The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Fat and water magnetic resonance imaging
Abstract
A wide variety of fat suppression and water–fat separation methods are used to suppress fat signal and improve visualization of abnormalities. This article reviews the most commonly used techniques for fat suppression and fat–water imaging including 1) chemically selective fat suppression pulses “FAT‐SAT”; 2) spatial‐spectral pulses (water excitation); 3) short inversion time (TI) inversion recovery (STIR) imaging; 4) chemical shift based water–fat separation methods; and finally 5) fat suppression and balanced steady‐state free precession (SSFP) sequences. The basic physical background of these techniques including their specific advantages and disadvantages is given and related to clinical applications. This enables the reader to understand the reasons why some fat suppression methods work better than others in specific clinical settings. J. Magn. Reson. Imaging 2010;31:4–18. © 2009 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Nonalcoholic Fatty Liver Disease
Marchesini, G., Brizi, M., Bianchi, G., Tomassetti, S., Bugianesi, E., Lenzi, M., McCullough, A. J., Natale, S., Forlani, G., & Melchionda, N. (2001) · Diabetes · doi:10.2337/diabetes.50.8.1844 · Cited by 2,581 · cited 1×
“It is also related to the metabolic syndrome, which includes obesity and type II diabetes (69,71).”
BackgroundSimple proton spectroscopic imaging.
Dixon, W. T. (1984) · Radiology · doi:10.1148/radiology.153.1.6089263 · Cited by 2,276
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Sodickson, D. K., & Manning, W. J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380414 · Cited by 2,142
Chitturi, S., Abeygunasekera, S., Farrell, G. C., Holmes-Walker, J., Hui, J. M., Fung, C., Karim, R., Lin, R., Samarasinghe, D., Liddle, C., et al. (2002) · Hepatology · doi:10.1053/jhep.2002.30692 · Cited by 1,122
Rieke, V., & Butts Pauly, K. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21265 · Cited by 1,108
1H NMR chemical shift selective (CHESS) imaging
Haase, A., Frahm, J., Hanicke, W., & Matthaei, D. (1985) · Physics in Medicine and Biology · doi:10.1088/0031-9155/30/4/008 · Cited by 1,062
Reeder, S. B., Pineda, A. R., Wen, Z., Shimakawa, A., Yu, H., Brittain, J. H., Gold, G. E., Beaulieu, C. H., & Pelc, N. J. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20624 · Cited by 706
Self-citationYu, H., Shimakawa, A., McKenzie, C. A., Brodsky, E., Brittain, J. H., & Reeder, S. B. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21737 · Cited by 694
Self-citationThree‐point dixon technique for true water/fat decomposition with B0 inhomogeneity correction
Glover, G. H., & Schneider, E. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910180211 · Cited by 687
Cited by
Heymsfield, S. B., Gonzalez, M. C., Lu, J., Jia, G., & Zheng, J. (2015) · Proceedings of the Nutrition Society · doi:10.1017/s0029665115000129 · Cited by 483
Kopp, C., Linz, P., Dahlmann, A., Hammon, M., Jantsch, J., Müller, D. N., Schmieder, R. E., Cavallaro, A., Eckardt, K.-U., Uder, M., et al. (2013) · Hypertension · doi:10.1161/hypertensionaha.111.00566 · Cited by 393
Fat-Suppression Techniques for 3-T MR Imaging of the Musculoskeletal System
Del Grande, F., Santini, F., Herzka, D. A., Aro, M. R., Dean, C. W., Gold, G. E., & Carrino, J. A. (2014) · RadioGraphics · doi:10.1148/rg.341135130 · Cited by 370
Skin Sodium Concentration Correlates with Left Ventricular Hypertrophy in CKD
Schneider, M. P., Raff, U., Kopp, C., Scheppach, J. B., Toncar, S., Wanner, C., Schlieper, G., Saritas, T., Floege, J., Schmid, M., et al. (2017) · Journal of the American Society of Nephrology · doi:10.1681/asn.2016060662 · Cited by 195
Carlier, P. G., Marty, B., Scheidegger, O., Loureiro de Sousa, P., Baudin, P.-Y., Snezhko, E., & Vlodavets, D. (2016) · Journal of Neuromuscular Diseases · doi:10.3233/jnd-160145 · Cited by 186
MRI in the assessment of adipose tissues and muscle composition: how to use it
Huber, F. A., Del Grande, F., Rizzo, S., Guglielmi, G., & Guggenberger, R. (2020) · Quantitative Imaging in Medicine and Surgery · doi:10.21037/qims.2020.02.06 · Cited by 102
Rausch, I., Valladares, A., Sundar, L. K. S., Beyer, T., Hacker, M., Meyerspeer, M., & Unger, E. (2021) · EJNMMI Physics · doi:10.1186/s40658-021-00364-9 · Cited by 11
Metadata
- Authors
- Bley, T. A., Wieben, O., François, C. J., Brittain, J. H., & Reeder, S. B.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2009-12-20
- Volume
- 31
- Issue
- 1
- Pages
- 4-18
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W1529328398
- Cited by
- 372
- References
- 43
- FWCI
- 10.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.