Abstract
The ability of tetraethylene glycol dimethyl ether (tetraglyme) plasma deposited coatings exhibiting ultralow fibrinogen adsorption to reduce blood activation was studied with six in vitro methods, namely fibrinogen and von Willebrand's factor adsorption, total protein adsorption, clotting time in recalcified plasma, platelet adhesion and procoagulant activity, and whole blood thrombosis in a disturbed flow catheter model. Surface plasmon resonance results showed that tetraglyme surfaces strongly resisted the adsorption of all proteins from human plasma. The clotting time in the presence of tetraglyme surfaces was lengthened compared with controls, indicating a lower activation of the intrinsic coagulation cascade. Platelet adhesion and thrombin generation by adherent platelets were greatly reduced on tetraglyme‐coated materials, compared with uncoated and Biospan®‐coated glass slides. In the in vitro disturbed blood flow model, tetraglyme plasma coated catheters had 50% less thrombus than did the uncoated catheters. Tetraglyme‐coated materials thus had greatly reduced blood interactions as measured with all six methods. The improved blood compatibility of plasma‐deposited tetraglyme is thus not only due to their reduced platelet adhesion and activation, but also to a generalized reduction in blood interactions. © 2007 Wiley Periodicals, Inc. J Biomed Mater Res 2007
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Survey of Structure−Property Relationships of Surfaces that Resist the Adsorption of Protein
Ostuni, E., Chapman, R. G., Holmlin, R. E., Takayama, S., & Whitesides, G. M. (2001) · Langmuir · doi:10.1021/la010384m · Cited by 1,799
Cited by
Jiang, S., & Cao, Z. (2010) · Advanced Materials · doi:10.1002/adma.200901407 · Cited by 2,027
Surface hydration: Principles and applications toward low-fouling/nonfouling biomaterials
Chen, S., Li, L., Zhao, C., & Zheng, J. (2010) · Polymer · doi:10.1016/j.polymer.2010.08.022 · Cited by 1,677
Brain Tissue Responses to Neural Implants Impact Signal Sensitivity and Intervention Strategies
Kozai, T. D. Y., Jaquins-Gerstl, A. S., Vazquez, A. L., Michael, A. C., & Cui, X. T. (2015) · ACS Chemical Neuroscience · doi:10.1021/cn500256e · Cited by 622
Blood compatibility of surfaces with superlow protein adsorption
Zhang, Z., Zhang, M., Chen, S., Horbett, T. A., Ratner, B. D., & Jiang, S. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.07.039 · Cited by 462
Self-citationBernard, M., Jubeli, E., Pungente, M. D., & Yagoubi, N. (2018) · Biomaterials Science · doi:10.1039/c8bm00518d · Cited by 350
The catastrophe revisited: Blood compatibility in the 21st Century
Ratner, B. D. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.07.035 · Cited by 347
Self-citationUltra-low fouling peptide surfaces derived from natural amino acids
Chen, S., Cao, Z., & Jiang, S. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.07.001 · Cited by 335
Cao, Z., & Jiang, S. (2012) · Nano Today · doi:10.1016/j.nantod.2012.08.001 · Cited by 329
Biocompatible and Bioactive Surface Modifications for Prolonged In Vivo Efficacy
Meyers, S. R., & Grinstaff, M. W. (2012) · Chemical Reviews · doi:10.1021/cr2000916 · Cited by 294
The blood compatibility challenge. Part 2: Protein adsorption phenomena governing blood reactivity
Brash, J. L., Horbett, T. A., Latour, R. A., & Tengvall, P. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.06.022 · Cited by 282
Self-citationSurface chemistry to minimize fouling from blood-based fluids
Blaszykowski, C., Sheikh, S., & Thompson, M. (2012) · Chemical Society Reviews · doi:10.1039/c2cs35170f · Cited by 271
Yang, W., Chen, S., Cheng, G., Vaisocherová, H., Xue, H., Li, W., Zhang, J., & Jiang, S. (2008) · Langmuir · doi:10.1021/la801487f · Cited by 258
Kozai, T. D. Y., Vazquez, A. L., Weaver, C. L., Kim, S.-G., & Cui, X. T. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/6/066001 · Cited by 215
“…compromised, depositing molecules foreign to the CNS, such as albumin, immunoglobulins (IgG/IgM/IgA), fibrinogen, complement, and red blood cells (Cao et al 2007, Alafuzoff et al 1983, Winslow et al 2010, Gasque et al 2000, Fitch et al 1999), all of which could trigger CNS immune responses and…”
BackgroundKozai, T. D. Y., Li, X., Bodily, L. M., Caparosa, E. M., Zenonos, G. A., Carlisle, D. L., Friedlander, R. M., & Cui, X. T. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.08.006 · Cited by 136
Temporal progression of the host response to implanted poly(ethylene glycol)‐based hydrogels
Lynn, A. D., Blakney, A. K., Kyriakides, T. R., & Bryant, S. J. (2011) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.33015 · Cited by 77
Metadata
- Authors
- Cao, L., Chang, M., Lee, C., Castner, D. G., Sukavaneshvar, S., Ratner, B. D., & Horbett, T. A.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2007-01-18
- Volume
- 81A
- Issue
- 4
- Pages
- 827-837
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W1969177584
- Cited by
- 86
- References
- 1
- FWCI
- 3.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.