Reversal of Fulminant Hepatic Failure Using An Extracorporeal Liver Assist Device
Abstract
Liver transplantation is currently the only effective therapy for patients with fulminant hepatic failure. The availability of an artificial liver could bridge these patients through the relatively brief crisis period and allow their own livers to regenerate, providing a more favorable outcome and sparing the trauma and expense of transplant. We have developed a device consisting of a highly differentiated human liver cell line cultured in a hollow fiber cartridge. This device is capable of supporting dogs with acetaminopheninduced fulminant hepatic failure for a period long enough for their own livers to resume function. Even though liver function tests such as albumin and prothrombin time became extremely abnormal during the course of the experiment, the dogs did not become encephalopathic. Two of the three treated animals recovered sufficient liver function after 42 to 48 hr of treatment that they could be disconnected from the device, and they survived the experiment. Histological results and serum ALT levels suggest that the device affected the course of the disease in two animals, allowing recovery of hepatocytes that would otherwise have lysed. In the third animal, regenerative nodules demonstrated that, even in the presence of severe liver injury, the device was capable of supporting total liver function. (Hepatology 1992;16:60-65.)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dudley, R. K. (1988) · FEBS Letters · doi:10.1016/0014-5793(88)80264-3 · Cited by 5,945
Current protocols in molecular biology
(1988) · Trends in Biochemical Sciences · doi:10.1016/0968-0004(88)90131-4 · Cited by 4,160
Starzl, T. E., Demetris, A. J., & Thiel, D. V. (1989) · New England Journal of Medicine · doi:10.1056/nejm198910123211505 · Cited by 550
Controlled trials of charcoal hemoperfusion and prognostic factors in fulminant hepatic failure
O'Grady, J. G., Gimson, A. E. S., O'Brien, C. J., Pucknell, A., Hughes, R. D., & Williams, R. (1988) · Gastroenterology · doi:10.1016/0016-5085(88)90011-x · Cited by 538
Hybrid bioartificial liver in hepatic failure: preliminary clinical report.
Matsumura, K. N., Guevara, G., Huston, H. K., Hamilton, W. L., Rikimaru, M., Yamasaki, G., & Matsumura, M. S. (1987) · PubMed · Cited by 186
Modulation of the liver specific phenotype in the human hepatoblastoma line Hep G2
Kelly, J. H., & Darlington, G. (1989) · In Vitro Cellular & Developmental Biology - Plant · doi:10.1007/bf02626182 · Cited by 134
Self-citationA hybrid bioartificial liver composed of multiplated hepatocyte monolayers.
Uchino, J., Tsuburaya, T., Kumagai, F., Taiji, H. A. S. E., Hamada, T., Komai, T., Funatsu, A., Hashimura, E., Nakamura, K., & Kon, T. (1988) · PubMed · Cited by 102
Bilirubin conjugation by an artificial liver composed of cultured cells and synthetic capillaries.
Wolf, C. F. W., & Munkelt, B. E. (1975) · PubMed · Cited by 102
An improved model of acetaminophen-induced fulminant hepatic failure in dogs
Kelly, J. H., Koussayer, T., He, D.-E., Chong, M. G., Shang, T. A., Whisennand, H. H., & Sussman, N. (1992) · Hepatology · doi:10.1002/hep.1840150225 · Cited by 76
Self-citationAssessment of an Extracorporeal Liver Assist Device in Anhepatic Dogs
Kelly, J. H., Koussayer, T., He, D.-E., Chong, M. G., Shang, T. A., Whisennand, H. H., & Sussman, N. (1992) · Artificial Organs · doi:10.1111/j.1525-1594.1992.tb00543.x · Cited by 54
Self-citation
Cited by
Long-term storage of tissues by cryopreservation: critical issues
Karlsson, J. O. M., & Toner, M. (1996) · Biomaterials · doi:10.1016/0142-9612(96)85562-1 · Cited by 619
McKenzie, R., Fried, M. W., Sallie, R., Conjeevaram, H., Di Bisceglie, A. M., Park, Y., Savarese, B., Kleiner, D., Tsokos, M., Luciano, C., et al. (1995) · New England Journal of Medicine · doi:10.1056/nejm199510263331702 · Cited by 616
Lee, W. M. (1993) · New England Journal of Medicine · doi:10.1056/nejm199312163292508 · Cited by 546
Fulminant hepatic failure: Summary of a workshop
Hoofnagle, J. H., Carithers, R. L., Shapiro, C., & Ascher, N. (1995) · Hepatology · doi:10.1002/hep.1840210137 · Cited by 533
Pilot–Controlled Trial of the Extracorporeal Liver Assist Device in Acute Liver Failure
Ellis, A. J., Hughes, R. D., Wendon, J. A., Dunne, J., Langley, P. G., Kelly, J. H., Gislason, G. T., Sussman, N. L., & Williams, R. (1996) · Hepatology · doi:10.1002/hep.510240625 · Cited by 513
Self-citationMedical applications of membranes: Drug delivery, artificial organs and tissue engineering
Stamatialis, D. F., Papenburg, B. J., Gironés, M., Saiful, S., Bettahalli, S. N. M., Schmitmeier, S., & Wessling, M. (2008) · Journal of Membrane Science · doi:10.1016/j.memsci.2007.09.059 · Cited by 473
Watanabe, F. D., Mullon, C. J.-P., Hewitt, W. R., Arkadopoulos, N., Kahaku, E., Eguchi, S., Khalili, T., Arnaout, W., Shackleton, C. R., Rozga, J., et al. (1997) · Annals of Surgery · doi:10.1097/00000658-199705000-00005 · Cited by 453
Orthotopic Liver Transplantation in Fulminant and Subfulminant Hepatitis The Paul Brousse Experience
Bismuth, H., Samuel, D., Castaing, D., Adam, R., Saliba, F., Johann, M., Azoulay, D., Ducot, B., & Chiche, L. (1995) · Annals of Surgery · doi:10.1097/00000658-199508000-00002 · Cited by 321
Microfabrication of Hepatocyte/Fibroblast Co-cultures: Role of Homotypic Cell Interactions
Bhatia, S. N., Balis, U. J., Yarmush, M. L., & Toner, M. (1998) · Biotechnology Progress · doi:10.1021/bp980036j · Cited by 304
A Bioartificial Liver--State of the Art
Strain, A. J., & Neuberger, J. M. (2002) · Science · doi:10.1126/science.1068660 · Cited by 284
The Hepatix Extracorporeal Liver Assist Device: Initial Clinical Experience
Sussman, N. L., Gislason, G. T., Conlin, C. A., & Kelly, J. H. (1994) · Artificial Organs · doi:10.1111/j.1525-1594.1994.tb02221.x · Cited by 277
Self-citation(1994) · PubMed Central · Cited by 209
Liver tissue engineering and cell sources: issues and challenges
Palakkan, A. A., Hay, D. C., PR, A. K., TV, K., & Ross, J. A. (2013) · Liver International · doi:10.1111/liv.12134 · Cited by 130
Artificial liver: A forthcoming attraction
Sussman, N. L., & Kelly, J. H. (1993) · Hepatology · doi:10.1002/hep.1840170632 · Cited by 46
Self-citationArtificial Liver Support: State of the Art
Dixit, V., & Gitnick, G. (1996) · Scandinavian Journal of Gastroenterology · doi:10.3109/00365529609094760 · Cited by 42
Diekmann, S., Bader, A., & Schmitmeier, S. (2006) · Cytotechnology · doi:10.1007/s10616-006-6336-4 · Cited by 32
Metadata
- Authors
- Sussman, N. L., Chong, M. G., Koussayer, T., He, D.-E., Shang, T. A., Whisennand, H. H., & Kelly, J. H.
- Venue
- Hepatology
- Published
- 1992-07
- Volume
- 16
- Issue
- 1
- Pages
- 60-65
- ISSN
- 0270-9139 (ISSN-L)
- OpenAlex
- W2062602912
- Cited by
- 345
- References
- 10
- FWCI
- 10.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.