CoChat

A novel porous collagen scaffold around an implantable biosensor for improving biocompatibility. I. In vitro/in vivo stability of the scaffold and in vitro sensitivity of the glucose sensor with scaffold

Ju, Young Min, Yu, Bazhang, Koob, Thomas J., Moussy, Yvonne, Moussy, Francis · 2008 · Journal of Biomedical Materials Research Part A
Cited by 70

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

A new 3D porous and biostable collagen scaffold has been developed to improve the biocompatibility of implantable glucose sensors by minimizing tissue reactions while stimulating angiogenesis around the sensors. The novel collagen scaffold was crosslinked using nordihydroguaiaretic acid (NDGA) to enhance biostability. NDGA‐treated collagen scaffolds were stable without physical deformation in the subcutaneous tissue of rats for 4 weeks. In contrast, glutaraldehyde (GA)‐treated collagen scaffolds were extremely damaged following implantation. Both types of scaffolds (NDGA‐ and GA‐crosslinked) were stable in vitro in the presence of collagenase with 70% retention of original weight after 4 weeks of incubation. The response current (i.e. sensitivity) of sensors with porous scaffolds was not significantly changed when compared with control sensors (no scaffold), while the response time (T95%) was slightly delayed after a glucose concentration increase from 5 to 15 m M. Above this range, the sensors coated with scaffolds had only a slightly lower sensitivity than the control sensors. These results indicate that we have developed a stable NDGA‐crosslinked collagen scaffold for biosensors, and that the scaffold does not impair the function of our sensor. We plan to use this scaffold to enhance the function and lifetime of the implantable biosensors by providing a controlled local environment around the sensors with the help of various drugs and growth factors (dexamethasone, VEGF, PDGF). © 2007 Wiley Periodicals, Inc. J Biomed Mater Res, 2008

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbm.a.31756

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 70

Metadata

Authors
Ju, Y. M., Yu, B., Koob, T. J., Moussy, Y., & Moussy, F.
Venue
Journal of Biomedical Materials Research Part A
Publisher
Wiley
Published
2007-12-17
Volume
87A
Issue
1
Pages
136-146
ISSN
  • 1549-3296 (ISSN-L)
  • 1552-4965
OpenAlex
W1973905294
Cited by
70
References
5
FWCI
2.25
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A novel porous collagen scaffold around an implantable biosensor for improving biocompatibility. I. In vitro/in vivo stability of the scaffold and in vitro sensitivity of the glucose sensor with scaffold. https://app.cochat.ai/papers/10.1002/jbm.a.31756
The paper
Ju, Y. M., Yu, B., Koob, T. J., Moussy, Y., & Moussy, F. (2008). A novel porous collagen scaffold around an implantable biosensor for improving biocompatibility. I. In vitro/in vivo stability of the scaffold and in vitro sensitivity of the glucose sensor with scaffold. Journal of Biomedical Materials Research Part A. https://doi.org/10.1002/jbm.a.31756

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.