Quantitative phase imaging for medical diagnosis
Open accessThe DOI matches its Crossref record; 68 of the 68 references it cites were found in a registry or an index.
Abstract
Optical microscopy is an indispensable diagnostic tool in modern healthcare. As a prime example, pathologists rely exclusively on light microscopy to investigate tissue morphology in order to make a diagnosis. While advances in light microscopy and contrast markers allow pathologists to visualize cells and tissues in unprecedented detail, the interpretation of these images remains largely subjective, leading to inter‐ and intra‐observer discrepancy. Furthermore, conventional microscopy images capture qualitative information which makes it difficult to automate the process, reducing the throughput achievable in the diagnostic workflow. Quantitative Phase Imaging (QPI) techniques have been advanced in recent years to address these two challenges. By quantifying physical parameters of cells and tissues, these systems remove subjectivity from the disease diagnosis process and allow for easier automation to increase throughput. In addition to providing quantitative information, QPI systems are also label‐free and can be easily assimilated into the current diagnostic workflow in the clinic. In this paper we review the advances made in disease diagnosis by QPI techniques. We focus on the areas of hematological diagnosis and cancer pathology, which are the areas where most significant advances have been made to date. [Image adapted from Y. Park, M. Diez‐Silva, G. Popescu, G. Lykotrafitis, W. Choi, M. S. Feld, and S. Suresh, Proc. Natl. Acad. Sci. 105, 13730–13735 (2008).] magnified image[Image adapted from Y. Park, M. Diez‐Silva, G. Popescu, G. Lykotrafitis, W. Choi, M. S. Feld, and S. Suresh, Proc. Natl. Acad. Sci. 105, 13730–13735 (2008).]
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bulletin of the World Health Organization
C., N. H. (1955) · The British Journal of Sociology · doi:10.2307/587237 · Cited by 3,601
Hematoxylin and Eosin Staining of Tissue and Cell Sections
Fischer, A. H., Jacobson, K. A., Rose, J., & Zeller, R. (2008) · Cold Spring Harbor Protocols · doi:10.1101/pdb.prot4986 · Cited by 2,128
Aligned Collagen Is a Prognostic Signature for Survival in Human Breast Carcinoma
Conklin, M. W., Eickhoff, J. C., Riching, K. M., Pehlke, C. A., Eliceiri, K. W., Provenzano, P. P., Friedl, A., & Keely, P. J. (2011) · The American Journal of Pathology · doi:10.1016/j.ajpath.2010.11.076 · Cited by 1,285
Cuche, E., Marquet, P., & Depeursinge, C. (1999) · Applied Optics · doi:10.1364/ao.38.006994 · Cited by 1,107
Red cell membrane: past, present, and future
Mohandas, N., & Gallagher, P. G. (2008) · Blood · doi:10.1182/blood-2008-07-161166 · Cited by 1,089
CANCER CONTROL WITH RADICAL PROSTATECTOMY ALONE IN 1,000 CONSECUTIVE PATIENTS
HULL, G. W., RABBANI, F., ABBAS, F., WHEELER, T. M., KATTAN, M. W., & SCARDINO, P. T. (2002) · Journal of Urology · doi:10.1016/s0022-5347(01)69079-7 · Cited by 964
Choi, W., Fang-Yen, C., Badizadegan, K., Oh, S., Lue, N., Dasari, R. R., & Feld, M. S. (2007) · Nature Methods · doi:10.1038/nmeth1078 · Cited by 955
Principles of Optics Electromagnetic Theory of Propagation, Interference and Diffraction of Light
Born, M., & Wolf, E. (1959) · Cited by 934
Spatial light interference microscopy (SLIM)
Wang, Z., Millet, L. J., Mir, M., Ding, H., Unarunotai, S., Rogers, J. A., Gillette, M. U., & Popescu, G. (2011) · Optics Express · doi:10.1364/oe.19.001016 · Cited by 751
Self-citationVakoc, B. J., Lanning, R. M., Tyrrell, J. A., Padera, T. P., Bartlett, L. A., Stylianopoulos, T., Munn, L. L., Tearney, G. J., Fukumura, D., Jain, R. K., et al. (2009) · Nature Medicine · doi:10.1038/nm.1971 · Cited by 719
Park, Y., Diez-Silva, M., Popescu, G., Lykotrafitis, G., Choi, W., Feld, M. S., & Suresh, S. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0806100105 · Cited by 689
Self-citationRappaz, B., Marquet, P., Cuche, E., Emery, Y., Depeursinge, C., & Magistretti, P. J. (2005) · Optics Express · doi:10.1364/opex.13.009361 · Cited by 674
Predicting 15-Year Prostate Cancer Specific Mortality After Radical Prostatectomy
Eggener, S. E., Scardino, P. T., Walsh, P. C., Han, M., Partin, A. W., Trock, B. J., Feng, Z., Wood, D. P., Eastham, J. A., Yossepowitch, O., et al. (2011) · Journal of Urology · doi:10.1016/j.juro.2010.10.057 · Cited by 640
Taylor, C. R., & Levenson, R. M. (2006) · Histopathology · doi:10.1111/j.1365-2559.2006.02513.x · Cited by 609
Red Cell Deformability and its Relevance to Blood Flow
Chien, S. (1987) · Annual Review of Physiology · doi:10.1146/annurev.ph.49.030187.001141 · Cited by 570
Optical imaging of cell mass and growth dynamics
Popescu, G., Park, Y., Lue, N., Best-Popescu, C., Deflores, L., Dasari, R. R., Feld, M. S., & Badizadegan, K. (2008) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00121.2008 · Cited by 518
Self-citationDeconvolution methods for 3-D fluorescence microscopy images
Sarder, P., & Nehorai, A. (2006) · IEEE Signal Processing Magazine · doi:10.1109/msp.2006.1628876 · Cited by 479
A simple method for measuring erythrocyte deformability.
Reid, H. L., Barnes, A. J., Lock, P. J., Dormandy, J. A., & Dormandy, T. L. (1976) · Journal of Clinical Pathology · doi:10.1136/jcp.29.9.855 · Cited by 464
Quantitative Phase Imaging of Cells and Tissues
Masters, B. R. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.2.029901 · Cited by 458 · cited 3×
“The interferometric geometry always involved in QPI grants this approach extreme sensitivity to tissue architecture of 1 nm or less [2].”
BackgroundCooperberg, M. R., Hilton, J. F., & Carroll, P. R. (2011) · Cancer · doi:10.1002/cncr.26169 · Cited by 457
Immunohistochemistry as an Important Tool in Biomarkers Detection and Clinical Practice
De Matos, L. L., Trufelli, D. C., De Matos, M. G. L., & Da Silva Pinhal, M. A. (2010) · Biomarker Insights · doi:10.4137/bmi.s2185 · Cited by 437
Interference Microscopy and Mass Determination
BARER, R. (1952) · Nature · doi:10.1038/169366b0 · Cited by 433
Diffraction phase microscopy: principles and applications in materials and life sciences
Bhaduri, B., Edwards, C., Pham, H., Zhou, R., Nguyen, T. H., Goddard, L. L., & Popescu, G. (2014) · Advances in Optics and Photonics · doi:10.1364/aop.6.000057 · Cited by 425
Self-citationOptical measurement of cycle-dependent cell growth
Mir, M., Wang, Z., Shen, Z., Bednarz, M., Bashir, R., Golding, I., Prasanth, S. G., & Popescu, G. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1100506108 · Cited by 409
Self-citationDiagnosis from the Blood Smear
Bain, B. J. (2005) · New England Journal of Medicine · doi:10.1056/nejmra043442 · Cited by 407
Intraoperative Evaluation of Breast Tumor Margins with Optical Coherence Tomography
Nguyen, F. T., Zysk, A. M., Chaney, E. J., Kotynek, J. G., Oliphant, U. J., Bellafiore, F. J., Rowland, K. M., Johnson, P. A., & Boppart, S. A. (2009) · Cancer Research · doi:10.1158/0008-5472.can-08-4340 · Cited by 387
Multiple phases of chondrocyte enlargement underlie differences in skeletal proportions
Cooper, K. L., Oh, S., Sung, Y., Dasari, R. R., Kirschner, M. W., & Tabin, C. J. (2013) · Nature · doi:10.1038/nature11940 · Cited by 375
Investigation of living pancreas tumor cells by digital holographic microscopy
Kemper, B., Carl, D., Schnekenburger, J., Bredebusch, I., Schäfer, M., Domschke, W., & von Bally, G. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2204609 · Cited by 364
Tissue refractive index as marker of disease
Wang, Z., Popescu, G., Tangella, K. V., & Balla, A. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3656732 · Cited by 271
Self-citationBlood Cells: A Practical Guide
(2006) · Wiley eBooks · doi:10.1002/9780470987551 · Cited by 271
Rappaz, B., Barbul, A., Emery, Y., Korenstein, R., Depeursinge, C. D., Magistretti, P. J., & Marquet, P. P. (2008) · Cytometry Part A · doi:10.1002/cyto.a.20605 · Cited by 217
Interference Microscopy and Mass Determination
DAVIES, H. G., & WILKINS, M. H. F. (1952) · Nature · doi:10.1038/169541a0 · Cited by 209
Interpretation and Quantification of Immunostains
Seidal, T., Balaton, A. J., & Battifora, H. (2001) · The American Journal of Surgical Pathology · doi:10.1097/00000478-200109000-00013 · Cited by 205
Cytoskeleton Confinement and Tension of Red Blood Cell Membranes
Gov, N., Zilman, A. G., & Safran, S. (2003) · Physical Review Letters · doi:10.1103/physrevlett.90.228101 · Cited by 189
Rappaz, B., Charrière, F., Depeursinge, C., Magistretti, P. J., & Marquet, P. (2008) · Optics Letters · doi:10.1364/ol.33.000744 · Cited by 183
Real-time visualization of 3-D dynamic microscopic objects using optical diffraction tomography
Kim, K., Kim, K. S., Park, H., Ye, J. C., & Park, Y. (2013) · Optics Express · doi:10.1364/oe.21.032269 · Cited by 173
Incidence of sickle cell trait--United States, 2010.
Ojodu, J. A., Hulihan, M., Pope, S., & Grant, A. M. (2014) · PubMed Central · Cited by 158
Label-free characterization of white blood cells by measuring 3D refractive index maps
Yoon, J. W., Kim, K., Park, H., Choi, C., Jang, S., & Park, Y. (2015) · Biomedical Optics Express · doi:10.1364/boe.6.003865 · Cited by 152
Shaked, N. T., Satterwhite, L. L., Truskey, G. A., Wax, A. P., & Telen, M. J. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3556717 · Cited by 152
Radi, M. J. (1989) · PubMed · Cited by 131
Byun, H., Hillman, T. R., Higgins, J. M., Diez-Silva, M., Peng, Z., Dao, M., Dasari, R. R., Suresh, S., & Park, Y. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.07.011 · Cited by 127
Real Time Blood Testing Using Quantitative Phase Imaging
Pham, H. V., Bhaduri, B., Tangella, K. V., Best-Popescu, C. A., & Popescu, G. (2013) · PLoS ONE · doi:10.1371/journal.pone.0055676 · Cited by 119
Self-citationWhole-cell-analysis of live cardiomyocytes using wide-field interferometric phase microscopy
Shaked, N. T., Satterwhite, L. L., Bursac, N., & Wax, A. P. (2010) · Biomedical Optics Express · doi:10.1364/boe.1.000706 · Cited by 115
Jang, Y., Jang, J., & Park, Y. (2012) · Optics Express · doi:10.1364/oe.20.009673 · Cited by 99
Dispersion-relation phase spectroscopy of intracellular transport
Wang, R., Wang, Z., Millet, L. J., Gillette, M. U., Levine, A. J., & Popescu, G. (2011) · Optics Express · doi:10.1364/oe.19.020571 · Cited by 97
Self-citationCalcification in breast lesions: pathologists’ perspective
Tse, G. M., Tan, P.-H., Pang, A. L. M., Tang, A. P. Y., & Cheung, H. S. (2008) · Journal of Clinical Pathology · doi:10.1136/jcp.2006.046201 · Cited by 95
Prediction of Prostate Cancer Recurrence Using Quantitative Phase Imaging
Sridharan, S., Macias, V., Tangella, K. V., Kajdacsy-Balla, A., & Popescu, G. (2015) · Scientific Reports · doi:10.1038/srep09976 · Cited by 94
Self-citationPark, H., Hong, S.-H., Kim, K., Cho, S., Lee, W., Kim, Y., Lee, S.-E., & Park, Y. (2015) · Scientific Reports · doi:10.1038/srep10827 · Cited by 88
Sosa, J. M., Nielsen, N. D., Vignes, S. M., Chen, T. G., & Shevkoplyas, S. S. (2014) · Clinical Hemorheology and Microcirculation · doi:10.3233/ch-131719 · Cited by 88
Walsh, M. J., Holton, S. E., Kajdacsy-Balla, A., & Bhargava, R. (2012) · Vibrational Spectroscopy · doi:10.1016/j.vibspec.2012.01.010 · Cited by 82
Tissue refractometry using Hilbert phase microscopy
Lue, N., Bewersdorf, J., Lessard, M. D., Badizadegan, K., Dasari, R. R., Feld, M. S., & Popescu, G. (2007) · Optics Letters · doi:10.1364/ol.32.003522 · Cited by 80
Self-citationQuantifying cellular differentiation by physical phenotype using digital holographic microscopy
Chalut, K. J., Ekpenyong, A. E., Clegg, W. L., Melhuish, I. C., & Guck, J. R. (2012) · Integrative Biology · doi:10.1039/c2ib00129b · Cited by 79
Bénard, A., Desmedt, C., Smolina, M., Szternfeld, P., Verdonck, M., Rouas, G., Kheddoumi, N., Rothé, F., Larsimont, D., Sotiriou, C. P., et al. (2013) · The Analyst · doi:10.1039/c3an01454a · Cited by 78
Diggs, L. W., & Bibb, J. (1939) · JAMA · doi:10.1001/jama.1939.02800080015004 · Cited by 72
Jo, Y., Jung, J., Lee, J. W., Shin, D., Park, H., Nam, K. T., Park, J., & Park, Y. (2014) · Scientific Reports · doi:10.1038/srep05090 · Cited by 69
Morphological changes in erythrocytes induced by malarial parasites
Aikawa, M. (1988) · Biology of the Cell · doi:10.1016/0248-4900(88)90077-9 · Cited by 64
Uttam, S., Pham, H. V., LaFace, J., Leibowitz, B. J., Yu, J., Brand, R. E., Hartman, D. J., & Liu, Y. (2015) · Cancer Research · doi:10.1158/0008-5472.can-15-1274 · Cited by 63
Immunohistochemical approaches to the diagnosis of undifferentiated malignant tumors
Wick, M. R. (2008) · Annals of Diagnostic Pathology · doi:10.1016/j.anndiagpath.2007.10.003 · Cited by 63
Optical Assay of Erythrocyte Function in Banked Blood
Bhaduri, B., Kandel, M. E., Brugnara, C., Tangella, K. V., & Popescu, G. (2014) · Scientific Reports · doi:10.1038/srep06211 · Cited by 51
Self-citationAnisotropic light scattering of individual sickle red blood cells
Kim, Y., Park, Y., Higgins, J. M., Dasari, R. R., & Suresh, S. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.4.040501 · Cited by 48
Park, H., Ahn, T., Kim, K., et al. (2015) · Journal of Biomedical Optics · doi:10.1117/1.jbo.20.11.111208 · Cited by 47
Bishitz, Y., Gabai, H., Girshovitz, P., & Shaked, N. T. (2013) · Journal of Biophotonics · doi:10.1002/jbio.201300019 · Cited by 42
Quantifying Biomass Changes of Single CD8+ T Cells during Antigen Specific Cytotoxicity
Zangle, T. A., Burnes, D., Mathis, C., Witte, O. N., & Teitell, M. A. (2013) · PLoS ONE · doi:10.1371/journal.pone.0068916 · Cited by 36
Digital holographic microscopy in human sperm imaging
Crha, I., Žáková, J., Hüser, M., Ventruba, P., Lousová, E., & Pohanka, M. (2011) · Journal of Assisted Reproduction and Genetics · doi:10.1007/s10815-011-9584-y · Cited by 33
Red Blood Cell Shape and Fluctuations: Cytoskeleton Confinement and ATP Activity
Gov, N. S., & Safran, S. A. (2005) · Journal of Biological Physics · doi:10.1007/s10867-005-6472-7 · Cited by 26
Bista, R. K., Wang, P., Bhargava, R., Uttam, S., Hartman, D. J., Brand, R. E., & Liu, Y. (2012) · Breast Cancer Research and Treatment · doi:10.1007/s10549-012-2125-2 · Cited by 22
Optical Sensing of Red Blood Cell Dynamics
Park, Y., Best-Popescu, C. A., & Popescu, G. (2011) · Springer eBooks · doi:10.1007/978-1-4419-8083-0_13 · Cited by 13
Self-citationCellular Morphologic Analysis of Peripheral Blood
Peterson, P., McNeill, S., & Gulati, G. L. (2012) · Wiley eBooks · doi:10.1002/9781444398595.ch2 · Cited by 11
Cited by
Quantitative phase imaging based on holography: trends and new perspectives
Huang, Z., & Cao, L. (2024) · Light: Science & Applications · doi:10.1038/s41377-024-01453-x · Cited by 277
Metadata
- Authors
- Majeed, H., Sridharan, S., Mir, M., Ma, L., Min, E., Jung, W., & Popescu, G.
- Venue
- Journal of Biophotonics
- Publisher
- Wiley
- Published
- 2016-08-19
- Volume
- 10
- Issue
- 2
- Pages
- 177-205
- ISSN
- 1864-063X (ISSN-L)
- 1864-0648
- OpenAlex
- W2517760358
- Cited by
- 168
- References
- 68
- FWCI
- 8.89
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.