The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
MR thermometry
Open accessAbstract
Minimally invasive thermal therapy as local treatment of benign and malignant diseases has received increasing interest in recent years. Safety and efficacy of the treatment require accurate temperature measurement throughout the thermal procedure. Noninvasive temperature monitoring is feasible with magnetic resonance (MR) imaging based on temperature‐sensitive MR parameters such as the proton resonance frequency (PRF), the diffusion coefficient (D), T 1 and T 2 relaxation times, magnetization transfer, the proton density, as well as temperature‐sensitive contrast agents. In this article the principles of temperature measurements with these methods are reviewed and their usefulness for monitoring in vivo procedures is discussed. Whereas most measurements give a temperature change relative to a baseline condition, temperature‐sensitive contrast agents and spectroscopic imaging can provide absolute temperature measurements. The excellent linearity and temperature dependence of the PRF and its near independence of tissue type have made PRF‐based phase mapping methods the preferred choice for many in vivo applications. Accelerated MRI imaging techniques for real‐time monitoring with the PRF method are discussed. Special attention is paid to acquisition and reconstruction methods for reducing temperature measurement artifacts introduced by tissue motion, which is often unavoidable during in vivo applications. J. Magn. Reson. Imaging 2008;27:376–390. © 2008 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Principles of Nuclear Magnetism
Abragam, A., & Hebel, L. C. (1961) · American Journal of Physics · doi:10.1119/1.1937646 · Cited by 15,792
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,286
Relaxation Effects in Nuclear Magnetic Resonance Absorption
Bloembergen, N., Purcell, E. M., & Pound, R. V. (1948) · Physical Review · doi:10.1103/physrev.73.679 · Cited by 6,528
Thermal dose determination in cancer therapy
Sapareto, S. A., & Dewey, W. C. (1984) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(84)90379-1 · Cited by 2,498
Moseley, M. E., Cohen, Y., Mintorovitch, J., Chileuitt, L., Shimizu, H., Kucharczyk, J., Wendland, M. F., & Weinstein, P. R. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140218 · Cited by 1,644
Schenck, J. F. (1996) · Medical Physics · doi:10.1118/1.597854 · Cited by 1,522
Bottomley, P. A., Foster, T. H., Argersinger, R. E., & Pfeifer, L. M. (1984) · Medical Physics · doi:10.1118/1.595535 · Cited by 1,192
Némethy, G., & Scheraga, H. A. (1962) · The Journal of Chemical Physics · doi:10.1063/1.1732472 · Cited by 1,108
A precise and fast temperature mapping using water proton chemical shift
Ishihara, Y., Calderon, A., Watanabe, H., Okamoto, K., Suzuki, Y., Kuroda, K., & Suzuki, Y. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340606 · Cited by 1,027
Basic principles of thermal dosimetry and thermal thresholds for tissue damage from hyperthermia
Dewhirst, M. W., Viglianti, B. L., Lora-Michiels, M., Hanson, M., & Hoopes, P. J. (2003) · International Journal of Hyperthermia · doi:10.1080/0265673031000119006 · Cited by 1,014
Proton Resonance Shift of Water in the Gas and Liquid States
Hindman, J. C. (1966) · The Journal of Chemical Physics · doi:10.1063/1.1726676 · Cited by 661
PATHOLOGIC ANALYSIS OF PHOTOTHERMAL AND PHOTOMECHANICAL EFFECTS OF LASER–TISSUE INTERACTIONS
Thomsen, S. (1991) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1991.tb09897.x · Cited by 585
Temperature mapping with MR imaging of molecular diffusion: application to hyperthermia.
Le Bihan, D., Delannoy, J., & Levin, R. L. (1989) · Radiology · doi:10.1148/radiology.171.3.2717764 · Cited by 493
Bottomley, P. A., & Andrew, E. R. (1978) · Physics in Medicine & Biology · doi:10.1088/0031-9155/23/4/006 · Cited by 407
Salomir, R., de Senneville, B. D., & Moonen, C. T. (2003) · Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering · doi:10.1002/cmr.b.10083 · Cited by 389
Woessner, D. E., Zhang, S., Merritt, M. E., & Sherry, A. D. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20408 · Cited by 375
Ex vivo tissue‐type independence in proton‐resonance frequency shift MR thermometry
Peters, R. T. D., Hinks, R. S., & Henkelman, R. M. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400316 · Cited by 320
MR temperature mapping of focused ultrasound surgery
Cline, H. E., Hynynen, K., Hardy, C. J., Watkins, R. D., Schenck, J. F., & Jolesz, F. A. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310608 · Cited by 260
The theory of rate processes in biology and medicine
Radda, G. K. (1975) · Biochemical Education · doi:10.1016/0307-4412(75)90053-9 · Cited by 250
McDannold, N. J. (2005) · International Journal of Hyperthermia · doi:10.1080/02656730500096073 · Cited by 213
Vigen, K. K., Daniel, B. L., Pauly, J. M., & Butts, K. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10608 · Cited by 176
MRI Thermometry Based on PARACEST Agents
Zhang, S., Malloy, C. R., & Sherry, A. D. (2005) · Journal of the American Chemical Society · doi:10.1021/ja053799t · Cited by 173
The Estimation of Local Brain Temperature by in Vivo1H Magnetic Resonance Spectroscopy
Cady, E. B., D'Souza, P. C., Penrice, J., & Lorek, A. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330620 · Cited by 169
Real‐time magnetic resonance imaging of laser heat deposition in tissue
Bleier, A. R., Jolesz, F. A., Cohen, M. S., Weisskoff, R. M., Dalcanton, J. J., Higuchi, N., Feinberg, D. A., Rosen, B. R., McKinstry, R. C., & Hushek, S. G. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910210116 · Cited by 150
Temperature dependence of proton relaxation times in vitro
Nelson, T. R., & Tung, S. M. (1987) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(87)90020-8 · Cited by 145
Analysis of changes in MR properties of tissues after heat treatment
Graham, S. J., Stanisz, G. J., Kecojević, A., Bronskill, M. J., & Henkelman, R. M. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199912)42:6<1061::aid-mrm10>3.0.co;2-t · Cited by 142
Mack, M. G., Straub, R., Eichler, K., Söllner, O., Lehnert, T., & Vogl, T. J. (2004) · Radiology · doi:10.1148/radiol.2332030454 · Cited by 120
Modeling and observation of temperature changes in Vivo using MRI
Young, I., Hand, J. W., Oatridge, A., & Prior, M. V. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320311 · Cited by 109
Heat-activated Liposomal MR Contrast Agent: Initial in Vivo Results in Rabbit Liver and Kidney
McDannold, N. J., Fossheim, S. L., Rasmussen, H., Martin, H. R., Vykhodtseva, N. I., & Hynynen, K. (2004) · Radiology · doi:10.1148/radiol.2303021713 · Cited by 73
YOUNG, I. R., Hajnal, J. V., Roberts, I. G., Ling, J., Hill-Cottingham, R. J., Oatridge, A., & Wilson, J. A. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360307 · Cited by 66
Paramagnetic thermosensitive liposomes for MR-thermometry
Lindner, L. H., Reinl, H. M., Schlemmer, M., Stahl, R., & Peller, M. (2005) · International Journal of Hyperthermia · doi:10.1080/02656730500158410 · Cited by 64
Optimization of self‐reference thermometry using complex field estimation
Kuroda, K., Kokuryo, D., Kumamoto, E., Suzuki, K., Matsuoka, Y., & Keserci, B. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21016 · Cited by 59
Shmatukha, A. V., & Bakker, C. J. G. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/18/015 · Cited by 24
A new temperature‐sensitive contrast mechanism for MRI: Curie temperature transition‐based imaging
Settecase, F., Sussman, M. S., & Roberts, T. P. L. (2007) · Contrast Media & Molecular Imaging · doi:10.1002/cmmi.120 · Cited by 22
Cited by
Xu, L., Gutbrod, S. R., Bonifas, A. P., Su, Y., Sulkin, M. S., Lu, N., Chung, H.-J., Jang, K.-I., Liu, Z., Ying, M., et al. (2014) · Nature Communications · doi:10.1038/ncomms4329 · Cited by 634
Ultrasound Neuromodulation: A Review of Results, Mechanisms and Safety
Blackmore, J., Shrivastava, S., Sallet, J., Butler, C. R., & Cleveland, R. O. (2019) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2018.12.015 · Cited by 556
Image-guided radiotherapy: from current concept to future perspectives
Jaffray, D. A. (2012) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2012.194 · Cited by 496
Tay, Z. W., Chandrasekharan, P., Chiu-Lam, A., Hensley, D. W., Dhavalikar, R., Zhou, X. Y., Yu, E. Y., Goodwill, P. W., Zheng, B., Rinaldi, C., et al. (2018) · ACS Nano · doi:10.1021/acsnano.8b00893 · Cited by 459
Transcranial focused ultrasound stimulation of human primary visual cortex
Lee, W., Kim, H.-C., Jung, Y., Chung, Y. A., Song, I.-U., Lee, J.-H., & Yoo, S.-S. (2016) · Scientific Reports · doi:10.1038/srep34026 · Cited by 415
Metadata
- Authors
- Rieke, V., & Butts Pauly, K.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2008-01-24
- Volume
- 27
- Issue
- 2
- Pages
- 376-390
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W4233326001
- Cited by
- 1,108
- References
- 34
- FWCI
- 30.34
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.