The DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.
Monte Carlo simulation studies of EEG and MEG localization accuracy
Open accessAbstract
Both electroencephalography (EEG) and magnetoencephalography (MEG) are currently used to localize brain activity. The accuracy of source localization depends on numerous factors, including the specific inverse approach and source model, fundamental differences in EEG and MEG data, and the accuracy of the volume conductor model of the head (i.e., the forward model). Using Monte Carlo simulations, this study removes the effect of forward model errors and theoretically compares the use of EEG alone, MEG alone, and combined EEG/MEG data sets for source localization. Here, we use a linear estimation inverse approach with a distributed source model and a realistic forward head model. We evaluated its accuracy using the crosstalk and point spread metrics. The crosstalk metric for a specified location on the cortex describes the amount of activity incorrectly localized onto that location from other locations. The point spread metric provides the complementary measure: for that same location, the point spread describes the mis‐localization of activity from that specified location to other locations in the brain. We also propose and examine the utility of a “noise sensitivity normalized” inverse operator. Given our particular forward and inverse models, our results show that 1) surprisingly, EEG localization is more accurate than MEG localization for the same number of sensors averaged over many source locations and orientations; 2) as expected, combining EEG with MEG produces the best accuracy for the same total number of sensors; 3) the noise sensitivity normalized inverse operator improves the spatial resolution relative to the standard linear estimation operator; and 4) use of an a priori fMRI constraint universally reduces both crosstalk and point spread. Hum. Brain Mapping 16:47–62, 2002. © 2002 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cortical Surface-Based Analysis
Dale, A. M., Fischl, B., & Sereno, M. I. (1999) · NeuroImage · doi:10.1006/nimg.1998.0395 · Cited by 10,910
Self-citationSolutions of Ill-Posed Problems.
Bell, J. B., Tikhonov, A. N., & Arsenin, V. Y. (1978) · Mathematics of Computation · doi:10.2307/2006360 · Cited by 8,101
GELB, A. (1974) · CERN Document Server (European Organization for Nuclear Research) · Cited by 6,405
Cortical Surface-Based Analysis
Fischl, B., Sereno, M. I., & Dale, A. M. (1999) · NeuroImage · doi:10.1006/nimg.1998.0396 · Cited by 6,147
Self-citationPascual-Marqui, R. D., Michel, C. M., & Lehmann, D. (1994) · International Journal of Psychophysiology · doi:10.1016/0167-8760(84)90014-x · Cited by 2,869
Geophysical data analysis : discrete inverse theory
Menke, W. H. (1989) · Cited by 2,843
Dale, A. M., & Sereno, M. I. (1993) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.1993.5.2.162 · Cited by 2,003
Self-citationDynamic Statistical Parametric Mapping
Dale, A. M., Liu, A. K., Fischl, B. R., Buckner, R. L., Belliveau, J. W., Lewine, J. D., & Halgren, E. (2000) · Neuron · doi:10.1016/s0896-6273(00)81138-1 · Cited by 1,787
Self-citationUniqueness in the inversion of inaccurate gross Earth data
Backus, G., & Gilbert, F. (1970) · Philosophical Transactions of the Royal Society of London. Series A, Mathematical and Physical Sciences · doi:10.1098/rsta.1970.0005 · Cited by 1,336
Geophysical Data Analysis: Discrete Inverse Theory
(1989) · International Geophysics · doi:10.1016/s0074-6142(08)x6008-5 · Cited by 1,291
Realistic conductivity geometry model of the human head for interpretation of neuromagnetic data
Hamalainen, M. S., & Sarvas, J. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.16463 · Cited by 989
Liu, A. K., Belliveau, J. W., & Dale, A. M. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.15.8945 · Cited by 384
Self-citationA study of dipole localization accuracy for MEG and EEG using a human skull phantom
Leahy, R. M., Mosher, J. C., Spencer, M. E., Huang, M. X., & Lewine, J. D. (1998) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(98)00057-1 · Cited by 383
On the numerical accuracy of the boundary element method (EEG application)
Meijs, J. W. H., Weier, O. W., Peters, M. J., & Van Oosterom, A. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.40805 · Cited by 305
MEG versus EEG localization test using implanted sources in the human brain
Cohen, D., Cuffin, B. N., Yunokuchi, K., Maniewski, R., Purcell, C., Cosgrove, G. R., Ives, J., Kennedy, J. G., & Schomer, D. L. (1990) · Annals of Neurology · doi:10.1002/ana.410280613 · Cited by 294
Improving source reconstructions by combining bioelectric and biomagnetic data
Fuchs, M., Wagner, M., Wischmann, H.-A., Köhler, T., Theißen, A., Drenckhahn, R., & Buchner, H. (1998) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(98)00046-7 · Cited by 239
Error bounds for EEG and MEG dipole source localization
Mosher, J. C., Spencer, M. E., Leahy, R. M., & Lewis, P. S. (1993) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(93)90043-u · Cited by 233
Source parameter estimation in inhomogeneous volume conductors of arbitrary shape
Oostendorp, T. F., & van Oosterom, A. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.19859 · Cited by 226
Magnetic localization of neuronal activity in the human brain.
Yamamoto, T., Williamson, S. J., Kaufman, L., Nicholson, C., & Llinás, R. (1988) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.85.22.8732 · Cited by 205
The magnetic and electric fields agree with intracranial localizations of somatosensory cortex
Sutherling, W. W., Crandall, P. H., Darcey, T. M., Becker, D. P., Levesque, M. F., & Barth, D. S. (1988) · Neurology · doi:10.1212/wnl.38.11.1705 · Cited by 201
Comparisons of MEG, EEG, and ECoG source localization in neocortical partial epilepsy in humans
Nakasatp, N., Levesque, M. F., Barth, D. S., Baumgartner, C., Rogers, R. L., & Sutherling, W. W. (1994) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)90067-1 · Cited by 194
de Munck, J. C. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.256433 · Cited by 193
Mikuni, N., Nagamine, T., Ikeda, A., Terada, K., Taki, W., Kimura, J., Kikuchi, H., & Shibasaki, H. (1997) · NeuroImage · doi:10.1006/nimg.1997.0272 · Cited by 190
MEG-based imaging of focal neuronal current sources
Phillips, J. W., Leahy, R. M., & Mosher, J. C. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.585768 · Cited by 190
Spatial resolution of neuromagnetic records: theoretical calculations in a spherical model
Hari, R., Joutsiniemi, S.-L., & Sarvas, J. (1988) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(88)90020-2 · Cited by 181
A critical analysis of linear inverse solutions to the neuroelectromagnetic inverse problem
De Peralta-Menendez, R. G., & Gonzalez-Andino, S. L. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.664200 · Cited by 175
The influence of model parameters on EEG/MEG single dipole source estimation
Stok, C. J. (1987) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1987.326090 · Cited by 172
Supek, S., & Aine, C. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.237672 · Cited by 153
Effects of head shape on EEGs and MEGs
Cuffin, B. N. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.43614 · Cited by 153
The localization of equivalent dipoles of EEG sources by the application of electrical field theory
Henderson, C. J., Butler, S. R., & Glass, A. (1975) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(75)90002-4 · Cited by 150
Sensitivity distributions of EEG and MEG measurements
Malmivuo, J. A., Suihko, V., & Eskola, H. J. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.554766 · Cited by 150
EEG localization accuracy improvements using realistically shaped head models
Cuffin, B. N. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.486287 · Cited by 137
Lantz, G., Michel, C. M., Pascual-Marqui, R. D., Spinelli, L., Seeck, M., Seri, S., Landis, T., & Rosén, I. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0921-884x(96)96551-0 · Cited by 136
Magnetic localization of a dipolar current source implanted in a sphere and a human cranium
Barth, D. S., Sutherling, W. W., Broffman, J., & Beatty, J. (1986) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(86)90094-5 · Cited by 128
Linear inverse solutions with optimal resolution kernels applied to electromagnetic tomography
Menéndez, R. G. D. P., Hauk, O., Andino, S. L. G., Vogt, H. J., & Michel, C. M. (1997) · Human Brain Mapping · Cited by 125
Tests of EEG localization accuracy using implanted sources in the human brain
Cuffin, B. N., Cohen, D., Yunokuchi, K., Maniewski, R., Purcell, C., Cosgrove, G. R., Ives, J. R., Kennedy, J. G., & Schomer, D. L. (1991) · Annals of Neurology · doi:10.1002/ana.410290204 · Cited by 124
The magnetic field of complex partial seizures agrees with intracranial localizations
Sutherling, W. W., Crandall, P. H., Engel, J., Darcey, T. M., Cahan, L. D., & Barth, D. S. (1987) · Annals of Neurology · doi:10.1002/ana.410210605 · Cited by 115
Meijs, J. W. H., Bosch, F. G. C., Peters, M. J., & Lopes, F. H. D. S. (1987) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(87)90078-2 · Cited by 101
A 122-channel whole-cortex SQUID system for measuring the brain's magnetic fields
Knuutila, J., Ahonen, A., Hämäläinen, M., Kajola, M., Laine, P. P., Lounasmaa, O. V., Parkkonen, L. T., Simola, J., & Tesche, C. D. (1993) · IEEE Transactions on Magnetics · doi:10.1109/20.281163 · Cited by 96
Sekihara, K., & Scholz, B. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.486285 · Cited by 86
Accuracy of EEG dipole source localization using implanted sources in the human brain
Krings, T., Chiappa, K. H., Cuffin, B. N., et al. (1999) · Clinical Neurophysiology · doi:10.1016/s0013-4694(98)00106-0 · Cited by 75
Localisation of epileptic foci with electric, magnetic and combined electromagnetic models
Diekmann, V., Becker, W., Jürgens, R., Grözinger, B., Kleiser, B., Richter, H., & Wollinsky, K. H. (1998) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(97)00142-9 · Cited by 71
Imaging neural activity using MEG and EEG
Phillips, J., Leahy, R. M., Mosher, J. C., & Timsari, B. (1997) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.585515 · Cited by 60
Dipole‐Source Analysis in a Realistic Head Model in Patients with Focal Epilepsy
Herrendorf, G., Steinhoff, B. J., Kolle, R., Baudewig, J., Waberski, T. D., Büchner, H., & Paulus, W. (2000) · Epilepsia · doi:10.1111/j.1528-1157.2000.tb01508.x · Cited by 55
Krings, T., Chiappa, K. H., Cuffin, B. N., Buchbinder, B. R., & Cosgrove, G. R. (1998) · Annals of Neurology · doi:10.1002/ana.410440114 · Cited by 51
Localization of epileptic foci using a large‐area magnetometer and functional brain anatomy
Tiihonen, J., Hari, R., Kajola, M., et al. (1990) · Annals of Neurology · doi:10.1002/ana.410270310 · Cited by 51
Ko, D., Kufta, C. V., Scaffidi, D., & Sato, S. (1998) · Neurosurgery · doi:10.1097/00006123-199802000-00142 · Cited by 49
Localization of a dipolar source in a skull phantom: realistic versus spherical model
Menninghaus, E., Lütkenhöner, B., & Gonzalez, S. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.324531 · Cited by 45
Spatial Resolution of Neuronal Generators Based on Eeg and Meg Measurements
Pascual-Marqui, R. D., & Biscay-Lirio, R. J. (1993) · International Journal of Neuroscience · doi:10.3109/00207459308994264 · Cited by 44
Figures of merit to compare distributed linear inverse solutions
Menéndez, R. G. D. P., Andino, S. L. G., & Lütkenhöner, B. (1996) · Brain Topography · doi:10.1007/bf01200711 · Cited by 41
Sekihara, K., & Scholz, B. (1995) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.341827 · Cited by 38
Lütkenhöner, B., & Menendez, R. G. D. P. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(96)96590-6 · Cited by 25
Smith, W. E. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.161331 · Cited by 19
Cited by
Fischl, B. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.01.021 · Cited by 9,526
Review on solving the inverse problem in EEG source analysis
Grech, R., Cassar, T., Muscat, J., Camilleri, K. P., Fabri, S. G., Zervakis, M., Xanthopoulos, P., Sakkalis, V., & Vanrumste, B. (2008) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-5-25 · Cited by 1,193
Mismatch negativity (MMN), the deviance-elicited auditory deflection, explained
May, P. J. C., & Tiitinen, H. (2010) · Psychophysiology · doi:10.1111/j.1469-8986.2009.00856.x · Cited by 549
Spatiotemporal dynamics of modality-specific and supramodal word processing
Marinkovic, K., Dhond, R. P., Dale, A. M., Glessner, M., Carr, V., & Halgren, E. (2003) · Neuron · doi:10.1016/s0896-6273(03)00197-1 · Cited by 520
Self-citationMeasuring MEG Closer to the Brain: Performance of on-Scalp Sensor Arrays
Iivanainen, J., Stenroos, M., & Parkkonen, L. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.12.048 · Cited by 296
“To evaluate the differences between the arrays in linear distributedsource estimation, we used metrics derived from the resolution matrix (Hauk et al., 2011; Liu et al., 2002; Molins et al., 2008; de Peralta Menendez et al., 1997; Stenroos and Hauk, 2013).”
Metadata
- Authors
- Liu, A. K., Dale, A. M., & Belliveau, J. W.
- Venue
- Human Brain Mapping
- Publisher
- Wiley
- Published
- 2002-02-06
- Volume
- 16
- Issue
- 1
- Pages
- 47-62
- ISSN
- 1065-9471 (ISSN-L)
- 1097-0193
- OpenAlex
- W1985582058
- Cited by
- 349
- References
- 53
- FWCI
- 8.87
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.