A comparative evaluation of the tissue responses associated with polymeric implants in the rat and mouse
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
End product application is an important consideration when evaluating a material in an in vivo setting (Didisheim, Cardiovasc Pathol 1993;2:1S–2S). Small animal models allow high through‐put evaluation of biocompatability. Previous preclinical evaluations have often used a rat subcutaneous model for the characterization of material‐tissue interaction. Recent advances in genetic manipulation have provided mouse models with selective expression of a wide range of critical proteins. The rat model does not have many of the resources (i.e., knockouts, SCID, nude) that are present in mouse strains. The availability of these mice provides a resource to delineate the mechanisms regulating the healing associated with implants. However, before the mouse models can be used, they must be validated with respect to their ability to accurately assess tissue reponses to materials. In this study the tissue responses after the implantation of expanded polytetrafluoroethylene (ePTFE) were compared between rat and mouse. Discs of ePTFE (30‐μm internodal distance) were implanted in subcutaneous and epididymal fat tissue of rats (Sprague‐Dawley) and mice (129‐SVJ). After 5 weeks the samples were removed and evaluated for vascular density, inflammation, and fibrous encapsulation. No difference in the vessel density was observed within the peri‐implant subcutaneous and adipose tissue or within the porous material. However, a significant difference was found in the number of activated macrophages and giant cells between these two species. Implants in the rat exhibited greater numbers of activated inflammatory cells in the peri‐implant tissue. The data indicate that the mouse and rat provide a comparable model for evaluating angiogenesis and neovascularization associated with synthetic porous implants. © 2001 Wiley Periodicals, Inc. J Biomed Mater Res 59: 682–689, 2002
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Inflammatory Response to Implants
Anderson, J. M. (1988) · ASAIO Journal · doi:10.1097/00002480-198804000-00005 · Cited by 591
Neovascularization of synthetic membranes directed by membrane microarchitecture
Brauker, J. H., Carr‐Brendel, V. E., Martinson, L. A., Crudele, J., Johnston, W. D., & Johnson, R. C. (1995) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820291208 · Cited by 517
Impaired wound healing and angiogenesis in eNOS-deficient mice
Lee, P. C., Salyapongse, A. N., Bragdon, G. A., Shears, L. L., Watkins, S. C., Edington, H. D. J., & Billiar, T. R. (1999) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1999.277.4.h1600 · Cited by 369
A subcutaneous glucose sensor with improved longevity, dynamic range, and stability of calibration.
Updike, S. J., Shults, M. C., Gilligan, B. J., & Rhodes, R. K. (2000) · Diabetes Care · doi:10.2337/diacare.23.2.208 · Cited by 135
Cited by
Extracellular matrix-based biomaterial scaffolds and the host response
Aamodt, J. M., & Grainger, D. W. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.02.003 · Cited by 509
Advanced strategies to thwart foreign body response to implantable devices
Capuani, S., Malgir, G., Chua, C. Y. X., & Grattoni, A. (2022) · Bioengineering & Translational Medicine · doi:10.1002/btm2.10300 · Cited by 195
“However, the most robust response was observed in the adipose tissue, which is known to be a more hostile microenvironment.(169,170) While, the intraperitoneal space is an attrac-”
BackgroundHelton, K. L., Ratner, B. D., & Wisniewski, N. A. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500317 · Cited by 125
(2003) · PubMed · Cited by 60
Metadata
- Authors
- Kidd, K. R., Dal Ponte, D. B., Kellar, R. S., & Williams, S. K.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 2001-12-12
- Volume
- 59
- Issue
- 4
- Pages
- 682-689
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W2009252634
- Cited by
- 36
- References
- 4
- FWCI
- 1.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A comparative evaluation of the tissue responses associated with polymeric implants in the rat and mouse. https://app.cochat.ai/papers/10.1002/jbm.10032
- The paper
- Kidd, K. R., Dal Ponte, D. B., Kellar, R. S., & Williams, S. K. (2002). A comparative evaluation of the tissue responses associated with polymeric implants in the rat and mouse. Journal of Biomedical Materials Research. https://doi.org/10.1002/jbm.10032
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.