CoChat

Comprehensive analysis of host cell impurities in monoclonal antibodies with improved sensitivity by capillary zone electrophoresis mass spectrometry

The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.

Abstract

Four methods were compared for analysis of host‐cell protein (HCP) impurities in a recombinant mAb. First, CZE‐MS/MS was used to analyze the digest of an HCP sample following extraction of the mAb with proteins A and L affinity columns; 220 protein groups and 976 peptides were identified from the depleted HCP digest. Second, a nanoACQUITY UltraPerformance LCH system was also used to analyze the depleted HCP digest; 34 protein groups and 53 peptides from 50 ng of the depleted HCP digest and 290 protein groups and 1011 peptides were identified from 1 μg of the depleted HCP digest. Third, 185 protein groups and 709 peptides were identified by CZE‐MS/MS from the HCP digest without depletion. Fourth, a strong cation exchange SPE was coupled to CZE‐ESI‐MS/MS using online pH gradient elution for analysis of the HCP digest without depletion. A series of five pH bumps were applied to elute peptides from the strong cation exchange monolith followed by analysis using CZE coupled to a Q Exactive HF mass spectrometer; 230 protein groups and 796 peptides were identified from the HCP digest without depletion.

Overview

Integrity signals

Registry

Crossref · 10.1002/elps.201600390

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Research works printed but not linked: 1

  1. Savino E., 2011, BioProcess Intl, 9, 38

Cited by

See all 23

Metadata

Authors
Zhang, Z., Albanetti, T., Linkous, T., Larkin, C. J., Schoner, R., McGivney, J. B., & Dovichi, N. J.
Affiliations
  • University of Notre Dame (US)
  • BioPharmaceutical Development, MedImmune LLC One MedImmune Way Gaithersburg MD USA
  • Department of Chemistry and Biochemistry University of Notre Dame Notre Dame IN USA
Venue
ELECTROPHORESIS
Publisher
Wiley
Published
2016-12-14
Volume
38
Issue
3-4
Pages
401-407
ISSN
  • 0173-0835 (ISSN-L)
  • 1522-2683
OpenAlex
W2552178166
Cited by
23
References
27
Citations by year
2026: 1 · 2023: 3 · 2022: 4 · 2021: 3 · 2020: 1 · 2019: 4 · 2018: 4 · 2017: 3
FWCI
1.82
Type
journal article
Language
en
Open access
closed
Locations
  • Electrophoresis (publishedVersion)
  • PubMed (publishedVersion)
Funders
MedImmune
Topics
  • Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
  • Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
Keywords
monoclonal antibodies, capillary zone electrophoresis-mass spectrometry, peptide identification, affinity chromatography, method comparison
MeSH terms
Animals, Antibodies, Monoclonal, Chromatography, High Pressure Liquid, Cricetulus, Cricetinae, Peptide Fragments, CHO Cells, Electrophoresis, Capillary, Proteomics, Solid Phase Extraction, Tandem Mass Spectrometry

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.