The sintered microsphere matrix for bone tissue engineering: In vitro osteoconductivity studies
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
A tissue engineering approach has been used to design three‐dimensional synthetic matrices for bone repair. The osteoconductivity and degradation profile of a novel polymeric bone‐graft substitute was evaluated in an in vitro setting. Using the copolymer poly(lactide‐co‐glycolide) [PLAGA], a sintering technique based on microsphere technology was used to fabricate three‐dimensional porous scaffolds for bone regeneration. Osteoblasts and fibroblasts were seeded onto a 50:50 PLAGA scaffold. Morphologic evaluation through scanning electron microscopy demonstrated that both cell types attached and spread over the scaffold. Cells migrated through the matrix using cytoplasmic extensions to bridge the structure. Cross‐sectional images indicated that cellular proliferation had penetrated into the matrix approximately 700 μm from the surface. Examination of the surfaces of cell/matrix constructs demonstrated that cellular proliferation had encompassed the pores of the matrix by 14 days of cell culture. With the aim of optimizing polymer composition and polymer molecular weight, a degradation study was conducted utilizing the matrix. The results demonstrate that degradation of the sintered matrix is dependent on molecular weight, copolymer ratio, and pore volume. From this data, it was determined that 75:25 PLAGA with an initial molecular weight of 100,000 has an optimal degradation profile. These studies show that the sintered microsphere matrix has an osteoconductive structure capable of functioning as a cellular scaffold with a degradation profile suitable for bone regeneration. © 2002 Wiley Periodicals, Inc. J Biomed Mater Res 61: 421–429, 2002
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hydrolytic degradation of devices based on poly(DL-lactic acid) size-dependence
Grizzi, I., Garreau, H., Li, S., & Vert, M. (1995) · Biomaterials · doi:10.1016/0142-9612(95)93258-f · Cited by 895
Miller, R. A., Brady, J. M., & Cutright, D. E. (1977) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820110507 · Cited by 722
Osteolytic changes accompanying degradation of absorbable fracture fixation implants
Bostman, O. (1991) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.73b4.1649195 · Cited by 294
Athanasiou, K. A., Schmitz, J. P., & Agrawal, C. M. (1998) · Tissue Engineering · doi:10.1089/ten.1998.4.53 · Cited by 110
Cited by
Polymeric Scaffolds in Tissue Engineering Application: A Review
Dhandayuthapani, B., Yoshida, Y., Maekawa, T., & Kumar, D. S. (2011) · International Journal of Polymer Science · doi:10.1155/2011/290602 · Cited by 1,773
“The gel microsphere matrix and the sintered microsphere matrix were designed using the random packing of PLAGA microspheres to create a three-dimensional porous structure for bone regeneration [194].”
MethodWei, G., & Ma, P. X. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.12.005 · Cited by 1,271
Mano, J. F., Silva, G. A., Azevedo, H. S., Malafaya, P. B., Sousa, R. A., Silva, S. S., Boesel, L. F., Oliveira, J. M., Santos, T. C., Marques, A. P., et al. (2007) · Journal of The Royal Society Interface · doi:10.1098/rsif.2007.0220 · Cited by 1,140
Recent advances in biomaterials for 3D scaffolds: A review
Nikolova, M. P., & Chavali, M. S. (2019) · Bioactive Materials · doi:10.1016/j.bioactmat.2019.10.005 · Cited by 907
“An advantage of the sintered porous structure is the ability to form a 3D porous structure suitable for bone regeneration [38].”
BackgroundLaurencin, C., Khan, Y., & El-Amin, S. F. (2006) · Expert Review of Medical Devices · doi:10.1586/17434440.3.1.49 · Cited by 716
Self-citation
Metadata
- Authors
- Borden, M., Attawia, M., & Laurencin, C. T.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 2002-05-15
- Volume
- 61
- Issue
- 3
- Pages
- 421-429
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W2160478451
- Cited by
- 154
- References
- 4
- FWCI
- 5.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.