The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Effects of signal‐to‐noise ratio on the accuracy and reproducibility of diffusion tensor imaging–derived fractional anisotropy, mean diffusivity, and principal eigenvector measurements at 1.5T
Open accessAbstract
Purpose: To develop an experimental protocol to calculate the precision and accuracy of fractional anisotropy (FA), mean diffusivity (MD), and the orientation of the principal eigenvector (PEV) as a function of the signal‐to‐noise ratio (SNR) in vivo. Materials and Methods: A healthy male volunteer was scanned in three separate scanning sessions, yielding a total of 45 diffusion tensor imaging (DTI) scans. To provide FA, MD, and PEV as a function of SNR, sequential scans from a scan session were grouped into nonintersecting sets. Analysis of the accuracy and precision of the DTI‐derived contrasts was done in both a voxel‐wise and region of interest (ROI)‐based manner. Results: An upward bias of FA and no significant bias in MD were present as SNR decreased, confirming results from simulation‐based studies. Notably, while the precision of the PEV became worse at low SNR, no bias in the PEV orientation was observed. Overall, an accurate and precise quantification of FA values in GM requires substantially more SNR than the quantification of white matter (WM) FA values Conclusion: This study provides guidance for FA, MD, and PEV quantification and a means to investigate the minimal detectable differences within and across scan sessions as a function of SNR. J. Magn. Reson. Imaging 2007;26:756–767. © 2007 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jenkinson, M., Bannister, P., Brady, M., & Smith, S. (2002) · NeuroImage · doi:10.1006/nimg.2002.1132 · Cited by 11,888
Self-citationMR diffusion tensor spectroscopy and imaging
Basser, P. J., Mattiello, J., & LeBihan, D. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)80775-1 · Cited by 5,970
The basis of anisotropic water diffusion in the nervous system—A technical review.
Beaulieu, C. (2002) · NMR in Biomedicine · doi:10.1002/nbm.782 · Cited by 4,628
Basser, P. J., & Pierpaoli, C. (1996) · Journal of Magnetic Resonance, Series B · doi:10.1006/jmrb.1996.0086 · Cited by 4,306
Diffusion tensor MR imaging of the human brain
Pierpaoli, C., Jezzard, P., Basser, P. J., Barnett, A., & Di Chiro, G. (1996) · Radiology · doi:10.1148/radiology.201.3.8939209 · Cited by 2,664
The rician distribution of noisy mri data
Gudbjartsson, H., & Patz, S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340618 · Cited by 2,494
Toward a quantitative assessment of diffusion anisotropy
Pierpaoli, C., & Basser, P. J. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360612 · Cited by 2,405
Fiber tracking: principles and strategies – a technical review
Mori, S., & van Zijl, P. C. M. (2002) · NMR in Biomedicine · doi:10.1002/nbm.781 · Cited by 2,024
Self-citationTracking neuronal fiber pathways in the living human brain
Conturo, T. E., Lori, N. F., Cull, T. S., Akbudak, E., Snyder, A. Z., Shimony, J. S., McKinstry, R. C., Burton, H., & Raichle, M. E. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.18.10422 · Cited by 1,774
Diffusion‐tensor MRI: theory, experimental design and data analysis – a technical review
Basser, P. J., & Jones, D. K. (2002) · NMR in Biomedicine · doi:10.1002/nbm.783 · Cited by 1,478
Cited by
The B‐matrix must be rotated when correcting for subject motion in DTI data
Leemans, A., & Jones, D. K. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21890 · Cited by 1,281
Diffusion tensor imaging and beyond
Tournier, J., Mori, S., & Leemans, A. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22924 · Cited by 921
Self-citationA hitchhiker's guide to diffusion tensor imaging
Soares, J. M., Marques, P., Alves, V., & Sousa, N. (2013) · Frontiers in Neuroscience · doi:10.3389/fnins.2013.00031 · Cited by 893
Diffusion Tensor MR Imaging and Fiber Tractography: Technical Considerations
Mukherjee, P., Chung, S. W., Berman, J. I., Hess, C. P., & Henry, R. G. (2008) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1052 · Cited by 390
MR diffusion kurtosis imaging for neural tissue characterization
Wu, E. X., & Cheung, M. M. (2010) · NMR in Biomedicine · doi:10.1002/nbm.1506 · Cited by 346
Taoka, T., Ito, R., Nakamichi, R., Kamagata, K., Sakai, M., Kawai, H., Nakane, T., Abe, T., Ichikawa, K., Kikuta, J., et al. (2022) · Japanese Journal of Radiology · doi:10.1007/s11604-021-01187-5 · Cited by 290
Effect of head impacts on diffusivity measures in a cohort of collegiate contact sport athletes
McAllister, T. W., Ford, J. C., Flashman, L. A., Maerlender, A., Greenwald, R. M., Beckwith, J. G., Bolander, R. P., Tosteson, T. D., Turco, J. H., Raman, R., et al. (2014) · Neurology · doi:10.1212/01.wnl.0000438220.16190.42 · Cited by 252
Roalf, D. R., Quarmley, M., Elliott, M. A., Satterthwaite, T. D., Vandekar, S. N., Ruparel, K., Gennatas, E. D., Calkins, M. E., Moore, T. M., Hopson, R., et al. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2015.10.068 · Cited by 199
Thomas, C., & Baker, C. I. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.03.069 · Cited by 204
Schilling, K. G., Rheault, F., Petit, L., Hansen, C. B., Nath, V., Yeh, F.-C., Girard, G., Barakovic, M., Rafael-Patino, J., Yu, T., et al. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118502 · Cited by 182
Self-citationClerx, L., Visser, P. J., Verhey, F., & Aalten, P. (2012) · Journal of Alzheimer s Disease · doi:10.3233/jad-2011-110797 · Cited by 132
The impact of in-scanner head motion on structural connectivity derived from diffusion MRI
Baum, G. L., Roalf, D. R., Cook, P. A., Ciric, R., Rosen, A. F. G., Xia, C., Elliott, M. A., Ruparel, K., Verma, R., Tunç, B., et al. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.02.041 · Cited by 116
Diffusion-MRI in neurodegenerative disorders
Goveas, J., O’Dwyer, L., Mascalchi, M., Cosottini, M., Diciotti, S., De Santis, S., Passamonti, L., Tessa, C., Toschi, N., & Giannelli, M. (2015) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2015.04.006 · Cited by 104
Relationships between tissue microstructure and the diffusion tensor in simulated skeletal muscle
Berry, D. B., Regner, B., Galinsky, V., Ward, S. R., & Frank, L. R. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26993 · Cited by 86
Zhang, F., Wu, Y., Norton, I., Rathi, Y., Golby, A. J., & O'Donnell, L. J. (2019) · Human Brain Mapping · doi:10.1002/hbm.24579 · Cited by 89
How does angular resolution affect diffusion imaging measures?
Zhan, L., Leow, A. D., Jahanshad, N., Chiang, M.-C., Barysheva, M., Lee, A. D., Toga, A. W., McMahon, K. L., de Zubicaray, G. I., Wright, M. J., et al. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.09.057 · Cited by 79
Schilling, K. G., Archer, D., Yeh, F.-C., Rheault, F., Cai, L. Y., Hansen, C., Yang, Q., Ramdass, K., Shafer, A. T., Resnick, S. M., et al. (2022) · Brain Structure and Function · doi:10.1007/s00429-022-02503-z · Cited by 78
Self-citationAcute effects of modafinil on brain resting state networks in young healthy subjects
Esposito, R., Cilli, F., Pieramico, V., Ferretti, A., Macchia, A., Tommasi, M., Saggino, A., Ciavardelli, D., Manna, A., Navarra, R., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0069224 · Cited by 66
Chung, A. W., Seunarine, K. K., & Clark, C. A. (2016) · Human Brain Mapping · doi:10.1002/hbm.23328 · Cited by 63
Automated tractography of the cingulate bundle in Alzheimer's disease: a multicenter DTI study
Fischer, F. U., Scheurich, A., Wegrzyn, M., Schermuly, I., Bokde, A. L. W., Klöppel, S., Pouwels, P. J. W., Teipel, S., Yakushev, I., & Fellgiebel, A. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23621 · Cited by 34
Kreilkamp, B. A. K., Lisanti, L., Glenn, G. R., Wieshmann, U. C., Das, K., Marson, A. G., & Keller, S. S. (2019) · NeuroImage: Clinical · doi:10.1016/j.nicl.2019.102024 · Cited by 27
Richardson, S., Siow, B., Panagiotaki, E., Schneider, T., Lythgoe, M. F., & Alexander, D. C. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25012 · Cited by 27
Crombé, A., Nicolas, R., Richard, N., Tourdias, T., & Hiba, B. (2022) · Scientific Reports · doi:10.1038/s41598-022-15511-0 · Cited by 13
Metadata
- Authors
- Farrell, J. A. D., Landman, B. A., Jones, C. K., Smith, S. A., Prince, J. L., van Zijl, P. C. M., & Mori, S.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2007-08-29
- Volume
- 26
- Issue
- 3
- Pages
- 756-767
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2066931954
- Cited by
- 357
- References
- 41
- FWCI
- 10.03
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.