CoChat

Iodine‐enhanced micro‐CT imaging: Methodological refinements for the study of the soft‐tissue anatomy of post‐embryonic vertebrates

Gignac, Paul M., Kley, Nathan J. · 2014 · Journal of Experimental Zoology Part B: Molecular and Developmental Evolution
Cited by 247

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

Abstract

The now widespread use of non‐destructive X‐ray computed tomography (CT) and micro‐CT (µCT) has greatly augmented our ability to comprehensively detail and quantify the internal hard‐tissue anatomy of vertebrates. However, the utility of X‐ray imaging for gaining similar insights into vertebrate soft‐tissue anatomy has yet to be fully realized due to the naturally low X‐ray absorption of non‐mineralized tissues. In this study, we show how a wide diversity of soft‐tissue structures within the vertebrate head—including muscles, glands, fat deposits, perichondria, dural venous sinuses, white and gray matter of the brain, as well as cranial nerves and associated ganglia—can be rapidly visualized in their natural relationships with extraordinary levels of detail using iodine‐enhanced (i‐e) µCT imaging. To date, Lugol's iodine solution (I 2 KI) has been used as a contrast agent for µCT imaging of small invertebrates, vertebrate embryos, and certain isolated parts of larger, post‐embryonic vertebrates. These previous studies have all yielded promising results, but visualization of soft tissues in smaller invertebrate and embryonic vertebrate specimens has generally been more complete than that for larger, post‐embryonic vertebrates. Our research builds on these previous studies by using high‐energy µCT together with more highly concentrated I 2 KI solutions and longer staining times to optimize the imaging and differentiation of soft tissues within the heads of post‐embryonic archosaurs (Alligator mississippiensis and Dromaius novaehollandiae). We systematically quantify the intensities of tissue staining, demonstrate the range of anatomical structures that can be visualized, and generate a partial three‐dimensional reconstruction of alligator cephalic soft‐tissue anatomy.J. Exp. Zool. (Mol. Dev. Evol.) 322B: 166–176, 2014. © 2014 Wiley Periodicals, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jez.b.22561

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 247

Metadata

Authors
Gignac, P. M., & Kley, N. J.
Venue
Journal of Experimental Zoology Part B: Molecular and Developmental Evolution
Publisher
Wiley
Published
2014-01-30
Volume
322
Issue
3
Pages
166-176
ISSN
  • 1552-5007 (ISSN-L)
  • 1552-5015
OpenAlex
W1591739839
Cited by
247
References
24
FWCI
15.79
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.