Enhanced coagulation for arsenic removal
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Preliminary bench‐ and pilot‐scale investigations showed that coagulation is a promising treatment for removing arsenic from drinking water but that further work is needed, primarily on full‐scale plants. The possible use of enhanced coagulation for arsenic removal was examined at the facilities of a California utility in 1992 and 1993. The tests were conducted at bench, pilot, and demonstration scales, with two source waters. Alum and ferric chloride, with cationic polymer, were investigated at various influent arsenic concentrations. The investigators concluded that for the source waters tested, enhanced coagulation could be effective for arsenic removal and that less ferric chloride than alum, on a weight basis, is needed to achieve the same removal.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Arsenic speciation in the environment
Cullen, W. R., & Reimer, K. J. (1989) · Chemical Reviews · doi:10.1021/cr00094a002 · Cited by 2,587
Cancer risks from arsenic in drinking water
Smith, A. H., Hopenhayn-Rich, C., Bates, M. N., Goeden, H. M., Hertz-Picciotto, I., Duggan, H. M., Wood, R., Kosnett, M. J., & Smith, M. T. (1992) · Environmental Health Perspectives · doi:10.1289/ehp.9297259 · Cited by 1,110
A review of the arsenic cycle in natural waters
Ferguson, J. F., & Gavis, J. (1972) · Water Research · doi:10.1016/0043-1354(72)90052-8 · Cited by 1,013
Chen, C.-J., Chen, C., Wu, M.-M., & Kuo, T.-L. (1992) · British Journal of Cancer · doi:10.1038/bjc.1992.380 · Cited by 773
Office of Environmental Health Hazard Assessment
Patterson, G. T., Branch, T., & Fan, A. M. (2005) · Cited by 400
Water quality and treatment : a handbook of community water supplies
Pontius, F. W. (1990) · McGraw-Hill eBooks · Cited by 278
Removal of Arsenic (V) From Water by Adsorption on Aluminum and Ferric Hydroxides
Gulledge, J. H., & O'Connor, J. T. (1973) · Journal AWWA · doi:10.1002/j.1551-8833.1973.tb01893.x · Cited by 161
Treatment Technology to Meet the interim Primary Drinking Water Regulations for Inorganics: Part 2
Sorg, T. J., & Logsdon, G. S. (1978) · Journal AWWA · doi:10.1002/j.1551-8833.1978.tb04198.x · Cited by 115
WATER TECHNOLOGY‐Study of Arsenic Removal From Drinking Water
Shen, Y. S. (1973) · Journal AWWA · doi:10.1002/j.1551-8833.1973.tb01892.x · Cited by 114
Removing Arsenic From Drinking Water
Hathaway (deceased), S. W., & Rubel, F. (1987) · Journal AWWA · doi:10.1002/j.1551-8833.1987.tb02895.x · Cited by 55
Cited by
Arsenic removal from water/wastewater using adsorbents—A critical review
Mohan, D., & Pittman, C. U. (2007) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2007.01.006 · Cited by 3,536
“oagulation/electrocoagulation/coprecipitation: [405,442,479–499] Alum coagulation Durable powder chemicals are ava and simple in operation; effective Iron coagulation Common chemicals are available; coagulation on weigh basis Lime softening Chemicals are available commerc”
BackgroundPhysico–chemical treatment techniques for wastewater laden with heavy metals
Kurniawan, T. A., Chan, G. Y. S., Lo, W.-H., & Babel, S. (2006) · Chemical Engineering Journal · doi:10.1016/j.cej.2006.01.015 · Cited by 2,072
Arsenic contamination, consequences and remediation techniques: A review
Singh, R., Singh, S., Parihar, P., Singh, V. P., & Prasad, S. M. (2015) · Ecotoxicology and Environmental Safety · doi:10.1016/j.ecoenv.2014.10.009 · Cited by 1,099
Bioadsorbents for remediation of heavy metals: Current status and their future prospects
Gupta, V. K., Nayak, A., & Agarwal, S. (2015) · Environmental Engineering Research · doi:10.4491/eer.2015.018 · Cited by 823
Physico-chemical treatments for removal of recalcitrant contaminants from landfill leachate
Kurniawan, T. A., Lo, W.-H., & Chan, G. Y. (2006) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2005.08.010 · Cited by 693
Wilkie, J. A., & Hering, J. G. (1996) · Colloids and Surfaces A: Physicochemical and Engineering Aspects · doi:10.1016/0927-7757(95)03368-8 · Cited by 666
Bhattacharya, P., Chatterjee, D., & Jacks, G. (1997) · International Journal of Water Resources Development · doi:10.1080/07900629749944 · Cited by 664
Removal of arsenic from water by electrocoagulation
Ratna Kumar, P., Chaudhari, S., Khilar, K. C., & Mahajan, S. P. (2004) · Chemosphere · doi:10.1016/j.chemosphere.2003.12.025 · Cited by 611
Arsenic — a Review. Part II: Oxidation of Arsenic and its Removal in Water Treatment
Bissen, M., & Frimmel, F. H. (2003) · Acta hydrochimica et hydrobiologica · doi:10.1002/aheh.200300485 · Cited by 577
Technologies for Arsenic Removal from Water: Current Status and Future Perspectives
Nicomel, N., Leus, K., Folens, K., Van Der Voort, P., & Du Laing, G. (2015) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph13010062 · Cited by 486
Preparation and Evaluation of GAC-Based Iron-Containing Adsorbents for Arsenic Removal
Gu, Z., Fang, J., & Deng, B. (2005) · Environmental Science & Technology · doi:10.1021/es048179r · Cited by 436
Arsenic(III) and Arsenic(V) Reactions with Zerovalent Iron Corrosion Products
Manning, B. A., Hunt, M. L., Amrhein, C., & Yarmoff, J. A. (2002) · Environmental Science & Technology · doi:10.1021/es0206846 · Cited by 428
Arsenic removal by ferric chloride
Hering, J. G., Chen, P., Wilkie, J. A., Elimelech, M., & Liang, S. (1996) · Journal AWWA · doi:10.1002/j.1551-8833.1996.tb06541.x · Cited by 397
Self-citationCombined effects of anions on arsenic removal by iron hydroxides
Meng, X., Korfiatis, G. P., Bang, S., & Bang, K. W. (2002) · Toxicology Letters · doi:10.1016/s0378-4274(02)00080-2 · Cited by 384
Intraparticle diffusion and adsorption of arsenate onto granular ferric hydroxide (GFH)
Badruzzaman, M., Westerhoff, P., & Knappe, D. R. U. (2004) · Water Research · doi:10.1016/j.watres.2004.07.007 · Cited by 366
Arsenic Removal from Drinking Water during Coagulation
Hering, J. G., Chen, P.-Y., Wilkie, J. A., & Elimelech, M. (1997) · Journal of Environmental Engineering · doi:10.1061/(asce)0733-9372(1997)123:8(800 · Cited by 359
Arsenic Removal from Drinking Water using Iron Oxide-Coated Sand
Thirunavukkarasu, O. S., Viraraghavan, T., & Subramanian, K. S. (2003) · Water, Air, and Soil Pollution · doi:10.1023/a:1022073721853 · Cited by 315
Electrocoagulation treatment of arsenic in wastewaters: A comprehensive review
Song, P., Yang, Z., Zeng, G., Yang, X., Xu, H., Wang, L., Xu, R., Xiong, W., & Ahmad, K. (2017) · Chemical Engineering Journal · doi:10.1016/j.cej.2017.02.086 · Cited by 314
Removal of arsenic from groundwater using low cost ferruginous manganese ore
Chakravarty, S., Dureja, V, Bhattacharyya, G., Maity, S., & Bhattacharjee, S. (2002) · Water Research · doi:10.1016/s0043-1354(01)00234-2 · Cited by 313
The management of arsenic wastes: problems and prospects
Leist, M., Casey, R. J., & Caridi, D. (2000) · Journal of Hazardous Materials · doi:10.1016/s0304-3894(00)00188-6 · Cited by 306
Guo, X., Wu, Z., & He, M. (2009) · Water Research · doi:10.1016/j.watres.2009.06.033 · Cited by 294
Meng, X., Korfiatis, G. P., Christodoulatos, C., & Bang, S. (2001) · Water Research · doi:10.1016/s0043-1354(01)00007-0 · Cited by 284
Bilici Baskan, M., & Pala, A. (2010) · Desalination · doi:10.1016/j.desal.2009.12.016 · Cited by 231
“However, there are limited numbers of studies investigating the effects of cationic [4,28,39,42] and anionic [28] polymers for increasing of arsenic removal.”
BackgroundComparative study of arsenic removal by iron using electrocoagulation and chemical coagulation
Lakshmanan, D., Clifford, D. A., & Samanta, G. (2010) · Water Research · doi:10.1016/j.watres.2010.06.018 · Cited by 220
Rathi, B. S., & Kumar, P. S. (2021) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2021.126299 · Cited by 219
Berg, M., Luzi, S., Trang, P. T. K., Viet, P. H., Giger, W., & Stüben, D. (2006) · Environmental Science & Technology · doi:10.1021/es060144z · Cited by 211
Suzuki, T. M., Bomani, J. O., Matsunaga, H., & Yokoyama, T. (2000) · Reactive and Functional Polymers · doi:10.1016/s1381-5148(99)00038-3 · Cited by 206
Treatment of landfill leachate using a combined stripping, Fenton, SBR, and coagulation process
Guo, J.-S., Abbas, A. A., Chen, Y.-P., Liu, Z.-P., Fang, F., & Chen, P. (2010) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2010.01.144 · Cited by 199
Adsorption of arsenic(V) by activated carbon prepared from oat hulls
Chuang, C. L., Fan, M., Xu, M., Brown, R. C., Sung, S., Saha, B., & Huang, C. P. (2005) · Chemosphere · doi:10.1016/j.chemosphere.2005.03.012 · Cited by 195
“Various approaches have been developed recently, including coagulation with conventional iron and aluminum salts such as ferric chloride and aluminum sulfate (Gulledge and O Connor, 1973; Cheng et al., 1994), lime precipitation, ion exchange (Clifford et al.”
MethodSharma, A. K., Tjell, J. C., Sloth, J. J., & Holm, P. E. (2014) · Applied Geochemistry · doi:10.1016/j.apgeochem.2013.11.012 · Cited by 194
A review on polyaniline-based materials applications in heavy metals removal and catalytic processes
Eskandari, E., Kosari, M., Davood Abadi Farahani, M. H., Khiavi, N. D., Saeedikhani, M., Katal, R., & Zarinejad, M. (2020) · Separation and Purification Technology · doi:10.1016/j.seppur.2019.115901 · Cited by 183
Perspectives of low cost arsenic remediation of drinking water in Pakistan and other countries
Malik, A. H., Khan, Z. M., Mahmood, Q., Nasreen, S., & Bhatti, Z. A. (2009) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2009.02.031 · Cited by 183
“The amount of oagulant used can be significantly reduced by the addition of polyers or colloidal clays during the mixing of the coagulant with he arsenic-contaminated water [42].”
BackgroundArsenic Contamination of Groundwater in Nepal—An Overview
Thakur, J. K., Thakur, R. K., Ramanathan, A., Kumar, M., & Singh, S. K. (2010) · Water · doi:10.3390/w3010001 · Cited by 180
“Various research study had reported that in few groundwater samples have been found to have only one form of As (III), others only As (V), while in some others both forms have been reported in the same water source [6-9].”
BackgroundRemoval of lead, zinc and iron by coagulation–flocculation
Pang, F. M., Kumar, P., Teng, T. T., Mohd Omar, A. K., & Wasewar, K. L. (2011) · Journal of the Taiwan Institute of Chemical Engineers · doi:10.1016/j.jtice.2011.01.009 · Cited by 180
Arsenic Removal from Vietnamese Groundwater Using the Arsenic-Binding DNA Aptamer
Kim, M., Um, H.-J., Bang, S., Lee, S.-H., Oh, S.-J., Han, J.-H., Kim, K.-W., Min, J., & Kim, Y.-H. (2009) · Environmental Science & Technology · doi:10.1021/es902407g · Cited by 174
Wu, Z., He, M., Guo, X., & Zhou, R. (2010) · Separation and Purification Technology · doi:10.1016/j.seppur.2010.10.006 · Cited by 172
Increasing the arsenate adsorption capacity of neutralized red mud (Bauxsol)
Genç-Fuhrman, H., Tjell, J. C., & McConchie, D. (2004) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2003.10.011 · Cited by 159
Effect of organic matter on arsenic removal during coagulation/flocculation treatment
Pallier, V., Feuillade-Cathalifaud, G., Serpaud, B., & Bollinger, J.-C. (2010) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2009.09.068 · Cited by 154
Tripathy, S. S., & Raichur, A. M. (2008) · Chemical Engineering Journal · doi:10.1016/j.cej.2007.06.028 · Cited by 118
“[5] R.”
MethodEffect of aluminum speciation on arsenic removal during coagulation process
Hu, C., Liu, H., Chen, G., & Qu, J. (2012) · Separation and Purification Technology · doi:10.1016/j.seppur.2011.10.017 · Cited by 104
“Early bench, pilot, and demonstration scale studies have shown that As(V) can be efficiently removed during coagulation with ferric chloride and alum even when present at low or high concentration in influent waters [8,9].”
Background
Metadata
- Authors
- Cheng, R. C., Liang, S., Wang, H., & Beuhler, M. D.
- Venue
- Journal AWWA
- Publisher
- Wiley
- Published
- 1994-09
- Volume
- 86
- Issue
- 9
- Pages
- 79-90
- ISSN
- 0003-150X (ISSN-L)
- 1551-8833
- OpenAlex
- W1566584788
- Cited by
- 256
- References
- 11
- FWCI
- 3.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.