J., Patterson, M. S., & Wilson, B. (1992) · Medical Physics · doi:10.1118/1.596777 · Cited by 1,378
Recent advances in diffuse optical imaging
Gibson, A. P., Hebden, J. C., & Arridge, S. R. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/4/r01 · Cited by 1,114
Light scattering in lntralipid-10% in the wavelength range of 400–1100 nm
van Staveren, H. J., Moes, C. J. M., van Marie, J., Prahl, S. A., & van Gemert, M. J. C. (1991) · Applied Optics · doi:10.1364/ao.30.004507 · Cited by 1,106
FLUORESCENCE MOLECULAR IMAGING
Ntziachristos, V. (2006) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095831 · Cited by 731
A finite element approach for modeling photon transport in tissue
Arridge, S. R., Schweiger, M., Hiraoka, M., & Delpy, D. T. (1993) · Medical Physics · doi:10.1118/1.597069 · Cited by 635
Mourant, J. R., Fuselier, T., Boyer, J., Johnson, T. M., & Bigio, I. J. (1997) · Applied Optics · doi:10.1364/ao.36.000949 · Cited by 529
EIT reconstruction algorithms: pitfalls, challenges and recent developments
Lionheart, W. R. B. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/1/021 · Cited by 447
EIT reconstruction algorithms: pitfalls, challenges and recent developmentsPreprint
Lionheart, W. R. B. (2004) · Cited by 386
Retinotopic mapping of adult human visual cortex with high-density diffuse optical tomography
Zeff, B. W., White, B. R., Dehghani, H., Schlaggar, B. L., & Culver, J. P. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0611266104 · Cited by 351
Self-citationNonuniqueness in diffusion-based optical tomography
Arridge, S. R., & Lionheart, W. R. B. (1998) · Optics Letters · doi:10.1364/ol.23.000882 · Cited by 336
Photon-measurement density functions Part 2: Finite-element-method calculations
Arridge, S. R., & Schweiger, M. (1995) · Applied Optics · doi:10.1364/ao.34.008026 · Cited by 310
Choe, R., Corlu, A., Lee, K., Durduran, T., Konecky, S. D., Grosicka‐Koptyra, M., Arridge, S. R., Czerniecki, B. J., Fraker, D. L., DeMichele, A., et al. (2005) · Medical Physics · doi:10.1118/1.1869612 · Cited by 295
Three-dimensional optical tomography of the premature infant brain
Hebden, J. C., Gibson, A., Yusof, R. M., Everdell, N., Hillman, E. M. C., Delpy, D. T., Arridge, S. R., Austin, T., Meek, J. H., & Wyatt, J. S. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/23/303 · Cited by 288
Dehghani, H., Pogue, B. W., Poplack, S. P., & Paulsen, K. D. (2003) · Applied Optics · doi:10.1364/ao.42.000135 · Cited by 274
Self-citationSrinivasan, S., Pogue, B. W., Jiang, S., Dehghani, H., Kogel, C., Soho, S., Gibson, J. J., Tosteson, T. D., Poplack, S. P., & Paulsen, K. D. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2032822100 · Cited by 267
Self-citationPogue, B. W., Jiang, S., Dehghani, H., Kogel, C., Soho, S., Srinivasan, S., Song, X., Tosteson, T. D., Poplack, S. P., & Paulsen, K. D. (2004) · Journal of Biomedical Optics · doi:10.1117/1.1691028 · Cited by 197
Self-citationBoas, D. A., Chen, K., Grebert, D., & Franceschini, M. A. (2004) · Optics Letters · doi:10.1364/ol.29.001506 · Cited by 166
Hueber, D. M., Franceschini, M. A., Ma, H. Y., Zhang, Q., Ballesteros, J. R., Fantini, S., Wallace, D., Ntziachristos, V, & Chance, B. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/1/304 · Cited by 158
Yalavarthy, P. K., Pogue, B. W., Dehghani, H., & Paulsen, K. D. (2007) · Medical Physics · doi:10.1118/1.2733803 · Cited by 156
Self-citationTime resolved optical tomography of the human forearm
Hillman, E. M. C., Hebden, J. C., Schweiger, M. J., Dehghani, H., Schmidt, F. E. W., Delpy, D. T., & Arridge, S. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/4/315 · Cited by 149
Self-citationMcBride, T. O., Pogue, B. W., Gerety, E. D., Poplack, S. P., Österberg, U. L., & Paulsen, K. D. (1999) · Applied Optics · doi:10.1364/ao.38.005480 · Cited by 144
Self-citationRainbow three-dimensional camera: new concept of high-speed three-dimensional vision systems
Geng, Z. J. (1996) · Optical Engineering · doi:10.1117/1.601023 · Cited by 135
Volumetric tomography of fluorescent proteins through small animals in vivo
Zacharakis, G., Kambara, H., Shih, H. A., Ripoll, J., Grimm, J., Saeki, Y., Weissleder, R., & Ntziachristos, V. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0504628102 · Cited by 118
Near-Infrared Characterization of Breast Tumors In Vivo using Spectrally-Constrained Reconstruction
Srinivasan, S., Pogue, B. W., Brooksby, B. A., et al. (2005) · Technology in Cancer Research & Treatment · doi:10.1177/153303460500400505 · Cited by 117
Self-citationPoplack, S. P., Paulsen, K. D., Hartov, A., et al. (2004) · Radiology · doi:10.1148/radiol.2312030606 · Cited by 116
Self-citationThree-dimensional optical tomographic imaging of breast in a human subject
Jiang, H., Xu, Y., Iftimia, N. V., et al. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.974928 · Cited by 113
Continuous-wave diffusion imaging
Schotland, J. C. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.000275 · Cited by 107
Recovery of optical parameters in multiple-layered diffusive media: theory and experiments
Ripoll, J., Ntziachristos, V., Culver, J. P., Pattanayak, D. N., Yodh, A. G., & Nieto‐Vesperinas, M. (2001) · Journal of the Optical Society of America A · doi:10.1364/josaa.18.000821 · Cited by 64
Spectral priors improve near-infrared diffuse tomography more than spatial priors
Brooksby, B. A., Srinivasan, S., Jiang, S., Dehghani, H., Pogue, B. W., Paulsen, K. D., Weaver, J. B., Kogel, C. A., & Poplack, S. P. (2005) · Optics Letters · doi:10.1364/ol.30.001968 · Cited by 64
Self-citationContrast-detail analysis characterizing diffuse optical fluorescence tomography image reconstruction
Davis, S. C., Pogue, B. W., Dehghani, H., & Paulsen, K. D. (2005) · Journal of Biomedical Optics · doi:10.1117/1.2114727 · Cited by 54
Self-citationOxygen Transport to Tissue XXI
Eke, A., & Delpy, D. T. (1999) · Advances in experimental medicine and biology · doi:10.1007/978-1-4615-4717-4 · Cited by 33
Leung, T. S., Tachtsidis, I., Smith, M., Delpy, D. T., & Elwell, C. E. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/3/015 · Cited by 20
Cited by
Scholkmann, F., Kleiser, S., Metz, A. J., Zimmermann, R., Mata Pavia, J., Wolf, U., & Wolf, M. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.004 · Cited by 2,002
Diffuse optics for tissue monitoring and tomography
Durduran, T., Choe, R., Baker, W. B., & Yodh, A. G. (2010) · Reports on Progress in Physics · doi:10.1088/0034-4885/73/7/076701 · Cited by 1,161
Mapping distributed brain function and networks with diffuse optical tomography
Eggebrecht, A. T., Ferradal, S. L., Robichaux-Viehoever, A., Hassanpour, M. S., Dehghani, H., Snyder, A. Z., Hershey, T., & Culver, J. P. (2014) · Nature Photonics · doi:10.1038/nphoton.2014.107 · Cited by 596
Self-citationBest practices for fNIRS publications
Yücel, M. A., Lühmann, A. V., Scholkmann, F., Gervain, J., Dan, I., Ayaz, H., Boas, D., Cooper, R. J., Culver, J., Elwell, C. E., et al. (2021) · Neurophotonics · doi:10.1117/1.nph.8.1.012101 · Cited by 492
The NIRS Brain AnalyzIR Toolbox
Santosa, H., Zhai, X., Fishburn, F., & Huppert, T. (2018) · Algorithms · doi:10.3390/a11050073 · Cited by 440
Metadata
- Authors
- Dehghani, H., Eames, M. E., Yalavarthy, P. K., Davis, S. C., Srinivasan, S., Carpenter, C. M., Pogue, B. W., & Paulsen, K. D.
- Venue
- Communications in Numerical Methods in Engineering
- Publisher
- Wiley
- Published
- 2008-08-15
- Volume
- 25
- Issue
- 6
- Pages
- 711-732
- ISSN
- 1069-8299 (ISSN-L)
- 1099-0887
- OpenAlex
- W2007492138
- Cited by
- 728
- References
- 38
- FWCI
- 16.49
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.