The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Steady‐state free precession magnetic resonance imaging of the heart: Comparison with segmented k‐space gradient‐echo imaging
Abstract
Steady‐state free precession imaging is a promising technique for cardiac magnetic resonance imaging (MRI), as it provides improved blood/myocardial contrast in shorter acquisition times compared with conventional gradient‐echo acquisition. The better contrast could improve observer agreement and automatic detection of cardiac contours for volumetric assessment of the ventricles, but measurements might differ from those obtained using conventional methods. We compared volumetric measurements, observer variabilities, and automatic contour detection between a steady‐state free precession imaging sequence (BFFE = balanced fast field echo) and segmented k‐space gradient‐echo acquisition (TFE = turbo field echo) in 41 subjects. With BFFE, significantly higher end‐diastolic and end‐systolic volumes and lower wall thickness, ventricular mass, ejection fraction, and wall motion were observed (P < 0.0001), while interobserver variabilities were lower and automatic contour detection of endocardial contours was more successful. We conclude that the improved image quality of BFFE reduces the observer‐dependence of volumetric measurements of the left ventricle (LV) but results in significantly different values in comparison to TFE measurements. J. Magn. Reson. Imaging 2001;14:230–236. © 2001 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
Lorenz, C., Walker, E., Morgan, V., Klein, S., & Graham, T. (1999) · Journal of Cardiovascular Magnetic Resonance · doi:10.3109/10976649909080829 · Cited by 717
Semelka, R. C., Tomei, E., Wagner, S., Mayo, J. R., Kondo, C., Suzuki, J., Caputo, G. R., & Higgins, C. B. (1990) · Radiology · doi:10.1148/radiology.174.3.2305059 · Cited by 393
Barkhausen, J., Ruehm, S. G., Goyen, M., Buck, T., Laub, G., & Debatin, J. F. (2001) · Radiology · doi:10.1148/radiology.219.1.r01ap12264 · Cited by 380
Semelka, R. C., Tomei, E., Wagner, S., Mayo, J., Caputo, G., O'Sullivan, M., Parmley, W. W., Chatterjee, K., Wolfe, C., & Higgins, C. B. (1990) · American Heart Journal · doi:10.1016/s0002-8703(05)80187-5 · Cited by 295
Evaluation of left ventricular volume and mass with breath-hold cine MR imaging.
Sakuma, H., Fujita, N., Foo, T. K., Caputo, G. R., Nelson, S. J., Hartiala, J., Shimakawa, A., & Higgins, C. B. (1993) · Radiology · doi:10.1148/radiology.188.2.8327681 · Cited by 262
van der Geest, R. J., Buller, V. G. M., Jansen, E., Lamb, H. J., Baur, L. H. B., van der Wall, E. E., Roos, A., & Reiber, J. H. C. (1997) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199709000-00019 · Cited by 216
Left Ventricular Mass and Volume: Fast Calculation with Guide-Point Modeling on MR Images
Young, A. A., Cowan, B. R., Thrupp, S. F., Hedley, W. J., & Dell’Italia, L. J. (2000) · Radiology · doi:10.1148/radiology.216.2.r00au14597 · Cited by 205
Cranney, G. B., Lotan, C. S., Dean, L., Baxley, W., Bouchard, A., & Pohost, G. M. (1990) · Circulation · doi:10.1161/01.cir.82.1.154 · Cited by 198
Left ventricular volumes measured by MR imaging.
Rehr, R. B., Malloy, C. R., Filipchuk, N. G., & Peshock, R. M. (1985) · Radiology · doi:10.1148/radiology.156.3.4023232 · Cited by 179
Buser, P. T., Auffermann, W., Holt, W. W., Wagner, S., Kircher, B., Wolfe, C., & Higgins, C. B. (1989) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(89)90304-5 · Cited by 174
Shapiro, E. P., Rogers, W. J., Beyar, R., Soulen, R. L., Zerhouni, E. A., Lima, J. A., & Weiss, J. L. (1989) · Circulation · doi:10.1161/01.cir.79.3.706 · Cited by 163
In vivo measurement of myocardial mass using nuclear magnetic resonance imaging
Keller, A., Peshock, R. M., Malloy, C. R., et al. (1986) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(86)80100-0 · Cited by 124
Fast MR imaging: techniques and clinical applications.
Haacke, E. M., & Tkach, J. A. (1990) · American Journal of Roentgenology · doi:10.2214/ajr.155.5.2120964 · Cited by 111
Measurement of left ventricular mass in vivo using gated nuclear magnetic resonance imaging
Florentine, M. S., Grosskreutz, C. L., Chang, W., Hartnett, J. A., Dunn, V. D., Ehrhardt, J. C., Fleagle, S. R., Collins, S. M., Marcus, M. L., & Skorton, D. J. (1986) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(86)80099-7 · Cited by 109
Automatic assessment of cardiac function from short-axis MRI: procedure and clinical evaluation
Nachtomy, E., Cooperstein, R., Vaturi, M., Bosak, E., Vered, Z., & AKSELROD, S. (1998) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(98)80019-2 · Cited by 43
Cited by
Alfakih, K., Plein, S., Thiele, H., Jones, T., Ridgway, J. P., & Sivananthan, M. U. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10262 · Cited by 732
Self-citationk‐t FOCUSS: A general compressed sensing framework for high resolution dynamic MRI
Jung, H., Sung, K., Nayak, K. S., Kim, E. Y., & Ye, J. C. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21757 · Cited by 669
Kissas, G., Yang, Y., Hwuang, E., Witschey, W. R., Detre, J. A., & Perdikaris, P. (2020) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2019.112623 · Cited by 647
Utility of Cardiac Magnetic Resonance Imaging in the Diagnosis of Hypertrophic Cardiomyopathy
Rickers, C., Wilke, N. M., Jerosch-Herold, M., Casey, S. A., Panse, P., Panse, N., Weil, J., Zenovich, A. G., & Maron, B. J. (2005) · Circulation · doi:10.1161/circulationaha.104.507723 · Cited by 584
Natori, S., Lai, S., Finn, J. P., Gomes, A. S., Hundley, W. G., Jerosch-Herold, M., Pearson, G., Sinha, S., Arai, A., Lima, J. A. C., et al. (2006) · American Journal of Roentgenology · doi:10.2214/ajr.04.1868 · Cited by 463
Metadata
- Authors
- Plein, S., Bloomer, T. N., Ridgway, J. P., Jones, T. R., Bainbridge, G. J., & Sivananthan, M. U.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2001-08-23
- Volume
- 14
- Issue
- 3
- Pages
- 230-236
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W1995429372
- Cited by
- 257
- References
- 17
- FWCI
- 14.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.