The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Functional MRI of the lung using hyperpolarized 3‐helium gas
Open accessAbstract
Lung imaging has traditionally relied on x‐ray methods, since proton MRI is limited to some extent by low proton density in the lung parenchyma and static field inhomogeneities in the chest. The relatively recent introduction of MRI of hyperpolarized noble gases has led to a rapidly evolving field of pulmonary MRI, revealing functional information of the lungs, which were hitherto unattainable. This review article briefly describes the physical background of the technology, and subsequently focuses on its clinical applications. Four different techniques that have been used in various human investigations are discussed: ventilation distribution, ventilation dynamics, and small airway evaluation using diffusion imaging and oxygen uptake assessment. J. Magn. Reson. Imaging 2004;20:540–554. © 2004 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spin-exchange optical pumping of noble-gas nuclei
Walker, T. G., & Happer, W. (1997) · Reviews of Modern Physics · doi:10.1103/revmodphys.69.629 · Cited by 1,444
Biological magnetic resonance imaging using laser-polarized 129Xe
Albert, M. S., Cates, G. D., Driehuys, B., Happer, W., Saam, B., Springer, C. S., & Wishnia, A. (1994) · Nature · doi:10.1038/370199a0 · Cited by 1,050
Automatic lung segmentation for accurate quantitation of volumetric X-ray CT images
Hu, S., Hoffman, E. A., & Reinhardt, J. M. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.929615 · Cited by 940
Cystic fibrosis: scoring system with thin-section CT.
Bhalla, M., Turcios, N., Aponte, V, Jenkins, M., Leitman, B. S., McCauley, D. I., & Naidich, D. P. (1991) · Radiology · doi:10.1148/radiology.179.3.2027992 · Cited by 726
Kastler, A. (1950) · Journal de Physique et le Radium · doi:10.1051/jphysrad:01950001106025500 · Cited by 618
Happer, W., Miron, E., Schaefer, S., Schreiber, D., van Wijngaarden, W. A., & Zeng, X. (1984) · Physical Review A · doi:10.1103/physreva.29.3092 · Cited by 468
Nuclear Magnetic Resonance of Laser-Polarized Noble Gases in Molecules, Materials, and Organisms
Goodson, B. M. (2002) · Journal of Magnetic Resonance · doi:10.1006/jmre.2001.2341 · Cited by 457
Nuclear Polarization inHe3Gas Induced by Optical Pumping and Dipolar Exchange
Bouchiat, M. A., Carver, T. R., & Varnum, C. M. (1960) · Physical Review Letters · doi:10.1103/physrevlett.5.373 · Cited by 406
MRI of the lungs using hyperpolarized noble gases
Möller, H. E., Chen, X. J., Saam, B. T., Hagspiel, K. D., Johnson, G. A., Altes, T. A., de Lange, E. E., & Kauczor, H. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10173 · Cited by 397
Self-citationRapid NMR imaging of dynamic processes using the FLASII technique
Frahm, J., Haase, A., & Matthaei, D. (1986) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910030217 · Cited by 381
MR fluoroscopy: Technical feasibility
Riederer, S. J., Tasciyan, T., Farzaneh, F., Lee, J. N., Wright, R. C., & Herfkens, R. J. (1988) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910080102 · Cited by 370
MR Imaging with Hyperpolarized 3He Gas
Middleton, H., Black, R. D., Saam, B., Cates, G. D., Cofer, G. P., Guenther, R., Happer, W., Hedlund, L. W., Alan Johnson, G., Juvan, K., et al. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330219 · Cited by 358
Samee, S., Altes, T., Powers, P., de Lange, E. E., Knight-Scott, J., Rakes, G., Mugler III, J. P., Ciambotti, J. M., Alford, B. A., Brookeman, J. R., et al. (2003) · Journal of Allergy and Clinical Immunology · doi:10.1067/mai.2003.1544 · Cited by 324
Self-citationHyperpolarized 3He MR lung ventilation imaging in asthmatics: Preliminary findings
Altes, T. A., Powers, P. L., Knight‐Scott, J., Rakes, G., Platts‐Mills, T. A. E., de Lange, E. E., Alford, B. A., Mugler, J. P., & Brookeman, J. R. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1054 · Cited by 318
Self-citationQuantitative Computed Tomography Detects Air Trapping due to Asthma
Newman, K. B., Lynch, D. A., Newman, L. S., Ellegood, D., & Newell, J. D. (1994) · Chest · doi:10.1378/chest.106.1.105 · Cited by 251
Computed tomography of the lungs in asthma: influence of disease severity and etiology.
Paganin, F., Séneterre, E., Chanez, P., Daurés, J. P., Bruel, J. M., Michel, F. B., & Bousquet, J. (1996) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.153.1.8542102 · Cited by 246
Nuclear magnetic resonance imaging with hyperpolarised helium-3
Ebert, M., Grossmann, T., Heil, W., Otten, E. W., Surkau, R., Thelen, M., Leduc, M., Bachert, P., Knopp, M. V., & Schad, L. R. (1996) · The Lancet · doi:10.1016/s0140-6736(96)90940-x · Cited by 186
Quantification of Regional Intrapulmonary Oxygen Partial Pressure Evolution during Apnea by 3He MRI
Deninger, A. J., Eberle, B., Ebert, M., Großmann, T., Heil, W., Kauczor, H.-U., Lauer, L., Markstaller, K., Otten, E., Schmiedeskamp, J., et al. (1999) · Journal of Magnetic Resonance · doi:10.1006/jmre.1999.1902 · Cited by 184
Self-citationPark, C. S., Müller, N. L., Worthy, S. A., Kim, J. S., Awadh, N., & Fitzgerald, M. (1997) · Radiology · doi:10.1148/radiology.203.2.9114089 · Cited by 179
Expiratory CT scans for chronic airway disease: correlation with pulmonary function test results.
Lucidarme, O., Coche, E., Cluzel, P., Mourey-Gerosa, I., Howarth, N., & Greniér, P. (1998) · American Journal of Roentgenology · doi:10.2214/ajr.170.2.9456933 · Cited by 130
Chronic obstructive pulmonary disease
Madison, J. M., & Irwin, R. S. (1998) · The Lancet · doi:10.1016/s0140-6736(97)11081-9 · Cited by 118
Analysis of intrapulmonary O2concentration by MR imaging of inhaled hyperpolarized helium-3
Eberle, B., Weiler, N., Markstaller, K., Kauczor, H. ‐., Deninger, A. J., Ebert, M., Grossmann, T., Heil, W., Lauer, L., Roberts, T. P. L., et al. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.87.6.2043 · Cited by 108
Self-citationLow-Field MRI of Laser Polarized Noble Gas
Tseng, C.-H., Wong, G. P., Pomeroy, V. R., Mair, R. W., Hinton, D. P., Hoffmann, D., Stoner, R. E., Hersman, F. W., Cory, D. G., & Walsworth, R. L. (1998) · Physical Review Letters · doi:10.1103/physrevlett.81.3785 · Cited by 105
Bronchiolitis Obliterans: Pathogenesis, Prevention, and Management
Paradis, I. L. (1998) · The American Journal of the Medical Sciences · doi:10.1016/s0002-9629(15)40301-5 · Cited by 70
Suga, K., Tsukuda, T., Awaya, H., Matsunaga, N., Sugi, K., & Esato, K. (2000) · CHEST Journal · doi:10.1378/chest.117.6.1646 · Cited by 47
Distal Airways in Humans: Dynamic Hyperpolarized3He MR Imaging—Feasibility
Tooker, A., Hong, K. S., McKinstry, E. L., Costello, P., Jolesz, F. A., & Albert, M. S. (2003) · Radiology · doi:10.1148/radiol.2272012146 · Cited by 38
Donnelly, L. F., Gelfand, M. J., Brody, A. S., & Wilmott, R. W. (1997) · Pediatric Radiology · doi:10.1007/s002470050272 · Cited by 37
Critical evaluation of lung scintigraphy in cystic fibrosis: study of 113 patients.
PIEPSZ, A., Wetzburger, C., Spehl, M., et al. (1980) · PubMed · Cited by 27
Cited by
Chemistry of MRI Contrast Agents: Current Challenges and New Frontiers
Wahsner, J., Gale, E. M., Rodríguez-Rodríguez, A., & Caravan, P. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00363 · Cited by 1,603
NMR survey of reflected Brownian motion
Grebenkov, D. S. (2007) · Reviews of Modern Physics · doi:10.1103/revmodphys.79.1077 · Cited by 421
Evaluation of Asthma With Hyperpolarized Helium-3 MRI
de Lange, E. E., Altes, T. A., Patrie, J. T., Gaare, J. D., Knake, J. J., Mugler, J. P., & Platts-Mills, T. A. (2006) · Chest · doi:10.1378/chest.130.4.1055 · Cited by 279
Self-citationControlled pulmonary drug and gene delivery using polymeric nano-carriers
Beck-Broichsitter, M., Merkel, O. M., & Kissel, T. (2012) · Journal of Controlled Release · doi:10.1016/j.jconrel.2011.12.004 · Cited by 200
Computed tomographic imaging of the airways: relationship to structure and function
de Jong, P. A., Müller, N. L., Paré, P. D., & Coxson, H. O. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00007105 · Cited by 171
Metadata
- Authors
- van Beek, E. J. R., Wild, J. M., Kauczor, H., Schreiber, W., Mugler, J. P., & de Lange, E. E.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2004-09-23
- Volume
- 20
- Issue
- 4
- Pages
- 540-554
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2128154647
- Cited by
- 260
- References
- 28
- FWCI
- 11.26
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.