In vivo two-photon microscopy reveals immediate microglial reaction to implantation of microelectrode through extension of processes
Open accessAbstract
OBJECTIVE: Penetrating cortical neural probe technologies allow investigators to record electrical signals in the brain. Implantation of probes results in acute tissue damage, and microglia density increases around implanted devices over weeks. However, the mechanisms underlying this encapsulation are not well understood in the acute temporal domain. The objective here was to evaluate dynamic microglial response to implanted probes using two-photon microscopy. APPROACH: Using two-photon in vivo microscopy, cortical microglia ∼200 µm below the surface of the visual cortex were imaged every minute in mice with green fluorescent protein-expressing microglia. MAIN RESULTS: Following probe insertion, nearby microglia immediately extended processes toward the probe at (1.6 ± 1.3) µm min(-1) during the first 30-45 min, but showed negligible cell body movement for the first 6 h. Six hours following probe insertion, microglia at distances <130.0 µm (p = 0.5) from the probe surface exhibit morphological characteristics of transitional stage (T-stage) activation, similar to the microglial response observed with laser-induced blood-brain barrier damage. T-stage morphology and microglia directionality indexes were developed to characterize microglial response to implanted probes. Evidence suggesting vascular reorganization after probe insertion and distant vessel damage was also observed hours after probe insertion. SIGNIFICANCE: A precise temporal understanding of the cellular response to microelectrode implantation will facilitate the search for molecular cues initiating and attenuating the reactive tissue response.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The implant's size and volume directly correlate with the risk of intracerebral hemorrhage and ischemic injuries.
“The implant’s size and volume directly correlate with the risk of intracerebral hemorrhage and ischemic injuries (Rosidi et al., 2011), with larger implants exerting more pressure, potentially leading to vascular compression and secondary injuries (Jaquins-Gerstl and Michael, 2009; Kozai et al., 2012).”
From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Kozai et al., 2012
Kozai et al. is cited for the sentence’s second clause, not the size–risk correlation attributed to Rosidi et al. In the Discussion sections on acute BBB microhemorrhage and mechanical strain (page unavailable), the paper links probe volume to tissue displacement and damage, and reports nearby capillaries losing perfusion. It does not establish that larger implants exert more pressure or that their size causes vascular compression and secondary injuries. (LLM, conf=0.84)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
New diagnostic criteria for multiple sclerosis: Guidelines for research protocols
Poser, C. M., Paty, D. W., Scheinberg, L., McDonald, W. I., Davis, F. A., Ebers, G. C., Johnson, K. P., Sibley, W. A., Silberberg, D. H., & Tourtellotte, W. W. (1983) · Annals of Neurology · doi:10.1002/ana.410130302 · Cited by 7,384 · see citing works
Resting microglial cells are highly dynamic surveillants of brain parenchyma in vivo
Nimmerjahn, A., Kirchhoff, F., & Helmchen, F. (2005) · Science · doi:10.1126/science.1110647 · Cited by 5,827 · see citing works
Microglia: a sensor for pathological events in the CNS
Kreutzberg, G. W. (1996) · Trends in Neurosciences · doi:10.1016/0166-2236(96)10049-7 · Cited by 4,396 · see citing works
Synaptic Pruning by Microglia Is Necessary for Normal Brain Development
Paolicelli, R. C., Bolasco, G., Pagani, F., Maggi, L., Scianni, M., Panzanelli, P., Giustetto, M., Ferreira, T. A., Guiducci, E., Dumas, L., et al. (2011) · Science · doi:10.1126/science.1202529 · Cited by 4,244 · see citing works
Deep tissue two-photon microscopy
Helmchen, F., & Denk, W. T. (2005) · Nature Methods · doi:10.1038/nmeth818 · Cited by 4,165 · see citing works
Microglia Sculpt Postnatal Neural Circuits in an Activity and Complement-Dependent Manner
Schafer, D. P., Lehrman, E. K., Kautzman, A. G., Koyama, R., Mardinly, A. R., Yamasaki, R., Ransohoff, R. M., Greenberg, M. E., Barres, B. A., & Stevens, B. (2012) · Neuron · doi:10.1016/j.neuron.2012.03.026 · Cited by 4,089 · see citing works
ATP mediates rapid microglial response to local brain injury in vivo
Davalos, D., Grutzendler, J., Yang, G., Kim, J. V., Zuo, Y., Jung, S., Littman, D. R., Dustin, M. L., & Gan, W.-B. (2005) · Nature Neuroscience · doi:10.1038/nn1472 · Cited by 3,913 · see citing works
Nonlinear magic: multiphoton microscopy in the biosciences
Zipfel, W. R., Williams, R. M., & Webb, W. W. (2003) · Nature Biotechnology · doi:10.1038/nbt899 · Cited by 3,911 · see citing works
Microglia: Active sensor and versatile effector cells in the normal and pathologic brain
Hanisch, U.-K., & Kettenmann, H. (2007) · Nature Neuroscience · doi:10.1038/nn1997 · Cited by 3,676 · see citing works
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896 · see citing works
Wake, H., Moorhouse, A. J., Jinno, S., Kohsaka, S., & Nabekura, J. (2009) · The Journal of Neuroscience · doi:10.1523/jneurosci.4363-08.2009 · Cited by 1,619 · see citing works
Microglial interactions with synapses are modulated by visual experience
Tremblay, M.-È., Lowery, R. L., & Majewska, A. K. (2010) · PLoS Biology · doi:10.1371/journal.pbio.1000527 · Cited by 1,542 · see citing works
Mechanisms of brain injury after intracerebral haemorrhage
Xi, G., Keep, R. F., & Hoff, J. T. (2005) · The Lancet Neurology · doi:10.1016/s1474-4422(05)70283-0 · Cited by 1,365 · see citing works
KLATZO, I. (1967) · Journal of Neuropathology & Experimental Neurology · doi:10.1097/00005072-196701000-00001 · Cited by 1,180 · see citing works
Mechanisms of Spreading Depression and Hypoxic Spreading Depression-Like Depolarization
Somjen, G. G. (2001) · Physiological Reviews · doi:10.1152/physrev.2001.81.3.1065 · Cited by 1,124 · see citing works
Principles of two-photon excitation microscopy and its applications to neuroscience
Svoboda, K., & Yasuda, R. (2006) · Neuron · doi:10.1016/j.neuron.2006.05.019 · Cited by 1,027 · see citing works
Biran, R., Martin, D. C., & Tresco, P. A. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2005.04.020 · Cited by 893 · see citing works
Raivich, G., Bohatschek, M., Kloss, C. U. A., Werner, A., Jones, L. L., & Kreutzberg, G. W. (1999) · Brain Research Reviews · doi:10.1016/s0165-0173(99)00007-7 · Cited by 843 · see citing works
Brain responses to micro-machined silicon devices
Szarowski, D. H., Andersen, M. D., Retterer, S. T., Spence, A. J., Isaacson, M. S., Craighead, H. G., Turner, J. N., & Shain, W. G. (2003) · Brain Research · doi:10.1016/s0006-8993(03)03023-3 · Cited by 798 · see citing works
Brain-Controlled Interfaces: Movement Restoration with Neural Prosthetics
Schwartz, A. B., Cui, X. T., Weber, D. J., & Moran, D. W. (2006) · Neuron · doi:10.1016/j.neuron.2006.09.019 · Cited by 792 · see citing works
Self-citationChronic, multisite, multielectrode recordings in macaque monkeys
Nicolelis, M. A. L., Dimitrov, D., Carmena, J. M., Crist, R., Lehew, G., Kralik, J. D., & Wise, S. P. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1934665100 · Cited by 740 · see citing works
Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex
Rousche, P. J., & Normann, R. A. (1998) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(98)00031-4 · Cited by 646 · see citing works
Dynamics of microglial activation: A confocal time-lapse analysis in hippocampal slices
Stence, N., Waite, M., & Dailey, M. E. (2001) · Glia · doi:10.1002/1098-1136(200103)33:3 · Cited by 617 · see citing works
Wild-type microglia arrest pathology in a mouse model of Rett syndrome
Derecki, N. C., Cronk, J. C., Lu, Z., Xu, E., Abbott, S. B. G., Guyenet, P. G., & Kipnis, J. (2012) · Nature · doi:10.1038/nature10907 · Cited by 607 · see citing works
Fitch, M. T., Doller, C. M., Combs, C. K., Landreth, G. E., & Silver, J. (1999) · Journal of Neuroscience · doi:10.1523/jneurosci.19-19-08182.1999 · Cited by 600 · see citing works
Cui, X. T., & Martin, D. C. (2003) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(02)00448-3 · Cited by 581 · see citing works
Self-citationWadhwa, R., Lagenaur, C. F., & Cui, X. T. (2005) · Journal of Controlled Release · doi:10.1016/j.jconrel.2005.10.027 · Cited by 498 · see citing works
Self-citationJones, L. L., Yamaguchi, Y., Stallcup, W. B., & Tuszynski, M. H. (2002) · Journal of Neuroscience · doi:10.1523/jneurosci.22-07-02792.2002 · Cited by 482 · see citing works
McConnell, G. C., Rees, H. D., Levey, A. I., Gutekunst, C.-A., Gross, R. E., & Bellamkonda, R. V. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/5/056003 · Cited by 480 · see citing works
Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex
Edell, D. J., Toi, V. V., McNeil, V. M., & Clark, L. D. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.141202 · Cited by 479 · see citing works
Neural probe design for reduced tissue encapsulation in CNS
Seymour, J. P., & Kipke, D. R. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.03.024 · Cited by 462 · see citing works
Kim, D., & Martin, D. C. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.12.021 · Cited by 432 · see citing works
Yang, G., Betz, A. L., Chenevert, T. L., Brunberg, J. A., & Hoff, J. T. (1994) · Journal of neurosurgery · doi:10.3171/jns.1994.81.1.0093 · Cited by 412 · see citing works
Chronic optical access through a polished and reinforced thinned skull
Drew, P. J., Shih, A. Y., Driscoll, J. D., Knutsen, P. M., Blinder, P., Davalos, D., Akassoglou, K., Tsai, P. S., & Kleinfeld, D. (2010) · Nature Methods · doi:10.1038/nmeth.1530 · Cited by 406 · see citing works
Current concepts of brain edema
Kimelberg, H. K. (1995) · Journal of neurosurgery · doi:10.3171/jns.1995.83.6.1051 · Cited by 406 · see citing works
Williams, J. C., Rennaker, R. L., & Kipke, D. R. (1999) · Brain Research Protocols · doi:10.1016/s1385-299x(99)00034-3 · Cited by 396 · see citing works
Subbaroyan, J., Martin, D. C., & Kipke, D. R. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/4/006 · Cited by 368 · see citing works
Barzó, P., Marmarou, A., Fatouros, P. P., Hayasaki, K., & Corwin, F. D. (1997) · Journal of neurosurgery · doi:10.3171/jns.1997.87.6.0900 · Cited by 368 · see citing works
Complement components of the innate immune system in health and disease in the CNS
Gasque, P., Dean, Y. D., McGreal, E. P., VanBeek, J., & Morgan, B. P. (2000) · Immunopharmacology · doi:10.1016/s0162-3109(00)80302-1 · Cited by 343 · see citing works
Biran, R., Martin, D. C., & Tresco, P. A. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31138 · Cited by 336 · see citing works
Bjornsson, C. S., Oh, S., Al‐Kofahi, Y., Lim, Y.-J., Smith, K. L., Turner, J. N., De, S., Roysam, B., Shain, W. G., & Kim, S. J. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/3/002 · Cited by 330 · see citing works
Self-citationBrain micromotion around implants in the rodent somatosensory cortex
Gilletti, A., & Muthuswamy, J. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/3/001 · Cited by 307 · see citing works
Toward a comparison of microelectrodes for acute and chronic recordings
Ward, M. P., Rajdev, P., Ellison, C., & Irazoqui, P. P. (2009) · Brain Research · doi:10.1016/j.brainres.2009.05.052 · Cited by 296 · see citing works
Biomechanical analysis of silicon microelectrode-induced strain in the brain
Lee, H., Bellamkonda, R. V., Sun, W., & Levenston, M. E. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/4/003 · Cited by 281 · see citing works
Liu, X., McCreery, D. B., Carter, R. R., Bullara, L. A., Yuen, T. G. H., & Agnew, W. F. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.788468 · Cited by 272 · see citing works
Rapid Reversible Changes in Dendritic Spine Structure<i>In Vivo</i>Gated by the Degree of Ischemia
Zhang, S., Boyd, J., Delaney, K., & Murphy, T. H. (2005) · The Journal of Neuroscience · doi:10.1523/jneurosci.1085-05.2005 · Cited by 267 · cited 1× · see citing works
“This loss of perfusion and vascular reorganization might contribute to the ischemic microenvironment immediately surrounding the electrode (Zhang et al 2005, Zhang and Murphy 2007).”
BackgroundCarbon nanotube nanoreservior for controlled release of anti-inflammatory dexamethasone
Luo, X., Matranga, C., Tan, S., Alba, N. A., & Cui, X. T. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.05.020 · Cited by 250 · see citing works
Self-citationMajewska, A., Brown, E., Ross, J., & Yuste, R. (2000) · The Journal of Neuroscience · doi:10.1523/jneurosci.20-05-01722.2000 · Cited by 248 · see citing works
Chronic response of adult rat brain tissue to implants anchored to the skull
Kim, Y. T., Hitchcock, R. W., Bridge, M. J., & Tresco, P. A. (2003) · Biomaterials · doi:10.1016/j.biomaterials.2003.09.010 · Cited by 214 · see citing works
Mechanisms of Edema Formation After Intracerebral Hemorrhage
Xi, G., Hua, Y., Bhasin, R. R., Ennis, S. R., Keep, R. F., & Hoff, J. T. (2001) · Stroke · doi:10.1161/hs1201.099820 · Cited by 209 · see citing works
Kim, D., Wiler, J. A., Anderson, D. J., Kipke, D. R., & Martin, D. C. (2009) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.07.034 · Cited by 206 · see citing works
Zhang, S., & Murphy, T. H. (2007) · PLoS Biology · doi:10.1371/journal.pbio.0050119 · Cited by 193 · see citing works
Kozai, T. D. Y., & Kipke, D. R. (2009) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2009.08.002 · Cited by 186 · see citing works
Self-citationKozai, T. D. Y., Marzullo, T., Hooi, F. M., Langhals, N. B., Majewska, A. K., Brown, E. B., & Kipke, D. R. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/4/046011 · Cited by 179 · see citing works
Self-citationHe, W., McConnell, G. C., & Bellamkonda, R. V. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/4/009 · Cited by 177 · see citing works
Winslow, B. D., Christensen, M. B., Yang, W.-K., Solzbacher, F., & Tresco, P. A. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.05.050 · Cited by 171 · see citing works
Azemi, E., Lagenaur, C. F., & Cui, X. T. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2010.09.033 · Cited by 164 · see citing works
Self-citationWilson, H. A., Winfield, J. B., Lahita, R. G., & Koffler, D. (1979) · Arthritis & Rheumatism · doi:10.1002/art.1780220504 · Cited by 130 · see citing works
Alafuzoff, I. I., Adolfsson, R., Bucht, G., & Winblad, B. G. (1983) · Journal of the Neurological Sciences · doi:10.1016/0022-510x(83)90157-0 · Cited by 128 · see citing works
Brain edema: a classification based on blood-brain barrier integrity.
Al, B., Iannotti, F., & Hoff, J. T. (1989) · PubMed · Cited by 123 · see citing works
Diffusion of albumins in rat cortical slices and relevance to volume transmission
Tao, L., & Nicholson, C. (1996) · Neuroscience · doi:10.1016/0306-4522(96)00303-x · Cited by 116 · see citing works
Microprisms for In Vivo Multilayer Cortical Imaging
Chia, T. H., & Levene, M. J. (2009) · Journal of Neurophysiology · doi:10.1152/jn.91208.2008 · Cited by 95 · see citing works
Rosidi, N. L., Zhou, J., Pattanaik, S., Wang, P., Jin, W., Brophy, M., Olbricht, W. L., Nishimura, N., & Schaffer, C. B. (2011) · PLoS ONE · doi:10.1371/journal.pone.0026612 · Cited by 87 · see citing works
Cao, L., Chang, M., Lee, C., Castner, D. G., Sukavaneshvar, S., Ratner, B. D., & Horbett, T. A. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31091 · Cited by 86 · see citing works
Eter, N., Engel, D. R., Meyer, L. M., Helb, H. –., Roth, F., Maurer, J., Holz, F. G., & Kurts, C. (2008) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.07-1322 · Cited by 84 · see citing works
Evaluation of the stability of intracortical microelectrode arrays
Liu, X., McCreery, D. B., Bullara, L. A., & Agnew, W. F. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.870495 · Cited by 84 · see citing works
Seitz, R. J., Heininger, K., Schwendemann, G., Toyka, K. V., & Wechsler, W. (1985) · Acta Neuropathologica · doi:10.1007/bf00688950 · Cited by 81 · see citing works
Multiscale Measurements Distinguish Cellular and Interstitial Hindrances to Diffusion In Vivo
Chauhan, V. P., Lanning, R. M., Diop-Frimpong, B., Mok, W., Brown, E. B., Padera, T. P., Boucher, Y., & Jain, R. K. (2009) · Biophysical Journal · doi:10.1016/j.bpj.2009.03.064 · Cited by 77 · see citing works
Hailer, N. P., Bechmann, I., Heizmann, S., & Nitsch, R. (1997) · Hippocampus · doi:10.1002/(sici)1098-1063(1997)7:3 · Cited by 77 · see citing works
<i>In vivo</i> evaluation of a neural stem cell-seeded prosthesis
Purcell, E. K., Seymour, J. P., Yandamuri, S., & Kipke, D. R. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/2/026005 · Cited by 76 · see citing works
Aihara, N., Tanno, H., Hall, J. J., Pitts, L. H., & Noble‐Haeusslein, L. J. (1994) · The Journal of Comparative Neurology · doi:10.1002/cne.903420402 · Cited by 71 · see citing works
Wells, G., Catlin, G., Cossins, J. A., Mangan, M., Ward, G. A., Miller, K., & Clements, J. M. (1996) · Glia · doi:10.1002/(sici)1098-1136(199612)18:4 · Cited by 67 · see citing works
In vivo performance of a microelectrode neural probe with integrated drug delivery
Rohatgi, P., Langhals, N. B., Kipke, D. R., & Patil, P. G. (2009) · Neurosurgical FOCUS · doi:10.3171/2009.4.focus0983 · Cited by 59 · see citing works
Abdul‐Karim, M., Al-Kofahi, K., Brown, E. B., Jain, R. K., & Roysam, B. (2003) · Microvascular Research · doi:10.1016/s0026-2862(03)00039-6 · Cited by 51 · see citing works
In situ characterization of the brain–microdevice interface using Device Capture Histology
Woolley, A. J., Desai, H. A., Steckbeck, M. A., Patel, N. K., & Otto, K. J. (2011) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2011.07.012 · Cited by 47 · see citing works
Seeding neural progenitor cells on silicon-based neural probes: Laboratory investigation
Azemi, E., Gobbel, G. T., & Cui, X. T. (2010) · Journal of Neurosurgery · doi:10.3171/2010.1.jns09313 · Cited by 47 · see citing works
Self-citationIn vivo observation of the locomotion of microglial cells in the retina
Pâques, M., Simonutti, M., Augustin, S., Goupille, O., Mathari, B. E., & Sahel, J. (2010) · Glia · doi:10.1002/glia.21037 · Cited by 44 · see citing works
AZZI, G., Bernaudin, J., Bouchaud, C., Bellon, B., & Fleury‐Feith, J. (1990) · Biology of the Cell · doi:10.1111/j.1768-322x.1990.tb00890.x · Cited by 37 · see citing works
Functional Studies in Living Animals Using Multiphoton Microscopy
Dunn, K. W., & Sutton, T. A. (2008) · ILAR Journal · doi:10.1093/ilar.49.1.66 · Cited by 36 · see citing works
Bernstein, J. J., & Goldberg, W. J. (1987) · Brain Research · doi:10.1016/0006-8993(87)90430-6 · Cited by 30 · see citing works
Brain Reactive Autoantibodies and Cognitive Impairment in Systemic Lupus Erythematosus
Hanly, J. G., Fisk, J. D., & Eastwood, B. J. (1994) · Lupus · doi:10.1177/096120339400300311 · Cited by 25 · see citing works
Constant pressure fluid infusion into rat neocortex from implantable microfluidic devices
Retterer, S. T., Smith, K. L., Bjornsson, C. S., Turner, J. N., Isaacson, M. S., & Shain, W. G. (2008) · Journal of Neural Engineering · doi:10.1088/1741-2560/5/4/003 · Cited by 24 · see citing works
Lowery, R. L., Zhang, Y., Kelly, E. A., Lamantia, C. E., Harvey, B. K., & Majewska, A. K. (2009) · Developmental Neurobiology · doi:10.1002/dneu.20735 · Cited by 21 · see citing works
Sequestering of immunoglobulins by astrocytes after cortical lesion and homografting of fetal cortex
Bernstein, J. J., Willingham, L. A., & Goldberg, W. J. (1993) · International Journal of Developmental Neuroscience · doi:10.1016/0736-5748(93)90072-l · Cited by 17 · see citing works
Optical Window Preparation for Two-Photon Imaging of Microglia in Mice: Figure 1.Preprint
Nimmerjahn, A. (2012) · Cold Spring Harbor Protocols · doi:10.1101/pdb.prot069286 · Cited by 14 · see citing works
Flagged first, then by citations
Research works printed but not linked: 3
- Gilgunn PJ Khilwani R Kozai TDY Weber DJ Cui XT Erdos G Ozdoganlar OB Fedder GK An ultra-compliant, scalable neural probes with molded biodissolvable delivery vehicle 25th Int. Conf. on Micro Electro Mechanical Systems (MEMS), IEEE 2012 2012 56 59
- Hailer NP Jarhult JD Nitsch R Resting microglial cells in vitro analysis of morphology and adhesion molecule expression in organotypic hippocampal slice cultures Glia 1996 18 319 331 8972800
- Klatzo I Presidental address. Neuropathological aspects of brain edema J. Neuropathol. Exp. Neurol 1967 26 1 14 5336776
Cited by
Sorted by citations
Yang, J. C., Mun, J., Kwon, S. Y., Park, S., Bao, Z., & Park, S. (2019) · Advanced Materials · doi:10.1002/adma.201904765 · Cited by 1,641 · see citing works
Kozai, T. D. Y., Langhals, N. B., Patel, P. R., Deng, X., Zhang, H., Smith, K. L., Lahann, J., Kotov, N. A., & Kipke, D. R. (2012) · Nature Materials · doi:10.1038/nmat3468 · Cited by 721 · see citing works
Self-citationGlial responses to implanted electrodes in the brain
Salatino, J. W., Ludwig, K. A., Kozai, T. D. Y., & Purcell, E. K. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0154-1 · Cited by 642 · see citing works
Self-citationBrain Tissue Responses to Neural Implants Impact Signal Sensitivity and Intervention Strategies
Kozai, T. D. Y., Jaquins-Gerstl, A. S., Vazquez, A. L., Michael, A. C., & Cui, X. T. (2015) · ACS Chemical Neuroscience · doi:10.1021/cn500256e · Cited by 622 · see citing works
Self-citationA Materials Roadmap to Functional Neural Interface Design
Wellman, S. M., Eles, J. R., Ludwig, K. A., Seymour, J. P., Michelson, N. J., McFadden, W. E., Vazquez, A. L., & Kozai, T. D. Y. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701269 · Cited by 389 · see citing works
Self-citationLewis, P. M., Ackland, H. M., Lowery, A. J., & Rosenfeld, J. V. (2015) · Brain Research · doi:10.1016/j.brainres.2014.11.020 · Cited by 228 · see citing works
Kozai, T. D. Y., Catt, K. A., Li, X., Gugel, Z. V., Olafsson, V. T., Vazquez, A. L., & Cui, X. T. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.10.040 · Cited by 214 · see citing works
Self-citationState-of-the-art MEMS and microsystem tools for brain research
Seymour, J. P., Wu, F., Wise, K. D., & Yoon, E. (2017) · Microsystems & Nanoengineering · doi:10.1038/micronano.2016.66 · Cited by 216 · see citing works
Ultrasoft microwire neural electrodes improve chronic tissue integration
Du, Z. J., Kolarcik, C. L., Kozai, T. D. Y., Luebben, S. D., Sapp, S. A., Zheng, X. S., Nabity, J., & Cui, X. T. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.02.010 · Cited by 208 · see citing works
Self-citationChronic <i>in vivo</i> stability assessment of carbon fiber microelectrode arrays
Patel, P. R., Zhang, H., Robbins, M. T., Nofar, J. B., Marshall, S. P., Kobylarek, M. J., Kozai, T. D. Y., Kotov, N. A., & Chestek, C. A. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/6/066002 · Cited by 204 · see citing works
Self-citationActively controlled release of Dexamethasone from neural microelectrodes in a chronic in vivo study
Boehler, C., Kleber, C., Martini, N., Xie, Y., Dryg, I., Stieglitz, T., Hofmann, U., & Asplund, M. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.03.019 · Cited by 198 · see citing works
Chronic In Vivo Evaluation of PEDOT/CNT for Stable Neural Recordings
Kozai, T. D. Y., Catt, K. A., Du, Z. J., Na, K., Srivannavit, O., Haque, R., Seymour, J. P., Wise, K. D., Yoon, E., & Cui, X. T. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2445713 · Cited by 192 · see citing works
Self-citationKozai, T. D. Y., Gugel, Z., Li, X., Gilgunn, P. J., Khilwani, R., Ozdoganlar, O. B., Fedder, G. K., Weber, D. J., & Cui, X. T. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.07.039 · Cited by 193 · see citing works
Self-citationAbiotic-biotic characterization of Pt/Ir microelectrode arrays in chronic implants
Prasad, A., Xue, Q.-S., Dieme, R., Sankar, V., Mayrand, R. C., Nishida, T., Streit, W. J., & Sanchez, J. C. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00002 · Cited by 178 · see citing works
Patel, P. R., Na, K., Zhang, H., Kozai, T. D. Y., Kotov, N. A., Yoon, E., & Chestek, C. A. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/4/046009 · Cited by 160 · see citing works
Self-citationApollo, N. V., Maturana, M. I., Tong, W., Nayagam, D. A. X., Shivdasani, M. N., Foroughi, J., Wallace, G. G., Prawer, S., Ibbotson, M. R., & Garrett, D. J. (2015) · Advanced Functional Materials · doi:10.1002/adfm.201500110 · Cited by 154 · see citing works
Microglia inflict delayed brain injury after subarachnoid hemorrhage
Schneider, U. C., Davids, A., Brandenburg, S., Müller, A., Elke, A., Magrini, S., Atangana, E. N., Turkowski, K., Finger, T., Gutenberg, A., et al. (2015) · Acta Neuropathologica · doi:10.1007/s00401-015-1440-1 · Cited by 152 · see citing works
Kozai, T. D. Y., & Vazquez, A. L. (2015) · Journal of Materials Chemistry B · doi:10.1039/c5tb00108k · Cited by 151 · see citing works
Self-citationMechanical and Biological Interactions of Implants with the Brain and Their Impact on Implant Design
Prodanov, D., & Delbeke, J. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00011 · Cited by 148 · see citing works
Chronically Implanted Intracranial Electrodes: Tissue Reaction and Electrical Changes
Campbell, A., & Wu, C. (2018) · Micromachines · doi:10.3390/mi9090430 · Cited by 144 · see citing works
Kozai, T. D. Y., Du, Z. J., Gugel, Z. V., Smith, M. A., Chase, S. M., Bodily, L., Caparosa, E. M., Friedlander, R. M., & Cui, X. T. (2014) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2014.12.010 · Cited by 135 · see citing works
Self-citationGolabchi, A., Wu, B., Cao, B., Bettinger, C. J., & Cui, X. T. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2019.119519 · Cited by 138 · see citing works
Self-citationIn Vivo Electrochemical Analysis of a PEDOT/MWCNT Neural Electrode Coating
Alba, N. A., Du, Z. J., Catt, K. A., Kozai, T. D. Y., & Cui, X. T. (2015) · Biosensors · doi:10.3390/bios5040618 · Cited by 135 · see citing works
Self-citationTranslational opportunities and challenges of invasive electrodes for neural interfaces
Shen, K., Chen, O., Edmunds, J. L., Piech, D. K., & Maharbiz, M. M. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-023-01021-5 · Cited by 143 · see citing works
Kozai, T. D. Y., Li, X., Bodily, L. M., Caparosa, E. M., Zenonos, G. A., Carlisle, D. L., Friedlander, R. M., & Cui, X. T. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.08.006 · Cited by 136 · see citing works
Self-citationMichelson, N. J., Vazquez, A. L., Eles, J. R., Salatino, J. W., Purcell, E. K., Williams, J. J., Cui, X. T., & Kozai, T. D. Y. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa9dae · Cited by 126 · see citing works
Self-citationFlexible fiber-based optoelectronics for neural interfaces
Park, S., Loke, G. Z. J., Fink, Y., & Anikeeva, P. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00710a · Cited by 134 · see citing works
Kolarcik, C. L., Catt, K., Rost, E., Albrecht, I. N., Bourbeau, D., Du, Z., Kozai, T. D. Y., Luo, X., Weber, D. J., & Tracy Cui, X. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/016008 · Cited by 126 · see citing works
Self-citationA Critical Review of Microelectrode Arrays and Strategies for Improving Neural Interfaces
Ferguson, M., Sharma, D., Ross, D., & Zhao, F. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201900558 · Cited by 124 · see citing works
Eles, J. R., Vazquez, A. L., Snyder, N. R., Lagenaur, C. F., Murphy, M. C., Kozai, T. D. Y., & Cui, X. T. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.10.054 · Cited by 116 · see citing works
Self-citationThe future of neuroscience: flexible and wireless implantable neural electronics
McGlynn, E., Nabaei, V., Ren, E., Galeote‐Checa, G., Das, R., Curia, G., & Heidari, H. (2021) · Advanced Science · doi:10.1002/advs.202002693 · Cited by 115 · see citing works
Lee, H. C., Ejserholm, F., Gaire, J., Currlin, S., Schouenborg, J., Wallman, L., Bengtsson, M., Park, K., & Otto, K. J. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa68f0 · Cited by 110 · see citing works
Dexamethasone retrodialysis attenuates microglial response to implanted probes in vivo
Kozai, T. D. Y., Jaquins‐Gerstl, A., Vazquez, A. L., Michael, A. C., & Cui, X. T. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.02.013 · Cited by 106 · see citing works
Self-citationFlexible and Implantable Microelectrodes for Chronically Stable Neural Interfaces
Shi, J., & Fang, Y. Z. (2018) · Advanced Materials · doi:10.1002/adma.201804895 · Cited by 104 · see citing works
Ultraflexible Neural Electrodes for Long-Lasting Intracortical Recording
He, F., Lycke, R., Ganji, M., Xie, C., & Luan, L. (2020) · iScience · doi:10.1016/j.isci.2020.101387 · Cited by 98 · see citing works
Recent advances in neural electrode–tissue interfaces
Woeppel, K., Yang, Q., & Cui, X. T. (2017) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2017.09.003 · Cited by 99 · see citing works
Self-citationNew Insights into Microglia–Neuron Interactions: A Neuron’s Perspective
Pósfai, B., Cserép, C., Orsolits, B., & Dénes, Á. (2019) · Neuroscience · doi:10.1016/j.neuroscience.2018.04.046 · Cited by 98 · see citing works
Electronic and Ionic Materials for Neurointerfaces
Ferro, M. D., & Melosh, N. A. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201704335 · Cited by 95 · see citing works
Li, P., Wang, L., Zhou, Y., Gan, Y., Zhu, W., Xia, Y., Jiang, X., Watkins, S. C., Vazquez, A. L., Thomson, A. W., et al. (2017) · Journal of the American Heart Association · doi:10.1161/jaha.117.006387 · Cited by 94 · see citing works
Self-citationDegenhart, A. D., Eles, J. R., Dum, R. P., Mischel, J., Smalianchuk, I., Endler, B., Ashmore, R. C., Tyler‐Kabara, E. C., Hatsopoulos, N. G., Wang, W., et al. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/4/046019 · Cited by 92 · see citing works
Self-citationIntracortical Recording Interfaces: Current Challenges to Chronic Recording Function
Gunasekera, B., Saxena, T. K., Bellamkonda, R. V., & Karumbaiah, L. (2015) · ACS Chemical Neuroscience · doi:10.1021/cn5002864 · Cited by 92 · see citing works
Two-photon imaging of chronically implanted neural electrodes: Sealing methods and new insights
Kozai, T. D. Y., Eles, J. R., Vazquez, A. L., & Cui, X. T. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2015.10.007 · Cited by 88 · see citing works
Self-citationEles, J. R., Vazquez, A. L., Kozai, T. D. Y., & Cui, X. T. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.04.043 · Cited by 85 · see citing works
Self-citationDefining the Microglia Response during the Time Course of Chronic Neurodegeneration
Vincenti, J. E., Murphy, L., Grabert, K., McColl, B. W., Cancellotti, E., Freeman, T. C., & Manson, J. C. (2016) · Journal of Virology · doi:10.1128/jvi.02613-15 · Cited by 88 · see citing works
Elastomeric and soft conducting microwires for implantable neural interfaces
Kolarcik, C. L., Luebben, S. D., Sapp, S. A., Hanner, J., Snyder, N. R., Kozai, T. D. Y., Chang, E., Nabity, J., Nabity, S. T., Lagenaur, C. F., et al. (2015) · Soft Matter · doi:10.1039/c5sm00174a · Cited by 87 · see citing works
Self-citationCody, P. A., Eles, J. R., Lagenaur, C. F., Kozai, T. D. Y., & Cui, X. T. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.01.025 · Cited by 87 · see citing works
Self-citationTissue-Compliant Neural Implants from Microfabricated Carbon Nanotube Multilayer Composite
Zhang, H., Patel, P. R., Xie, Z., Swanson, S. D., Wang, X., & Kotov, N. A. (2013) · ACS Nano · doi:10.1021/nn402074y · Cited by 88 · see citing works
Miller, E. B., Zhang, P., Ching, K., Pugh, E. N., & Burns, M. E. (2019) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1903336116 · Cited by 85 · see citing works
Electrode Materials for Chronic Electrical Microstimulation
Zheng, X. S., Tan, C., Castagnola, E., & Cui, X. T. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100119 · Cited by 86 · see citing works
Self-citationBennett, C., Mohammed, F. S., Álvarez-Ciara, A., Nguyen, M. A., Dietrich, W. D., Rajguru, S. M., Streit, W. J., & Prasad, A. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.09.040 · Cited by 85 · see citing works
A Parylene Neural Probe Array for Multi-Region Deep Brain Recordings
Wang, X., Weltman, A., Xu, H., Slingsby-Smith, Z., Lecomte, A., Scholten, K., Song, D. B., & Meng, E. F. (2020) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2020.3000235 · Cited by 83 · see citing works
Michelson, N. J., Eles, J. R., Vazquez, A. L., Ludwig, K. A., & Kozai, T. D. Y. (2018) · Journal of Neuroscience Research · doi:10.1002/jnr.24370 · Cited by 83 · see citing works
Self-citationWellman, S. M., Li, L., Yaxiaer, Y., McNamara, I., & Kozai, T. D. Y. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00493 · Cited by 76 · see citing works
Self-citationMelatonin improves quality and longevity of chronic neural recording
Golabchi, A., Wu, B., Li, X., Carlisle, D. L., Kozai, T. D. Y., Friedlander, R. M., & Cui, X. T. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.07.026 · Cited by 74 · see citing works
Self-citationLee, Y., Shin, H., Lee, D., Choi, S., Cho, I., & Seo, J. (2021) · Advanced Science · doi:10.1002/advs.202100231 · Cited by 70 · see citing works
Neuroadhesive protein coating improves the chronic performance of neuroelectronics in mouse brain
Golabchi, A., Woeppel, K. M., Li, X., Lagenaur, C. F., & Cui, X. T. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112096 · Cited by 71 · see citing works
Self-citationIn vivo spatiotemporal dynamics of NG2 glia activity caused by neural electrode implantation
Wellman, S. M., & Kozai, T. D. Y. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.02.037 · Cited by 67 · see citing works
Self-citationA comparison of insertion methods for surgical placement of penetrating neural interfaces
Thielen, B., & Meng, E. F. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abf6f2 · Cited by 72 · see citing works
Welle, E. J., Patel, P. R., Woods, J. E., Petrossians, A., della Valle, E., Vega-Medina, A., Richie, J. M., Cai, D., Weiland, J. D., & Chestek, C. A. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab8343 · Cited by 65 · see citing works
Sohal, H. S., Clowry, G. J., Jackson, A., O'Neill, A. G., & Baker, S. N. (2016) · PLoS ONE · doi:10.1371/journal.pone.0165606 · Cited by 67 · see citing works
Yuede, C. M., Lee, H. J., Restivo, J. L., Davis, T. A., Hettinger, J. C., Wallace, C. E., Young, K. L., Hayne, M. R., Bu, G., Li, C.-Z., et al. (2016) · The Journal of Experimental Medicine · doi:10.1084/jem.20151428 · Cited by 63 · see citing works
Flexible and Implantable Polyimide Aptamer-Field-Effect Transistor Biosensors
Zhao, C., Man, T., Cao, Y. F., Weiss, P. S., Monbouquette, H. G., & Andrews, A. M. (2022) · ACS Sensors · doi:10.1021/acssensors.2c01909 · Cited by 60 · see citing works
Shoffstall, A. J., Paiz, J. E., Miller, D. M., Rial, G. M., Willis, M. T., Menendez, D. M., Hostler, S. R., & Capadona, J. R. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa9f32 · Cited by 60 · see citing works
Long-term intracortical microelectrode array performance in a human: a 5 year retrospective analysis
Colachis, S. C., Dunlap, C. F., Annetta, N. V., Tamrakar, S., Bockbrader, M. A., & Friedenberg, D. A. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac1add · Cited by 64 · see citing works
Alahi, M. E. E., Liu, Y., Xu, Z., Wang, H., Wu, T., & Mukhopadhyay, S. C. (2021) · Materials Today Communications · doi:10.1016/j.mtcomm.2021.102853 · Cited by 55 · see citing works
Aptamer-functionalized neural recording electrodes for the direct measurement of cocaine in vivo
Taylor, I. M., Du, Z. J., Bigelow, E. T., Eles, J. R., Horner, A. R., Catt, K. A., Weber, S. G., Jamieson, B. G., & Cui, X. T. (2017) · Journal of Materials Chemistry B · doi:10.1039/c7tb00095b · Cited by 53 · see citing works
Self-citationXie, Y., Martini, N., Hassler, C., Kirch, R. D., Stieglitz, T., Seifert, A., & Hofmann, U. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00034 · Cited by 52 · see citing works
Coating flexible probes with an ultra fast degrading polymer to aid in tissue insertion
Lo, M.-C., Wang, S., Singh, S., Damodaran, V. B., Kaplan, H. M., Kohn, J., Shreiber, D. I., & Zahn, J. D. (2015) · Biomedical Microdevices · doi:10.1007/s10544-015-9927-z · Cited by 53 · see citing works
Khilwani, R., Gilgunn, P. J., Kozai, T. D. Y., Ong, X. C., Korkmaz, E., Gunalan, P. K., Cui, X. T., Fedder, G. K., & Özdoğanlar, O. B. (2016) · Biomedical Microdevices · doi:10.1007/s10544-016-0125-4 · Cited by 51 · see citing works
Self-citationChen, K., Wellman, S. M., Yaxiaer, Y., Eles, J. R., & Kozai, T. D. Y. (2020) · Biomaterials · doi:10.1016/j.biomaterials.2020.120526 · Cited by 46 · see citing works
Self-citationA guide towards long-term functional electrodes interfacing neuronal tissue
Renz, A. F., Reichmuth, A. M., Stauffer, F., Thompson‐Steckel, G., & Vörös, J. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aae0c2 · Cited by 50 · see citing works
Stieger, K. C., Eles, J. R., Ludwig, K. A., & Kozai, T. D. Y. (2020) · Journal of Neuroscience Research · doi:10.1002/jnr.24676 · Cited by 50 · see citing works
Self-citationEngineering strategies towards overcoming bleeding and glial scar formation around neural probes
Otte, E., Vlachos, A., & Asplund, M. (2022) · Cell and Tissue Research · doi:10.1007/s00441-021-03567-9 · Cited by 50 · see citing works
In vivo Characterization of Amorphous Silicon Carbide As a Biomaterial for Chronic Neural Interfaces
Knaack, G. L., McHail, D. G., Borda, G., Koo, B., Peixoto, N., Cogan, S. F., Dumas, T. C., & Pancrazio, J. J. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00301 · Cited by 51 · see citing works
Autotaxin and lysophospholipids in rheumatoid arthritis.
Bourgoin, S. G., & Zhao, C. (2010) · PubMed · Cited by 49 · see citing works
In vivo spatiotemporal dynamics of astrocyte reactivity following neural electrode implantation
Savya, S. P., Li, F., Lam, S., Wellman, S. M., Stieger, K. C., Chen, K., Eles, J. R., & Kozai, T. D. Y. (2022) · Biomaterials · doi:10.1016/j.biomaterials.2022.121784 · Cited by 46 · see citing works
Self-citationSzymanski, L. J., Kellis, S., Liu, C. Y., Jones, K. T., Andersen, R. A., Commins, D., Lee, B., McCreery, D. B., & Miller, C. A. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac127e · Cited by 47 · see citing works
In Vivo Imaging of Microglia With Multiphoton Microscopy
Hierro‐Bujalance, C., Bacskai, B. J., & Garcı́a-Alloza, M. (2018) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2018.00218 · Cited by 49 · see citing works
Xu, H., Weltman, A., Scholten, K., Berger, T. W., Song, D. B., & Meng, E. F. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa9451 · Cited by 46 · see citing works
Bioactive Neuroelectronic Interfaces
Adewole, D. O., Serruya, M. D., Wolf, J. A., & Cullen, D. K. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00269 · Cited by 48 · see citing works
Wellman, S. M., Cambi, F., & Kozai, T. D. Y. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.08.046 · Cited by 41 · see citing works
Self-citationEles, J. R., & Kozai, T. D. Y. (2020) · Biomaterials · doi:10.1016/j.biomaterials.2020.119767 · Cited by 43 · see citing works
Self-citationYang, Q., Wu, B., Eles, J. R., Vazquez, A. L., Kozai, T. D. Y., & Cui, X. T. (2020) · Advanced Biosystems · doi:10.1002/adbi.201900287 · Cited by 42 · see citing works
Self-citationLee, H. C., Gaire, J., Currlin, S., McDermott, M. D., Park, K., & Otto, K. J. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00513 · Cited by 40 · see citing works
Biohybrid neural interfaces: improving the biological integration of neural implants
Boulingre, M., Lara, R. P., & Green, R. A. (2023) · Chemical Communications · doi:10.1039/d3cc05006h · Cited by 39 · see citing works
Eles, J. R., Stieger, K. C., & Kozai, T. D. Y. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/abc29c · Cited by 36 · see citing works
Self-citationLi, F., Gallego, J., Tirko, N. N., Greaser, J., Bashe, D., Patel, R., Shaker, E., Valkenburg, G. E. V., Alsubhi, A. S., Wellman, S. M., et al. (2024) · Nature Communications · doi:10.1038/s41467-024-49709-9 · Cited by 35 · see citing works
Self-citationBiocompatible reference electrodes to enhance chronic electrochemical signal fidelity in vivo
Seaton, B. T., & Heien, M. L. (2021) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-021-03640-w · Cited by 36 · see citing works
Potter–Baker, K. A., & Capadona, J. R. (2015) · ACS Macro Letters · doi:10.1021/mz500743a · Cited by 35 · see citing works
Gao, W., Yan, Z., Zhou, H., Xie, Y., Wang, H., Yang, J., Yu, J., Ni, C., Liu, P., Xie, M., et al. (2025) · Journal of Nanobiotechnology · doi:10.1186/s12951-025-03573-x · Cited by 38 · see citing works
Gilmour, A. D., Woolley, A. J., Poole-Warren, L. A., Thomson, C. E., & Green, R. A. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.03.011 · Cited by 32 · see citing works
CHIME: CMOS-Hosted in vivo Microelectrodes for Massively Scalable Neuronal Recordings
Köllő, M., Rácz, R., Hanna, M.-E., Obaid, A., Angle, M. R., Wray, W., Kong, Y., Hierlemann, A. R., Müller, J., Melosh, N. A., et al. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00834 · Cited by 31 · see citing works
High‐density implantable neural electrodes and chips for massive neural recordings
Wang, L., Suo, Y., Wang, J., Wang, X., Xue, K., An, J., Sun, X., Chen, Q., Tang, X., Zhao, Y., et al. (2024) · Brain‐X · doi:10.1002/brx2.65 · Cited by 31 · see citing works
Overcoming failure: improving acceptance and success of implanted neural interfaces
Dalrymple, A. N., Jones, S. T., Fallon, J. B., Shepherd, R. K., & Weber, D. J. (2025) · Bioelectronic Medicine · doi:10.1186/s42234-025-00168-7 · Cited by 36 · see citing works
Hammer, D. X., Lozzi, A., Abliz, E., Greenbaum, N., Agrawal, A., Krauthamer, V., & Welle, C. G. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.002823 · Cited by 32 · see citing works
Sommakia, S., Gaire, J., Rickus, J. L., & Otto, K. J. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00033 · Cited by 32 · see citing works
Insertional effect following electrode implantation: an underreported but important phenomenon
Hamani, C., Davidson, B., Lipsman, N., Abrahão, A., Nestor, S. M., Rabin, J. S., Giacobbe, P., Pagano, R. L., & Campos, A. C. P. (2024) · Brain Communications · doi:10.1093/braincomms/fcae093 · Cited by 32 · see citing works
Stocking, K. C., Vazquez, A. L., & Kozai, T. D. Y. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2889832 · Cited by 29 · see citing works
Self-citationUnderstanding the Role of Innate Immunity in the Response to Intracortical Microelectrodes
Hermann, J. K., & Capadona, J. R. (2018) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.2018027166 · Cited by 30 · see citing works
Longitudinal neural and vascular structural dynamics produced by chronic microelectrode implantation
Welle, C. G., Gao, Y., Ye, M., Lozzi, A., Boretsky, A. R., Abliz, E., & Hammer, D. X. (2020) · Biomaterials · doi:10.1016/j.biomaterials.2020.119831 · Cited by 27 · see citing works
- Authors
- Kozai, T. D. Y., Vazquez, A. L., Weaver, C. L., Kim, S.-G., & Cui, X. T.
- Affiliations
- University of Pittsburgh (US)
- Corresponding author
- Kozai, Takashi D Yoshida
- Cui, X Tracy
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2012-10-17
- Volume
- 9
- Issue
- 6
- Pages
- 066001
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- PMC
- PMC3511663
- OpenAlex
- W2050826469
- Cited by
- 215
- References
- 85
- Citations by year
- 2026: 13 · 2025: 12 · 2024: 20 · 2023: 21 · 2022: 16 · 2021: 19 · 2020: 19 · 2019: 15 · 2018: 16 · 2017: 17 · 2016: 15 · 2015: 15 · 2014: 12 · 2013: 3 · 2012: 1
- FWCI
- 4.09
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Journal of Neural Engineering (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institutes of Health
- National Institute of Neurological Disorders and Stroke (5R01NS44589, R01NS044589, R01NS062019, K01NS066131)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Neurology › Neuroinflammation and Neurodegeneration Mechanisms
- Health Sciences › Medicine › Neurology › Traumatic Brain Injury and Neurovascular Disturbances
- Keywords
- microglia, microglial activation, visual cortex, two-photon microscopy, neuroprosthetics
- MeSH terms
- Algorithms, Animals, Blood-Brain Barrier, Brain, Craniotomy, Data Interpretation, Statistical, Electrodes, Implanted, Image Processing, Computer-Assisted, Mice, Transgenic, Microelectrodes, Microscopy, Visual Cortex, Microglia, Photons, Green Fluorescent Proteins, Mice
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review