Hypoglycaemia detection and prediction techniques: A systematic review on the latest developments
Open accessThe DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
The main objective of diabetes control is to correct hyperglycaemia while avoiding hypoglycaemia, especially in insulin‐treated patients. Fear of hypoglycaemia is a hurdle to effective correction of hyperglycaemia because it promotes under‐dosing of insulin. Strategies to minimise hypoglycaemia include education and training for improved hypoglycaemia awareness and the development of technologies to allow their early detection and thus minimise their occurrence. Patients with impaired hypoglycaemia awareness would benefit the most from these technologies. The purpose of this systematic review is to review currently available or in‐development technologies that support detection of hypoglycaemia or hypoglycaemia risk, and identify gaps in the research. Nanomaterial use in sensors is a promising strategy to increase the accuracy of continuous glucose monitoring devices for low glucose values. Hypoglycaemia is associated with changes on vital signs, so electrocardiogram and encephalogram could also be used to detect hypoglycaemia. Accuracy improvements through multivariable measures can make already marketed galvanic skin response devices a good noninvasive alternative. Breath volatile organic compounds can be detected by dogs and devices and alert patients at hypoglycaemia onset, while near‐infrared spectroscopy can also be used as a hypoglycaemia alarms. Finally, one of the main directions of research are deep learning algorithms to analyse continuous glucose monitoring data and provide earlier and more accurate prediction of hypoglycaemia. Current developments for early identification of hypoglycaemia risk combine improvements of available ‘needle‐type’ enzymatic glucose sensors and noninvasive alternatives. Patient usability will be essential to demonstrate to allow their implementation for daily use in diabetes management.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
International consensus on use of continuous glucose monitoring
Danne, T., Nimri, R., Battelino, T., Bergenstal, R. M., Close, K. L., DeVries, J. H., Garg, S., Heinemann, L., Hirsch, I., Amiel, S. A., et al. (2017) · Diabetes Care · doi:10.2337/dc17-1600 · Cited by 2,069 · cited 1×
“glucose levels, devices used and the impact of hypoglycaemia on the person with diabetes.(1,4,5) Alongside these differences in glucose thresholds to define hypoglycaemia, there are huge inter—as well as intraindividual variations in the glucose levels at which hypoglycaemic events are experienced.”
BackgroundQuantitative estimation of insulin sensitivity.
Bergman, R. N., Ider, Y. Z., Bowden, C. R., & Cobelli, C. (1979) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1979.236.6.e667 · Cited by 1,874
Electrochemical Glucose Sensors and Their Applications in Diabetes Management
Heller, A., & Feldman, B. (2008) · Chemical Reviews · doi:10.1021/cr068069y · Cited by 1,707 · cited 1×
“(Se), the good linearity between the current and glucose level, and their range of detection going from 2 mmol/L (40 mg/dl) up to 40 mmol/L (400 mg/dl).(9) However, at the extremities of the range of detection, these sensors suffer from a reduction of accuracy, with an”
BackgroundNonlinear model predictive control of glucose concentration in subjects with type 1 diabetes
Hovorka, R., Canonico, V., Chassin, L. J., Haueter, U., Massi-Benedetti, M., Federici, M. O., Pieber, T. R., Schaller, H. C., Schaupp, L., Vering, T., et al. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/4/010 · Cited by 1,274
Recent advances in electrochemical non-enzymatic glucose sensors – A review
Hwang, D.-W., Lee, S., Seo, M., & Chung, T. D. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.05.051 · Cited by 788
Parkes, J. L., Slatin, S. L., Pardo, S., & Ginsberg, B. H. (2000) · Diabetes Care · doi:10.2337/diacare.23.8.1143 · Cited by 620
International Hypoglycaemia Study Group (2017) · Diabetes Care · doi:10.2337/dc16-2215 · Cited by 608
Cappon, G., Vettoretti, M., Sparacino, G., & Facchinetti, A. (2019) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2019.0121 · Cited by 477
Seaquist, E. R., Anderson, J., Childs, B., Cryer, P., Dagogo-Jack, S., Fish, L., Heller, S. R., Rodriguez, H., Rosenzweig, J., & Vigersky, R. (2013) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2012-4127 · Cited by 412 · cited 2×
“(PwD) in daily life, as it can result in symptoms that affect their mental agility and can lead to coma if not treated rapidly.(1) Psycho-”
BackgroundBoyle, P. J., Schwartz, N. S., Shah, S. D., Clutter, W. E., & Cryer, P. E. (1988) · New England Journal of Medicine · doi:10.1056/nejm198806093182302 · Cited by 258
Robinson, R. T. C. E., Harris, N. D., Ireland, R. H., Macdonald, I. A., & Heller, S. R. (2004) · Diabetologia · doi:10.1007/s00125-003-1292-4 · Cited by 137
Electrocardiographic Alterations during Hyperinsulinemic Hypoglycemia in Healthy Subjects
Laitinen, T., Lyyra‐Laitinen, T., Huopio, H., Vauhkonen, I., Halonen, T., Hartikainen, J., Niskanen, L., & Laakso, M. (2008) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2008.00208.x · Cited by 107
Cichosz, S. L., Frystyk, J., Hejlesen, O. K., Tarnow, L., & Fleischer, J. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814528838 · Cited by 88
Prediction and prevention of hypoglycaemic events in type-1 diabetic patients using machine learning
Vehí, J., Contreras, I., Oviedo, S., Biagi, L., & Bertachi, A. (2020) · Health Informatics Journal · doi:10.1177/1460458219850682 · Cited by 76
Prediction of hypoglycemia during aerobic exercise in adults with type 1 diabetes
Reddy, R., Resalat, N., Wilson, L. M., Castle, J. R., El Youssef, J., & Jacobs, P. G. (2019) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818823792 · Cited by 75
Zecchin, C., Facchinetti, A., Sparacino, G., & Cobelli, C. (2016) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816654161 · Cited by 64
Improved Real-World Glycemic Control With Continuous Glucose Monitoring System Predictive Alerts
Abraham, S. B., Arunachalam, S., Zhong, A., Agrawal, P., Cohen, O., & McMahon, C. M. (2021) · Journal of Diabetes Science and Technology · doi:10.1177/1932296819859334 · Cited by 63
Non-invasive hypoglycemia monitoring system using extreme learning machine for Type 1 diabetes
Ling, S. H., San, P. P., & Nguyen, H. T. (2016) · ISA Transactions · doi:10.1016/j.isatra.2016.05.008 · Cited by 62
Olde Bekkink, M., Koeneman, M., de Galan, B. E., & Bredie, S. J. (2019) · Diabetes Care · doi:10.2337/dc18-1843 · Cited by 58
Hypoglycaemia and its management in primary care setting
Ibrahim, M., Baker, J., Cahn, A., Eckel, R. H., El Sayed, N. A., Fischl, A. H., Gaede, P., Leslie, R. D., Pieralice, S., Tuccinardi, D., et al. (2020) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.3332 · Cited by 21
Cited by
Six Digital Health Technologies That Will Transform Diabetes
Klonoff, A. N., Lee, W.-A. (., Xu, N. Y., Nguyen, K. T., DuBord, A., & Kerr, D. (2023) · Journal of Diabetes Science and Technology · doi:10.1177/19322968211043498 · Cited by 44
Identifying the deficiencies of currently available CGM to improve uptake and benefit
Barnard‐Kelly, K. D., Martínez‐Brocca, M. A., Glatzer, T., & Oliver, N. (2024) · Diabetic Medicine · doi:10.1111/dme.15338 · Cited by 37
“40 This would enable the user to take preventive action while still awake and support an uninterrupted, restful sleep, resulting in an improvement in the fear of nocturnal hypoglycaemia.”
InfluentialGiza, S., Kotanidou, E. P., Tsinopoulou, V. R., Poukoulidou, T., Ntouma, S., & Galli-Tsinopoulou, A. (2025) · Children · doi:10.3390/children12121668 · Cited by 7
“The development of algorithms may serve in this context [16], for learning individual glucose profiles and providing earlier and more accurate prediction of glucose levels, focused on hypoglycemia [33,73,74].”
Metadata
- Authors
- Diouri, O., Cigler, M., Vettoretti, M., Mader, J. K., Choudhary, P., Renard, E., & HYPO‐RESOLVE Consortium
- Venue
- Diabetes/Metabolism Research and Reviews
- Publisher
- Wiley
- Published
- 2021-03-24
- Volume
- 37
- Issue
- 7
- Pages
- e3449-e3449
- ISSN
- 1520-7552 (ISSN-L)
- 1520-7560
- OpenAlex
- W3137461132
- Cited by
- 50
- References
- 20
- FWCI
- 2.22
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.