The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Fat and water magnetic resonance imaging
Abstract
A wide variety of fat suppression and water–fat separation methods are used to suppress fat signal and improve visualization of abnormalities. This article reviews the most commonly used techniques for fat suppression and fat–water imaging including 1) chemically selective fat suppression pulses “FAT‐SAT”; 2) spatial‐spectral pulses (water excitation); 3) short inversion time (TI) inversion recovery (STIR) imaging; 4) chemical shift based water–fat separation methods; and finally 5) fat suppression and balanced steady‐state free precession (SSFP) sequences. The basic physical background of these techniques including their specific advantages and disadvantages is given and related to clinical applications. This enables the reader to understand the reasons why some fat suppression methods work better than others in specific clinical settings. J. Magn. Reson. Imaging 2010;31:4–18. © 2009 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Nonalcoholic Fatty Liver Disease
Marchesini, G., Brizi, M., Bianchi, G., Tomassetti, S., Bugianesi, E., Lenzi, M., McCullough, A. J., Natale, S., Forlani, G., & Melchionda, N. (2001) · Diabetes · doi:10.2337/diabetes.50.8.1844 · Cited by 2,581
Simple proton spectroscopic imaging.
Dixon, W. T. (1984) · Radiology · doi:10.1148/radiology.153.1.6089263 · Cited by 2,276
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Sodickson, D. K., & Manning, W. J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380414 · Cited by 2,142
Chitturi, S., Abeygunasekera, S., Farrell, G. C., Holmes-Walker, J., Hui, J. M., Fung, C., Karim, R., Lin, R., Samarasinghe, D., Liddle, C., et al. (2002) · Hepatology · doi:10.1053/jhep.2002.30692 · Cited by 1,122
Rieke, V., & Butts Pauly, K. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21265 · Cited by 1,108
1H NMR chemical shift selective (CHESS) imaging
Haase, A., Frahm, J., Hanicke, W., & Matthaei, D. (1985) · Physics in Medicine and Biology · doi:10.1088/0031-9155/30/4/008 · Cited by 1,062
Reeder, S. B., Pineda, A. R., Wen, Z., Shimakawa, A., Yu, H., Brittain, J. H., Gold, G. E., Beaulieu, C. H., & Pelc, N. J. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20624 · Cited by 706
Self-citationYu, H., Shimakawa, A., McKenzie, C. A., Brodsky, E., Brittain, J. H., & Reeder, S. B. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21737 · Cited by 694
Self-citationThree‐point dixon technique for true water/fat decomposition with B0 inhomogeneity correction
Glover, G. H., & Schneider, E. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910180211 · Cited by 687
Dixon techniques for water and fat imaging
Ma, J. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21492 · Cited by 610
Multicoil Dixon chemical species separation with an iterative least‐squares estimation method
Reeder, S. B., Wen, Z., Yu, H., Pineda, A. R., Gold, G. E., Markl, M., & Pelc, N. J. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10675 · Cited by 508
Self-citationSimultaneous spatial and spectral selective excitation
Meyer, C. H., Pauly, J. M., Macovskiand, A., & Nishimura, D. G. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910150211 · Cited by 498
Fat quantification with IDEAL gradient echo imaging: Correction of bias from T1 and noise
Liu, C., McKenzie, C. A., Yu, H., Brittain, J. H., & Reeder, S. B. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21301 · Cited by 477
Self-citationMultiecho reconstruction for simultaneous water‐fat decomposition and T2* estimation
Yu, H., McKenzie, C. A., Shimakawa, A., Vu, A. T., Brau, A. C. S., Beatty, P. J., Pineda, A. R., Brittain, J. H., & Reeder, S. B. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21090 · Cited by 437
Self-citationMultipoint dixon technique for water and fat proton and susceptibility imaging
Glover, G. H. (1991) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880010504 · Cited by 405
Relaxation effects in the quantification of fat using gradient echo imaging
Bydder, M., Yokoo, T., Hamilton, G., Middleton, M. S., Chavez, A. D., Schwimmer, J. B., Lavine, J. E., & Sirlin, C. B. (2008) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2007.08.012 · Cited by 394
Water–fat separation with IDEAL gradient‐echo imaging
Reeder, S. B., McKenzie, C. A., Pineda, A. R., Yu, H., Shimakawa, A., Brau, A. C., Hargreaves, B. A., Gold, G. E., & Brittain, J. H. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20831 · Cited by 357
Self-citationMa, J. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20146 · Cited by 249
Standardized assessment of whole body adipose tissue topography by MRI
Machann, J., Thamer, C., Schnoedt, B., Haap, M., Haring, H., Claussen, C. D., Stumvoll, M., Fritsche, A., & Schick, F. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20292 · Cited by 249
Quantification of hepatic steatosis with MRI: The effects of accurate fat spectral modeling
Reeder, S. B., Robson, P. M., Yu, H., Shimakawa, A., Hines, C. D., McKenzie, C. A., & Brittain, J. H. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21751 · Cited by 248
Self-citationField map estimation with a region growing scheme for iterative 3‐point water‐fat decomposition
Yu, H., Reeder, S. B., Shimakawa, A., Brittain, J. H., & Pelc, N. J. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20654 · Cited by 217
Self-citationCramér–Rao bounds for three‐point decomposition of water and fat
Pineda, A. R., Reeder, S. B., Wen, Z., & Pelc, N. J. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20623 · Cited by 215
Self-citationKim, H., Taksali, S. E., Dufour, S., Befroy, D., Goodman, T. R., Petersen, K. F., Shulman, G. I., Caprio, S., & Constable, R. T. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21561 · Cited by 206
Linear combination steady-state free precession MRI
Vasanawala, S. S., Pauly, J. M., & Nishimura, D. G. (2000) · Magnetic Resonance in Medicine · Cited by 135
Nonalcoholic fatty liver disease and nonalcoholic steatohepatitis
Harrison, S. A., & Neuschwander‐Tetri, B. A. (2004) · Clinics in Liver Disease · doi:10.1016/j.cld.2004.06.008 · Cited by 127
Nonalcoholic Fatty Liver Disease and Nonalcoholic Steatohepatitis
Livingston, S. (2003) · PsycEXTRA Dataset · doi:10.1037/e507242006-002 · Cited by 111
Fat‐suppressed steady‐state free precession imaging using phase detection
Hargreaves, B. A., Vasanawala, S. S., Nayak, K. S., Hu, B. S., & Nishimura, D. G. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10488 · Cited by 107
The short TI inversion recovery sequence—An approach to MR imaging of the abdomen
Bydder, G. M., Pennock, J. M., Steiner, R. E., Khenia, S., Payne, J. A., & YOUNG, I. R. (1985) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(85)90354-6 · Cited by 100
Vasanawala, S. S., Pauly, J. M., & Nishimura, D. G. (1999) · Magnetic Resonance in Medicine · Cited by 89
Reeder, S. B., Pelc, N. J., Alley, M. T., & Gold, G. E. (2003) · American Journal of Roentgenology · doi:10.2214/ajr.180.2.1800357 · Cited by 73
Self-citationGerdes, C. M., Kijowski, R., & Reeder, S. B. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.07.2593 · Cited by 71
Self-citationSchick, F. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400205 · Cited by 71
Cardiac CINE imaging with IDEAL water‐fat separation and steady‐state free precession
Reeder, S. B., Markl, M., Yu, H., Hellinger, J. C., Herfkens, R. J., & Pelc, N. J. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20327 · Cited by 71
Self-citationGold, G. E., Reeder, S. B., Yu, H., Kornaat, P. R., Shimakawa, A. S., Johnson, J. W., Pelc, N. J., Beaulieu, C. F., & Brittain, J. H. (2006) · Radiology · doi:10.1148/radiol.2402050288 · Cited by 69
Self-citationLevin, Y. S., Mayer, D., Yen, Y., Hurd, R. E., & Spielman, D. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21327 · Cited by 65
Lu, A., Brodsky, E. K., Grist, T. M., & Block, W. F. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20389 · Cited by 58
Non-invasive quantification of hepatic fat fraction by fast 1.0, 1.5 and 3.0T MR imaging
Schuchmann, S., Weigel, C., Albrecht, L., Kirsch, M., Lemke, A. J., Lorenz, G., Warzok, R., & Hosten, N. (2007) · European Journal of Radiology · doi:10.1016/j.ejrad.2006.12.009 · Cited by 53
High-Resolution 3D Cartilage Imaging with IDEAL–SPGR at 3 T
Siepmann, D. B., McGovern, J., Brittain, J. H., & Reeder, S. B. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.07.2661 · Cited by 45
Self-citationArmao, D. M., Guyon, J.-P., Fırat, Z., Brown, M. A., & Semelka, R. C. (2006) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20551 · Cited by 36
Vasanawala, S. S., Hargreaves, B. A., Pauly, J. M., Nishimura, D. G., Beaulieu, C. F., & Gold, G. E. (2005) · American Journal of Roentgenology · doi:10.2214/ajr.184.5.01841450 · Cited by 35
Technical evaluation of in vivo abdominal fat and IMCL quantification using MRI and MRSI at 3 T
Li, X., YOUNGREN, J. F., Hyun, B., Sakkas, G. K., Mulligan, K. M., Majumdar, S., Masharani, U. B., Schambelan, M., & Goldfine, I. D. (2007) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2007.06.006 · Cited by 31
Improved clinical echo‐planar MRI using spatial‐spectral excitation
Schick, F., Forster, J., Machann, J., Kuntz, R., & Claussen, C. D. (1998) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880080427 · Cited by 30
Cited by
Heymsfield, S. B., Gonzalez, M. C., Lu, J., Jia, G., & Zheng, J. (2015) · Proceedings of the Nutrition Society · doi:10.1017/s0029665115000129 · Cited by 483
Kopp, C., Linz, P., Dahlmann, A., Hammon, M., Jantsch, J., Müller, D. N., Schmieder, R. E., Cavallaro, A., Eckardt, K.-U., Uder, M., et al. (2013) · Hypertension · doi:10.1161/hypertensionaha.111.00566 · Cited by 393
Fat-Suppression Techniques for 3-T MR Imaging of the Musculoskeletal System
Del Grande, F., Santini, F., Herzka, D. A., Aro, M. R., Dean, C. W., Gold, G. E., & Carrino, J. A. (2014) · RadioGraphics · doi:10.1148/rg.341135130 · Cited by 370
Skin Sodium Concentration Correlates with Left Ventricular Hypertrophy in CKD
Schneider, M. P., Raff, U., Kopp, C., Scheppach, J. B., Toncar, S., Wanner, C., Schlieper, G., Saritas, T., Floege, J., Schmid, M., et al. (2017) · Journal of the American Society of Nephrology · doi:10.1681/asn.2016060662 · Cited by 195
Carlier, P. G., Marty, B., Scheidegger, O., Loureiro de Sousa, P., Baudin, P.-Y., Snezhko, E., & Vlodavets, D. (2016) · Journal of Neuromuscular Diseases · doi:10.3233/jnd-160145 · Cited by 186
Metadata
- Authors
- Bley, T. A., Wieben, O., François, C. J., Brittain, J. H., & Reeder, S. B.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2009-12-20
- Volume
- 31
- Issue
- 1
- Pages
- 4-18
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W1529328398
- Cited by
- 372
- References
- 43
- FWCI
- 10.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.