Water diffusion and exchange as they influence contrast enhancement
The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
The contrast‐enhanced magnetic resonance imaging (MRI) signal is rarely a direct measure of contrast concentration; rather it depends on the effect that the contrast agent has on the tissue water magnetization. To correctly interpret such studies, an understanding of the effects of water movement on the magnetic resonance (MR) signal is critical. In this review, we discuss how water diffusion within biological compartments and water exchange between these compartments affect MR signal enhancement and therefore our ability to extract physiologic information. The two primary ways by which contrast agents affect water magnetization are discussed: (1) direct relaxivity and (2) indirect susceptibility effects. For relaxivity agents, for which T1 effects usually dominate, the theory of relaxation enhancement is presented, along with a review of the relevant physiologic time constants for water movement affecting this relaxation enhancement. Experimental issues that impact accurate measurement of the relaxation enhancement are discussed. Finally, the impact of these effects on extracting physiologic information is presented. Susceptibility effects depend on the size and shape of the contrast agent, the size and shape of the compartment in which it resides, as well as the characteristics of the water movement through the resulting magnetic field inhomogeneity. Therefore, modeling of this effect is complex and is the subject of active study. However, since susceptibility effects can be much stronger than relaxivity effects in certain situations, they may be useful even without full quantitation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Paramagnetic metal complexes as water proton relaxation agents for NMR imaging: theory and design
Lauffer, R. B. (1987) · Chemical Reviews · doi:10.1021/cr00081a003 · Cited by 1,978
Reaction Rates by Nuclear Magnetic Resonance
McConnell, H. M. (1958) · The Journal of Chemical Physics · doi:10.1063/1.1744152 · Cited by 1,624
Theory of NMR signal behavior in magnetically inhomogeneous tissues: The static dephasing regime
Yablonskiy, D. A., & Haacke, E. M. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320610 · Cited by 1,198
Perfusion imaging with NMR contrast agents
Rosen, B. R., Belliveau, J. W., Vevea, J. M., & Brady, T. J. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140211 · Cited by 1,151
Mr contrast due to intravascular magnetic susceptibility perturbations
Boxerman, J. L., Hamberg, L. M., Rosen, B. R., & Weisskoff, R. M. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340412 · Cited by 1,008
Self-citationWET, a T1- and B1-Insensitive Water-Suppression Method for in Vivo Localized 1H NMR Spectroscopy
Ogg, R. J., Kingsley, R. B., & Taylor, J. S. (1994) · Journal of Magnetic Resonance, Series B · doi:10.1006/jmrb.1994.1048 · Cited by 732
Microscopic susceptibility variation and transverse relaxation: Theory and experiment
Weisskoff, R., Zuo, C. S., Boxerman, J. L., & Rosen, B. R. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310605 · Cited by 715
Self-citationNuclear Magnetic Resonance Transverse Relaxation Times of Water Protons in Skeletal Muscle
Hazlewood, C. F., Chang, D. C., Nichols, B. L., & Woessner, D. E. (1974) · Biophysical Journal · doi:10.1016/s0006-3495(74)85937-0 · Cited by 478
Chu, K. ‐. C., Xu, Y., Balschi, J. A., & Springer, C. S. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910130207 · Cited by 373
First-pass cardiac perfusion: evaluation with ultrafast MR imaging.
Atkinson, D. J., Burstein, D., & Edelman, R. R. (1990) · Radiology · doi:10.1148/radiology.174.3.2305058 · Cited by 359
Self-citationStudies of Gd‐DTPA relaxivity and proton exchange rates in tissue
Donahue, K. M., Burstein, D., Manning, W. J., & Gray, M. L. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320110 · Cited by 339
Self-citationManning, W. J., Atkinson, D. J., Grossman, W., Paulin, S., & Edelman, R. R. (1991) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(91)90754-w · Cited by 305
Water diffusion permeability of erythrocytes using an NMR technique
Conlon, T., & Outhred, R. (1972) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/0005-2736(72)90256-8 · Cited by 272
Nuclear Transfer Effects in Nuclear Magnetic Resonance Pulse Experiments
Woessner, D. E. (1961) · The Journal of Chemical Physics · doi:10.1063/1.1731931 · Cited by 227
Shames, D. M., Kuwatsuru, R., Vexler, V., Mühler, A., & Brasch, R. C. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290506 · Cited by 172
Donahue, K. M., Weisskoff, R. M., Chesler, D. A., Kwong, K. K., Bogdanov, A. A., Mandeville, J. B., & Rosen, B. R. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360608 · Cited by 165
Self-citationStudies of diffusion in random fields produced by variations in susceptibility
Majumdar, S., & Gore, J. C. (1988) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(88)90155-2 · Cited by 161
Water diffusion permeability of human erythrocytes studied by a pulsed gradient NMR technique
Andrasko, J. (1976) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(76)90038-6 · Cited by 160
MR Diffusion Imaging of the Human Brain
Chien, D., Buxton, R. B., Kwong, K. K., Brady, T. J., & Rosen, B. R. (1990) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199007000-00003 · Cited by 154
Relaxation times in systems with chemical exchange: Some exact solutions
Leigh, J. S. (1971) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(71)90040-0 · Cited by 154
Labadie, C., Lee, J. H., Vétek, G., & SPRINGER, C. S. J. (1994) · Journal of Magnetic Resonance Series B · doi:10.1006/jmrb.1994.1109 · Cited by 119
Nuclear magnetic resonance transverse relaxation in muscle water
Fung, B. M., & Puon, P. S. (1981) · Biophysical Journal · doi:10.1016/s0006-3495(81)84870-9 · Cited by 103
Wedeking, P. W., Sotak, C. H., Telser, J., Kumar, K., Chang, C. A., & Tweedle, M. F. (1992) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(92)90378-d · Cited by 97
Quantification of regional blood volumes by rapid T1 mapping
Schwarzbauer, C., Syha, J., & Haase, A. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290521 · Cited by 95
Wendland, M. F., Saeed, M., Yu, K. K., Roberts, T. P. L., Lauerma, K., Derugin, N., Varadarajan, J., Watson, A. D., & Higgins, C. B. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320307 · Cited by 88
Judd, R. M., Atalay, M. K., Rottman, G. A., & Zerhouni, E. A. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330211 · Cited by 74
Schwickert, H. C., Roberts, T. P. L., Shames, D. M., van Dijke, C. F., Disston, A. R., Mühler, A., Mann, J. S., & Brasch, R. C. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340609 · Cited by 69
Moseley, M. E., Chew, W. M., White, D. L., Kucharczyk, J. R., Litt, L. L., Derugin, N., DUPON, J. W., Brasch, R. C., & Norman, D. M. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910230104 · Cited by 65
Quantification of tissue plasma volume in the rat by contrast‐enhanced magnetic resonance imaging
Kuwatsuru, R., Shames, D. M., Mühler, A., Mintorovitch, J., Vexler, V. S., Mann, J. S., Cohn, F., Price, D., Huberty, J. P., & Brasch, R. C. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300112 · Cited by 64
Cited by
Tofts, P. S., Brix, G., Buckley, D. L., Evelhoch, J. L., Henderson, E., Knopp, M. V., Larsson, H. B. W., Lee, T.-Y., Mayr, N. A., Parker, G. J. M., et al. (1999) · Journal of Magnetic Resonance Imaging · doi:10.1002/(sici)1522-2586(199909)10:3<223::aid-jmri2>3.0.co;2-s · Cited by 3,143
Self-citationQuantitative susceptibility mapping (QSM): Decoding MRI data for a tissue magnetic biomarker
Wang, Y., & Liu, T. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25358 · Cited by 878
Friedrich, M. G., Strohm, O., Schulz-Menger, J., Marciniak, H., Luft, F. C., & Dietz, R. (1998) · Circulation · doi:10.1161/01.cir.97.18.1802 · Cited by 558
Methodology of brain perfusion imaging
Barbier, E. L., Lamalle, L., & Décorps, M. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1073 · Cited by 404
Saturation recovery single‐shot acquisition (SASHA) for myocardial T1 mapping
Chow, K., Flewitt, J. A., Green, J. D., Pagano, J. J., Friedrich, M. G., & Thompson, R. B. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24878 · Cited by 396
Metadata
- Authors
- Donahue, K. M., Weisskoff, R. M., & Burstein, D.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 1997-01
- Volume
- 7
- Issue
- 1
- Pages
- 102-110
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2171072107
- Cited by
- 270
- References
- 29
- FWCI
- 11.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.